Loading...
700 Triton Rd (vault) CITY OF ATLANTIC BEACH s) 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 08-00000321 Date 5/21/08 Property Address . . . . . . 700 TRITON RD Application type description RESIDENTIAL ADDITION/ALTERATION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 6576 --------------------------------------------------------------- Application desc SCREEN ROOM, EXISTING SLAB ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- LOPEZ LIFETIME ENCLOSURES, INC. 700 TRITON ROAD 5521 CHRONICLE COURT ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256 (904) 731-5580 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-A Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE X --------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Permit Fee 70 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/17/08 -------------------------------------------------------------- Special Notes and Comments *2004 FLROIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2004 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. --------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ------- Permit Fee Total 70 . 00 70 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 70 . 00 70 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION Date: Property Address: n � Y l� �r.� Owner•• _��D�Z Telephone#: ay'1 '9a� _V n _,, a e �� Contractor: -A T 1 /L�WA Telphone#: Contractor Address: 105 ��" Fax #: t Contractor Signature: In consideration of permit given for omg the work as described in the above statemen, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Building: Building Type: Ll Ser ce: if other construction is being done on this building ❑ New (,a' Residence ❑ Temp. New Or site,list the building 0' Old ❑ Commercial ❑ Signs ❑ Increase Pe it number: ❑ Re-wire ❑ Addition Sq.Ft. ✓$FiOir ( U � � Conductor Size: AMPS: COPPER ALUMINUM Switch or RACE Breaker AMPS PH W VOLT WAY Existing Service RACE Size AMPS PH W VOLT WAY Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Receptacles CONCEALED OPEN 0 10 AMM 0 AMPS Switches Incandescent Fluorescent & M.V. Fixed 0.100 AMPS OVER BELL Appliances TRANSFER. Air H.P.RATING H.P. RATING CEILING KW-HEAT Conditioning COMP. MOTOR OTHER MOTORS AMPS HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER I H.P. PHS UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon_Transf. J-_ Ea. Sin / 10 /i// Miscellaneous re W 800 Seminole Road • Atlantic Beach,Florida 32233-5445 Phone: (904)247-5800• Fax: (904)247-5845• http://www.ci.atlantic-beach.fl.us Revised 1/04 CITY OF OLVV Office ci Buildi Offi al 0REQUEST FOR I S CTION /� 6 Date " t Permit No. Time A.M. Received P.M. O� Job Address a y Owner's Name . UILDI CONCRETE ELECTRICAL PLUMBING MECHANICAL Footing ❑ Rough Wiring l Rough ❑ Air Cond. & ❑ Re Roofing Slab ❑ Temp Pole ❑ Top Out ❑ Heating Insulation ❑ Lintel ❑ Final ❑ Sewer ❑ Fire Place Pre Fab READY FOR INSPECTION Mon. Tues � Thurs. Friday P A.M. Inspection Made — R anal InspectZcc.pan!,y Inspector Date CITY OF ATLANJAC B A :ice j} 800 SEMINOLE ROAD yr ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 Application Number . . . . . 08-00000321 Date 4/09/08 Property Address . . . . . . 700 TRITON RD Application type description RESIDENTIAL ADDITION/ALTERATION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 6576 ----------------------------------------------------- Application desc SCREEN ROOM, EXISTING SLAB ----------------------------------------------------- Owner Contractor ------------------------ ------------------------ LOPEZ LIFETIME ENCLOSURES, INC. 700 TRITON ROAD 5521 CHRONICLE COURT ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256 (904) 731-5580 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-A Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE X ------------------------------------------------------- Permit BUILDING PERMIT Additional desc . . Permit Fee 65 . 00 Plan Check Fee 32 . 50 Issue Date . . . . Valuation . . . . 6576 Expiration Date . . 10/06/08 -------------------------------------------------------- Special Notes and Comments *2004 FLROIDA BUILDING CODE W/ 105- 106 SUPPLEMENTS . 2004 FLORIDA BUILDING CODE - RESIDENTIAL. 2005 NATIONAL ELECTRICAL CODE. ---------------------------- Other Fees . . CITY RADON SURCHARGE . 05 ST CONSTRUCTION SURCHARGE . 90 AB CONSTRUCTION SURCHARGE . 10 STATE RADON SURCHARGE . 95 ---------------------------------------------------- Fee summary Charged - Paid Credited Due ----------------- ---------- ---------- ------- Permit Fee Total 65 . 00 65 . 00 . 00 . 00 Plan Check Total 32 . 50 32 . 50 . 00 . 00 Other Fee Total 2 . 00 2 . 00 . 00 . 00 Grand Total 99 . 50 99 . 50 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. j�- 7 NOTICE OF CONEMENCENIENT ' STATE OF COUNTY OF THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property: (legal description of property, and street ad if available) ?. General description of improvement: ZOO(Y) 3. Owner information: a. Name and address: L010 C Zr • Q d --F(, 4010 /zip &Iq4 r 6e.a.ek J,4aU.3 b. Interest in property: c. Name and address of fee simple titleholder(if other than owner): 4. Contractor:(name and address.) JAP l ele a. Phone number. al,)/ 5. Surety: a. Name and address: b. Phone number: c. Amount of bond S 6. Lender. (name and address): a.Phone number. 7. Persons with the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7,Florida Statutes: (name and address): 8. In addition to himself, Owner designates the following person(s)to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes:(name and address) 9. Expiration date of notice of commencement (the expiration date is one (1) year from the date of recording unless a different date is specified) This Space for Clerk's Use Only AMY U00uleVIN '(signVure of ow er)Y `� E cp"W200 Banded um,csocy;s2 Szs, Sworn to and subscribed b fore . 'a° Doc#2008079414,OR BK 14439 Page 1292, this y of G�Q Number Pages:1 Filed&Recorded 03/28/2008 at 02:09 PM, JIM FULLER CLERK CIRCUIT COURT DUVAL COUNTY NO Y PUBLIC RECORDING$10.00 + ECC E 7F ATLF" �ynlr CITY OF ATLANTIC BEACH _ 800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 O OFFICE (904)247-5826 0 FAX NO.(904)247-5845 BUILDING-DEPT@COAG.US - BUILDING PERMIT APPLICATION DUVAL COUNTY 1,JOB ADDRESS: 2,VALUATION OF WORK: 3,SO.FT.UNDER ROOF b b n o&A to?bb 4.LEGAL DESCRIPTIONS 5.CLASS Or WORK: 6.U5WOF STRUCTURE. ❑/�yW BUILDING 11 DEMOLITION RESIDENTIAL LOT_BLOCK SUB DIVISION Q ADDITION ❑CONVERTING USE ❑COMMERCIAL 7.DESCRIPTION OF WORK: ❑ALTERATION ❑ACCESSORY BLDG. 8.FIRE SPRINKLE Q ^ ! [I REPAIR ❑POOL/SPA ❑YES N/A El MOVE ❑OTHER ❑NO PROPERTY OWNER: CONTRACTOR: ARCHITECT/ENGINEER: 9.NAME, ( (� 16.COMPANY NAME T C ,^ Efe e� 23.COMPANY NAME 16.NAME. L�FE LIFETIME ENCLOSUprg' 24.LICENSEE NAME. 1r.r.r.owl nM 13RIAR 10.ADDRESS. /� /r/J[/��y� 17.STATE O C f&Q WJE NO.: S0�♦^,�s 530 25.STATE OF FLORIDA LICENSE NO.. 766 r,'�! / Y ► 18 ADDRESS ( 4NTtlWv 26 ADDRESS 5521 CHRONICLE COURT 67ea'C JACKSONVILLE,FL 32256 11. F C PHO Q 12,FAX O.:/ 19.OFFICE PHONE: 20,FAX NO.: 27,OFFICE PHONE: 28,FAX NO. 7LFS 7'A 11 15580 13.CELL PHONE. 21.CELL PHONE: 29.CELL PHONE: 14.EMAIL ADDRESS: 22.EMAIL ADDRESS: 30.EMAIL ADDRESS: FEE SIMPLE TITLE HOLDER: BONDING COMPANY: MORTGAGE LENDER: IIF OTHER THAN OWNERI 31.NAME: 33.NAME. 35.NAME. 32,ADDRESS. 34.ADDRESS: 36,ADDRESS. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six (6) months, or if construction or work is suspended or abandoned for a period of six (6) months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks, Air Conditioners,etc. OWNER'S AFFIDAVIT- I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I will not occupy or use the referenced building or any part therof, until all inspections are finaled and prior to obtaining a certificate of occupancy or completion issued by the building official,as required by law. *** WARNING TO OWNER: *** YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER or AGENT CONTRACTOR f Agent,Pa/el Pa/eof Attorney or Agency Letter Required) (Qualifier Only) Signed: Date. L� Signed: i D te: P.a�• Before me this day ofAf 2007 in the county of Before m thi day of . 2007 in the county of Duval.State of Florida,h s personally appeared Duval,St orida,ha ersonally appeared -. - Tes.x.y��►oawB17?o09f�?t'�M..n'f"10�'� •.erwtS tw•••t.•ttat.lttt•)t.!••�N.� �P?�.� awry GCO�wrlw - OODWiN _ herin by himself/herself and a Irms�1a➢>q{t� ents t WgJ"%W 'e : henn by himself/herself and affirms that a�st 1 and d8gAf9A Z� l� : i rst 6!5!2069 true and accurate. ii tN�.eZtau.b,,I'1.' rate. ' 4254 '. g., ..� r•, 2 256. �j , yl thi �21.�ducedldenl'lfi arge State f aF` ounty of •��� nc ' at Large,Stat l monally Knon nown 5' ion- ► El Produced Identificatio Notary Signature: Notary Signature: REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH M"Mr6..w Y�tRT)W'R,Yb•rM47aWJ♦w�` &REdwaAdaspeoR)Ali eriONAL } REQUIRE 'ONDITIONS o� r FILE COPY = REVIEWED BY. MATE: P HOMEOWNER SUNROOM ENCLOSURE AFFIDAVIT The purpose of this document is to make you aware of any limitations in the enclosure that is being permitted at your residence. The table below, Sunroom and Screen Enclosure Requirements provides a brief description of the various sunroom category requirements. There may be restrictions on the use of ycur present home depending on the category of sunroom you are installing. The property owner is hereby notified that should any form of temperature control system be added to a Category I, II, or III Sunroom or the removal of the doors separating any Category I thru IV Sunroom from the host structure occur, the room shall become non-compliant and must comply fully with all of the requirements for habitable/conditioned spaces as mandated by the Florida Building Code, The Florida Model Energy Code and State Statutes. OWNER I have read this complete f&and understand I am receiving a Category- Sunroom Printed NameAddress Q, v f �� Signed: Before me this day of in the County of Duval,State of Florida,has personally appeared herein by himself/herself and affu-ms all statements and declarations herein are true and accurate- ter.+ omaitlOCJ4a'22" Notary Public at Large,State of_ County of ' '>' �3 olros 5,5r20c8 Personally Known or Produced Identification❑ C T"'r 3 &.dad avu tsoci4 ID Type µaa t r; •nc i Sunroom and Screen Enclosure Requirements Category I II III IV V Habitable o No No Yes Yes Space Foundation Walls <200plf can Walls<200plf can Walls<200pif can Walls<200plf can Walls <200pif can have 8"Wx12"D have 8"Wx12"D have 8"Wx12"D have 8"Wx12"D have 8"Wx12"D ftg or 3-1/2" slab ftg or 3-1/2" slab ftg or 3-1/2" slab ftg ftg if no concentrated if no concentrated if no concentrated load >7501b load >7501b load>7501b Exit Lighting Not Required Required Required Required Required Interior Electric Not Required Not Required Not Required Required Required Outlets Emergency Egress from exist. Egress and Exit Egress and Exit Egress and Exit Egress and Exit Escape structure allowed must meet code must meet code. must meet code. must meet code. Openings if open to Other resistance Other resistance Other resistance atmosphere or requirements for requirements for requirements for considered forced entry, air forced entry, air forced entry, air screen enclosure leakage and leakage and leakage and and has screen water penetration water penetration water penetration door leading also apply. also apply. also apply. away from residence. Misc.Window Host structure Removable Removable Host structure Host structure and Door windows/doors windows allowed windows allowed windows &doors windows& doors Requirements shall not be in sunroom. Host in sunroom. Host shall not be may be removed. removed. structure structure removed. windows/doors windows/doors shall not be shall not be removed. removed. Wind Borne Debris Opening Not Required Not Required Not Required Required Required Protection Energy Sheets Not Required Not Required Not Required Required Required 0 fn 7r (0D-4r- 00 J, m�5W 1.' 0) O n 73 0 00 aCfm am�_�aa fD N xk =-IN 031°? xo3� 0CDa moo- W =d I �O N Maya CL-camCA� O0 A N 3 x n_O fA ni v C@ to CL XXCL 0 o o m.. co(DC-tTLr- �� ON x O (D ��°'a ow �ra oowcncc No0 -' � f."1;; �m0°Ma ' — W 440 j�N N l r• N Cosa m3 'a�� 0 EL 1 x2x(M4 CA)Wj �0j m 0) 0 N m m g m e(A» m: N m ' ' < '' � m n W ycCL m°, CL-4 n x5x062 -4((31=� n �' 'o n 0 3 rnmtD �� °10 '_ OO-n 00 (j)(A3n nlw o a � � m w (D 00I @ . a a O .Z1 NC ACA 7 N ' CA��- A m x5x062 rn a J t i 1 X2xO44 I � I r- -----------i L-_ 2x2x044 1 ---J xF-- ------------------ N x -- -------------------- Oi-- ---------------------� `eG} r-- ---------------------- x5xO62 -- ---------------------= w 1 x1+ -- ----------------�sr---� m � I -- \ N -- ----------------0 ---J O I_ I I XX062 O r-- ---------------------� ' w t i__ _ _ Q A N i --------------------- + ----------- --------J I'-- ----------- - � O O I I \ m I ^ IL-_ � ' I I I A L-- ----------------------'I CO I � I I r-- I 2x2xO44 L-- I 1 I 7'-3"+/- -- ---------------------I 10'-0"+/- tx2xO44 A I' O t c x5x062 1 0 t A � I- tD t lx2xO44 x x :wan aamb —.uDd aJ► 8 P atl �� S P s21Q 44 :4+P!^^/PDol ti'D4-nq!J1 'U!— 4.y6!aH JapDaH Mopu!* x z X=uo!sna4x3 paJmbaa :uDdS paJ!Sao :4-�P!m/PDc� AjmD nq!a1 u! .�y6!aH i!Da Jiayo/a+Dld NorN (ParD!Du3/nDl9 0-�Pal.IanuoD swoon ua2ja3)xx)T'E'8£3!gI4 TE-8E rw4.�09-8E 26Dd(a.rn4anJ4S PasoiDu3/swoon—16)xx)-T'Z'8E 214D1 6t-8E Tu44.St-8E 260d'(swoon!Aum Jo UaaJas)xx)TZ'VE 219D192-VE nJ4-�t2-VE abod :SJapDaH MOpUT I IDa JIDI.L-) I IDJ a I.DI OI� x Z :wDa aamba 8 P a-44 � :uvds PaJ!saQ '44 -t, :4-�P!m/pw j/,JD4nq!J1 >C—:tuDaB paambaa 4 .uodr paJlsaQ •}� S :4P!M/pDoI I.JD4nq!a1 (P-01l U3/rrD19 04-Pa.�JanuoD rru00b uaaJ3y)xx)T'E'8£a19D1 I9-8E rL4.�09-8E 96Dd (aJ=m 4S P-013u3/swoob—16)xx)-TZ'8E a19D-�6t-8£-4+at--8E a6Dd'(swoon IAu!A JD u32JD3)xx)T'Z-VE a!qa�52-VE nJ44 t,2-VE a6Dd :•4HI J n/4-sDd 73- x—, 3-x ` :waa8 paJ!nbaa 44 S 1 'r :uDdS pails -44 :y4-plM/pDcl A.+DgIJ1 (W-Zj Pas01u3—je 0-.pa.JanuoD uloob uaaJaS)xx)E78E 219D4 Tt•-SE PUD 8E-8F 26Dd (2Jn4Drw4-3 P`01343/sw00b v=16)xx)-T-T'8E 219D4.EE-8E TIJ41 OE-8E a6Dd'(rwoon IAuV,Jo ua2w33)xx)-T-T-VE 314D4 ZT-VE Tu4+01-VE 36Dd :WDa x x :11!aa8 paJmbaa 44 :uDdS paa!sao '}} :y.-p!M/pao-I LJD4-nq!J1 (—n4.on.45 Par MS/sluoon—16)xx)-9-T'8E 211/ .Lt-EE ry4-�9t-SE 26Dd'(swoon IAu.A Jo uaaJaS)xx)-b'T-VE 219D1 EZ-VE Tu44.ZZ-V£a6Dd ON S2/, ❑ :WDaB aOpl-d Xx :wDaB paambad 4 :undS paa!saa .�4 :4-EP!m/PDCj /,JD4-nq!.j1 /,JDpuooaS x x :waa8 paambaa 44 :uDdS paJ!saa :y.�p!m/pDoj /,JD4.nq!J1 /,JDw!ad (a.Intan.45 P-012u3/swo0b—16)—)-t•'T'8E 219Day-i-8E ruH4 2t^8E a6DDdd) '(swoon IAu!A Jo uaaJaS sno2Lwjj2x!W)xx)-E•T-VE 219D1 02-VE Tu4�ST-VE 36Dd ON Sa/1 :wDa SnoaUD BDSI JO D Jno ❑ ❑ 8 I I -W IIDM 4� wno.� ql Z ql Z/I-I T T ss-aUP!4-, /M IauDd a.!_!Sodwo.-). ❑ �A011D 52-H/901F /q ssaui{o!y,!_. aP!m-z' /,q IauDd Jasw ❑ :6u!sn 09-L s726Dd ruI{4.2t,-L s260d PLm SE-1 Tu44 ZE-L sa6Dd'O£-L a6Dd ;UOI4.:)al a3 IaUDd -- 02i :�(q smopu!m�I9 -44 S Z L. :I IDM 5U!JDao pD01 SMODUIM SSD16/ DOJ PI105 � /SIIDM Uaa?S 7-1 2q, p-puD'ty aj.- ,nafS 4.SO D 6,' sMOpU!M I�(U!n/�00J P!Ios/SIIDM uaaaos uI aJ on ti �+ }y ❑ 4 .14 S.-soy uo 6uDyJan0 �OOJ p!IDS/SIIDM UaaaoS © 44 AIuo sIIDm uaaaos ❑ :lo wow D Joh 44 :u043ar0Jd :az!S wood{ Ilwa^D 0 I ❑ LL' 0 :Jo+oD-j ZDUD.JDdWl 8 ❑ d ❑ :/,JD634.D.-)zinsodx3 8T' ❑ 95' ❑ O [71 :4-ua!D!4.3.9o.-)aJnssaJd 1Dua3+ul PasolDu3 FAI pasolou-D /1IID4JDd ❑ uad0 ❑ uaaJDs ❑ /,Jo64vo 6u!pl!n8 Jay+O dr)-IA IA -i d-/1I :adA_L U014-)n4suo-) :adll/.DUDdnD:)D (4uno3 su4or '.�S u! 96-140 4,-D3 PuD V6 fO 4+noS TSn 4o-�sD3 'V6 40+sD=- '4unoD C. nDssDN 04 4+JoN LI Sn 4o 4-sD3 '•pDob �4n16 molls/,�o.(SDa)auoz swgap auaoq pu!/K ❑ ydW �1 :paadS pu,M 0£961,003 JDIJB .d S3=1/ILtSZ O tID JDIJB •V kla,4ar (a2u6,sap ur)q�aay4.o�!)Jo4.:)Dj4.uo.? :Jaumo 0916-T£L-t,06 0299-I£L-tr06 :1211 96ZZF 1d'aII!nuos�oD.0 -4-inc.?al:,,uoayD IZcc -OOZ/ 52-1 2 :a MDQ 'ouI'S3bn30-I--)N3 3wzi3-�n 40 JDIJ8 -d sawDr :JaU61s204 1DnuDW u0.4D!JDssd wrxr!u,n!d 'COOL 'I yDJDW y-!M *,002 3QOD 9NIQ-1ins vQno-jd '86-1 37Sb --3"d '442uua8 -3 2Du2JMD-1 Aq uD4!P3 i'OOZ 'IDrwDW u5!saQ aJn4xu1s wnumn!y 2au2-mp-d D sr 5u!sn I/IuiA uo 'SSDI9 'u33JDS-400oj PHOS/M woos 014-Dd VWZ - NOLI.?3'139 1N3NOdWO.) / N9IS3Q - VOOZ ATTACHMEN15CHEOULE ae per 2003 Aluminum 5tructuree Design Manual by L.E. Bennett, P.E. ATTACHMENT FASTENER NUMBER PLACEMENT Hoot Structure(wood)to New wall #105<2-1/2"5M5 1 24"o.c. Host Structure(masonry)to New wall '/4"x2-1/4"Concrete Screw, 1 24"o.c. Walls to slab '/*"x2-1/4"Concrete Screw 1 within 6"of Post variee And 24"o.c. along the length Walle to wood deck #1Ox 2-112"!5M5 1 within 6"of Poet varier and 24"o.c. along the length Header to Faocia #10x1-1/2"5M5 2 Per Rafter or Truro Tail #10x3/4"5M5 1 12"d.c. Header to Maeonry Wall '/4"x2-1/4"Tapcon Anchor 1 24 o.c. Header to Wood Wall #10x1-1/2"5M5 1 12"o.c Pan Roof to Header #8x1/2"5M5 1 at each riser #8x1"5M5 3 through the boxed pan Composite Panel to Header #8x1/2"5M5 1 8"o.c.upper ride #8x1/2"5M5 1 6"o.c. lower ride Pan Roof to Beam #8x1/2"5M5 3 Equally spaced acrooe the 12in. span Composite Panel to Beam #1Ox(t+112-)5M5 1 12in.o.c. w/1-1/47'fender waeher Pan Roof along non-load bearing element #8x1/2"5M5 1 24'o.c. Compoeite Panel along non-load bearing element #10x(t+1/2' 5M5 1 24"o.c. w/1-1/4"fender washer Non-load bearing wall attachment to load bearing wall #10x1-1/2"5M5 1 6"from either end of poet #10x1-1/2"5M5 varier, 24"o.c. Beam to wall connection (concrete or #1/4"x2-1/4"Concrete maeonry wall) Anchors 2 Per ride Add 1 anchor per ride for each additional inch of beam greater than 3 inchee. Beam to wall connection(wood) 3/8"x2"Lag 5crews 2 Per ride Add 1 anchor per ride for each additional inch of beam greater than 3 inches. Beam to Aluminum wall connection #10x1-1/2"5M5 2 Per ride Add 1 anchor per For each additional inch of beam greater than 3 inchee Page of w ¢ a Cl) Ui in cr m w a� m 01:zLU us LLJ X F0 x�.( H ~ U O N N F Z�� r U Q } z y x F W ,W c` ¢ U)�rA m ¢ �� �O O Z (n U X(n �(n w0-igcn U OxU It W .-m 0 J ¢�m O F- W ¢ (n LLLU U X = ^ #p w O � LLJ �j ID C,4 v 111 d } LU O W ? Q ¢ > - vw' d OX z V N Z: U t= ax x Z a_LU x ...W N� ¢ = m R �x Z J (nW �-U N Q Wa W � U NpJ (ZnUm � - NOQ C� mx Z0 X m z m= � �m XJ x ¢Zx N � Xxr- O x ¢ roof �? Q x = Nx �¢�oi � � azo W J_ r ¢ a QQ m co {j C7-m IL. O J a' ' J a . O � c Q O Lf ` J _ zx0m O (n Oryz_ xx in 2 xw [r J� w=zw NJ g�j(n O zO z0 ~�xU ¢ aim wW w = WfnLLf-p0 JO X � O� ai ~ m m Lu O � W Zx Z J(n NJfn J N m W N � � N� a~a X� LLU in jU -� O-OWp¢ = wo M)0 Z x � W .tW a� (n00 No W xz Q LLm2xU HJ m.04m z. x x xW. m m w0 000)00 �� -5 -1 O '-� 0 JviO cnU N�Opv g XLL �U 0 < x aO �•=w W a ^ m C4 X�V y0 (ncr (t x AWN N Y SOU _ _ W _ ¢ W x~ ¢ Uzx LU ¢ N,Op m xw¢Z O y x (n W po X OxWLU (gym O O �z�F N p ¢c�Z C.) Z 0 ¢a. g q U.v 0 X ¢ ¢z ¢ ¢O Z 6 m O > O V� LL N C/)� O U O 03 U a O cn LL z > Z% U =LLI LU Z LU 0 P O 0 , U U 0 W ¢D Zgw w xit z 00 xz5M2 mom= 0 6Z p�N FUcn w0:'W LLUx J p - x¢ p w —¢ . O LL H� (nJ Z 0 zU) (n0 —@�N7 Q� x JQWP JQ LU aW W ZW X 0 EL z r-r-(n o � z a = ¢ � o � 3: � p -W t¢- ¢ �ir0 ¢(dna W# W QY(n N X(n 7_ (nUUSF-.JU J.-.= O�U� p Xom O -� ZzU (n-Jz m tL � Ua� O¢ � ¢ (n UaU Q H W D W z O U W Q ® z , m W J . Z a J Q U 6 i 3 xEn LU u)ci a in U(n¢ a. c7 =t- 00 Wk 0 2 LL N J ¢ O 2 LL N ` 0 ��-�O ❑ LL ¢ � vi0O W yQZQ YZ�Z< rn w p mLLN= O ¢ =NS U 0 x m U w�'� LL z�— EL X w 0 ' O O 0 0 x st x X Pan roars reqStanding Seam Riser pans/Composite panels uires 3 #3 x 1!2" sms Depth, metal thickness, alloy, foam wt. M be placed evenly across the can determined by clear scan of the roof, numoe.r-or into the [cad bear ng wall and I,' - equally spaced anther pelts using age -r° x T/2" s-�s 24" g �• q Y g p 7-34, o_c. alon ane ncn- pages 7-32 thru 7-38 and pages 7-42 thru 7_5Q_ load 'Dearing wall. Composite pane! attachrrrent requires 1 i 0(t=1/2")SMS w/1-1/4"fender washer placed every 12 " o.c_ along the load bearing wall and 24" o.c. along the non-lead bearing walls. I ` Edge beam span and size determined by 112 span+ overhang or 112 span whichever is greater using pages: 3A-10 thru 3A-12 table 3A_1.1-mph I I 38-30 thru.36-33 table 313.1.1-mph 313-38 thru•38-.1 table 38.1.3-mph j ; I Girt andlor Window header girt size and I maximum span is determined using pages: 3A-24 thru 3A-25 table 3A.2.1-mph I I 38-48 thru 36-449 table 38.2.1-mph � I 38-50 thru 3B-51 table 38-3.1-mph I � Upright (pcst) size is determined by height requirements and distance between the uprigr is as shown on pages: I 3A-24 thru 3A-25 table 3A_2.?--nph 36-48 thru 313--49 tabie 36.2.1-mph• r 36-50 tf'7 u 3B-51 table 313.3.1-mph 1 II � I I I I K ICkCiate rail or Ctiairrail girt size and, maximum span is determined using pages: I • 3A-24. thru 3A-ZS table 3A.2.1-mph 38-48 thru 313-49 table 38.2.1-mph 313-50 thru 3E-51 table 313.3.1-mph J 1/4"x Z-1/4" Ccncete screw mithin bin. or each past and 2a�� alcn the perimeter of the encicsure Sofepiats �Aro'ves;' FaUndatiart LSlab andlor'acting as required by Slab-=oating Details j on page 3-24 and niotes 1 thru e. zcal cnde is anal authority• TYPICAL SCLIC RCCF SEARING WALL SECT1CN D D D - lll` LU H ^ W U r n � �i= L O C H _I \•� ►W �-5 < ON1 v -dip �I ° u_ � cSu LU 1 C 3U ri �n nZ D< LLL LL, W L✓7 e> =11, J> J �O V U � LQIe�"•�W `= N_ C =D ^W =„>W„ D � 1 07 __ W t a W LLD t d C Kl L 2: i< D C t < = ?5 L C eLDJ '� `p �I� D Nc -eve+– � C ` t W I �` O Dau>✓ O V `.'�L GmD°�=nw DD.• CYcO CSSuj LU V I Q nON DyC�!<� VD�O 1LI O w = 03 Dp _ u`� O �e •� n U' w C h DD>0 ►^5 W C > to r:C W i. W K M – F.OVC DC _W LLI o U _ LL 0 3 `c! D^ a rn } C >Cca W–r, uj e 10 D ul a� �D O Nyp CSG W j D CO LuOnWU�u•c D DL+<U U 3 in.romoasr ,an c`Svsterr -------------- ' Scam is: x Z x i 1 0 lSS in.av=hfing; Fanoin. 5idc wall po5 is: _ Z Ii 2 a ' x � lead ocarina Dos ie ` (� � 1—/ 1 Doo- lac.-m^rrand. pos plat-mer varic_KL ; v J o '�n. Kn.�vrdll •• tS� F— Ghai^-zil J ------------- ----- - i--- -- •......... _ L1 r –__ 7120 V.1�„1•,'_y f 7c=s�.^-�reurz_s��.e�ie^s.sn:L-ne.e! — .� Maeonnan�brick knccwall5 rcauir�Oc..cr5 – --__–_ ,'� • , • ---------------------- -- -k, - - -.- - - -•--- -- 1 L� c tiV -,AL SECTION 7 SOLID ROOF PANEL PRODUCTS PAN ROOF ANCHORING DETAILS PRIMARY CONNECTION: (3)#__-SCREWS PER PAN SEALANT WITH 1"MINIMUM EMBEDMENT INTO FASCIA THROUGH PAN HEADER(SEE NOTE BELOW) BOXED END I, EXISTING TRUSS OR RAFTER = ROOF PANEL w � #10 x 1-1/2" S.M.S. (2)PER Q w #_'x 1/2"S.M.S. (3)PER PAN RAFTER OR TRUSS TAIL a (BOTTOM)AND (1)@ RISER — — (TOP)CAULK ALL EXPOSED #10 x 3/4"S.M.S. @ 12"O.C. SCREW HEADS EXISTING FASCIA 1-1/2" x 1/8"x 11-1/2"PLATE OF 6063 T-5, 3003 H-14 OR 5052 H-32 ROOF PANEL TO FASCIA DETAIL SCALE: 3"= 1'-0" SEALANT FOR MASONRY USE j HEADER(SEE NOTE BELOW) 1/4"x 1-1/4" MASONRY ANCHOR OR EQUAL @ 24" O.C. FOR WOOD USE#10 x 1-1/2" — S.M.S.OR WOOD SCREWS @ Ii f=- 12" O.C. ¢ w 1� a ROOF PANEL EXISTING HOST STRUCTURE: — — WOOD FRAME, MASONRY OR #_*x 1/2"S.M.S. (3)PER PAN OTHER CONSTRUCTION (BOTTOM)AND (1)@ RISER (TOP)CAULK ALL EXPOSED SCREW HEADS ROOF PANEL TO WALL DETAIL SCALE: 3"=V-0" ROOF PANELS SHALL BE ATTACHED TO THE HEADER WITH (3) EACH#_*x 1/2"LONG CORROSION RESISTANT SHEET METAL SCREWS WITH 1/2"WASHERS. ALL SCREW HEADS SHALL BE CAULKED OR SHALL HAVE NEOPRENE GASKET BETWEEN THE WASHER AND THE PAN. PAN RIBS SHALL RECEIVE(1) EACH# *x 1/2"SCREW EACH.THE PANS MAY BE ANCHORED THROUGH BOXED PAN WITH (3)EACH #_*x 1"OF THE ABOVE SCREW TYPES AND THE ABOVE SPECIFIED RIZER SCREW. #_*x 9/16"TEK SCREWS ARE ALLOWED ASA SUBSTITUTE FOR# *x 1/2"S.M.S. *SELECT THE APPROPRIATE SCREW SIZE PER WIND ZONE FROM TABLE BELOW. JIOO-1231 130 1 140 1 150 #8 #10 #12 1 #12 REVISED APRIL 2007 Lawrence E. Bennett, P.E. FL # 16644 CIVIL&STRUCTURAL ENGINEERING P.O.Box 214368,South Daytona,Fl 32121 Telephone#: (386)76714-r74 Fax#: (386)767.6556 Emad: I ebpeCdbeNsouth.net PAGE © COPYRIGHT 2006 7-2 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E.BENNETf,P.E. General Notes and Specifications for Section 3A Tables (cont.): Conversion Table 3A-C Load Conversion Factors Based on Mean Roof Height from Exposure "B"to "C" &"D" Exposure"B"to"C" Exposure"B"to"D" Mean Roof Load Span Multiplier Load Span Multiplier Height' Conversion Conversion Factor Bending I Deflection Factor Bending Deflection 0-15, 1.21 0.91 0.94 1.47 0.83 0.88 15'-20' 1.29 0.88 0.92 1.54 0.81 0.87 20'-25' 1.34 0.86 0.91 1.60 0.79 0.86 25'-30' 1.40 1 0.85 0.89 1.66 0.78 0.85 30--40' 1.37 1 0.85 0.90 1.61 0.79 0.85 Use larger mean roof height of host structure or enclosure Values are from ASCE-02 3A-ii SOLID ROOF PANEL PRODUCTS SECTION 7 V� 47(n ml-_C)m g 47 47 47 Cn 0) C) C > �V LO CO (D nm 00 C > �Ctn coW r--co m r carom �iIO f?c? - m=a�0000inIT 1919 q O> U cerin c7 c7 i�i+)i� O> U cvcci�7 �NMM V Cin inn(D 'a C14 CN7 C' M W) COD N O O 'OS E ��C?47 Zn ;;q V th (M CN CN N 00 y�<'7(VN�'- rm O t0II IIN Cl) 7 V In to AII IIN C11 Cl)V'C In to (o (Q O a 0) A D 7 y O 7 y IO > LA O V m G� ACV Oa?m C) O U Z.;z <D U W N C eN .-O C ASN Nr Z = W y r rm(n(n W y r y r r r y r r r r r r m a t` IIN M -Ir tT tOn LO IINCh V Ctn to LOn) (ma C t N t0 N 4 N O O C mac? a c)^Q`�in M� n oc�ioiDC�4 m O M y0 Q)GO N aO�rN y^m mm�0000 20 r (II4 N IIn NrOm- �tim rm CIO Co N O �y r N NC-4 C�)('7 C')V y r r N N('7 Cl)(7 C a LU Q c E �'c:-a�a)vctmi� `*=i? go$oo .Q N cL a 3 y in MNN Ni- y t0<IO in<2 C7 N N N M r r r r r Li a -Q lu £ > E > c QW E 0 0 �r Nr03 CION 0 0 :atemI�m�""'cc CD N 0) r � IO u M N N N N ( f7 M V 0 u M N N(7(`')PI Q N _ it-a O LK C m J d 11 a = =M ^�rmcD�iD 'Dr CL(y'c�aO NiIO;-in inO � � om 10 0 i�)^N&A r^O 9 CL in in c7�)P7 CV CV y r 2 Q� [] r yrr r r r r c1 r 0 y v, a u�a c �/� a V o6 04 l�m r r Co (4 v� O MN NN C7-Cn QC cN N C-4 C-4 L N G O �a T r �Nr(?mcr� n MQ �rr�mmZ�t a [V O In to mm In rOrQ)d) tQi C a 'II r2 Rl� MI� n.N 'IIO CN rN 3 O r r N N N N(') r N N N P) X Lq ca� o �_ - _ _ - orrr- - - - - 3 tea v, � N QtJ7 `' Iq y(D (Din�ih�NN m yt`"rmtain�in('t II `c T' V7 � L a c rrrrr rra o rrrrr rr .3 VARIES y 3 a`t04 - _ M 313 � a^TOU O ix o II 3 � �rn °t' ein ��5�cco &)oain5i �i�in:-�C709C? O C C (/i 10 tD fNf c•7 fV CV(V C t� r(D 47 zn(n II L' 47 d O yr r r47 d O yr rrr r awl rL r rrr ` CL r r 3 d o o _ N 'i =0(0 �O f")h t�(O Na a(D�O M hh cV C M 114,N N N N M. N N N N N('') (Q N O4=1C-4 M O ^C?�c7:-0)t?c7 ;Q� rte., Ci!)Z N �rtD O �j C7 c9(V fV��COC �O mc') i'7 CV X y r X y r C ti O �N X p a 0O N N(.O'f OR )O X C O a 0 N N 10,7 R h d i�f �N gr ��� ,,,rte 3N gyre--e���� Z WETRLS USR Lawrence E. Bennett, P.E. FL# 16644 Bui 1 di ng ProductS L.P. CIVIL&STRUCTURAL ENGINEERING 7815 American Way, Grovel and, FL 34736 P.O.Box 214368.south Daytona.FI 32121 TEL: (352) 787-7766 X202 FAX: (352) 429-2011 Pelepnone#: (386)767-4774 Fax X: (386)767-6556 TOLL FREE: 1-800-342-9077 bkaufmannLametalsusa.com Email: lebpe@beusouth.net" PAGE Cc) COPYRIGHT 2006 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E.BENNETT,P.E. 7_39 SECTION 3AT . SCREEN, ACRYLIC & VINYL RQOMS Table 3A.1.1-120 Allowable Edge Beam Spans-Hollow Extrusions for Screen, Acrylic or Vinyl Rooms For 3 second wind gust at 120 MPF!velocity; using design load of 13.0#/SF(48.3#/SF for Max.Cantilever) Aluminum Alloy 6063 T-6 2"x 2"x 0.044" 2"x 2"x 0.055" Load Max.Span'L'/(bending'b'or deflection'd') Load Max.Span'L't(bending'b'or deflection'd') Width(ft.) 1 a 2 Span 3 Span 4 Span Max. Width(ft.) 1 8,2 Span 3 Span 4 Span Max. Cantilever Cantilever 5 5'-1" d 6'-3" d 6-4" d T-11" d 5 5'-4" d 1 6-7" d 6'-9" d 1'-0" d 6 4'-9" d T-10" d T-11" b T-11" d 6 T-T d 6'-3" d 6'-4" d 0'-11" d 7 4'-0" d T-7" d 5-6" b T-10" d 7 4'-9" d T-11" d T-11" b T-11" d 8 4'-4" d 5'-4" b T-1" b T-10" d 8 4'-7" d 5'-8" d T-7" b T-10" d 9 4'-2" d T-0" b 4'-10" b T-10" d 9 4'-5" d 5'-5" d 5'-3" b T-10" d 10 4'-0" d 4'-9" b 4'-7" b 0'-9" d 10 4'-3" d 5'-2" b T-O" b 0'-10" d 11 3'-11" d 4'-6" b 4'-4" b 0'-9" d 11 4'-1" d 4'-11" b 4'-9" b 0'-9" d 12 T-9" d 4'-4' b 4'-2" b 0'-9" d 12 3'-11" d 4'-9" b 4'-7' b 0'-9" d 3"x 2"x 0.045" 3"x 2"x 0.070" Load Max.Span 'L'/(bending'b'or deflection'd') Load Max.Span'L'/(bending'b'or deflection'd') Width(ft.) 1 S 2 Span 3 Span 4 Span Max. Width(ft.) 1 8,2 Span 3 S an. 4 Span Max. Cantilever Cantev er 5 S-8" d T-1" d 7-2" d 1'-1" d 5 T-F d T-11" d 8'-1" d 1'-3" d 6 5'-4" d 6'-8" d "a'-9" d 1'-0" d 6 T-O" d T-5" d 7'-7" d 1'-2" d 7 S-1" d 6'-4" d T-4" b 0'-11" d 7 T-9" d T-1" d T-3" d 1'-1" d 8 4'-11" d T-0" d T-11" b T-11" d 8 5'-6" d 6'-9" d 6'-11" d 1'-1" d 9 4'-8" d T-9" b -7" b 0'-11" d 9 5'-3" d T-6" d T-6" b 1'-0" d 10 4' d 5'-6" b 5'-3" b T-10" d 10 5'-1" d 6'-3" d 6'-2" b 0'-11" d 11 4'-5" d 5'-2" b -0" b T-10" d 11 4'-11" d 6'-1" d T-11" b T-11" d 12 1 4'-3" d 4'-11" b 4'-10" b 0'-10" d 12 4'-9" d T-10" b 5'-8" b 0'-11" d 2"x 3"x 0.045" 2"x 4"x 0.050" Load Max.Span'L'I(bending'b'or deflection'd') Load Max.Span'L'/(bending'b'or deflection'd') Width(ft.) 1 &2 Span 3 Span 4 Span Max. Width(ft.) 1 8,2 Span 3 Span 4 Span Max. Cantilever Cantilever 5 T-1" d 8'-9" d T-9" 010- 5 9'-2" d 11'-4" d 11'-2" b 1'-9" d 6 6'-8" d. 8'-3" d T-11" 6 8'-8" d 10'-7 b 10'-3" b 1'-8" d 7 6'-4" d 7'-8" b 7-5" 7 8'-2" d T-9" b 9'-5" b 1'-7" d 8 6'-1" d T-2" b 6'-11" 8 T-10" d 9'-2" b T-10" b 1'-6" d 9 5-10" d 6'-9" b To 8" 9 T-6" d 8'-8" b 8'-4" b 1'-5" d 10 T-T' d T-5" b 6'-2" 10 T-T' d 8'-2" b T-11" b 1'-5" d 11 5-5" d 6'-1" b 5'-11" 11 "a'-11" b T-10" b 7'-7" b 1'-4" d 12 T-3" b T-10" b -8" b 1'-0" d 12 6'-8" b T-o" b 7'-3" b 1'-4" d Notes: 1. Above spans do not include length of knee brace. Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 2. Spans may be interpolated. Lawrence E. Bennett, P.E. FL# 16644 CIVIL&STRUCTURAL ENGINEERING P.O.Box 214368,South Daytona.FI 32121 Telephone#: 1386)767-1774 Fax#: (3-161767-65155 Email:'Iebpe@bellsouth.net PAGE © COPYRIGHT 2008 3A-1 2" NOT TO BE REPROOUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E.BENNETT.P.E. SCREEN, ACRYLIC & VINYL ROOMS SECTION 3A F: : I Table 3A.2.1 Allowable Upright Heights, Chair Rail Spans or Header Spans for Screen, Acrylic or Vinyl Rooms Aluminum Alloy 6063 T5 For 3 second wind gust at 110 MPH velocity;using design load of 13.0#1SF Tributary Load Width W=Purlin Spacing Sections 3'-0" 3'-0" 4--0" 4'-0" 5'-0" 5'S" 6'-0" 6'SV0'-2*' b '-0" TT' Allowable Height 'H'/bending'b'or deflection'd' 2"x 2"x 0.044" Hollow 7'-0" b 6'-11" b 6'-6" b 6'-2" b T-10" h T-7" b T-4- b T-1" 11" b 4'-9" b 2"x 2"x 0.055" Hallow 8'-10" b 8'-2" b 7'-8" b T-2" b 6'-10" b 6'o" b T-3" b 5'-11" -9" b T-7" b 3"x 2"x 0.045" Hollow 8'-4" b 7'-8" b T-2" b 6'-9" b T-5" b 6'-2" b 6-10" b T-a" 5" b 5'-3" b 3"x 2"x 0.070" Hollow 11'-1" b 10'-3" b 9'-7" b T-1" b 8'-7" b T-2" b T-10" b T-7" 3" b 7'-0" b 2"x 3"x 0.045" Hollow 10'-2" b 9'-5" b 8'-9" b T-3" b 7'-10" b T-6' b 7'-2" b 6'-11" 8" b 6'-5" b 2"x 4"x 0.050" Hollow 10'-8" b T-11" b 9'-3" b 8'-9" b 8'-3" b T-11" b T-7" b T-3" 11" b 6'-9" b 2"x 5"x 0.062" Hallow 13'-9" b 12'-9" b 11'-11" h 11'-3" b 10'-3" b 10'-2" b 9'-9" b 9'r4" " b 8'_g^ b 2"z 4"x 0.046" S.M.B. 15'-6" b 14'-4" b 13'-5" h 12'-0" b 12'-0" b 11'-5" b 10'-11" b 10'5" '-2" b 9'-10" b2"x 5"x 0,050" S.M.B. 18'5" 6 17'-1" b 16'-0" b 15'-1" b 14'-4" b 13'-3" b 13'-1" b 12'-7" -1" b 11'-8" bS.M.B. 19'-3" b 17%10" b 16'5" b 15'-9" b 14'-11" b 14'-3" b 13'-0" b 13'-1" -7" b 12'-2" bSnap 9'-2" b 8'-0" b T-11" b 7'S" b 7'-1" b T-9" b 6'-6" b 6'-3" 5-11" b 5'-9" b Z"x 3"x 0.045" Snap 10'-5" b 9'-7" b 8'-11" b 8'S" b T-1" b 7'-8" b 7'-4" b 7'-1" bMb5,-9" '-7" b =XG. 0.045" Snap 11'-3" b 10'-5" b 9'-9" b 9'-2" b 8'-8' b 8'-3" b 7'-11" b T-7" b '_1" b 0.045" Fluted T-1" b 8'-5" b T-10" b T-5" b 7'-0^ b 6'-8" b 6'-5" b 6'-2" b '_9" b.060" Square 11'-2" b 10'-4" b 9'S" b 9'-1" b 9'8" b T-3" b T-11" b T-7" b '-; b.093" Square i6'-0" b 14'-10" b 13'-1113'-1" b 12'-5" b 11'-10" b 11'-4" b 10'-11" b0'-2" b.125" Square 19'-1' b 1T-0" b 16'7" 2'-1" b .125" Square For 3 second wind gust at 120 MPH velocity',using design load of 15.0#1SF Tributary Load Width'+!V'-Purlin Spacing Sections 3'-0" 3'-0" 4'-0" 4'-0" 5'-0" 5'-6" 1 6'-0" 1 6'-0" 1 7'_o^ 7'-6" Allowable Height-'H'/ ending'b'or deflection'd' 2"x 2"x 0.044" Hollow T-11" b 6'-6" b 6-1" b T-9" b T-5" b T-2" b 4'-11" b 4'-9" 3-7--7b 4'_5" b 2"x 2"x 0.055" Hollow 8'-2" b T-T' b 7'-1" b 6-8" b 6'-4" b 6'-1" b T-10" b 5'-7' b 5'-4" b 6-2" b 13"x 2"x 0,045" Hollow 7'-9" b 7'-2" b 6-0" b 6-4" b T-11" b T-0" b 5'S" b 5'-3" b 5'-1" b 4'_11" b 3"x 2"x 0.070" Hollow 10'-4" b 9'-7" b 8'-11" b T-5" b 8'-0" b T-0" b T-4" b T-0" b 6'-9" b 6'-0" b 2"x 3"x 0.045" Hollow T-5" b 8'-9" b 8'-2" b T-9" b T-4* b T-11" b 8'-0" b T-5" 7 6'-2" b T-11" b 2"x 4"x 0.050" Hollow 9'-11" b 9'-2" b 8'-7" b 8'-1" b I b T-4" b 1 7-0" b 6'-9" b 6'S" b T-3" b 2"x 5"x 0.062" Hollow 12'-10" b 11'-11" b 11'-1" b 10'5" b T-11" b 9'S" b 9'-1" b T-9" b 8'-5" b 8'-1" b 12"x 4"x 0.046" S.M.B. 14'-5" b 13'-4" b 12'-6" b 11'-10" b 11'-2" b 10'-8" b 10'-3" b T-10" b 9'-5" b 9'-2" b 2"x 5"x 0.050" S.M.B. 1T-3" b 15'-11" b 14'-11" b 14'-1" b 13'-4" b 12'-9" b 12'-2" b 1l'-6" b 11'-3" b 10'-11" b 2"x 5"x 0.050" S.M.B. 17'-11" b 16'-7" b 15'5" b 14'-8" b 13'-11" b 13'-3" b 12'-6" b 12'-2" b 11'-9" b 11'-4" b 2"x 2"x 0.044" Snap 8'-13' b 7-11" b T5" b 6'-11" b 6'-7" b 6'-4" b 6'-0" b T-9" b 5'-7' b T-5" b 2"x 3"x 0.045" Snap 9'-0" b T-11" b T-S' b 7'-11" b 7'-6" b T-2" b 6'-10" b T-T' b 6'-4"'. b 6'-1" b 2"x 4"x 0.045" Snap 10'-5" b 9'-8" b 9'-1" b 8'-6" b 8'-1" b T-9" b T-5" b 7'-1" b 6'-10" b 6'-7" b 3"x 3"x 0.045" Fluted T-5" b T-10^ b Tom" b 6'-11" b 6'-6" b 6'-3" b 5-11" b 5'-9" b 5'S" b 5'-4" b 3"x 3"x 0.060" Square 10'-5" b 9'-7" b T-11" b T--S" b 8'-0" b T-8" b 7-4" b T-1" b T-10" b 6'-7" b 3"x 3"x 0.093" Square 14'-11" b 13'-10" b 12'-11" b 12'-2" b 11'-7" b 11'-0" b 10'-7" b 10'-2" b 9'-9" b 9'-5" b 3"x 3"x 0.125" Square 17-9" b 16'-0" b 15'-5" b 14'5" b 13'-9" b 13'-2" b 12'-7" b 12'-1" b 1-1'B" b 11'-3" b 4"x 4"x 0.125" Square 23'-0" b 21'x" b Notes: 1. Above spans do not include length of knee brace. Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 2. Spans may be interpolated. REVISED APRIL 2007 Lawrence E. Bennett, P.E. FL# 16644 CIVIL& STRUCTURAL ENGINEERING P.O.Box 214368,South Daytona,F132121 Telephone#: (386)767-4774 Fax W(386)767-65M Email: I oboe@ be0eouttt.net n ^OP fRiGHT 2008 PAGE v NOTTO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRnTEN PERMISSION OF LAWRENCE E.BENNE r,P.E. 3A"25 r 0 y r d N ' N � I �4°2!'3 � n o0 40 22r 33pE. s .o8�FIELo) _a • O l N .00s O O O V d 2 2� N ma tam, 0 v � y "� �-3 co 0 00 rn ro � Z m IqM �8 coi � . • � a • m 0m � < m a m �\ m -4m b ' z ;o m m in 0 m 456 (if � N M!: �� O 00 vv a 94.9 s, caro U00 '(94.86 FIELD) .U, V-Ic ` H Z Q3A 31036 A DRIVE f (PAVED) oz > N �-3 D r Z m to cn = ro O 5C y 6.0' 30l NO m S Z m �nr rr j mo m < C1 Cil a z ai m '�a rC) tiC IID z O C cn Z n xoPw r E., a Ut D � to O F-� CCCi��777 O C D ror �1 U7 m CTt o p� Z yHHH N !FCSyj C00��77 2S off, rrT � i y 25'B.R.L. /* to O H � mro /' p to to �W m ' D y to w S. 070 16' 02"E. D H Z acn m Z D v G1 C/1 L nn m p c /� I m r:, a D-+ z L F I S H �= N n_ n @ m SCS R GHT-O -WA' i-3 NP , l ra. CITY OF ATLANTIC BEACH 08- P7 ° �?` Boo SEMINOLE ROAD.ATLANTIC BEACH,FL 32233 OFFICE:(904)247-5826•FAX NO.:(904)247-5845 _ BUILDING-DEPT�COAB.US DUVAL COUNTY BUILDING PERMIT APPLICATION 2. WORK 3,SQ.FT.UNt7ER ROOF VALUATION OF t.pB ADDRESS: K A /�� D (J / 6.U STRt1CTl1R 6 E '�CC'SRESIDENTIAL : 4.LEGAL DESCMP K ❑ W BUILDING ❑pEMOUTION NG USE ❑COMMERCIAL ❑CONVERTI �A�pITION 8.FIRE SPRiN LOT_.BLOCK_SUB DIVISION ❑ALTERATION ❑ACCESSORY BLDG. ❑YES N/A 7.DESCRIPTION OF WORK ❑REPAIR ❑POOL I SPA ❑NO r • ! _ ❑OTHER 1 J TRACTOR: ARCHITECT!ENGINEER: PROPERTY - - 23. ANY NAME: 15.COMP 9.NAME: u' E NAME: 2nIA13 NO-: �r��j�� 25.STATE F FLORIDA LICENSE NO.: .STATE O 10.ADDRESS. J C 26 SS: ,,.ADDRESS. 2FOhCRCbUff 551C JACKSONVILLE,CL3nL56 .OFFICE PHONE: 28.FAX NO.: If 1 OFFICE PRONE. 20.FAX NO.: ,,. F �{ 12.FAX .:�,�Nr U 29.CELL PHONE: 21.CELL E: _ 13.CELL PHONE: 30 EMAIL ADDRESS: 22.EMAIL ADDRESS: 14.EMAIL ADDRESS: TITLE HOLDER: BONDING COMPANY: MORTGAGE LEER= FEE SIMPLE : OF OTHER THAN owNERt 33 NAME: 35.NAME: 31.NAME: 36 ADDRESS: 34.ADDRESS: 32.ADDRESS: rtify that no work or installation has permit and that all work will be performed to meet the standards of all laws regulating construction in this Application is hereby made to obtain a permit to do the work and installations as indicated.stand. Ice commenced prior to the issuance of a pe months, or if construction or work is suspended or I understand that separate permits must be secured for jurisdiction. This permit becomes null and void if work is not commenced within six( ) abandoned for a period of six (6) months at any time after work is commenced- Air Conditioners,etc. applicable Electrical Work,Plumbing,Signs,Wells,Pools,Furnaces,Boilers,Heaters,Tanks, or use the referenced building or any part therof,until all inspections are finaled and OWNER'S AFFIDAVIT-I certify that all the foregoing information is accurate and that all work will be done in compliance with al app laws regulating construction and zoning.I will not occuPY prior to obtaining a certificate of occupancy or completion issued by the building official,as required by taw. WARNING TO OWNER: *** YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT A NOT NOTICE OF IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PRO COMMENCEMENT MUST BE RECORDED AND POSTED ONG THE CONSULT WIB SITE TH JO OUR HE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OFFaCOMMENCEMENT. OWNER orAGENT t r0*) Agenk of Attorney or Agency Letter Required) • �.. Date: -- Signed: Signed: day of . 2007 in the county of 2007 in the county of Before thi Before me this day of Duval.SL orida•ha ply appeared ,,.e•.,e ra9� Duval.State of Florida,h personably appeared ,.. .:`y^� 0D'es t GQ� G(i�.4- �t I and herrn by himself/herself and affirms that a stateitr < 4254 rns E f�5t2U0bl d�+' herrn by himself!herself and a Lha} ;}« true and rate. Of Inc true and accurate. tiond r Fu 2. .nc ; Nota uWic at Large,Stat `° m:. Notary P is at Large State f £,•,,, .•. onalry Known ❑Produced Identlficab ❑ rsonalry Known *, Produced Idenufi on- Notary Signature: Notary Signature: COAB FORM BLDG01:REVISED:1/102008 EPERMIT Cyry OffA1iANUC BEACH ATIO # D gpG ZONING DEPARTWNT 500 Seminole Road T? Atlantic Beach,Florida 32233 (904)247-5500 (904)247-5545 Fax www.coab.us APPLICATIONTRACKING FORM R IRED DEPT: Y N PLANNING C7 Y N BUILDING Property Addres Y N PUBLIC WORKS N PUBLIC UTILITIES pklzlIlcall FIRE DEPT. Y N UBLIC SAFETY NAPPROVAL DATE: v o REQUIRED AGENCY: RECEIVED BY: INITIAL w w y N D.E.P HUFSTEfLER rr rr D Y N S.J.R.W.M_ CARPER _ Y N ARMY CORPS of ENG CAPPER O Y N HOTELS&RESAURANTS HUFSTEfLER APPLICA T ION STATUS _ _ DATE: CIRCLE ONE: SITE BUILDING DA AP REVIEWED BY: INITIAL: ® ® I ST REV L.AN.NLNG ® ® 2ND REV ® r ING rA PUBLIC WORKS D ��LQro 93 , PUBLIC UTILITIES v7tiG��� FIRE DEPT. PUBLIC SAFETY ® 3RD REV Ll ___ L..+... ..w4�roe,nnxov rreasRAiS6YA�R i'lat L title- A 9400- CITY OF ATLANTIC BEACH PERMIT BUMDI G / ZONING DEPARTNIENT APPLICATION u� h �•-';-�,�?�..,= 000 Seminole Road " '>•.:A V Atlantic Beach,Florida 32233 O (904)247-5-00 8 (904)247-5545 Fax www.coab.ns APPLICATION TRACKING FORM R IRED DEPT: 1 ��� oL Y N PLANNING Property Address: (D J �`� Y P! BUILDING ,,�n D , y� _ Y N PUBLIC WORKS AppH�cante L I t Y ICJ J� IAC 10-N( � N PUBLIC UTILITIES �(QpFIRE DEPT. Project: 1"('l, Y N us IC SAFSTY w 'APPROVAL vREQUIRED AGENCY: RECEIVED BY: INITIAL: DATE: w Y N D.E.P HUFSTETLER ¢� o: � Y N S.J.R.W.M. CARPER _ Y N ARMY CORPS of ENG CAPPER O Y N HOTELS&RESAURA14TS HUFSTETLER APPLICATION STATUS _ CIRCLE ONE: SITE BUILDING DA AP REVIEWED BY: INITIAL: DATE: ® ® 15T REV ® 1/11-4, Soh M11'0 PLANNING BUILDING ® ® 2ND REV ® ® • PUBLIC WORKS PUBLIC UTILITIES FIRE DEPT. PUBLIC SAFETY ® ® 3RD REV .w . .n a <n _ w_ .,T _ TfA___•99���FT,-�.` ..A�—...yd..e .e.n arwn va Aa znarwf.�tta'�f/SAP®6`!F�iTAPY!^411T1iA FYRCYP IIQ LRAl n ha.. A09,00. 03/25/2008 11:05 904 731 5750 4 2475845 N0.139 001 G`t' .4."IY � i'C C ]E1�CL3 f pPLIcATION# TG! ZONING �•. - - � ,9,',,'��1GPr[.v;l►,r?oii1�37.•.3a --- - j FiF� DLFT 4PPLICATIOI�I TF?P,:i��l`.lGFORMrte` -_-- -.�..._.L -- �/ �7z c;net�'y KS 71 F Addrrrvs: i�im�rii s GFNCY' —��-- -— -- PCAR"'- -- �� _�..— p ' '�• _. = Y �j._.....�.t. pl R/1NI(S NUFSZETtF�t Oi -�---- F;tV0 U'i. _.l.L,A_ AP - ll 11V1 "- pP' I( n � I�tf•.NNIld(= . --r-�,-` ` �""�._.i-,2Kp Fry..�_..-.__�� --`...� --••�—_ --' -...�-/J-_- �_. W, ;, l � OAR �'aW el- PUSL1C. FES r i_'1 I ;Fi17�'kv 1 L3 L tL 1 _^ _� PSR-3844 15660 DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH PEF.MIT INFORMATION ---_- --- LOCATION INFORMATION Permit Number: 15550 ,ddress , 700 TRITON ROAD Permit Type: STORAGE SHED ATLANTIC BEACH . FLORIDA32233 :lass of Work: SHED ---------- LEGAL DESCRIPTION - Constr. Type:W00D FRAME Block: Lot : Twp : Proposed Tose: Section: 0 Subd: O Rng' Dwellings : 1 Subdivision' Est . Value: 0 . 00 Improv . Cost . 2 , 300 .00 Total Feet* 37 . 50 Amount Paid: 37 . 50 r" , r , O Q OWNER INFORIa _i jv _'.PPLICATION FEES Name'. JOHN LARIMORE r.rFP�TT Addr : 100 TRITON ROAD A'T'LANTIC BEACH , FLORIDA 322_ Phone: ` 000 1000_ 1100(? --- --- CONTF:A CTOF' INFORMATION Name: PROPERTY C)W VER Addr: Exr , NOTES: zXISTING Shia) ;'0 BE REMOVED NOTICE- INSPECTIONS MUST BE REQUESTED AT LEAST 24 HOURS PRIOR TO INSPECTION BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' IMPROVEMENTS-LIEN LAW CAN RESULT 95 THE PROPERTY OWNER PAYING TWICE FOR BUILDING r m ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF-THIS PEWIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. Operator: CHERYLEData, 1241147 91 . Total payment $37.56 ATLANTIC BEACH BUILDING DEPARTMENT By: CITY OF ATLANTIC BEACH PERMIT APPLICATION REMODEL, ADDITIONS, OR ALTERATIONS MOVING,DEMOL I TIONS Owner(s) : �.(� �r/ r Address: Phone: Lot # Block or Unit # Subdivision: Contractor. State License # Address: Phone No: City State Zip Code Describe work to be done: /'C L 'X Present use of building: !}lac Valuation of Proposed Constructs n: Proposed use: Is this an addition? If yes, what are the dimensions of the added space: ft. X ft. Will the added area be heated and cooled? New electrical (or increase) ? New plumbing fixtures?/`' New fireplace? New Heat/AC? SUBMIT THREE =bfr ERCIAL) TWO (RESIDENTIAL) COMPLETE SETS OF PLANS, INCLUDING SITE PLAN, SURVEY, ENERGY CODE FORDS, NOTICE OF COn-mNCIIMENT, AND OWNER/CONTRACTOR AFFIDAVIT, IF O IS CONTRACTOR. A Signature OWNER: \ Date: Signature CONTRACT Date: O OJ IiP\6 195'7 Sworn to and subsc A oe(SP e this day of OTA Y PUBLIC STATE OF FLORIDA AT LARGE `, ;qrA oY�.. PeAda Am mft +R(j�� MY COMMISSION N CC563881 EXPIREF August 27,2000 BONDED THOU TROY FAIN INSURANCE,INC. CITY OF l��°�cKtic �eacl - ��icda 800 SEMINOLE ROAD ATLANTIC BEACH,FLORIDA 32233-5435 ^-- — TELEPHONE(904)2475800 FAX(904)247-5805 Chapter 489, Florida Statutes,Part I 'CONSTRUCTION CONTRACTING'requires OwnerBuilder to acknowledge the law: DISCLOSURE STATEMENT for Section 489.l 03(7),Florida Statutes: State law requires construction to be done by licensed contractors. You have applied for a permit under the exemption to that law. The exemption allows you as the owner of your property,to act as your own contractor even though you do not have a license. You rust suaervise the construction yourself. You may build or improve a one-family or two-faily residence or a farm outbuilding. You may also build or improve a commercial building at a cost of$25,000 or less. The building_mat be for y r own u1c and occupance. It may not be built for sale or lease. If you sell or lease more than one building you have built yourself within I year after the construction is complete,the law will presume that you built it for sale or lease,which is a violatioin of this exemption. You may not hire in unlicensed person as you contractor. Your construction must be done according to building codes and zoning regulations. It is your responsibility to make sure that people employed by you have licenses regaiad by state law and by coyly or municipal licensing ordinances. Ordinances also allow an Owner to improve their own property when it is for personal or family use,and likewise require all work(except maintenance under 52,000)be under a building permit and pass all normal inspections. The ordinance states owners may physically do work themselves;or qty hire unlicensed workers provided such workers be under "directyAKrvision of the owner,who mast be on the iob site at all times while work is in progress by unlicensed trades people." This does not allow use ofunlicensed contractors. Sind moors u= libe liable Pori =es to workers they hire,the Building Department suggests Worker's Compensation insurance be purchased unless the homeowners insurance policy clearly protects the Owner. Owners hiring workers become employers and should also observe IRS withholding tax and/or Form 1099 requirements on the workers they employ on their improvement work Unlicensed contractors cannot be emnl_oyed Under ami circuu2sanm. Owners being subject to$5,000 penalty under Florida Statute No.455.228(1). An 4ccunational License'is not adequate. The owner should physically seethe county'Certificate of Competency'or the Florida'Contractors Certificate'to ascertain if a person is a licensed contractor. Telephone the Building Department(247-5826)if in doubt. I hereby acknowledge that I have read and understand all the above on this ,('P day of / _, 194 4 Witness,Building Dept,Employee Own wilder ' Y"?,y, Patricia Amonette �'� y ,4j " *; .= MY COMMISSION N CC553881 EXPIRES Address 7 �;.• •0. August 27,2000 �Z7 '0, BONDED THRU TROY FAIN INSURANCE,INC NOTE: Phrases underlined above are emphasized by the Building Phone Department • d N � U I Vld H3d SV't,I HOOIe Qo 1 LSV3 3H1 NO (13SV9 SONIUV38 8'e)3NIl NOIIOIHIS38 9NIOline 1 "A3AMl1S AUVONf109 V SI SIHl 1 S31ON 1 0 olI£'61 f n ave3d„z/1°NnoA E"t ,e '801 r 1(�Yi D '60 MMbz 098 QOM ,E 0 y 71 16"09 I' 34l N ,9 t 6.0 ON, O313a IONOO o3H,7Y w In ��►t, O /1 O 3ON3d d9�' A I 91 i8 � t,J J In llldS,£ _ = kNl7 p 3pN3d ,t to 1 �J 0 O . o. 1100 M330 OOOM 0 .� I a i'�jSa p 2 ,s'0 z N A 313H�N� N o A 3ON3d s O C4 Ip ,A 1IYa 11ldS,E 3AISOMONOO (N W � 13aONOO S 1f m �> m (A 1a0daVO A3vAI!/el3OH34 6 313UDNOD °OC* 9 IO C v S0 A _s OD rn �o a•° o 3AIaO dVO ON 313aONO3 0 3dld NOaI„ZA ONnOj 0 tiZ'se llTire 33 11117dg£d (O73! 0p. •� H►7 N1d34 Q 68 a Z vo (v �1bd�� , ' 0s8 to 1Ngl�,Og 3d14ppbl.t I QNp�`_�. No , / 1 J xOoGG RECEIVED O DEC 1 0 1997 City of Atlantic Beach Building and Zoning G a I ' i V I I I 1 o C � z I ct z � c ^ o M 9 IVED Q DEC 10 1997 City of Atlantic Beach Building and Zoning CITY OF 4A"tib Bwx i-'V1�� -A s, Office of Building Official REQUEST FOR INSPECTION Date ,; 8 y Permit No. 455 V Time r" A.M. Received PM' T� bd Locality Job A ress , Owner's �Winng Name —CONCRETE PLUMBING MECHANICALBUILDING ❑ Air Cond. & ❑ Footir. - Rough Framing — g - Temp Pole _ Top Out C Heating Re Roofing Slab - — Sewer ❑ Fire Place ❑ Insulation C: Lintel Final — Pre Fab READY FOR INSPECTION A.M. Friday f-M Mon. Tues A.M. P.M. Inspection Made -- Final Inspections inspector— — Certificate of Occupancy Date _ PSR-3844 8524 s DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH ----- PERMIT INFORMATION --` LOCATION INFORMATION -- Permit Number : 8524 Address : 700 TRITON ROAD Permit Type : MECHANICAL ATLANTIC BEACH , FLORIDA 32233 class of Work: NEW ----- ----- LEGAL DESCRIPTION ---- Constr . Type: WOOD FRAME Lot : Block : Section: Proposed Use: SINGLE FAMILY Township : RNG: 0 Dwellinas : 1 Code: 0 Subdivision: Estimated Value : 50 . 00 Improv . Cost : 50 . 00 Total Fees : S47 .00 Amount Paid . 547 .00 Date Paid: 5/23/94 HEAT AND AIR IN EXISTING RESIDENCE ----- - - OWNER INFORMATION ------- ---- APPLICATION FEES ----- JOHNI�ARIMORE PERMIT $47 .00 �- 700 TRITON ROAD WATER IMPACT FEE 50 .00 SEWER IMPACT FEE 50 ,00 � ;,�`,'Til BEACH , FLORIDA 32 WATER METER/TAF 50 . 00 RADON GAS-H.R. S . S0 .00 ---- CONTRACTOR INFORMATION - RADON CAB 5% 50 . 00 Name ALERT HEATING & AIR CAPITAL IMPROVE. 50 .00 Addrasv i!,1'4-,? LE)`" .TURNER ROAD SEWER TAP S0 . 0f 7A�KSONVILLE . FL 32218 CROSS CONNECTION 50 .00 CACe x.36, 1 'Type : SEC-H IMPACT FEE $0 . 00 NOTES: NOTICE —ALL CONCRETE FORMS AND FOOTINGS MUST BE INSPECTED BEFORE POURING PERMIT VOID SIX MONTHS AFTER DATE OF ISSUE BUILDING MATERIAL, RUBBISH AND DEBRIS FROM THIS WORK MUST NOT BE PLACED IN PUBLIC SPACE,AND MUST BE CLEARED UP AND HAULED AWAY BY EITHER CONTRACTOR OR OWNER "FAILURE TO COMPLY WITH THE MECHANICS' BUILDING IMPROVEMENTS LIEN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR ISSUED ACCORDING TO APPROVED PLANS WHICH ARE PART OF THIS PERMIT AND SUBJECT TO REVOCATION FOR VIOLATION OF APPLICABLE PROVISIONS OF LAW. 000000000 000000000 $47.00 14 ATLANTIC BEACH BUILDING DEPARTMENT Date: 6/23/94 01 Rcpt: 00GL728 CHECKS 7583 BY: ;� BUILDING AND ZONING INSPECTION DIVISION CITY OF ATLANTIC BEACH ATLANTIC BEACH, FLORIDA 32233 APPLICATION FOR MECHANICAL PERMIT CALL-IN NUMBER IMPORTANT — Applicant to complete all items in sections I, Il, III, and IV. LOCATION Street Address: � OF Intersecting Streets: Between And BUILDING Sub-division II. IDENTIFICATION — To be completed by all applicants In consideration of permit given for doing the work as described in the above statement we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Jacksonyille ordinances and standards of good practice listed therein. Nance of Mechanical Contractors ^CO��� Contractor (Print) '�� ( � (–I n a` �'i f Master A Name of -- / Property Owner 4w Authorized of Owner / L / r�� � Signature of g K /wthorised Agent C./"���I UC Architect or Engineer Ill. GENERAL INFORMATION A' Typo of heating fuel: B. IS OTHER CONSTRUCTION BEIt/Ct DONE ON 'r� uric THIS BUILDING OR SITE? I _)() ❑ Gas_❑ LP ❑ Natural ❑ Central Utility IF YES, GIVE NUMBER OF CONSTRUCTION ❑ 07 PERMIT ❑ other — Specify IV. MECHANICAL EQUIPMENT TO SE INSTALLED NATURE OF WORK (P,ev;de compiete list of compononh on beck of this form) M Residential or ❑ Commercial C) Heat ❑ Space ❑ Recossed O Control O Hoo► �❑,/ New Building Q Air Condrf;on;ng: ❑ Room ❑ Centro) LX Existing Building ❑ /❑ Replacement of existing system Duct, Systom: Matoriat Thickaoasa t GCJ C� c f T New Installation(No system previously Installed) Maximum capacity Q Extension or add-on to existing system ❑ Refrigeration ❑ Other — Specify ❑ Cooling tourer: Capacity 9-p-m. ❑ Fire sprinklers: Number of head ❑ Elevator ❑ MOR" ❑ Escalator (number) THIS SPACE FOR OFFICE USE ONLY ❑ Gasoline Pum; (number) (R000Md) Q Tanks (number) Remarks Q LPG container (number) 13 Uafirod Preuuns ven*' Permit Approved by pat- O briers O Permit Fee Other — Specify LIST ALL EQUIPMENT AIR CONDITIONING AND REFRIGERATION EQUIPMENT Capacity AWMVW f�, Number Unita Description Model Number manufacturer (Togia) ASMW era,. 2 S . ' r1 GLS HEATING - FURNACES, BOILERS, FIREPLACES Ntmdber Units Descriptim >r (BT[I) TANKS _ Flow Many Nowinat Capacityad Type Liquid Name of Serial AP^6cM°u'8 SDlmem81012 t Contained MaatdachwW No. 7 s7s CITY OF ATLANTIC BEACH, FLORIDA Approved by APPLICATION FOR ELECTRICAL RSRMI' TO THE CHIEF ELECTRAI;, L INSPECTOR. DATE: —Co IMPORTANT NOTICE: IN CONSIDERATION OF , AMIT GIVEN FOR DOING THE WORK AS DESCRIBED IN THE FOLLOWING, M HEREBY AGREE TO PERFORM SAID WORK IN ACCORDANCE WITH THE ATTACHED PLANS ANC SPECIFICATION WHICH ARE A PART HEREOF, AND IN ACCORDANCE WITH THE ELECTRICAL REGULATIONS, COvES ANQ CITY C ATLANTIC BEACH ORDINANCES. ELECTRICAL FIRM: MA�TEFI ELECTa �IA�V SIGNATURE JOURNE�YA 4- ADDRESS: —7 2 BLDG.SIZE BETWEEN: RES.� APT. ( ) COMM.( ) PUBLIC( 1 INDUS.( ) NEW( ) OLD ( HEW.( 1 ADDITION ( ) TRAILER ( 1 TEMP.( I SIGNS ( 1 —SQ.FT. \ • SERVICE: NEW( ) INCREASE 1% R.EPAIR ( ► FEE 00l ICTOR SIZE AMPS ) U COPPER I ALUM. 6 A SLWIT.,H OR BREAKER AMPS PH 3w -'V T ZG2BACEINAXaS� EXIST.SEI.V.SIZE AMPS ( PH WVOLT RACEWAY FEEDERS NO. SIZE NO. SIZE NO. SIZE LIGHTING OUTLETS CONCEALED OPEN TOTAL RECEPTACLES CONCEALED OPEN TOTAL 0.30 AMPS. 31.100 AMPS. SWITCHES INCANGESCENT FLUORESCENT 81 M.V. FIXED 0.100 AMPS. OVCR APPa_IANCES _ BELL TRANSF. AIR N.P. RATING H.P. R. .NG CONDITIONING COMP.MOTOR JHER MOTORS AMPS CEIL HEAT: KW-HEAT lU l•cN a• OVER MOTORS H.P. I VOLTAGE PHS NO. 1 H.P. VOLTAGE PHS MISCELLANEOUS 14-Do S -7i 0 TRANSFORMERS: UNDER 600 V. OVER 600 V. NO. KVA IND. KVA _ NO.NEON TRANSF. NO. VA. MA. MOTOR SIZE SWITCH fLASHE. EACH SIGN yV .._ FORWARDED s TOTAL FEES y�3'S� r _ JN CITY OF Awa - �7&uda 800_ SEMS OLE ROAD ATLANTIC BEAC ,FLORIDA 32233-5445 TELEPHONE(904)247-5800 iz FAX(904)247-5805 March 19, 1993 Edward Beach 700 Triton Road Atlantic Beach, FL 32233 Dear Mr . Beach: Our records indicate that you are the owner of the following property in the City of Atlantic Beach, Florida : 700 Triton Road a/k/a Lot 22 , Block 14, Royal Palms Unit 2A RE#171340-0000-0 Investigation of this property discloses that I have found and determined that a public nuisance exists thereon so as to constitute a violation of City of Atlantic Beach Ordinance Section 24-163(a) ( 2 ) i .e. Lifetime Motor Home in front yard setback line. You are hereby notified that unless the condition above described is remedied within thirty (30 ) days from the date of your receipt hereof , this case will be turned over to the Code Enforcement Board. Under Florida Statute 162 . 09 , the Code Enforcement Board may impose fines of up to $250 .00 per day for a first violation and $500 . 00 per day for a repeat violation. Sincerely , GrunewaId Code Enforcement Officer KWG/pah ` Enclosure cc : City Manager CERTIFIED MAIL RETURN RECEIPT REQUESTED I NOTICE TO THE OWNER AND ALL PERSONS INTERESTED IN THE ATTACHED PROPERTY This property, to wit: �1�,�"7"��� ,�'�r�,z ,/o---�" C3- located at: 741 �''�� Tis'`— z ` is improperly stored and is in violation of the Ordinance Code of the City of Atlantic Beach, Florida; Chapter 21, Article II, Division 1 , Section 21-24 (a) and must be removed within ten (10) days otherwise it shall be presumed to be abandoned property and may be removed and destroyed by order of the City of Atlantic Beach. If the property is a motor vehicle, the owner will be liable for the costs of removal and destruction. Dated: ���y 3 Signed: Code o`rcement Officer City of Atlantic Beach 800 Seminole Road Atlantic Beach, Florida 32233 (904) 247-5826 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD § 24-161 ATLANTIC BEACH CODE ATLANTIC BEACH, FL 32233-5415 additional space for each twenty thousand(20,000)square feet of gross floor area, or fraction thereof, over and above the first ten thousand(10,000)square feet. (i) Method of reguesting deviations frons the regrrironwnts of this -<O('tiorr. (1) Deviations from the requirenxmt.s of this section shall be accomplished h'y filing with the appropriate administrative official an application for an exception which said application shall follow the procedures set forth ill section 2.1-63 herein. (Ord. No. 90.82-74, § 2(IIl,11,9), 7-26-82; Ord. No.90-85-92, § 1, 7 8 tip);Ord. No. 4)087-119. 4-27-87) Cross reference—Stopping, standing and parking generally, § 21-16 et seq. Sec. 24162. Parking lots. Off-street parking lots shall be a permissible use by exception in all districts where such lots are within four hundred (400) feet of a premises requiring off-street parking, provided such lots in residential districts shall also conform to the following: (1) Such parking lots may be permitted only between the principal use and the nearest street in the residential district. (2) An approved wall, fencing, shrubbery or as otherwise required by the planning agency and the city commission shall be erected along edges of portions of such lots as adjoin land in the residential district unless releases are secured from all adjoining property owners. Height limitations as required in other sections of this article shall not apply. (3) No source of illumination for the lots shall be directly visible from any window in any residence in the residential district. (4) There shall be no sales or service activity of any kind on any parking lot unless a � permit is applied for and is granted by the administrative official. (Ord. No. 90-82-74, § 2(I11, H, 10), 7-26-82) Cross reference—Stopping, standing and parking generally, § 21-16 et seq.' Sec. 24163. Storage and parking of vehicles and equipment in residential districts. (a) Commercial vehicles of less than eighteen thousand five hundred(18,500)gross vehi- cle weight, and trailers of all types, including travel, boat, camping and hauling, shall not be parked or stored on any lot occupied by a dwelling or on any lot in any residential district, except in accordance with the following requirements: (1) No more than one (1) commercial vehicle per dwelling shall be permitted; and in no case shall a commercial vehicle used for hauling explosives, gasoline or liquefied petroleum products be permitted; (2) Travel trailers, motor homes, hauling trailers or boat trailers shall be permitted if parked or stored behind the front yard building line; (3) A travel trailer or motor home shall not be occupied, either temporarily or perma- nently, while it is parked or stored in any area except in a trailer park authorized under this article; Supp.No.6 1460 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD § 24-161 ATLANTIC BEACH CODE ATLANTIC BEACH, FL 32233-5445 additional space for each twenty thousand(20,000)square feet of gross floor area, or fraction thereof,over and above the first ten thousand(10,000)square feet.. (i) Method of requesting deviations from the requirements of this section. (1) Deviations from the requirements of this section shall be accomplished by filing with the appropriate administrative official an application for in exception which said application shall follow the procedures set forth in section 24-63 herein. (Ord. No.90-82-74, § 2(III,H,9),7-26-82; Ord. No.90-85-92, § 1, 7-8-85); Ord.No.90-87-119. § 1, 4-27-87) Cross reference—Stopping,standing and parking generally, § 21-16 et seq. Sec. 24162. Parking lots. Off-street parking lots shall be a permissible use by exception in all districts where such lots are within four hundred (400) feet of a premises requiring off-street parking, provided such lots in residential districts shall also conform to the following: (1) Such parking lots may be permitted only between the principal use and the nearest street in the residential district. (2) An approved wall, fencing, shrubbery or as otherwise required by the planning agency and the city commission shall be erected along edges of portions of such lots as adjoin land in the residential district unless releases are secured from all adjoining property owners. Height limitations as required in other sections of this article shall not apply. (3) No source of illumination for the lots shall be directly visible from any window in any residence in the residential district. (4) There shall be no sales or service activity of any kind on any parking lot unless a permit is applied for and is granted by the administrative official. (Ord. No. 90-82-74, § 2(III, H, 10), 7-26-82) Cross reference—Stopping, standing and parking generally, § 21-16 et seq. Sec. 24163. Storage and parking of vehicles and equipment in residential districts.. (a) Commercial vehicles of less than eighteen thousand five hundred(18,500)gross vehi- cle weight, and trailers of all types, including travel,boat, camping and hauling, shall not be parked or stored on any lot occupied by a dwelling or on any lot in any residential district, except in accordance with the following requirements: (1) No more than one(1)commercial vehicle per dwelling shall be permitted; and in no case shall a commercial vehicle used for hauling explosives, gasoline or liquefied petroleum products be permitted; (2) Travel trailers, motor homes, hauling trailers or boat trailers shall be permitted if parked or stored behind the front yard building line; (3) A travel trailer or motor home shall not be occupied, either temporarily or perma- nently, while it is parked or stored in any area except in a trailer park authorized under this article; Supp.No.6 1460 ZONING AND SUBDIVISION REGULATIONS § 24-17 building and construction or other regulations controlling the development of land. The various types of city regulations controlling the development of land within the city may be combined in totality in a single document known as the"Land Development Code"of the city. Landscaping shall mean any of the following or combination thereof. living materials, such as but not limited to, grass, ground covers, shrubs, vines, hedges, trees or palms; and nonliving durable materials commonly used in landscaping, such as but not limited ta, rocks, pebbles, sand, walls, fences, berms, sculptures and fountains, but excluding paving. Laundry, self-service shall mean a business that provides home-type clothes washing and drying or ironing machines for hire to be used by customers on the premises. Live entertainment includes, but is not limited to, singers, pianists, musicians, musical groups, bands, vocal or instrumental dancers, theatrical shows, magicians, performers, come- dians and all fashions, forms and media of entertainment carried on and conducted in the presence of and for the entertainment and amusement of others and as distinguished from records, tapes, pictures and other forms of reproduced or transmitted entertainment. Living area shall mean the minimum floor area of a residential dwelling unit, as mea- sured by its exterior dimensions,having access from within the main living area,exclusive of carports, porches, sheds, garages and utility rooms which are not within the walls of a dwelling. Loading space shall mean a space within the main building or on the same lot, providing for the standing, loading or unloading of trucks or other motor vehicles. Lot shall mean a parcel of land occupied or intended for occupancy by a use p^rmitted in this chapter,including at least one(1)main building together with its accessory buildings,the yard areas and parking spaces required by this chapter and having its principal frontage upon a publicly-owned or maintained street. The term lot shall include plot or parcel. Lot, corner shall mean a lot abutting upon two(2)or more streets or at a street intersec- tion or at a street corner having an interior angle not greater than one hundred thirty-five Supp.No.12 1412.1 ZONING AND SUBDIVISION REGULATIONS § 24-17 (135)degrees. The exterior lot line of the narrowest side of the lot abutting the street shall be considered the front yard.The exterior lot line of the longest side of the lot abutting the street shall be considered a side yard and shall have a minimum setback of fifteen (15) feet. The opposite side yard shall conform to the minimum side yard requirement of the district in which it is located. The rear yard shall have a minimum setback of twenty (20)feet. Lot coverage shall mean the area of the lot covered by the ground floor of all principal and accessory uses and structures, including all areas covered by the roof of such uses and structures, measured along the exterior faces of the walls, along the foundation wall line, between the exterior faces of supporting columns,from the center line of walls separating two (2) buildings or as a combination of the foregoing, whichever produces the greatest total ground coverage for such uses and structures. Lot depth shall mean the distance measured from the middle point of the front line to the middle point of the opposite rear line of the lot. Lot, double frontage shall mean a double frontage or through lot that has frontage on two (2) nonintercepting streets. On through lots between Beach Avenue and the Atlantic Ocean, the applicable front setback requirement shall apply to the yard which faces the Atlantic Ocean.The applicable front setback requirement on through lots between Beach Avenue and Ocean Boulevard shall be the yard which faces Ocean Boulevard. Lot line shall mean the legal boundary line of a lot. Lot of record shall mean a lot which is part of a subdivision, the map of which has been recorded in the office of the clerk of the circuit court,or a parcel of land the deed of which was recorded in the office of the clerk of the circuit court. Lot or site area shall mean the horizontal plane area within the lot lines,expressed in this chapter in square feet or square acres,exclusive of public or private dedications. Lot width shall mean the mean horizontal distance between the side lot lines, measured at right angles to its depth. Marina shall mean an establishment with a waterfront location for the purpose of storing watercraft and pleasure boats on land, in buildings, in slips or on boat lifts, and including accessory facilities for purposes such as refueling, minor repair and launching. Mean high water shall mean the average height of the high waters over a nineteen(19) year period or for shorter periods of observations;the average height of the high waters after corrections are applied to eliminate known variations and to reduce the result to the equiva- lent of a mean nineteen(19)year value, as defined in F.S. Ch. 253. Mobile home shall mean a movable or portable detached single-family dwelling designed for and capable of being used for long-term occupancy, designed to be transported after fabrication on its own permanent chassis and wheels, arriving at the site substantially complete, of such size and weight as to require special highway movements permits, and in Supp.No.5 1413 FOR OFFICE USE ONLY Date-.3.—/*---------------19,6/ Permit #-.6..Z.35_­Fee ............. 060 CITY OF ATLANTIC BEACH Valuation $ ------------ .............. FLORIDA HouseI.V7--------- fir t--------------- ---------------------------------------------------------------------------- APPLICATION FOR BUILDING PERMIT ............................................................................ ............................................................................ Application is hereby made for the -approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure described. This application is made in compliance and conformity with the Building Ordinance of the City of Atlantic Beach, Florida, and all provisions of the Laws of the State of Florida, all ordinances of the City of Atlantic Beach and all rules and regulations of the Building Department of the City of Atlantic Beach, shall be complied with, whether herein specified or not. The Contractor or Owner-Builder who has been issued a Building Permit is automatically responsible to ascertain that all sub- contractors engaged by him are duly licensed in the City of Atlantic Beach,Florida. To prevent delay or embarrasment regard- ing intermediate or final inspections it ed that a list of s -contractors be submitted to this office so that licenses can be verified. 19--- OwnerJv, ---- ...........(:�O------------Address------------------------------------------•----------------Telephone No.--------------------------- Architect---------------------------------------- -- -------------------------------------------------kddress------------------------------------------------------------Telephone No------------------------ ContractorBuilder---------_-------- -----------------------------Address-----------------------------------------------------------Telephone No.---- ---------------------- Lot No---------------C� 6PAZ".el----- -------------Zone----------------- ' --------Zone--_------------- -------------------------Block No-------- -----------Sub Divisi../'�d/. --------and------------------------------ ---------------Sts- . ..."'----Street-------------------------Side Between_._------------------------------------- ,04C)._,n � Valuation $-----------------------600 IT----.-.For what purpose will building be used--------------------------_---------Type of construction_.._._.___....._.___._.____...____ Dimensions of Building_,254__JV__ --Dimensions _of .... . of Footings---/ A?V----------------- - Size of Piers.----.----- -----------------------Size of Sills-.-----------------------------Greatest Sill Span in ft.-.------------------------Type Roof A _,e_d1 How will Building be Heated 9 a_ _ ---Will Building be on Solid or Filled Ground?__ 1_0-_------------ , 4/_ I py Size of Ceiling Joists.__.���-----.......... Distance on Centers__._...._--�ZY-----------------------_, Greatest Span.._...._._......._..__..___._..___...__.--- Size of Floor Joists-------------------------------------------.,Distance on Centers._..------ ----- --------------------- Greatest Span---------------- ---------------- Py Size of Rafters----------------- ------------------------­--------.Distance on Centers ----- -------------------------------- Greatest Span------------------------------------------- ty This rectangle is to represent the lot. Locate the building or buildings in the right position. Give distance in feet from all lot-lines and existing buildings. REAR LOT LINE Two copies of plans and specifications shall be submitted with application. Inspections required. 1. When steel is in place and ready to pour footing. 2. When steel is in place and ready to pour columns and/or lintel. z Z 3. When steel is in place and ready to pour beam. F, E-4 4. When framing is completed. 5. When rough plumbing is completed,and ready to cover up. 6. When septic tank drain field or sewer is laid but before it is covered. 7. Electrical inspection by City of Jacksonville. 8. Final inspection. Note: In case of any rejection,re-inspection MUST be called for after corrections are made. FRONT OF LOT In consideration of permit given for doing the work as described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications, which are a part hereof, and in accordance with the building regulations of the City of Atlantic each. ­a/ Signature of Builde�,K_: . ...... Address---------------------------- -------------------------------------------_------------------- x'_, ------------4...A" Signatureof Owner.. -------------••---------------------•---........------•---•--•---• Address.