790 Sabalo Dr 2013 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
A19
Application Number . . . . . 13-00003470 Date 9/30/13
Property Address . . . . . . 790 SABALO DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
3 TONS 33K BTU' S
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SMITH, JOSEPH AIR EXCELLENCE INSTALLATION
790 SABALO DRIVE AND SERVICE INC
ATLANTIC BEACH FL 32233 3813 BALD EAGLE LA
JACKSONVILLE FL 32257
(904) 923-4967
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/29/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: '1'&� SkBikt-0 RID *rLAjs..njC 8eU-,*j fi, -VZS-3 PERMIT
PROJECT VALUE $ epp emp ARI# SV(7 1 q (o
REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 3
Heat: Unit Quantity I BTU's Per Unit S3,000 Seer Rating 13
Duct Systems: Total CFM REQUIRED
Manual J documentation required on residential change out
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
TIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
�LL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
)THER:
-rinit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have`7rad
is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
it. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
roperty Owners Name 10--C-6poi S'Wixi't PhoneNumber
lechanical Company AP- 1A6M11*Vd0 10e,. Office Phone fZ,3'qA-7 Fax Z161b -0?03
Address: 3913 bl-t 461-6 (A-AJ6 City ��r �WU:.6 State k Zip T
Icense Holder (Print): -?�P4-p State Certification/Registration#
Warized
JOYCE&BIGHAM
0 FF
MY COMMISSION,:or] —da
EXPIRES:June 25,Xfor methis 30�d
. ..... WOE
Bonded Thru NoWy RiNt Undewhrs
f
re of Notary Publi
4 m
Job: AFMA/Srnith2013
wrightsoft Right J@ M o bile Report Date: 9/26/2013
Entire House By: Ronald Lee
Air Excellence Installation & Service, Inc.
3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone 904-923-4967 Fax:904-268-0903 Email:airexceliencejax@comcast.net Web:http:11vvWw.airexcellencef1a.com Lic
Project Information
For: Joseph Smith
7090 Sabalo Drive,Atlantic Beach, FL 32233
Phone: 904-469-9916
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(T) 70 75
Elevation: 43 ft Design TD ('F) 35 16
Latitude: 30'N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(T) 35 91 Infiltration:
Dailyrange (T) - 17 ( M Method Simplified
V�btbulb(oF) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
�M�
Component Btu h/ft' Btuh %of load
Walls 3.1 4493 15.9 VAIS
Glazing 19.7 3188 11.3 DAS
Doors 13.5 425 1.5
Ceilings 2.4 3924 13.8 GMrg
Floors 2.7 4372 15.4
Infiltration 2.2 3509 12.4 Cilff
Ducts 8423 29.7
Piping 0 0 Oilirgs HWakn
Humidification 0 0 40
Ventilation 0 0 RWS
Adjustments 0
1 Total 1 1 283341 100.01
Component Btu h/ft' Btuh %of load
Walls 1.3 1922 7.6 wils Interd Gains
Glazing 36.2 5859 23.1
Doors 11.4 360 1.4
Ceilings 3.0 4854 19.1 Gadng
Floors 1.0 1617 6.4
Infiltration 0.5 870 3.4 Ducts
Ducts 6846 26.9
Ventilation 0 0
Internal gains 3090 12.2 Cther
Blower 0 0 . birfiltration
Adjustments 0 CeilinTg's, 191
Total 1 1 25418, 100.01
Latent Cooling Load=3998 Btuh
Overall U-va lue =0.098 Btuh/ftl-'F
Data entries checked.
2013-Sep-26 13:52:06
AL_= + wrightSOft Right-SuiteO universal 2013 13.0.06 Right J@ Mobile Page I
A__c4k ...\wstmp\7176b5f2-9790-4820-9ada-4633ba8d87f5.rup Calc=MJ8 Front Door faces, N
Project Summary Job: AEiIA,'SMith2013
wrightsoft Date: 912'&2013
Entire House By: Ronald Lee
Air Excellence installation & Service, Inc.
381';Bad Eag�e Lane.Jacksonvil[e.;!L 322"7 Phone:904-923-4967 Fax:904-2W-0903 Ernast:akexce4�ercelaxocorrcast.netNeb titp,�',�^�ww.airexoellencefa.com L,c,.
Project Information
For� Joseph Smith
7090 Sabalo Drive, Atlantic Beach, FIL 32233
Phone- 904-469-9916
Notes:
Design Information
Weather: JaCksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 35 OF Design TD 16 OF
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 19911 Btuh Structure 18572 Btuh
Ducts 8423 Btuh Ducts 6846 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 BtUh Blower 0 BtUh
Piping 0 Btuh
Equipment load 28334 Btuh Use manufacturer's data y
Ratelswing multiplier 100
Infiltration Equipment sensible load 25418 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2343 Btuh
Ducts 1655 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ftz) '1620 1620 Equipment latent load 3998 Btuh
Volume(fts) 14580 14580
Air changesihour 0.38 0-20 Equipment total load 29416 Btuh
Equiv- AVF (cfm) 92 49 Req. total capacity at 0.70 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Make Goodman
Trade Goodman Trade Goodman
Model ARUF36C14B Cond GSZ130361B
AHRI ref 5647196 Coil
AHRI ref 5647196
Efficiency 8 HSPF Efficiency 13 SEER
Heating input Sensible cooling 18410 Btuh
Heating output 33000 Btuh Latent cooling 7890 Btuh
Temperature nse 26 OF Total cooling 26300 Btuh
Actual air now 1157 ctm Actual air flow 1157 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 086
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Sep-20 13:52,07
+ wrightSOft Right-Suftee Unrversal 2013 13.0.D6 Right. J9 Vloble Page I
'.wstmp��717Cbtf2-97NA82D-gada-4e33ba8d87f5rup Ca1c=MJ8 FrontDoorfaces N
^ Ulm
NOU sual CERTIFIEDT.
L www.ahridirecory.org J
Certificate of Product Ratings
AHRI Certified Reference Number: 5647196 Date: 9/26/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130361B*
Indoor Unit Model Number: ARUF36C14B*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING ND
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 33000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 33000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F: 20800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Cenificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and fts contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in parL be reproduced;copied;disseminated;entered into a computer database;or othervAse utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on no ILI and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is fisted below.
@2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130246982590215349
wrightsoft Right-M) Worksheet Job: AE1lA/Smith2013
Entire House Date: 9/26/2013
Air Excellence Installation & Service, By: Ronald Lee
Inc.
3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone 904-923-4967 Fax:904-268-0903 Email:airexceliencejax@comeast.net Web:http:ltwww.airexceliencefla.com Li...
1 Room name Entire House First Floor
2 Exposed wall 180.0 It 180.0 It
3 Room height 9.0 ft d 9.0 ft heat/rool
4 Room dimensions 1.0 x 1620.0 ft
5 Room area 1620.0 ft2 1620.0 ft2
I I I I I I
Ty � Construction U-value, Or I HTM Area Load Area (ft) I Load
number (Btuh/W�- F) (Btuh1ft2) or perimett'e)r ft) (Btuh) or perimfett'e)r (Btuh)
iHeat I Cool j Gross I N/PIS j Heat I Cool i Gross NIP/S Heat Cool
6 V" 12C-Obw O�091 n 3.15 1.35 540 487 1532 655 540 487 1532 655
1 Dc2ow 0.570 n 19,72 20.91 53 0 1052 1115 53 0 1052 1115
2C-Obw 0.091 e 3.15 1.35 270 243 766 328 270 243 766 328
1_6 11 D-c2ow 0570 e 19.72 63.01 27 0 526 1680 27 0 526 1680
11 I= 12C-Obw 0.091 s 3.15 1.35 540 454 1428 611 540 454 1428 611
1 D-c2ow 0.570 s 19.72 25A6 55 0 1085 1384 55 0 1085 1384
11DO 0390 s 13.49 11.43 32 32 425 360 32 32 425 360
'2C-Obw 0.091 w 3.15 1.35 270 243 766 328 270 243 766 328
t---G I D-c2ow 0570 w 19.72 63.01 27 0 526 1680 27 0 526 1680
C 16C-13al 0.070 2.42 3.00 1620 1620 3924 4854 1620 1620 3924 4854
F 20P-1 1t 0.078 2.70 1.00 1620 1620 4372 1617 1620 1620 4372 1617
1 1, 1
1 61 c)AED excursion 01 1 1 1 0
Envelope loss/gain 1 164021 146121 1 1 16402 1
12 a) Infiltration 3509 870 3509 870
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 3 690 3 690
Appliances/other 2400 2400
Subtotal(lines 6 to 13) 19911 18572 19911 18572
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 19911 18572 19911 18572
15 Duct loads 42% 37% 8423 6846 42% 37% 8423 6846
Total room load 283341 254181 1 1 283341 254181
Air required(cfm) 767 1157 767 1157
Calculations amroved by ACCA to meet all reciuirements of Manual J 8th Ed.
2013-Sep-26 13:52:07
44d- wriii4ghtscift Right-Suite@ Universal 2013 13.0.06 Right JV Mobile Page I
\wstmp\7176b5f2-9790-4820-9ada-4633ba8d87f5.rup Calc=MJ8 Front Door faces: N
Component Constructions Job: AFMA/Smith2013
wrightsoft Date: 9126/2013
Entire House By: Ronald Lee
Air Excellence Installation & Service, Inc.
3813 Bald Eagle Lane,Jacksonville,FIL 32257 Phone 904-923-4967 Fax:904-268-0903 Email:airexcellencejax@comr-ast.net Web:hUpWwwwairexcellencefla.corn Lic
Project Information
For: Joseph Smith
7090 Sabalo Drive,Atlantic Beach, FL 32233
Phone: 904-469-9916
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature (T) 70 75
Elevation: 43 ft Design TD(T) 35 16
Latitude: 30'N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(T) 35 91 Infiltration:
Dailyrange (T) - 17 M Method Simplified
VVet bulb('F) - 77 Construction quality Average
VVind speed (mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain
ft2 Eftuh/ft2-*F W-*F/Btuh Btih A? Btuh Btuh ff Btuh
Walls
12C-Obw:Frm wall,brk 4"ext,r-13 cav ins, 1/2"gypsum board int n 487 0.091 13.0 3.15 1532 1.35 655
fnsh,2"x4"wood frm e 243 0.091 13.0 3.15 766 1.35 328
s 454 0.091 13.0 3.15 1428 1.35 611
w 243 0.091 13.0 3.15 766 1.35 328
all 1427 0.091 13.0 3.15 4493 1.35 1922
Partitions
(none)
Windows
1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innF, 1/4"gap, n 53 0.570 0 19.7 1052 20.9 1115
1/8"thk e 27 0.570 0 19.7 526 63.0 1680
s 55 0.570 0 19.7 1085 25.2 1384
w 27 0.570 0 19.7 526 63.0 1680
all 162 0.570 0 19.7 3188 36.2 5859
Doors
11 DO:Door,wd sc type s 32 0.390 0 13.5 425 11.4 360
Ceilings
16C-1 3al:Attic ceiling,asphalt shingles roof mat,r-1 3 Geil ins, 1/2" 1620 0.070 13.0 2.42 3924 3.00 4854
gypsum board int fnsh
Floors
20P-1 1 t:Fir floor,wd fir,1"thkns,tile fir fnsh,r-1 1 ext ins,amb ovr 1620 &078 11.0 2.70 4372 1.00 1617
2013-Sep-26 13:52:07
wrightSOft Right-Suitee Universal 2013 13.0.06 Right JO Mobile Page 1
X--c4h, ...kwstmp\7176b5f2-9790-4820-9ada-4633ba8d87f5.rup Calc=MJ8 Front Door faces: N
Job: AE/IA/Smith2013
wrightsoft AED Assessment Date: 9126/2013
Entire House By: Ronald Lee
Air Excellence Installation & Service, Inc.
3813 Bald Eagle Lane,Jacksonville,FL 32257 Phone:904-923-4967 Fax:904-268-0903 Email:airexcelienceiax@comcast.net Web:hftp:/twww.airexceliencefla.com Lic...
Project Information
For: Joseph Smith
7090 Sabalo Drive,Atlantic Beach, FL 32233
Phone: 904-469-9916
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature (T) 70 75
Elevation: 43 ft Design TD(T) 35 16
Latitude: 30'N Relative humidity (%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(T) 35 91 Infiltration:
Dailyrange (oF) - 17 M
Wet bulb('F) - 77
Wind speed (mph) 15.0 7.5
Test for Adequate Exposure Diversity
Hourly Glazing Load
9'00C_
8,OOC-
TOO&
6,00C-
5,0012-
4,OOC,
3,OOC-
2,OOC-
1'00C_
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Hariy ARrage PEDIirlit
Maximum hourly glazing load exceeds average by 19.8%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-Sep-26 13:52 07
wrightSOft Right-Slit,@ Universal 2013 13.0.06 Right J8 Mobile Page 1
ACC�, ...kwstmp\7176b5f2-9790-4820-gada-4633ba8d87f5.rup Calc=MJ18 Front Door faces: N
-8k
N
First Flooi
Fir5t Floot
-----------
Job#: AE/IA/Smith2013 Air Excellence Installation & Service, I.- Scale: 1 100
Performed by Ronald Lee for: Page 1
Joseph Smith 3813 Bald Eagle Lane Rg ht-Su ite@ Univ ersa 12013
7090 Sabalo Drive Jacksonville, FL 32257 13.0.06 Rght J@)k1lobile
Atlantic Beach,FL 32233 Phone: 904-923-4967 Fax� 904-268-0903 2013-Sep-26 13:52:08
Phone:904-469-9916 lhttp://ww,.airexcellencefla.com airexcellencejax@... J...-9790-4820-9ada-4633ba8d87f5