Loading...
541 Beach Ave 2013 HVAC (2) CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD `� sY ATLANTIC BEACH,FL 32233 J INSPECTION PHONE LINE 247-5814 �0A Application Number . . . . . 13-00003648 Date 11/12/13 Property Address . . . . . . 541 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 -------------------------------- Application desc 1 cu 1 ahu 4 tons ------------------------------- Owner Contractor _ _ _ -------------- ---------- PETERSEN PETER E REVOVAVL TRUS 1FLORIDA AFHEATING & AIR 210 541 BEACH AVE FL 32266 ATLANTIC BEACH FL 322335323 NEPTUNE BEACH 721 ----- ------ Permit . , MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee . . . . 107 . 00 0 Issue Date Valuation Expiration Date . . 5/11/14 ----- 00 Other Fees STATE MECH DCA SURCHARGE 2 • STATE MECH DBPR SURCHARGE 2 . 00 ------------------______ ---- Fee summary Charged Paid Credited ----Due--- . 00 _ _ ---------- ----- ---------- - . 00 Permit Fee Total 107 . 00 107 . 00 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: S(-I A&'4 c-!7 A V Z PERMITado # PROJECT VALUE $ !/ 100 - ARI#SS 110-3 REQUIRED Air Handling Equipment Only _Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Heat: Unit Quantity I BTU's Per Unit yg,avia Seer Rating—(-3— Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) EIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: srmit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or it. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. roperty Owners Name ti, p SOv` Phone Number [echanical Company r'(,� 1��iA-1�'� Office Phoneay�•G7� Fax 173?7 :). Address: 013 3 /f Th City TA,.yc &If State F1 Zip 39050 icense Holder (Print): IA•tv%.� State Certification/Registration#C#+r-&S? flys 9tariza [iPr .. ;,. 'v1Y COMMISSION#DD 957 rc; day ' EXPIRES:February 14,2W, Te e this ��-- fi pF Ft Bonded Thru Wiry public Underwri ers . "" 'Sig ure of Notary Publi Job: 111213 RiDRIGUEG Project Summary Date: Nov 12,2013 Entire House By: ERIN RODRIGUEZ energy consiting For: PETERSON 541 BEACH AVE,ATLANTIC BEACJ, FL 32233 Notes: HUXHAM-CHANGE OUT Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions 39 'F Outside db 92 'F Outside db 68 'F Inside db 74 'F Inside db 29 of Design TD 18 'F Design TD Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing 22498 Btuh Structure 22199 Btuh Structure 8372 Btuh Ducts 11750 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping 30870 Btuh Use manufacturer's data n Equipment load Rate/swing multiplier 0.97 Infiltration Equipment sensible load 32931 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2629 Btuh Fireplaces 0 Structure Ducts 2954 Btuh Heating Cooling Central vent(0 cfm) p Btuh 5583 Btuh Area(ftp 2291 2291 Equipment latent load Volume(ft3) 18328 18328 Equipment total load 38514 Btuh Air changes/hour 0.41 0.21 Equiv.AVF (cfm) 125 64 Req.total capacity at 0.70 SHR 3.9 ton HCooling Equipment Summary Heating Equipment Summary Make Trane Make Trane Trade XR13 WEATHERTRON Trade XR13 WEATHERTRON Model 4TWR3048 Cond 4T VR3048 Coil TEM3AOC48 AHRI ref 5919030 AHRI ref 5919030 11.0 EER, 13.3 SEER Efficiency 8 HSPF Efficiency 32200 Btuh Heating input Sensible cooling 13800 Btuh Heating output 45000 Btuh @ 47'F Latent cooling 46000 Btuh 27 'F Total cooling 1533 cfm Temperature rise27 cfm Actual air flow Actual air flow 0.045 cfm/Btuh Air flow factor 0.050 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0.86 Load sensible heat ratio Space thermostat Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Nov-1206:55:04 Page 1 + wrightsoft Right-Suite®Universal 2012 12.1.08 RSU01508 ...\Wrightsoft HVAC\Template\HUXHAM-PETERSON.rup Calc=MA Front Door faces: W