Loading...
128-4 Seminole Rd 2013 HVAC 'N ,C"� CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003664 Date 11/14/13 Property Address . . . . . . 128 SEMINOLE RD 4 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 3 . 5 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ROBERTS, MORRIS& BARBARA TRUST DONOVAN HEATING & AIR 128-4 SEMINOLE RD 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/13/14 ------------------------ Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 10B ADDRESS: 12 -w',,inA- ifs PERMIT# PROJECT VALUE $ 413-7- ARI# 367 0 87 Z REQUIRED Air Handling Equipment Only A.Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 3-S Heat: Unit Quantity�_ BTU's Per Unit Yz ova Seer RatingREQUIRED Duct Systems: Total CFM IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name P rZ I" 06,YZT5 Phone Number 2Y6 -'7-2Z--7 dechanical Company OEpr Office Phone Z#37K- Fax Zy 37� :o. Address: 3 Ci A.Pe City,1Ax aed. State�j Zip2 � .icense Holder(Print): State Certification/Registration# 3 Notarized Signature of License Holder RICHARD TOMPKINS Before me this day of ®err 20 �3 + � Commission#FF 040399 Expires Jug 2s,20» Signature of Notary Public ')e Balled Thur Fain N�euranca 800.iB5.701>i Pro ect Summa Job: wrightsoft° 1 � Date: 11N1/13 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone: 241-3785 Email:brandon(8donovanac.com Project • • For: ROBERTS 128-4 SEMINOLE,ATLANTIC BEACH, FL 32233 Notes: D- • n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6189 Btuh Ducts 12799 Btuh Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25176 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29357 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1948 Btuh Ducts 2254 Btuh Heating Cooling Central vent (33 cfm) 1196 Btuh Area M2 1794 1794 Equipment latent load 5397 Btuh Volume�ft-) 16146 16146 Air changes/hour 0.45 0.20 Equipment total load 34754 Btuh Equiv.AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model NXH542 Cond NXH542 ARI ref no. 3670872 Coil FXM4X42 ARI ref no. 3670872 Efficiency 8.7 HSPF Efficiency 15 SEER Heating input Sensible cooling 30163 Btuh Heating output 42875 Btuh @ 47°F Latent cooling 12927 Btuh Temperature rise 27 °F Total cooling 43090 Btuh Actual air flow 1436 cfm Actual air flow 1436 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +I.F wrightsoft Right-Suite®Universal 7.1.01 RSU05996 2013-Nov-11 11:31:56 RCCA C:1Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N Page 1