2078 Beach Ave 2013 HVAC S f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD r� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003555 Date 10/22/13 Property Address . . . . . . 2078 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- SHEPHERD ROBIN W & CHRISTINA DONOVAN HEATING & AIR 2077 BEACH AVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322335934 JACKSONVILLE BEACH FL 32250 (904) 241-3785 -------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 115 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/20/14 ----------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------------------ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 115 . 00 115 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 119 . 00 119 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 fOB ADDRESS: 20 r-�g ' a Cr, AV-- PERMIT# PROJECT VALUE $ I2©v ARI# SC-7 (�q REQUIRED Air Handling Equipment Only LAir Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 5 — Heat: Unit Quantity I BTU's Per Unit_Ly o o� Seer Rating I s Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name Rdb,n Phone Number 3 �- 19 9/ dechanical Company ' Jl}7��1�G�_ He ct 2_ Office Phone Z 0-7S'5 Fax 2`/13215 ;o. Address: 3 AJc S City 1&, State �t Zip322S0 .icense Holder(Print): l i I State Certification/Registration# CICO 3 Q 7h Votarized Signature of License Holder �✓ ;k,.7; RICHARD TOMPKINS Before me this 2( day of Cr n 20 Commission#FF 040399 Expires July 29,2017 Signature of Notary Public / BWWW Tluu Troy Fain Inaiance Project +� wrightsoft� J Summary M*: 10121IM3 Entire House By: Brandon Zahade Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon(Hdonovanac.com For: Shepherd 2078 Beach Ave, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 of Inside db 68 OF Inside db 75 20 °F Design TD 29 OF Design TD L Daily range Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23790 Btuh Structure 25120 Btuh Ducts 11327 Btuh Ducts 16371 Btuh Central vent (52 cfm) 1644 Btuh Central vent (52 cfm) 1134 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36761 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 42624 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1876 Btuh Fireplaces 1 (Average) Structure Ducts 3824 Btuh Heating Cooling Central vent (52 cfm) 1866 Btuh Area (ft2 2160 2160 Equipment latent load 7566 Btuh Volume k 19440 19440 Air changes/hour 0.38 0.16 Equipment total load 50191 Btuh Equiv.AVF (cfm) 124 52 Req. total capacity at 0.70 SHR 5.1 ton Heating Equipment Summary Cooling Equipment Summary Make TEMPSTAR Make TEMPSTAR Trade Trade Model NXH560 Cond NXH560 ARI ref no. 3670900 Coil FX4X60 ARI ref no. 3670900 15 SEER Efficiency 8.5 HSPF Efficiency Heating input Sensible cooling 43982 Btuh Heating output 62519 Btuh @ 47°F Latent cooling 18849 Btuh Temperature rise 27 OF Total cooling 62831 Btuh Actual air flow 2094 cfm Actual air flow 2094 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r +}� wriio"tsc ft Right-Suite®Universal 7.1.01 RSU05996 2013-Oct-21 10:33:57 ACCA C:\Users\Sales\Documents\Wrightsoft HVAC\5 TON.rup Calc=MJ8 Orientation=N Page 1