Loading...
108 Fleet Landing Blvd 2013 HVAC .1% , `lI :, °.� �'ItisCITY OF ATLANTIC BEACH ` , 1 J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �J1lit Application Number . . . . . 13-00003350 Date 9/04/13 Property Address . . . . . . 108 FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------- Application desc 3 tons 36K BTU' s ---------------------------------------------- Owner Contractor _ ------------------------ NAVAL CONTINUING CARE AIR PRO MECHANICAL OF N FL LLC RETIREMENT FOUNDATION, INC 1008 COUNTY RD 217 1 FLEET LANDING BLVD JACKSONVILLE FL 32234 ATLANTIC BEACH FL 322334599 (904) 759-9019 ------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 83 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/03/14 ----------------------------- Other Fees . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----- ---------- Permit Fee Total 83 . 00 83 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 87 . 00 87 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)247-5845 JOB ADDRESS: d� F� T L As N(> 1al`� PERMIT# PROJECT VALUE $ `3 1cv ARI# -?JYYrSO REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer RatingREQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 13 7 Heat: Unit Quantity / BTU's Per Unit AX Seer RatingREQUIRED Duct Systems: Total CFM Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name T kk,-T LAu N W 6 Phone Number .2V&-f90 0 Mechanical Company IA;R- ffieL K11 Krq! LLQ- Office Phone;89-f9f V Fax Co. Address: �A)> ' L,/2 .2/7 City RXyV%//E State�t Zip z 2 License Holder(Print): 5k;nt4 PictwW%1-1 St e Certification/Registration#Gjri�/2 ysl�d'E Notarized Signature of License Holder Before me this day of 20 Signature of Notary Public Residential System Sizing Calculation Summary fleet landing Project Title: Code Only 108 FLEET LANDING BLVD 108 fleet landing Professional Version ATLANTIC BEACH,FL Climate:North 8/29/2013 Location for weather data: Jacksonville -Defaults: Latitude(30) Altitude(26 ft.) Temp Range(M) Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r. Winter design temperature 32 F Summer design temperature 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 18 F Total heating load calculation 38247 Btuh Total cooling load calculation 31928 Btuh Submitted heating capacity %of calc Btuh Submitted cooling capacity %of calc Btuh Total(Electric Heat Pump) 94.1 36000 Sensible(SHR=0.76) 115.9 27360 Heat Pump+Auxiliary(O.OkW) 94.1 36000 Latent 103.9 8640 Total Electric Heat Pum 112.8 36000 WINTER CALCULATIONS Winter Heatin Load for 1732 s ft �„%� Load comDonent Load ~dowxm%) Window total 247 sqft 8166 Btuh Wall total 1620 sqft 5840 Btuh N Door total 38 sqft 502 Btuh Ceiling total 1804 sqft 2382 Btuh Floor total 180 sqft 8071 Btuh Infiltration 221 cfm 9247 Btuh Duct loss 4039 Btuh Subtotal 38247 Btuh ,:� va.c,sz� Ventilation 0 cfm 0 Btuh % TOTAL HEAT LOSS 38247 Btuh SUMMER CALCULATIONS Summer Cooling Load for 1732 s t Load com nent Load Window total 247 sqft 6607 Btuh Wall total 1620 sqft 4041 Btuh Door total 38 sqft 383 Btuh Ceiling total 1804 sqft 2068 Btuh r��M,ox) r. wao�cxx, Floor total 0 Btuh Infiltration 158 cfm 3118 Btuh Internal gain 3840 Btuh Duct gain 3554 Btuh wascux7 `"°'fig” Sens.Ventilation 0 cfm 0 Btuh Total sensible gain 23611 Btuh Latent gain(ducts) 1041 Btuh rt _ w«sns+q Latent gain(infiltration) 5676 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemaVoccupants/other) 1600 Btuh Total latent gain 8316 Btuh TOTAL HEAT GAIN 31928 Btuh EnergyGauge®Syste Version 8 PREPARED B For Florida residences only DATE: EnergyGaugeO FLRCPB v4.5.2 System Sizing Calculations - Summer Residential Load - Whole House Component Details fleet landing Project Title: Code Only 108 FLEET LANDING BLVD 108 fleet landing Professional Version ATLANTIC BEACH,FL Climate:North Reference City.Jacksonville (Defaults) Summer Temperature Difference:18.0 F 8/29/2013 Component Loads for Whole House.: . . ;: I; '-: . .� .. Type' Overhang Window Area(sqft) HTM Load Window PrdSHGCIU/InSh/ExSh/IS Olt Len H Gross Shaded Unshad Shaded Unshaded 1 2,Clear,0.87,None,N,H E 1.4ft 1ft. 60.0 60.0 0.0 27 72 1605 Btuh 2 2,Clear,0.87,None,N,H N 1.4ft 1ft. 30.0 0.0 30.0 27 27 802 Btuh 3 2,Clear,0.87,None,N,H W I.4ft 1ft. 60.0 60.0 0.0 27 72 1605 Btuh 4 2,Clear,0.87,None,N,H S 1.4ft 1ft. 6.0 6.0 0.0 27 32 160 Btuh 5 2,Clear,0.87,None,N,H S 1.4ft 11t. 15.0 15.0 0.0 27 32 401 Btuh 6 2,Clear,0.87,None,NA W 1.4ft 1ft. 40.0 40.0 0.0 27 72 1070 Btuh 7 2,Clear,0.67,None,N,H W 1 4ft 1ft. 36.0 36.0 0.0 27 72 963 Btuh Window Total 247(sqft) 6607 Btuh Walls TypeR-Value/U-Value Area(sqft) HTM Load 1 Frame-Wood-Ext 11.0/0.09 1154.0 2.6 2967 Stuh 2 Frame-Wood-Ext 11.010.09 322.0 2.6 828 Btuh 3 Frame-Wood-Adj 11.0/0.09 144.0 1.7 246 Btuh Wall Total 1620(sqft) 4041 Btuh Doors Type Area(sqft) HTM Load 1 Insulated-Exterior 20.0 10.1 203 Btuh 2 Insulated-Adjacent 17.8 10.1 180 Btuh Door Total 38(sqft) 383 Btuh Ceilings Type/Color/Surface R-Value Area(sqft) HTM Load 1 Vented Attic(DarkTile 30.0 1500.0 1.1 1576 Btuh 2 Vented AtGdDarkTile 19.0 232.0 1.6 375 Btuh 3 Vented AttidDarkTile 19.0 72.0 1.6 116 Btuh Ceiling Total 1804(sqft) 2068 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 180 M(p)) 0.0 0 Stuh Floor Total 180.0(sqft) 0 Btuh Envelope Subtotal: 13099 Btuh Infiltration Type ACH Volume(cuft)wall area(sqft) CFM= Load SensibleNatural 0.42 22516 1620 221.4 3118 Btuh Internal Occupants Btuh/oocupant Appliance Load gain 8 X 230 + 2000 3840 Btuh Sensible Envelope Load: 20057 Btuh Duct load (DGM of 0.177) 3554 Btuh Sensible Load All Zones 23611 Btuh EnergyGauge®FLRCPB v4.5.2 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Code Only fleet landing 108 fleet landing Protessional Version 108 FLEET LANDING BLVD g Climate:North ATLANTIC BEACH,FL 8t2gl2013 WHOLE HOUSE TOTALS `" Sensible Envelope Load All Zones 20057 Btuh Sensible Duct Load 3554 Btuh Total Sensible Zone Loads 23611 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 23611 Btuh Totals for Cooling Latent infiltration gain(for 53 gr.humidity difference) 5676 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1041 Btuh Latent occupant gain(8 people @ 200 Btuh per person) 1600 Btuh Latent other gain 0 Btuh Latent total gain 8316 Btuh TOTAL GAIN 31928 Btuh EQUIPMENT 1.Central Unit # ----F 36000 Btuh 'Key: Window types(Pn-Number of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEF'for default) (InSh-Interior shading device:none(N),Blinds(B),Draperies(D)or Roller Shades(R)) (ExSh-Exterior shading device:none(N)or numerical value) (BS-Insect screen'.none(N),Full(F)or Half(H)) 10 (Ornt-compass orientation) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5.2 Page 2