Loading...
720 Selva Lakes Cir 2013 HVAC _q CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 DEIS), Application Number . . . . . 13-00003393 Date 9/10/13 Property Address . . . . . . 720 SELVA LAKES CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -------------- ------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WILLIAMS, PHILIP L B/E DONOVAN HEATING & AIR 720 SELVA LAKES CIR 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322334350 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc - - . 00 Permit Fee . . . . 103 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/14 -------------- ------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)247-5845 /C_.PERMrr# FOB ADDRESS: SC - r PROJECT VALUE $ ARI# REQUIRED Air Handling Equipment Only _XAir Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit — Heat: Unit Quantity BTU's Per Unit Seer Rating j ffQ—UIRED Duct Systems: Total CFM IEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 - !�7 BTU's Per Unit 4F—oc Seer Rating Heat: Unit Quantity o QUIRED Duct Systems: Total CFM ?IRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity ?IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty— Automobile Lifts BTU's Gas Piping Outlets Boilers Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets P'umps BTU's #Vented Wall Furnaces Refrigerator Condenser #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ork is suspended ar abandoned for six months.I hereby certify that I h= ermit becomes void if work does not commence within a six month period or w ming this work will be complied with whether specified or iis application and know the same to be true and correct. All provisions of laws and ordinances gove ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Iroperty Owners Name VV P Phone Number ,PAA10Wt,1 ..Office Phone Aechanical Company city Tt4X 1-�A State R- zip 1 1) 5- 6f-� lo. Address: State Certification/Registration# ,icense Holder(Print): V'iotart ed Si nature of Lkense Holder .z r otary Public State of Florida efore m6s day of 20—L- > Timothy Lee Hughes Ott'.,j my commission EE 186278 ignature of Notary Public Expires 0410312016 Job: Project Summary Date: 915/13 wrightsoft Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FIL 32250 Phone:241-3785 Email:brandon@donovanac.com Project Information For: Philelva lakes cir, Atlantic Beach, FL 32233 720 Notes: Izaare-F-11slil Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 *F Outside db 95 'F Inside db 68 'F Inside db 75 oF Design TD 29 *F D:sign TD 20 'F D ,y range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6189 Btuh Ducts 12799 Btuh Central vent (33 cfm) 727 Btuh Central vent (33 cfm) 1054 Btuh 0 Btuh Humidification 0 Btuh Blower Piping 0 Btuh Use manufacturer's data n Equil5ment load 25176 Btuh Rate�/swing multi lier 1.00 Infiltration Equipment sensigle load 29357 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1948 Btuh Ducts 2254 Btuh Heating Cooll Central vent (33 cfm) 1196 Btuh Area M� Equipment latent load 5397 Btuh mft�Ift ent total load 34754 Btuh Volu e 16146 16146 Air 9hanges/hour 0.45 0.20 Equipm al capacity at 0.70 SHR 3.5 ton Equiv.AVF (cfm) 122 54 Req. tot Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade TXH542 Model TXH542 Cond ARI ref no. 3650246 Coil FXM4X42 ARI ref no. 3650246 15 SEER Eff iciency 8.7 HSPF Efficiency 30163 Btuh Heating input Sensible cooling 12927 Btuh Heating output 42875 Btuh @ 47'F Latent cooling 43090 Btuh Temperature rise 27 'F Total cooling 1436 cfm Actual air flow 1436 cfm Actual air flow 0.050 cfm/Btuh Air flaw factor 0.060 cfm/Btuh Air flow factor 0 in H20 Static pressure 0 in H20 Static pressure Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Sep45 14:18:01 Right-SuiteS Universal 7.1.01 RSU05996 Page 1 ACCA c:\u sers\Sales\D ocuments\Wrights oft HVAC\3.5TON Calc=MJ8 orientation=N This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service ru swal CERTIFIED, between Feb 17, 2009 and Dec 31, 2013. Lwww.ahridirectory.org 'A' Certificate of Product Ratings AHRI Certified Reference Number: 3650246 Date: 9/5/2013 Product: Split System: Heat pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: TXH542GKA* Indoor Unit Model Number: FXM4X42**A* Manufacturer: TEMPSTAR Trade/Brand name: SMARTCOMFORT TX 5500 R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 41500 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 36800 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 26400 voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. Ratings followed by an asterisk(*)indicate a DISCLAIMER — e and makes no representations,warranties or guarantees as to,and assumes no responsibility for, AHRI does not endorse the product(s)listed on this Certificat r damages of any kind arising out of the use or performance of the product(s),or the the product(s)listed on this Certificate.AHRI expressly disclaims all liability fo unauthorized alteration of data listed on this certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS AHRI.This Certificate shall only be Used for individual,personal and confidential reference purposes. This Certificate and its contents are proprietary products of reproduced;copied;disseminated;entered into a computer database;or otherwise utifized,in any The contents of this Certificate may not,in whole or in part,be form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION A& "Imm Air-Conditi ning,Heating, The information forthe model cited on this certificate can be verified at www.ahridirectory.org, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on Itlill" ON ILI and Refrigeoration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed Wow. CERTIFICATE NO.: 130228784336896215 @2013 Air-Conditioning, Heating,and Refrigeration Institute