618 Stocks St 2013 HVAC Jsf v CITY OF ATLANTIC BEACH
r tF
s 800 SEMINOLE ROAD
J ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003607 Date 11/04/13
Property Address . . . . . . 618 STOCKS ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
--------------------------------------------------------------
Application desc
AHU & CONDENSER
------------------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
BURGOS, DANIEL R DONOVAN HEATING & AIR
381 SEMINOLE ROAD 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 322332536 JACKSONVILLE BEACH FL 32250
(904) 241-3785
---------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 5/03/14
-----------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- --------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
10B ADDRESS: 6i I� S'f'oC K 9,� PERMIT#
PROJECT VALUE $ 3300 ARI# 3-7 14, 0-4-2—REQ UIRED
Air Handling Equipment Only 2�Air Handling Unit & Condenser Condenser Only
4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity 1 BTU's Per Unit 0.000 Seer Rating
REQUIRED
Duct Systems: Total CFM
IRE PREVENTION (Requires 3 sets of plans)
Fire Sprinkler System Quantity
Fire Standpipe Quantity requires 3 sets of plans)
(Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires
3 sets of plans)
Commercial Hoods Quantity
Fire Suppression Systems Quantity (Requires 3 sets of plans)
Z IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate a provisions of any other state or local law regulation construction or the performance of construction.
'roperly Owners Name 1 G Y` 0-S Phone Number
dechanical Company ���,� Jor1 E� A�$ Office Phone 2 4 t 37 t Fax 2 Y1 3RY'
ty 5Ax �^ State F l Zip327- o
;o. Address: 3lS L, ��ir S - Ci
,icense Holder(Print): State Certification/Registration#
notarized Signature of License Holder
Before me this 31 day of OC- 20 13
tiny.ry, ., RICHARD TOMPKINS 0 �-6
Commission#FF 040399
a:, a Expires July 29,2017 Signature of Notary Public
Banded Tieu Troy Fein Ineurence 800385-7019
Job:
wri htsoft Project Summary Date: October 15,2013
9 Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach, FL32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project • f
For: Dan Burgos
618 Stocks Rd,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 70 OF Inside db 76 OF
Design TD 31 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11282 Btuh Structure 15262 Btuh
Ducts 3353 Btuh Ducts 4753 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
piping 0 Btuh
Equipment load 14636 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20015 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2253 Btuh
Fireplaces 0 Structure Ducts 1014 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area (ft2) 1324 1324 Equipment latent load 3267 Btuh
Volume (ft') 11916 11916
Air changes/hour 0.45 0.23 Equipment total load 23282 Btuh
Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R41 OA HP
Model N4H330A(G)KE* Cond N4H330A(G)KE*
AHRI ref no3718047 Coil FEM4P30**A*
AHRI ref no3718047
Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER
Heating input Sensible cooling 21000 Btuh
Heating output 30000 Btuh @ 47°F Latent cooling 9000 Btuh
30000 Btuh
Temperature nse 27 OF Total cooling
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.068 cfm/Btuh Air flow factor 0.050 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Oct-31 10:46:08
wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1
ACC' C\Users\Owner\Documents\wrightsoft HVAC\Bogus 2.5 ton_rup Calc=MJ8 Front Door faces E