Loading...
473 Sturdivant Ave 2013 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 moil >? Application Number . . . . . 13-00003531 Date 10/16/13 Property Address . . . . . . 473 STURDIVANT AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SNYDER, WILLIAM NORTHPORT CONSTRUCTION GROUP 473 STURDIVANT AVE NORTHPORT HGT AND AIR ATLANTIC BEACH FL 322334037 1873 EVERLEE RD JACKSONVILLE FL 32216 (907) 731-8248 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/14/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 1 Ph(904) 247--5826 Fax (904) 247-5845 JOB ADDRESS: L-1-13 CJ \VAC��UO�`C1 ` ��. Q�C\ �;c"'beO,� PERMIT# �L 3a a33 PROJECT VALUE $ �j.�-I00 .� ARI# 1 a`7a 13 (o REQUIRED Air Handling Equipment Only __Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit a•r5 Heat: Unit Quantity 1 BTU's Per Unit 30, O O O Seer Rating 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ljLY;\N� 0\m '20\1 -P—S- Phone Numbe�14 A S�M Y-`7 9/6 Mechanical Company ►V n< yRCw 11 � �(Cy�C��Un�ffice Phone"731 - aq.$Fax`731 - ���9 db0.= Noc�h�to�t Neo.��c,q p,:c coc.d:t,��n;n Co.Address: -1?)mac'1 CityState L zip '392/to License Holder(Print): (- C' Q State Certification/Registration#( .M C 10150 o39 Notarized Signature of License Holder ALMIR HADZIC Before me this)—day of OC TO a 6/Z 20 l.3 MY COMMISSION 0 EE86MW Signature of Notary Public ,q R 1-1�q O 2-t C EXPIRES January 22.2017 Residential System Sizing Calculation Summary William Snyder Project Title: 473 Sturdivant Blvd 473 Sturdivant Blvd Altantic Beach, FL 32233- 10/14/2013 Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH 5=;F wet bulb 77F Humidit difference 53 r. Winter design temperature(MSummer design temperature(MJ8 99%) 93 F Winter setpoint Summer setpoint75 F Winter tem erature difference Summer tem erature difference 18 F Total heatin load calculatih Total coolin load calculation 26609 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 143.1 28800 Sensible (SHR = 0.75) 102.9 21600 Heat Pump+Auxiliary(O.OkW) 143.1 28800 Latent 127.9 7200 Total Electric Heat Pum 108.2 28800 WINTER CALCULATIONS Winter Heating Load for 1220 s Load component Load A� Window total 131 sqft 2489 Btuh Wall total 1526 sgft 3034 Btuh Door total 39 sqft 682 Btuh n ,,�w F] ISM Vallar'I'_9e:' Ceiling total 612 sqft 741 Btuh Floor total See detail report 5157 Btuh , Infiltration 173 cfm 7212 Btuh Duct loss 811 Btuh Subtotal 20126 Btuh Ventilation 0 cfm 0 Btuh °° s, Fmors zaa4; TOTAL HEAT LOSS 20126 Btuh SUMMER CALCULATIONS Summer Cooling Load for 1220 s ft Load component Load Window total 131 sqft 6086 Btuh Wall total 1526 sqft 1797 Btuh Door total 39 sqft 520 Btuh Ceiling total 612 sqft 1423 Btuh Floor total 0 Btuh i �� �•.5,� Infiltration 130 cfm 2562 Btuh 1n- Internal gain 7090 Btuh Duct gain 1403 Btuh Sens.Ventilation 0 cfm 0 Btuh Blower Load 100 Btuh Total sensible gain 20981 Btuh yrs W.IN 7_— Latent gain(ducts) 364 Btuh Latent gain(infiltration) 4664 Btuh Latent gain(ventilation) 0 Btuh W,_;27%; Latent gain(internal/occupants/other) 600 Btuh Total latent gain 5628 Btuh TOTAL HEAT GAIN 26609 Btuh EnergyGauge®System Sizing ry,r— PREPARED BY: 8th Edition DATE: EnergyGauge®/USRFZB 0.1 System Sizing Calculations - Winter Residential Load - Whole House Component Details William Snyder Project Title: 473 Sturdivant Blvd 473 Sturdivant Blvd Altantic Beach, FL 32233- Building Type: User 10/14/2013 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.50 Metal 0.50 N 15.0 19.0 285 Btuh 2 2, NFRC 0.50 Metal 0.50 S 15.0 19.0 285 Btuh 3 2, NFRC 0.50 Metal 0.50 S 30.0 19.0 570 Btuh 4 2, NFRC 0.50 Metal 0.50 N 15.0 19.0 285 Btuh 5 2, NFRC 0.50 Metal 0.50 W 52.0 19.0 988 Btuh 6 NFRC 0.50 Metal 0.50 W 4.0 19.0 76 Btuh Window Total 131.0 s ft 2489 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood - Ext (0.084) 15.0/0.0 102 3.19 324 Btuh 2 Frame-Wood - Ext (0.084) 15.0/0.0 102 3.19 324 Btuh 3 Frame -Wood - Ext (0.084) 15.0/0.0 236 3.19 754 Btuh 4 Frame -Wood - Int (0.240) 0.0/0.0 288 0.00 0 Btuh 5 Frame-Wood - Ext (0.084) 15.0/0.0 106 3.19 339 Btuh 6 Frame-Wood - Ext (0.084) 15.0/0.0 121 3.19 386 Btuh 7 Frame -Wood - Ext (0.084) 15.0/0.0 284 3.19 907 Btuh 8 - Int (0.084) 15.0/0.0 288 0.00 0 Btuh Wall Total 1526 s ft 3034 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, n (0.460) 20 17.5 341 Btuh 2 Insulated - Exterior, n (0.460) 20 17.5 341 Btuh Door Total 39 s ft 682Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/L/Shing (0.032) 30.0/0.0 612 1.2 741 Btuh Ceiling Total 612 s ft 741 Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 115.0 ft(perim.) 44.8 5157 Btuh 2 Interior (1.180) 0.0 612.0 sqft 0.0 0 Btuh Floor Total 1218 s ft 5157 Btuh Envelope Subtotal: 12102 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 1.06 9760 1.00 172.7 7212 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (DLM of 0.042) 811 Btuh All Zones Sensible Subtotal All Zones 20126 Btuh EnergyGauge®/USRFZB v3.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) William Snyder Project Title: 473 Sturdivant Blvd 473 Sturdivant Blvd Altantic Beach, FL 32233- Building Type: User 10/14/2013 KHOLEHOUS�TO ALS Subtotal Sensible Heat Loss 20126 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 20126 Btuh EQUIPMENT F1. Electric Heat Pump AirTemp#VT4BD-030K J72�Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) , U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge®/USRFZB v3.1 Page 2 System Sizing Calculations - summer Residential Load - Whole Nouse Component Details William Snyder Project Title: 473 Sturdivant Blvd 473 Sturdivant Blvd Altantic Beach, FL 32233- 10/14/2013 Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr. Component Loads for Whale House Type" Overhang Window Area(sqft) HTM Load Wind�T2 nes SHGC U InSh IS Omt Len H t Gross Shaded Unshade Shaded Unshaded 1NFRC 0.50,0.50 No No N 4.Oft 2.Oft 15.0 0.0 15.019 19 292 Btuh 2NFRC 0.50,0.50 No No S O.Oft O.Oft 15.0 0.0 15.0 19 24 358 Btuh3NFRC 0.50,0.50 No No S O.Oft 0.0ft 30.0 0.0 30.0 19 24 715 Btuh 4 2 NFRC 0.50,0.50 No No N 2.0ft 3.Oft 15.0 0.0 15.0 19 19 292 Btuh 5 2 NFRC 0.50,0.50 No No W 2.Oft 2.Oft 52.0 0.0 52.0 19 57 2969 Btuh 6 BlockNFRr50,0.50 No No W O.Oft 0.0ft 4.0 0.0 4.0 19 57 1232 Btuh Excursion Window Total 131 (sqft) 6086 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Ext 0.08 15.0/0.0 101.5 1.9 192 Btuh 2 Frame-Wood-Ext 0.08 15.0/0.0 101.5 1.9 192 Btuh 3 Frame-Wood-Ext 0.08 15.0/0.0 236.0 1.9 446 Btuh 4 Frame-Wood-Int 0.24 0.0/0.0 288.0 0.0 0 Btuh 5 Frame-Wood-Ext 0.08 15.0/0.0 106.0 1.9 200 Btuh 6 Frame-Wood-Ext 0.08 15.0/0.0 121.0 1.9 229 Btuh 7 Frame-Wood-Ext 0.08 15.0/0.0 284.0 1.9 537 Btuh 8 -Int 0.08 15.0/0.0 288.0 0.0 0 Btuh Wall Total 1526 (sqft) 1797 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 19.5 13.3 260 Btuh 2 Insulated-Exterior 19.5 13.3 260 Btuh Door Total 39 (sqft) 520 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1423 Btuh 1 Unvented Attic/Light/Shingle 0.032 30.0/0.0 612.0 2.32 1423 Btuh Ceiling Total 612(sqft) Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 606(ft-perimeter) 0.0 0 Btuh 2 Interior 0.0 612(sqft) 0.0 0 Btuh Floor Total 1218.0 (sqft) 0 Btuh Envelope Subtotal: 9825 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.80 9760 1 129.5 2562 Btuh IntemaI Occupants Btuh/occupant Appliance Load ain 3 X 230 + 6400 7090 Btuh Sensible Envelope Load: 19478 Btuh DGM of 0.072 1403 Btuh fDuctadffAveragesealed, upply(R6.0-Attic),Retum(R6.0-Attic) ( ) Sensible Load All Zones 20881 Btuh EnergyGauge®/USRFZB 0.1 Pagel Manual J Summer Calculations Residential Load - Component Details (continued) William Snyder Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 473 Sturdivant Blvd 473 Sturdivant Blvd Altantic Beach, FL 32233- 10/14/2013 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 19478 Btuh Sensible Duct Load 1403 Btuh Total Sensible Zone Loads 20881 Btuh Sensible ventilation 0 Btuh Blower 100 Btuh Whole House Total sensible gain 20981 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 4664 Btuh Latent ventilation gain 0 Btuh Latent duct gain 364 Btuh Latent occupant gain (3.0 people @ 200 Btuh per person) 600 Btuh Latent other gain 0 Btuh Latent total gain 5628 Btuh TOTAL GAIN 26609 Btuh EQUIPMENT 1. Central Unit AirTemp#B6BMM-030K-A 28800 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Drapehes(D)or Roller Shades(R)) - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N),Full(F)or Half('/z)) (Ornt-compass orientation) Version 8 EnergyGauge®/USRFZB v3.1 Page 2 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 473 Sturdivant Blvd Builder Name: North Port Heating and A/C Street: 473 Sturdivant Blvd Permit Office: City,State,Zip: Altantic Beach,FL,32233- Permit Number: Owner: William Snyder Jurisdiction: Design Location: FL,Jacksonville 1. New construction or existing Existing(Projecte 9. Wall Types(1696.0 sqft.) Insulation Area a.Frame-Wood,Exterior R=15.0 1120.00 ft' 2. Single family or multiple family Single-family b.Interior Frame-Steel,Interior R=15.0 288.00 ft' 3. Number of units,if multiple family 1 c.Interior Frame-Wood,Interior R=0.0 288.00 ft' 4. Number of Bedrooms 2 d.N/A R= ft' 10.Ceiling Types (612.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=0.0 612.00 ft' 6. Conditioned floor area above grade(ft') 1220 b.N/A R= ft' c.N/A R= ft' Conditioned floor area below grade(ft') 0 11.Ducts R ft' 7. Windows(131.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 50 a. U-Factor: Dbl,U=0.50 127.00 ft' SHGC: SHGC=0.50 kBtu/hr Efficient ft' 12.Cooling systems Y b. U-Factor: Gbl,default 4.00 a.Central Unit 28.8 SEER:13.00 SHGC: Clear,default c. U-Factor: N/A ft' SHGC: 13.Heating systems kBt Efficiency 28. d. U-Factor: N/A ft' a.Electric Heat Pump 28.8 HSPF:8.00 SHGC: Area Weighted Average Overhang Depth: 1.481 ft. Area Weighted Average SHGC: 0.500 14.Hot water systems a.Electric Cap:38 gallons 8. Floor Types (1218.0 sqft.) Insulation Area EF:0.920 a.Floor Over Other Space R=0.0 612.00 ft' b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 606.00 ft' None c.N/A R= ft' 15.Credits CF,Pstat Total Proposed Modified Loads: 23.86 PASS Glass/Floor Area: 0.107 Total Standard Reference Loads: 29.72 I hereby certify that the plans and specifications covered by Review of the plans and ©"q1"AE this calculation are in comp'ance ith a Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. .,r,;E '' •"`'i PREPARED BY: Before construction is completed -� DATE: this building will be inspected for compliance with Section 553.908 Florida Statutes. 5'4 I hereby certify that this bu'din , as designed, is in compliance CSD W-E � with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 10/14/2013 8:02 PM 9Y 9 Ener Gau e®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: 473 Sturdivant Blvd Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1220 Lot# Owner: William Snyder Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: North Port Heating and A/C Rotate Angle: 180 Street: 473 Sturdivant Blvd Permit Office: Cross Ventilation: No County: Duval Jurisdiction: Whole House Fan: No City,State,Zip: Altantic Beach, Family Type: Single-family FL, 32233- New/Existing: Existing(Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1220 9760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st floor 606 4848 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 612 4896 No 2 1 1 Yes Yes Yes 3 adj space 1 st floor 1 8 No 0 0 1 Yes Yes Yes 4 adj space 2nd floor 1 8 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1 st floor 115 ft 0 606 ft2 0 0 1 2 Floor Over Other Space 2nd Floor ____ ____ 612 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 645 ft2 102 ft2 Medium 0.96 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 612 ft2 N N 10/14/2013 8:02 PM 9Y 9 Ener Gau eS USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) 2nd Floor 30 612 ft' 0.11 Wood WALLS Cavity Width Height Sheathing Framing Solar Below Adjacent Space a _ R-Vahle Ft In Ft In Arpa 1 N=>S Exterior Frame'-Wood 1 st floor 15 17 0 8 136.0 ft' 0.23 0.75 0 _2 S=>N Exterior Frame-Wood 1 st floor 15 17 0 8 136.0 ft2 0.23 0.75 0 _3 E=>W Exterior Frame-Wood 1 st floor 15 36 0 8 288.0 ft' 0 0.23 0.75 0 4 W=>E adj space Interior Frame-Wood 1 st floor 0 36 0 8 288.0 ft' 0 0.23 0.75 0 _ 5 N=>S Exterior Frame-Wood 2nd Floor 15 17 0 8 136.0 ft2 0.23 0.75 0 _6 S=>N Exterior Frame-Wood 2nd Floor 15 17 0 8 136.0 ft' 0.23 0.75 0 _7 E=>W Exterior Frame-Wood 2nd Floor 15 36 0 8 288.0 ft' 0 0.23 0.75 0 8 W=>E adj space Interior Frame-Steel 2nd Floor 15 36 0 8 288.0 ft' 0 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>N Insulated 1st floor None .46 3 6 6 19.5 ft2 2 N=>S Insulated 1 st floor None .46 3 6 6 19.5 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 180 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>N 2 Metal Double(Clear) Yes 0.5 0.5 15.0 ft' 4 ft 0 in 2 ft 0 in Drapes/blinds None 2 N=>S 1 Metal Double(Clear) Yes 0.5 0.5 15.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 3 N=>S 5 Metal Double(Clear) Yes 0.5 0.5 30.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 4 S=>N 6 Metal Double(Clear) Yes 0.5 0.5 15.0 ft' 2 ft 0 in 3 ft 0 in Drapes/blinds None 5 E=>W 3 Metal Double(Clear) Yes 0.5 0.5 52.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None 6 E=>W 7 Metal Glazed Block Yes 0.5 0.5 4.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA Eq LA ACH ACH 50 1 Wholehouse Best Guess .0007 2240.1 122.98 231.27 .6636 13.770 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8 28.8 kBtu/hr 1 sys#1 10/14/2013 8:02 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:13 28.8 kBtu/hr 864 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1 st floor 0.92 38 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS —Supply— — RReturn— Air CFM 25 CFM25 HVAC# / V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 50 ftz Attic 30 ft' Default Leakage 2nd Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan [ ]Feb Mar [ ]Apr May [X]Jun ri Jul ri Aug �xl Sep [ ]Oct Nov Dec Heating Jan )Feb Mar [ ]Apr l May [ ]Jun Jul AugSeP []Oct Nov Dec Venting Jan [ ]Feb X Mar [X]A r [ Ma [ ]Jun Jul Aug Se [X]Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 68 68 66 68 68 68 66 66 8 68 68 68 68 68 66 66 Heating(WEH) PM 68 68 68 68 68 68 68 68 68 68 66 66 9Y 10/14/2013 8:02 PM Ener Gauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 473 Sturdivant Blvd PERMIT#: Altantic Beach, FL, 32233- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers,filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to= R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 9Y 10/14/2013 8:02 PM Ener Gauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index,the more efficient the home. 473 Sturdivant Blvd, Altantic Beach, FL, 32233- 1. New construction or existing Existing(Projecte 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=15.0 1120.00 ft' 2. Single family or multiple family Single-family b.Interior Frame-Steel,Interior R=15.0 288.00 ft' 3. Number of units,if multiple family 1 c.Interior Frame-Wood,Interior R=0.0 288.00 ft' d.N/A R= ft' 4. Number of Bedrooms 2 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Roof Deck(Unvented) R=0.0 612.00 ft' 6. Conditioned floor area(ft') 1220 b.N/A R= ft2 c.N/A R= ft 7. Windows- Description Area 11.Ducts R ft' a. U-Factor: Dbl,U=0.50 127.00 ft' a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 50 SHGC: SHGC=0.50 b. U-Factor: Gbl,default 4.00 ft' Clear,default 12.Cooling systems kBtu/hr Efficiency SHGC: ft' a.Central Unit 28.8 SEER:13.00 c. U-Factor: Clear, SHGC: d. U-Factor: N/A ft' 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.8 HSPF:8.00 Area Weighted Average Overhang Depth: 1.481 ft. Area Weighted Average SHGC: 0.500 8. Floor Types Insulation Area 14.Hot water systems Cap:38 gallons a.Floor Over Other Space R=0.0 612.00 ft' a.Electric EF:0.92 b.Slab-On-Grade Edge Insulation R=0.0 606.00 ft' b. Conservation features c.N/A R= ft' None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building QfgE STgT� Construction through the above energy saving features which will be installed (or exceeded) � p in this home before final inspectiontherwise, a new EPL Display Card will be completed y '1„ based on installed Code compli atures. Builder Signature: _ Date: Address of New Home: �j'�3 LT t/R 0,11-A"s STR City/FL Zip: V7-t4,f7 i r Q 6 WE 3221>1 *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software