618 Stocks St 2013 HVAC Jsf v CITY OF ATLANTIC BEACH r tF s 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003607 Date 11/04/13 Property Address . . . . . . 618 STOCKS ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -------------------------------------------------------------- Application desc AHU & CONDENSER ------------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- BURGOS, DANIEL R DONOVAN HEATING & AIR 381 SEMINOLE ROAD 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322332536 JACKSONVILLE BEACH FL 32250 (904) 241-3785 --------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/03/14 ----------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- -------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 10B ADDRESS: 6i I� S'f'oC K 9,� PERMIT# PROJECT VALUE $ 3300 ARI# 3-7 14, 0-4-2—REQ UIRED Air Handling Equipment Only 2�Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity 1 BTU's Per Unit 0.000 Seer Rating REQUIRED Duct Systems: Total CFM IRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity Fire Standpipe Quantity requires 3 sets of plans) (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity Fire Suppression Systems Quantity (Requires 3 sets of plans) Z IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate a provisions of any other state or local law regulation construction or the performance of construction. 'roperly Owners Name 1 G Y` 0-S Phone Number dechanical Company ���,� Jor1 E� A�$ Office Phone 2 4 t 37 t Fax 2 Y1 3RY' ty 5Ax �^ State F l Zip327- o ;o. Address: 3lS L, ��ir S - Ci ,icense Holder(Print): State Certification/Registration# notarized Signature of License Holder Before me this 31 day of OC- 20 13 tiny.ry, ., RICHARD TOMPKINS 0 �-6 Commission#FF 040399 a:, a Expires July 29,2017 Signature of Notary Public Banded Tieu Troy Fein Ineurence 800385-7019 Job: wri htsoft Project Summary Date: October 15,2013 9 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project • f For: Dan Burgos 618 Stocks Rd,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 76 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Btuh Structure 15262 Btuh Ducts 3353 Btuh Ducts 4753 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh piping 0 Btuh Equipment load 14636 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20015 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2253 Btuh Fireplaces 0 Structure Ducts 1014 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft2) 1324 1324 Equipment latent load 3267 Btuh Volume (ft') 11916 11916 Air changes/hour 0.45 0.23 Equipment total load 23282 Btuh Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R41 OA HP Model N4H330A(G)KE* Cond N4H330A(G)KE* AHRI ref no3718047 Coil FEM4P30**A* AHRI ref no3718047 Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 21000 Btuh Heating output 30000 Btuh @ 47°F Latent cooling 9000 Btuh 30000 Btuh Temperature nse 27 OF Total cooling Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Oct-31 10:46:08 wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1 ACC' C\Users\Owner\Documents\wrightsoft HVAC\Bogus 2.5 ton_rup Calc=MJ8 Front Door faces E