Loading...
2196 Fairway Villas N 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 R Application Number . . . . . 13-00003537 Date 10/17/13 Property Address . . . . . . 2196 N FAIRWAY VILLAS LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVY FEDERAL CREDIT UNION TROPIC HEATING & AIR 820 FOLLIN LN 750 MAYPORT RD VIENNA VA 22180 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 9S . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/15/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JoB ADDRESS: �Z 6 -7 P, PERAUT # 9-7-7( PROJECT VALUE $ -0 ARr# —196*@P 9" REOUTRED Air Handling Equipment Only _�' Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Un!t Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQLTRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 1--, 5- Heat: Unit Quantity BTUs Per Unit S, Seer Rating 0 Duct Systems: Total CFM REQUTRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTUs Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps 9 Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: r )j AAQj *,", ?Ie4,�e ev/.",Cz- Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct- All provisions of laws and ordinances governing this work will be complied with whether specified or not. 'Me permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Cy-d'l 4P-0 Phone Number 9 Oq -ILf 1,F- Lf e) Mechanical Company TROPIC HEATING& AIR COND., INC. Office Phone 904-241-1788 Fax904-241-2172 Co. Address: 750 MAY"PORT ROAD _ City ATLANTIC BCH State FL Zip 32233 License Holder(Print): CIURLES J MARKS. Atate f, at'on/Registration# CAC052431 Notarized Signature ofLicense Holder----I �A X-11 - KAREN E.PANTFOEDER Before me this dayof Octl9er 20 13 NOTARY PUBLIC STATE OF FLORIDA Signature of Notary Publi�—� Comm#EE064448 Expires 3/4/2015 r Hficate of Produd Raiil AHRI Certified Reference Number: 5358271 Date. 10/16/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ1 30301A* Indoor Unit Model Number:ARUF301314A* Manufacturer: GOODMAN MANUFACTURING CO., LP. TradWBrand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND X Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (13tuh): 27200� EER Rating (Cooling).- 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F.- 27000 Region IV HSPF Rating (Heating): 8.0D Heating Capacity(Btuh) Cd 17 F: 16500 Rdings fdlov�ed byan a-Aed_sk�"Ordicatea unlessa-ccunpinied vvtha'Wn�S.which hdic,,,�tersan invdurdziry remte. DISCLAIMER AHRI does not endarse the product(s�fisted on this Certificate arid maket,110 tepresentati(xis,viar;anliesor guarantees"to,and assurnas no ieWo risibility for, theproduLt(s)IisbA on this Cediticate.Ali Ri expressly disclawris all liabilftyfordarnaW.sofazyy kinddriSing0it OftheUSC04 perfarn-mnceof1heproduct(a),orthe unaulhorizvd altex-ation C(data listed onthisceitiWate,Certzfi�,d ralfingsarevalid twit rg. _V for xmidels and configurations li-Ok�.d in the diiectooy at�_�wmearinairectoty.o TERMS AND CONDITIONS This Certificate and its cartents ai e propfietary producl,;�of AHRL This CettiO.,dte shall okikv be used fcw individual,persona I anti coriftiential tefes-erice purw.ses. TIV-1 contents ofthis Cestiticate"Y not,in vAw)le oi in part.be Eepcochiced;copii-d;disseminated;enh�red into a corrAmter database;or ottiervase utilized,in any to mi or rranoff or by drzymeans,t*tcept for the user's individtital,pty-Axial and confidential refff- erice. CERTIFICATE VERIFICATION -F or xy I he.infornriation fix the niodel Cited OF)thig certificate can be Vefifi(A bt -,Wa-h Click on link and eniff theAli RI Cerfified Reference N umber and the date on %hich the certificale%m issued.Wfich is WeA above�and the CANtificatello.,W ich is listed bNow A (D2013 Hleatmg,,.-)r�d F:efrige�-ation lrrstltljtc� CERTIFICATE NO.: 1302642-49866365364 Job: Seeley Project Summary Date: 10/1612013 Entire House By: Tropic Heating&Air C... -4 Tropic Heating &Air Conditioning, Inc. 750 Maypoit Rd.,41artic Beach,FL 32233 Phone:904-241-1788 Fa( 904-242-2172 Ernaili TropicacQmsncom License CACO�2431 For: Craig Seeley,Tropic Heating &Air Conditioning,Inc. 2196 Fairway Villas Ln.N.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax 904-241-2172 Email�Tropicac@msn.com Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 'F Inside db 75 *F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20711 Btuh Structure 15110 Btuh Ducts 3701 Btu h Ducts 4819 Btu h Centra I vent(0 cf m) 0 Btu h Centra I vent(0 cf m) 0 Btu h Humidification 0 Btu h Blower 0 Btu h Piping 0 Btu h Equipment load 24412 Btu h Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19929 Btu h M eth od Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2375 Btu h Ducts 428 Btu h Heating Cooling Centra I vent(0 cf m) 0 Btu h Are a(ft2) 1100 1100 Equipment latent load 2803 Btu h Volume(ft) 9900 9900 Air changes/hour 0.58 0.30 Equipment total load 22732 Btu h Equiv.AVF(cfm) 96 50 Req.total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary M ake n/a M ake Trade n/a Trade Model n1a Cond AHRI ref n/a Coil AHRI ref Eff icien cy n1a Eff icien cy 0 SEER Heating input 0 Btu h Sensible cooling 0 Btu h Heating output 0 Btu h Latent cooling 0 Btu h Temperature rise 0 'F Total cooling 0 Btu h Actua I air flow 878 cfm Actual airflow 078 cfm Air flow factor 0.036 cfrrVBtuh Air flow factor O�044 cfrrVBtuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Od-1 612:13:05 + w ri 9b t SOft Rigm-suit e@ u riversal 2013 13.0.06 Righl JO Mobile Pagel ...%vkdmp�605DI825-fblf48aO-963c-e39b27lea6O7.rup Calc=MJ8 FrontDoorfaces: E ig 0 1 e epor NIVEREMPF—Mr� R Date: 10/16/2013 Entire House By: Tropic Heating&Air C.- Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd.,Aflartic Beach,FL 32233 Phone 904-241-1788 F&( 904-242-2172 Email:Tropicac@msnf-om License,CAC052431 Project Information For� Craig Seel ey,Tropic Heating &Air Conditioning,Inc. 2196 Fa irway Vi 11 as Ln.N., Atla nti c Bea ch,FL 32 23 3 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: HWH Cooling Jacksonville/Craig, FL, US I nd oo r te mp eratu re ('F) 7 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30*N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(grilb) 8A 52.8 Dry bul b('F) 35 91 Infiltration: Dailyrange('F) - 17 M Method Simplified Wet bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 N - R; t Component Btu h fif Btu h % of load Walls 3.4 5635 231 S Glazing 19.7 3747 15.3 /Pld Doors 135 283 1.2 Ceilings 1.1 830 3.4 9�1 -Irfiltzicn Floors 8.8 6578 26.9 Infiltration 1.9 3637 14.9 Ducts 3701 15.2 Piping 0 0 Humidification a a "k 1111111111110 Ventilation 0 0 C16 ings Floors Adjustments 0 1 Total 1 1 244121 100.01 Component Btu h At2 Btu h % of load Walls 2.6 4381 22.0 rile Gans Glazing 33.9 6445 32.3 V\dI Doors 11 .4 240 1�2 Ceilings 1.7 1267 6.4 Floors 0 0 0 -.D-ds Infiltration 0.5 886 4.4 Ducts 4819 24.2 Ventilation 0 JkInternal gains 1890 9.5 Blower 0 0 — Irfilbation Adjustments 0 QaZing N Calings I Total 1 199291 100.0 Clher Late nt Co ol ing Lo ad =2 803 Btu h Clverall U-va lu e z 0.146 Btuh/ft�-*F Data entries checked. wrighte;oft 201 3-Od-1 6 12*13*05 R ig M-Su R eOD U ni Y ersal 2013 13.0.06 R ight J @ Mo bile Page 1 X ...lvwhp�60591825-fblf-48aM63c-e39b27lea6O7.rup Calc=MJ8 Front Door faces: E Right-J@ Worksheet Job: Seeley Entire House Date: 10116/2013 Wx"t V 4"q it. Tropic Heating &Air Conditioning, Inc. By: Tropic Heating&Air Condi... 750 Mayport Rd.,Allartic,Beach,FL 32233 Phone:904-2414 788 Fex:904-242-2172 Email:Tropicac@msncom License CAC052431 I Room name E rdire House First Floor 2 Exposed vall 210D A 100D ft 3 Room height 9.0 It d 9.0 It heaVcool 4 Room dimensions 1.0 x 550D 1 5 Room area 11000 ft7 550jo ft, Ty Construction U-Value Or HTM Area (ft 1) Load Area Yt 1) Load number (Bt uhiftl-.F) (BtWft� I or perimeter (ft) (Btuh) I or perimeter 00 (Etuh) I HeElt C ool Gross NAIS Heat Cool Gross NAPS Heat C 6 VL12Msw 0.097 n 3.36 2 61 450 384 1289 1002 270 222 746 580 --.G 1 D-c2ov 0.570 n 19.72 16.61 45 0 887 747 27 0 526 443 11DO 0.390 n 13.49 11.43 21 21 283 240 21 21 283 240 - 2B-0sw 0.097 e 3.36 2.61 495 445 1494 1161 180 162 543 422 11 t—G 11 D-c2ov 0.570 e 19.72 48.13 50 0 986 2406 18 0 362 882 2EI-0 0.097 s 3.36 2 61 450 404 1356 1055 270 243 814 633 t–.G 11 D-c2sowv 0.571) s 19.72 20'.19 46 0 904 925 28 0 542 555 2B-0sw 0.097 w 3.36 2.61 495 446 1496 1163 180 163 545 424 t—G 11 D-c2ov 0.570 w 19.72 48.13 49 0 970 2366 18 0 345 842 c 16B-30ad 0.032 1.11 1.69 750 750 830 1267 200 200 221 338 F 22A-mh 1.358 46.99 0.00 750 140 6578 0 550 100 4699 0 61 c)AED exc�ursion 01 01 Envelope lossigain 1 170741 123341 1 1 96271 53591 12 a) Inlittration 3637 886 1732 422 b) Room ventilation 0 0 0 0 13 internal gains Occupants @ 230 3 690 3 690 A13plianoeslother 1200 1200 Subtotal(lines 6 to 13) 20711 15110 11358 7671 Less eAernal I oad 0 0 0 0 D Redistribution 0 0 0 0 subtatal 20711 151 0 353 7671 5 Duct loads 18% 32% 3701 4819 01 Lesstranster 0 0 14 1 11 1 18%1 32% 2030 2447 Total room load 24412 19929 13388 MIS Air required(c1m) 878 8781 1 4821 4461 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. -4+- vjrighr-'4tifr Right-Suite@Uriversal 2013 13.0.06 Right J@Mobile 2013-Od-1612:13:05 Pagel %v,&tnp%60501825-tlf-48aO-963r-e39b27lea6O7.rup Calc=MJ8 FrortDoorfaces: E Right-J@ Worksheet Job: Seeley Entire House Date: 10/1612013 We #"".A 31 v Tropic Heating &Air Conditioning, Inc. By: Tropic Heating&Air Condi 7501%-Ia�port Rd.,Martic Bead).FL 321233Phone:904-241-1788 Fax:904-242-2172 Email:Tropicac@msnj:!orn License CAC052431 1 Room namp Second Floor 2 E�,posed vW 1 110.0 It 3 Room height 90 ft hPatecool 4 Room-limpn-qons 1.0 x 550.0 it 5 Ro')m area 550.0 ft, T Construcon U-Val ue Or H Tryl Area (ft') Load Ali ea Load number @t uhAt1-'F) (BtuhiW) I or perimeter (1t) (Bt-41h) I or perimeter C ODI H eat --4ross N A1.G H eot C oN Grcic� N P.G H eat oul 6 VL128-Osw 0.097 n 3.36 2.61 180 162 543 422 G I D-c2ov 0.570 n 19.72 16.61 18 0 362 304 11 DO 0.39D n 13.49 11 A3 0 0 0 0 I 2B-O-w 0.097 e 3.36 2.61 315 283 951 739 11 1 D-c2Zv 0570 e 1972 48.13 32 0 621; 1524 213-0'N 0.097 s 3-36 2.61 180 162 543 422 IL-G I D-c2�' 0.570 s 1972 20.19 18 0 362 370 12B-Osw 0.097 w 336 2.61 315 283 951 739 t--C' I D-c2ov M70 w 19.72 48.13 32 0 625 1524 C 16B1230ad 0.032 1.11 1,69 550 550 609 929 F 221Pwh 1.358 46.99 0.00 200 40 IP-79 0 61 c)AED excursion 1 01 1 1 1 Envelope lossJgain 1 7448 1 69741 1 1 1 12 a) Infiltratio 1�11� 464 i b) Room ,entiation U 13 Internal gaina Occupants CW 230 0 n appliancesecyther A Subtotal(lines 6 til 13) 9353 7439 Less eAernal load 0 A Lesstranster 0 0 Redi�ttilzutiori 0 0 14 Subtotal 93,13 7439 Duct loadz: 1671 2373 Total room load 1024 9811 Ar required(cft) 3q7 1 4321 Cal cu latio ns ap prove d bV ACCA to me et al I re qui rements of Manual J Oth Ed� 2013-Oct-1 612 13:05 Right-Suiteel-Inversal 201313.0D6 Right J(DIVIobile Page 2 ...%�-,rtrnp%60501825-fblf-48aO—q63c-e39b2'lea6O7.rup Calc=h4J8 FroftDoorfaces E Job: Seeley Component Constructions Date: 10/16/2013 Entire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd.,Ail arti c Beach,F L 32233 P hone:904-241-1788 F ac 9D4-242-2172 Email:Tropicac@msnicom License CAC052431 ��Y' gwg IF? �MM For: Crai g S eel ey,Tropi c H eating &Air Conditioning,Inc. 2196 Fairway Villas Ln.N., Atlantic Beach,FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (*F) 70 75 Elevation: 43 ft Design TD(T) 35 16 Latitude: 30*N Relative humidity(%) 30 50 outdoor Heating Cooling Moisture difference(gr/lb) 8.4 52-8 Dry bul b(*F) 35 91 Infiltration: Dailyrange('F) - 17 M M eth od Simplified Wet bulb(*F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Constniction descriptions Or Area 1.11-value Insul R Htg HTM Loss Cig HTM Gain t. Btdife-'F t-'FA" 8"te Mull Buh Iff Btuh Walls 12B-Osw:Frm wall,vnI ext,r-1 1 cav ins,112"g ypsum board int n 384 0.097 11.0 3.36 1289 2.61 1002 frish,2"x4"wood frm e 445 U097 11.0 3.36 1494 2.61 1161 s 404 0.097 11.0 3.36 1356 2.61 1055 w 446 0.097 11.0 3.36 1496 2.61 1163 all 1679 0.097 11.0 3.36 5635 2.61 4381 Partitions (none) Windows 1 D-c2ov:2 glazing,cIr outr,air gas,vnI frm mat,cir innr,1/4"gap, n 45 0.670 0 19-7 887 16.6 747 1/8"thk;50%blinds closed,light e 50 0.670 0 19.7 986 48.1 2406 s 46 0.570 0 19.7 904 20.2 925 w 49 0.570 0 19.7 970 481 2366 all 190 0.570 0 19.7 3747 33.9 6445 Doors � 0 11 DO:Door,wd sc type n 21 0.390 0 13-5 283 11.4 44 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,112" 750 0.032 30.0 1.11 830 1.69 1267 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fIr frish 140 1.358 0 47.0 6578 0 0 2013-Oct-1612:13:05 + vvirightSOft Right-SufteOU riversal 2013 13.0.06 Right J@ Mobile Pagel ...kychp�60501825-fblf-48aO-963c-e39b27lea6O7.rup Calc=MJ8 FrontDoorfaces: E Job: Seeley AED Assessment Date: 10/W2013 Entire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd.,Aflartic Beach,FL 32233 Phone:904-241-1788 Fax:904-242-217-' Effiiiil:Tropicac@msn.com License CAC052430 Project Information 5 For: Craig Seeley,Tropic Heating &Air Conditioning,Inc. 2196 Fairway Villas Ln.N.,Atlantic Beach,FL 32233 Phone� 904-241-1708 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor Heating Cooling Jacksonville/Craig, FL, US Indoor temp erature ('F) 70 75 Elevation: 43 ft Design TD(7) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bul b(*F) 91 Infiltration: Dailyrange(*F) 17 M Wet bulb('F) - 77 Wind speed(mph) 15.0 7.5 for Adequate Exposure Diversity Hourly Glazing Load 10,00(k 9,OOC 8,OOC- 7,OOC- 6,OOC- 5,00C- 4,00 3,00 2,00 1 ,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hmiiy Aerage AMIinit M axi mu m ho u dy g I az i n g I o ad exc eeds average by 19.9%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Od-1612:1305 + vv rigiltSOft Right-Sufte(DU niversal 2013 13.0.06 Right J(D Mobile Pacle I "ZZ51. ...%vetnp�60501825-lblf-48aO-963c-e39b27lea6O7.rup Calc=MJ8 FrortDoorfaces E