1178 Ocean Blvd 2013 HVACCITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003541 Date 10/17/13
Property Address . . . . . . 1178 OCEAN BLVD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner
ROGERS NICHOLAS W ET AL
ROGERS TAYLOR P & PERRY THOMAS
1178 OCEAN BLVD
ATLANTIC BEACH FL 32233
Contractor
DONOVAN HEATING & AIR
315 SIXTH AVENUE SOUTH
JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . .
. MECHANICAL
HVAC PERMIT
Additional desc .
.
Permit Fee . . .
. 103.00
Plan Check Fee
.00
Issue Date . . .
.
Valuation . . . .
0
Expiration Date .
. 4/15/14
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
STATE MECH DCA SURCHARGE
2.00
STATE MECH DBPR SURCHARGE
2.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
103.00
103.00 .00
.00
Plan Check Total
.00
.00 .00
.00
Other Fee Total
4.00
4.00 .00
.00
Grand Total
107.00
107.00 .00
.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
10B ADDRESS: - Ocean
PERMIT #
PROJECT VALUES 3 FjWcro
ARI #. 3 (,'7 0 fir, 7 Z REQUIRED
Air Handling Equipment Only -/'OAir Handling Unit & Condenser Condenser Only
JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity
Tons Per Unit
Heat: Unit Quantity
BTU's Per Unit Seer Rating
Duct Systems: Total CFM
REQUIRED
ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity
Tons Per Unit 3•S
s
Heat: Unit Quantity I
BTU's Per Unit y2 0-ao Seer Rating
Duct Systems: Total CFM
REQUIRED
IRE PREVENTION
Fire Sprinkler System Quantity
(Requires 3 sets of plans)
Fire Standpipe Quantity
(Requires 3 sets of plans)
Underground Fire Main Value
(Requires 3 sets of plans)
Fire Hose Cabinets Quantity
(Requires 3 sets of plans)
Commercial Hoods Quantity
(Requires 3 sets of plans)
Fire Suppression Systems Quantity
(Requires 3 sets of plans)
+IRE PLACES
MISCELLANEOUS:
Prefabricated Fireplace Qty
Automobile Lifts
Gas Piping Outlets
Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING
Heat Exchanger
Quantity of Outlets
Pumps
# Vented Wall Furnaces
Refrigerator Condenser BTU's
# Water Heaters
Solar Collection Systems
Tanks (gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners Nam -e- J i CK � n ►7fJ/ 9 Phone Number Z33 - 57h �
Mechanical Company _J�nvDU� /tF)2i f %1►,% Office Phone:ZV/ 3W _ Fax 2YI37y5
:o. Address: 3�5 Ate- s City �� �Gi State Zip 23 2S'D
.icense Holder (Print): State Certification/Registration # 6A C,(5 39'76
Notarized Signature o License Holder
A.0-
L%
day of 20—
RICHARD TOMPKINS
Commission # FF 040399 Before me this
Expires July 29, 2017
Bonded TMuTmyFain Im mce800,1"19 Signature of Notary Public
+ wrightsoft Proiect Summary
Entire House
Donovan Heat & Air
Job:
Date: October 14, 2013
By: Aaron Thacker
315 6th Ave S, Jacksonville Beach, FL 32250 Phone 904-241-3785 Fax: 904241-3745 Email: aaron@donovanac.com Web: www.DonovanAC.com
Project! •
For: Nick Rogers
1178 Ocean Blvd, Atlantic Beach, FL 32233
►fr47171
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db
39 OF
Inside db
70
OF
Design TD
31
OF
Heating Summary
in H2O
Structure
21368
Btuh
Ducts
4033
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
25401
Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Heating Cooling
Area (ft') 1931 1931
Volume (ft) 15444 15444
Air changes/hour 0.38 0.20
Equiv. AVF (cfm) 98 51
Heating Equipment Summary
Make Tempstar
Trade 15 SEER N SERIES R41 OA HP
Model NXH542GKA"
AHRI ref no3670872
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
8.7 HSPF
36800
Btuh @ 47°F
24
OF
1383
cfm
0.054
cfm/Btuh
0
in H2O
Outside db
99 OF
Inside db
75 OF
Design TD
24 °F
Daily range
L
Relative humidity
50 %
Moisture difference
69 gr/Ib
Sensible Cooling Equipment Load Sizing
Structure 21470 Btuh
Ducts 6962 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 1.04
Equipment sensible load 29569 Btuh
Latent Cooling Equipment Load Sizing
Structure 2616 Btuh
Ducts 1922 Btuh
Central vent (0 cfm) 0 Btuh
Equipment latent load 4538 Btuh
Equipment total load 34107 Btuh
Req. total capacity at 0.75 SHR 3.3 ton
Cooling Equipment Summary
Make Tempstar
Trade 15 SEER N SERIES R41 OA HP
Cond NXH542GKA`
Coil FXM4X42'"A'
AHRI ref no3670872
Efficiency 12.5 EER,
15 SEER
Sensible cooling
31125
Btuh
Latent cooling
10375
Btuh
Total cooling
41500
Btuh
Actual air flow
1383
cfm
Air flow factor
0.049
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.86
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft2013-Oct-1511:49:14
Right -Suite® Un vernal 8.0.24 RSU05995 Page 1
ACCN C:\Users\Owner\Documents\Wdghtsoft HVAC\Bogus 3.5 ton. rup Calc = MJ8 Front Door faces: E