159 3rd ST 2013 hvac CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003490 Date 10/02/13
Property Address . . . . . . 159 3RD ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES SF DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
RILEY DONALD L HUXHAM HEATING & AIR
159 3RD ST 2101 FLORIDA BLVD.
ATLANTIC BEACH FL 322335208 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/31/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
goo Seminole Rd Atlantic Beach,Fl,32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDRESS: �s f TJMT#
PROJECT VALUE S
NEW AIR CONDITIONING & BEATING SYSTEM INSTALLATION
Air Conditioning- Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratin ULRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARi#
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity BTUs Per Unit 2Q.coo Seer
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if does not commence within a sm month period or work is suspended or abandoned for sLx months.I fy that I have read
this apphcatlon and know the same to be true and corrmt All provmons of laws and ordmances,governmg dus work WW be complied math whether specified
or noL The permit does not give mWwnty to violate the provisions of any other state or local law regulation construction or the perfomunce of conshuction.
property Owners Name Phone Number -?
Office Phone,9Vk7- �j I Fax:2V& -o3
Mechanical Company
Cj
a? A 14 state Tj- zip 3 9:9-5c)
ty
Co. Address: t---5
License Holder(Print): :31-� State Ceftifi�on/Rgiwation# CS
Nowmend Signature of Lj"nse Holder
Se
swomlam subscribed before me this—day of 2Q__
Signature of Notary Public
Job: 1002132
Project Summary Date: Oct 02,2013
Entire House By: ERIN RODRIGUEZ
Project Information
For: RILEY
159 3RD STREET,ATLANTIC BEACH, FL 32233
Notes: HUXHAM-CHANGE OUT
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 92 oF
Inside db 68 'F Inside db 74 'F
Design TD 29 'F Design TD 18 oF
Daily range L
Relative humidity 50 %
Moisture difference 60 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16405 Btuh Structure 21319 Btuh
Ducts 6250 Btuh Ducts 8551 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22655 Btuh Use manufacturers data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 28974 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 0 Structure 647 Btuh
Ducts 2320 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ftJ 1479 1479 Equipment latent load 2967 Btuh
Volume(ft") 11832 11832
Air changes/hour 0.16 0.08 Equipment total load 31940 Btuh
Equiv. AVF (cfm) 32 16 Req.total capacity at 0.70 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade XB13 WEATHERTRON Trade XB13 WEATHERTRON
Model 4TWB3042131 Cond 4TWB3042B1
AHRI ref 4643655 Coil 4TAMAOB42
AHRI ref 4643655
Efficiency 8.5 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 29050 Btuh
Heating output 39500 Btuh@47-F Latent cooling 12450 Btuh
Temperature rise 26 'F Total cooling 41500 Btuh
Actual air flow 1383 Gfm Actual air flow 1383 cfm
Air flow factor 0.061 cfm/Btuh Air flow factor 0.046 Gfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Oct-02 13:59:33
Aftk, + wrighVs0ft Right-Suite(&universal 2012 121+08 RSU01508 Page I
...nts\Wrightsoft HVAC\Ternplate\HUXHAM-RILEY.rup Calc=MJ8 Front Door faces: W