90 Ocean Breeze Dr 2013 HVAC CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003506 Date 10/09/13
Property Address . . . . . . 90 OCEAN BREEZE DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES GEN MF DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
2 cu 2 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
WALSHAW, LARRY E * MICHELLE FLORIDA HOME AIR COND DBA ARS
90 OCEAN BREEZE DR 4211 EMERSON ST
ATLANTIC BEACH FL 322335953 JACKSONVILLE FL 32207
(904) 777-4300
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 139 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/07/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 09
STATE MECH DBPR SURCHARGE 2 . 09
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 139 . 00 139 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 18 4 . 18 . 00 . 00
Grand Total 143 . 18 143 . 18 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
O�n Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: 1`) 00 o 61 ee l� e- Do U e , PERMIT#
PROJECT VALUE $
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI# 3 7D5Cx95�3-7b5 103
Air Conditioning: Unit Quantity 2 Tons Per Unitl d-3 704 REQUIRED
Heat: Unit Quantity— BTU's Per Unit Seer Rating I �J Ser,
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER: 3 N�uZ 1 (Z
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
I'>
Property Owners Name >ChW
e ��{ a h G yJ _Phone Number (941- 2
Mechanical Company AG k-'(w Office Phone!a]-�-QWJ Fax
Co. Address: H 2j I (� e rSlm City State EL Zip 32 3
License Holder (Print): .,-` . ►. �-�- State Certification/Registration#CV'(1C1Z�l�q 3°I
i
Notarized Signature of License Holder
Sworn and subscribed before nKf9is � ✓ 20-a
Signature of Notary Public Nota P tl-�
r 8
Commission No.EE 84823
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
Amin Wmad CERTIFIED,. between Feb 17, 2009 and Dec 31, 2013.
www.ahridirectory.org A'
Certificate of Product Ratings
AHRI Certified Reference Number: 3705103 Date: 10/7/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 15PJL36
Indoor Unit Model Number: RHLL-HM3617+RCSL-H*3617
Manufacturer: RHEEM MANUFACTURING COMPANY
Trade/Brand name: RHEEM 15PJL SERIES
Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 35400
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh) @ 47 F: 34600
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh) @ 17 F: 22200
'Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating,
click on"Verify Certificate"link and entertheAHRI Certified Reference Numberand the date on &On .n ,' and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130256473985337920
This combination qualifies for a Federal Energy
0% Ulm
Efficiency Tax Credit when placed in service
9%1 smal CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013.
www.ahridirecory.org
Certificate of Product Ratipgs
AHRI Certified Reference Number: 3705065 Date: 10/7/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 15PJL30
Indoor Unit Model Number: RHLL-HM3617+RCSL-H*3617
Manufacturer: RHEEM MANUFACTURING COMPANY
Trade/Brand name: RHEEM 15PJL SERIES
Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity(Btuh): 28800
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh) @ 47 F: 27200
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh) @ 17 F: 16300
Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, w "IM Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 01W am `' and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
92013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130256477089897120
Designstar Load Calculation
Results are intended for use with Rheem heating and cooling systems
'customer • •
Street Address 90 OCEANBREEZE DRIVE, Atlantic Beach, FL
32233
..................................._..........._......._..._.._.._................_..........._...._._ ._ _.._.........._...................._........................................................................._._................._......................................_..._.._.._..._.._
Latitude, Longitude 30.3375°, -81.7686°
House Square 3327 sq. ft.
Footage:
Name: LARRY & MICHELLE WALSHAW
Phone: 904-247-0021
---........................_...__...._. ............___._........ ..__.........._.._._........................................................................................................................................................__......._..........
Email:
.._..........._........................................._......._.........................._..........._............_...................._......._..._........_.___
'House • . •
SHR .75
Number of residents 2
............._.._......................-......................_............................_....................._..........._........................._........................................................--..._......._......._................_........................._......._..........._.._..._........
Ceiling height 9
Wall U-value R-value 0.09111
........................................................................................_......................................_............................_...................................__......................................_.............
...........
Floor U-value R-value 0.2 15
Ceiling U-value I R-value 0.053 119
................_.._..._.....1--....................._........................................................_.._.._......._.._............_.._..._....._.........................................................._.............................................................._.._...............
.....
Window U-value 0.5
Window SHGF 0.85
....._.._..._.._..._.............................................................................---............-...._.................................................................................._......._.._....................._...................................
Moisture grains 53
Duct loss % 10
1----.-.-...1 __............ ............_........................,......_......................................................................................_................_............................__................................................................ .............
Duct gain % 10
Cooling infiltraction (ACH) 0.6
_. ................._........................................-...........................................I................1-1--...........................I............................................... 11............ .........................................
Heating infiltration (ACH) 0.8
Winter ventilation 0
_............I-_................................................._.................................................._........._..._................................__..._..........._........_..............._......._..._......_......._..._.................................._.._........_.._.._........
Design Conditions
Outdoor Heating Cooling
Dry bulb (°F) 32 93
Daily range M
Relative humidity 50%
Moisture difference 53
IndoorHeating Cooling
Indoor temperature (°F) 70 75
Design temperature differenceff) 38 18
[Heating Load
Area Btuh % of load
............... re ................._............._............................._...........
Wall 5467 9.4
.........................................................................................................._...................................._.............................................
Floor 15930 27.5
Ceiling 6701 11.6
Windows 9082 15.7
Infiltration 15520 26.8
......................................................................_...................................._..........................._................
System Efficiency Loss 5270 9.1
Total: 57969
Heating Loads
57,969 BTU/hr
r System Efficiency Loss
Floor� A111-Wall
Ceiling
Windows
Infiltration J
ooling Loads
Area Btuh % of load
.............................................. .
Wall 4028 6.3
Ceiling 9346 14.6
................ .................... _..................._..._.
Windows 23300 36.4
_......._......_..............-....................._......__..............._.....-.................._....._...............
........._......_.........._._.
Sensible Infiltration 5514 8.6
.............................._..........._..................................................._.................................._...........................................
Latent Infiltration 10036 15.7
System Efficiency Gain 5222 8.2
_ ..............
.
Internal 5656 8.8
............._........._.........................................._.................................._.........._...._..
Sensible People Load 460 0.7
.........................................._..._..................................._..........................................
_
Latent People Load 460 0.7
Total: 64022
Sensible load 53526
Latent load 10496
SHR 0.84
Capacity at .75 SHR 5.95 Tons .
Cooling Loads
64,022 BTU/hr
it
Sensible People Load
Latent People Load
---Wall
System Efficiency Gain
Windows
Sensible Infiltratioi
Internal
Ceiling
Latent Infiltration
AED Graph
aonoo '�
30000
20000 —
J iI
10000
0 8am 9am r loam Ilam 12pm 1pm 2pm 3pm 4pm Spm 6pm 7pm 8pm
—Hourly Loads —Average
i
• • •
System equipment selection will be made using the following derived values.
Glass (SW) 241 sq. ft.
---..........-.1.............-.—......... -
Glass (NW) 34 sq. ft.
....I--.................................................................................................
Glass (SE) 34 sq. ft.
......................................_................ ._........................................................_......
Glass (NE) 169 sq. ft.
................,....................- ...............................................................
Summer Outdoor 930F
_....._.._...._................................._.._.._.._.._.._._
Summer Wet Bulb 77°F
................................._..-......_....................._...............................................................-.............._....................._........................_....
Summer Indoor 750F
_..........._.._.._._..._........_.._..._....................._._.._..._.._._.............
Summer Design Grains 50%
........................................_..........._...................._..._.._........................._........................._................................................
Winter Outdoor 320F
... ..
. _.._..
WinterIndoor d oo r _._.._..._.......___.
70°F
_................ _......................._.._.._.._._.._.._....................................................................._..._._.._...._...._........................................
Sensible Cooling 53,526 Btuh
................................................._.._........_.._... _.._.._..._.
Latent Cooling 10,496 Btuh
............. .._ __._.._..._.... .... .. ........._......___.........
-111-1
Required Cooling Airflow 2,433 CFM
Sensible Heating 57,969 Btuh
-.._.._.._._.._.._.._
...........
..
...._............
.....
........
.._.._.._........................
.......
........
..-----------
..._._.._._._
................. ............................._.__.._...................._...__.._._......._.
Required Heating Airflow 753 CFM
--.1.................. ........................................-- --.............................. ...........
All calculations are based upon approved hvac industry standards and procedures,and comply with all local,
state and federal code requirements.All computed results are Estimates.Product provided by Energy Design
Systems and Idea Tree
'raj!y-L`Jfj��
CITY OF ATLANTIC BEACH
s f 800 SEMINOLE ROAD
r� ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003679 Date 11/19/13
Property Address . . . . . . 90 OCEAN BREEZE DR
Application type description ELECTRIC ONLY
Property Zoning . . . . . . . RES GEN MF DISTRICT
Application valuation . . . . 0
-----------------------------------
Application desc
breaker chg for ac
---------------------------------
Owner Contractor
----------
------------------------ --------------
WALSHAW, LARRY E * MICHELLE AMERICAN ELECTRICAL CONTRACTOR
90 OCEAN BREEZE DR 5065 ST. AUGUSTINE RD #13
ATLANTIC BEACH FL 322335953 JACKSONVILLE FL 32207
(904) 737-7770
---------- -----------------------------------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . • plan Check Fee . 00
Permit Fee . . . . 60 . 00 0
Issue Date Valuation
Expiration Date . . 5/18/14
_ _ ------
Other Fees
STATE ELEC DCA SURCHARGE 2 . 00
STATE ELEC DBPR SURCHARGE 2 . 00
_ ________ ----
Fee summary Charged
Paid Credited ----Due---
_ _ ------ -
----------
----------
Permit Fee Total 60 . 00 60 . 00 00 . 00
00 . 00
Plan Check Total . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00
Grand Total
64 . 00 64 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd, Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
b,,,3 ADDRESS: � `� �C�io �ruf z� PERMIT#
JEA INFORMATION REQUIRED ON ALL PERMITS GU' AMPS �� VOLTS PHASE
VAL UE OF WORK$
NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole
-Residential(Main) Service s #of Meters
- am
0-100 amps -101-150amps E 151-200amps P
Commercial(Main) Service
--0-100 amps -101-150amps E 151-200amps amps CT Service amps
Conductor Type Size
Multi-Family(Main) Service
-0-100 amps 101-150amps " 151-200amps amps #of Unit Meters
Temporary Pole =- amps
SERVICE UPGRADE i amps - CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
-100 amps C�150amps 200amps - amps -CT Service amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-30amps 31-100amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS
Swimming Pool Sign Cl Smoke Detectors_Qty ETransformers KVA Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK$—1010
Qty volts/amps
REPAIRS/MISCELLANEOUS
Replace Burnt/Damaged Meter Can Safety Inspection Panel Change -OH to UG
Other:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction.
Property Owners Name
tr ;L�,� ��, 5 �,I r Phone Number t l
Electrical Company American Electrical Contracting, INC Office Phone 904-737-7770 Fax
Co. Address: 5065-3 St Augustine Rd 71 I'll, City Jacks ville State FL Zip 32207
L'- -ase Holder (Print):Earl W. Frick ification/Registration# ER0015 3l b
D P
er ,
Notery Public State of Florida 20
'' ; Anna M Daly orn and subscribed be re�lthis day of
My Commissloo EE 850790
' � Expireeo1012017 ature of Notary Pub *c