Loading...
90 Ocean Breeze Dr 2013 HVAC CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003506 Date 10/09/13 Property Address . . . . . . 90 OCEAN BREEZE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 2 cu 2 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WALSHAW, LARRY E * MICHELLE FLORIDA HOME AIR COND DBA ARS 90 OCEAN BREEZE DR 4211 EMERSON ST ATLANTIC BEACH FL 322335953 JACKSONVILLE FL 32207 (904) 777-4300 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 139 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/07/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 09 STATE MECH DBPR SURCHARGE 2 . 09 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 139 . 00 139 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 18 4 . 18 . 00 . 00 Grand Total 143 . 18 143 . 18 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 O�n Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 1`) 00 o 61 ee l� e- Do U e , PERMIT# PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3 7D5Cx95�3-7b5 103 Air Conditioning: Unit Quantity 2 Tons Per Unitl d-3 704 REQUIRED Heat: Unit Quantity— BTU's Per Unit Seer Rating I �J Ser, Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: 3 N�uZ 1 (Z Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. I'> Property Owners Name >ChW e ��{ a h G yJ _Phone Number (941- 2 Mechanical Company AG k-'(w Office Phone!a]-�-QWJ Fax Co. Address: H 2j I (� e rSlm City State EL Zip 32 3 License Holder (Print): .,-` . ►. �-�- State Certification/Registration#CV'(1C1Z�l�q 3°I i Notarized Signature of License Holder Sworn and subscribed before nKf9is � ✓ 20-a Signature of Notary Public Nota P tl-� r 8 Commission No.EE 84823 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service Amin Wmad CERTIFIED,. between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org A' Certificate of Product Ratings AHRI Certified Reference Number: 3705103 Date: 10/7/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 15PJL36 Indoor Unit Model Number: RHLL-HM3617+RCSL-H*3617 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 15PJL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 35400 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 34600 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 22200 'Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and entertheAHRI Certified Reference Numberand the date on &On .n ,' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130256473985337920 This combination qualifies for a Federal Energy 0% Ulm Efficiency Tax Credit when placed in service 9%1 smal CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013. www.ahridirecory.org Certificate of Product Ratipgs AHRI Certified Reference Number: 3705065 Date: 10/7/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 15PJL30 Indoor Unit Model Number: RHLL-HM3617+RCSL-H*3617 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 15PJL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 28800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 27200 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 16300 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, w "IM Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 01W am `' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 92013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130256477089897120 Designstar Load Calculation Results are intended for use with Rheem heating and cooling systems 'customer • • Street Address 90 OCEANBREEZE DRIVE, Atlantic Beach, FL 32233 ..................................._..........._......._..._.._.._................_..........._...._._ ._ _.._.........._...................._........................................................................._._................._......................................_..._.._.._..._.._ Latitude, Longitude 30.3375°, -81.7686° House Square 3327 sq. ft. Footage: Name: LARRY & MICHELLE WALSHAW Phone: 904-247-0021 ---........................_...__...._. ............___._........ ..__.........._.._._........................................................................................................................................................__......._.......... Email: .._..........._........................................._......._.........................._..........._............_...................._......._..._........_.___ 'House • . • SHR .75 Number of residents 2 ............._.._......................-......................_............................_....................._..........._........................._........................................................--..._......._......._................_........................._......._..........._.._..._........ Ceiling height 9 Wall U-value R-value 0.09111 ........................................................................................_......................................_............................_...................................__......................................_............. ........... Floor U-value R-value 0.2 15 Ceiling U-value I R-value 0.053 119 ................_.._..._.....1--....................._........................................................_.._.._......._.._............_.._..._....._.........................................................._.............................................................._.._............... ..... Window U-value 0.5 Window SHGF 0.85 ....._.._..._.._..._.............................................................................---............-...._.................................................................................._......._.._....................._................................... Moisture grains 53 Duct loss % 10 1----.-.-...1 __............ ............_........................,......_......................................................................................_................_............................__................................................................ ............. Duct gain % 10 Cooling infiltraction (ACH) 0.6 _. ................._........................................-...........................................I................1-1--...........................I............................................... 11............ ......................................... Heating infiltration (ACH) 0.8 Winter ventilation 0 _............I-_................................................._.................................................._........._..._................................__..._..........._........_..............._......._..._......_......._..._.................................._.._........_.._.._........ Design Conditions Outdoor Heating Cooling Dry bulb (°F) 32 93 Daily range M Relative humidity 50% Moisture difference 53 IndoorHeating Cooling Indoor temperature (°F) 70 75 Design temperature differenceff) 38 18 [Heating Load Area Btuh % of load ............... re ................._............._............................._........... Wall 5467 9.4 .........................................................................................................._...................................._............................................. Floor 15930 27.5 Ceiling 6701 11.6 Windows 9082 15.7 Infiltration 15520 26.8 ......................................................................_...................................._..........................._................ System Efficiency Loss 5270 9.1 Total: 57969 Heating Loads 57,969 BTU/hr r System Efficiency Loss Floor� A111-Wall Ceiling Windows Infiltration J ooling Loads Area Btuh % of load .............................................. . Wall 4028 6.3 Ceiling 9346 14.6 ................ .................... _..................._..._. Windows 23300 36.4 _......._......_..............-....................._......__..............._.....-.................._....._............... ........._......_.........._._. Sensible Infiltration 5514 8.6 .............................._..........._..................................................._.................................._........................................... Latent Infiltration 10036 15.7 System Efficiency Gain 5222 8.2 _ .............. . Internal 5656 8.8 ............._........._.........................................._.................................._.........._...._.. Sensible People Load 460 0.7 .........................................._..._..................................._.......................................... _ Latent People Load 460 0.7 Total: 64022 Sensible load 53526 Latent load 10496 SHR 0.84 Capacity at .75 SHR 5.95 Tons . Cooling Loads 64,022 BTU/hr it Sensible People Load Latent People Load ---Wall System Efficiency Gain Windows Sensible Infiltratioi Internal Ceiling Latent Infiltration AED Graph aonoo '� 30000 20000 — J iI 10000 0 8am 9am r loam Ilam 12pm 1pm 2pm 3pm 4pm Spm 6pm 7pm 8pm —Hourly Loads —Average i • • • System equipment selection will be made using the following derived values. Glass (SW) 241 sq. ft. ---..........-.1.............-.—......... - Glass (NW) 34 sq. ft. ....I--................................................................................................. Glass (SE) 34 sq. ft. ......................................_................ ._........................................................_...... Glass (NE) 169 sq. ft. ................,....................- ............................................................... Summer Outdoor 930F _....._.._...._................................._.._.._.._.._.._._ Summer Wet Bulb 77°F ................................._..-......_....................._...............................................................-.............._....................._........................_.... Summer Indoor 750F _..........._.._.._._..._........_.._..._....................._._.._..._.._._............. Summer Design Grains 50% ........................................_..........._...................._..._.._........................._........................._................................................ Winter Outdoor 320F ... .. . _.._.. WinterIndoor d oo r _._.._..._.......___. 70°F _................ _......................._.._.._.._._.._.._....................................................................._..._._.._...._...._........................................ Sensible Cooling 53,526 Btuh ................................................._.._........_.._... _.._.._..._. Latent Cooling 10,496 Btuh ............. .._ __._.._..._.... .... .. ........._......___......... -111-1 Required Cooling Airflow 2,433 CFM Sensible Heating 57,969 Btuh -.._.._.._._.._.._.._ ........... .. ...._............ ..... ........ .._.._.._........................ ....... ........ ..----------- ..._._.._._._ ................. ............................._.__.._...................._...__.._._......._. Required Heating Airflow 753 CFM --.1.................. ........................................-- --.............................. ........... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree 'raj!y-L`Jfj�� CITY OF ATLANTIC BEACH s f 800 SEMINOLE ROAD r� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003679 Date 11/19/13 Property Address . . . . . . 90 OCEAN BREEZE DR Application type description ELECTRIC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ----------------------------------- Application desc breaker chg for ac --------------------------------- Owner Contractor ---------- ------------------------ -------------- WALSHAW, LARRY E * MICHELLE AMERICAN ELECTRICAL CONTRACTOR 90 OCEAN BREEZE DR 5065 ST. AUGUSTINE RD #13 ATLANTIC BEACH FL 322335953 JACKSONVILLE FL 32207 (904) 737-7770 ---------- ----------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . • plan Check Fee . 00 Permit Fee . . . . 60 . 00 0 Issue Date Valuation Expiration Date . . 5/18/14 _ _ ------ Other Fees STATE ELEC DCA SURCHARGE 2 . 00 STATE ELEC DBPR SURCHARGE 2 . 00 _ ________ ---- Fee summary Charged Paid Credited ----Due--- _ _ ------ - ---------- ---------- Permit Fee Total 60 . 00 60 . 00 00 . 00 00 . 00 Plan Check Total . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 64 . 00 64 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 b,,,3 ADDRESS: � `� �C�io �ruf z� PERMIT# JEA INFORMATION REQUIRED ON ALL PERMITS GU' AMPS �� VOLTS PHASE VAL UE OF WORK$ NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole -Residential(Main) Service s #of Meters - am 0-100 amps -101-150amps E 151-200amps P Commercial(Main) Service --0-100 amps -101-150amps E 151-200amps amps CT Service amps Conductor Type Size Multi-Family(Main) Service -0-100 amps 101-150amps " 151-200amps amps #of Unit Meters Temporary Pole =- amps SERVICE UPGRADE i amps - CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) -100 amps C�150amps 200amps - amps -CT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS Swimming Pool Sign Cl Smoke Detectors_Qty ETransformers KVA Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK$—1010 Qty volts/amps REPAIRS/MISCELLANEOUS Replace Burnt/Damaged Meter Can Safety Inspection Panel Change -OH to UG Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name tr ;L�,� ��, 5 �,I r Phone Number t l Electrical Company American Electrical Contracting, INC Office Phone 904-737-7770 Fax Co. Address: 5065-3 St Augustine Rd 71 I'll, City Jacks ville State FL Zip 32207 L'- -ase Holder (Print):Earl W. Frick ification/Registration# ER0015 3l b D P er , Notery Public State of Florida 20 '' ; Anna M Daly orn and subscribed be re�lthis day of My Commissloo EE 850790 ' � Expireeo1012017 ature of Notary Pub *c