1949 Seminole Rd 2013 HVAC CITY OF ATLANTIC BEAC
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003732 Date 11/22/13
Property Address . . . . . . 1949 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES GEN MF DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 4 tons
-----------------------------------------------------
Owner Contractor
------------------------
OCEAN STATE HEAT & AIR, INC.
MAZUR, KAUNATH TERESA
1949 SEMINOLE ROAD 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 249-8251
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . - . 00
Permit Fee . . . . 107 . 00 Plan Check Fee
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 5/21/14 ---------------
-------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 107 . 00 107 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 111 . 00 111 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION ED
CITY OF ATLANTIC ]BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
L?W . PERIM r
oB ADDRFSS:
PROJECT VALUE $ 10,216
mw AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat Unit Quantity BTU's Per Unit Seer REQULRED
Duct Systems: Total CFM
kEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INS
ARI
LKED
Air Conditioning: Unit Quantity Tons Per Unit REQU
Heat: Unit Quantity BTU's Per Unit_A3L� Seer Rating. /7-?0
Duct Systems: Total CFM REQULKED
M PREVENTION (Requires 3 sets of plans)
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity 0"uires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans) ,,
Fire Suppression Systems Quantity
FIRE PLACES AHSCELLANEOUS:
Prefabricated Fireplace QtY Automobile Lifts BTU's
Gas Piping-Outlets Boilers
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
9 Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
ork is suspended or abandoned fbr six months.I hereby certify that I 1mve TL:ad
Permit becomes void if work does not commence within a six month period or w g this work will be complied with whether specified
this application and know the same to be true and correct Aji provisions of laws and ordinances g0vermn
or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the Perfbrmancr,Of constructim
,7q1-314?
Property Owners NamP In&-Zar, Phone Number.0
C - om,-R one 994MI Fax- -20-VqVI
Mechanical Company oceaA OXX� �- /U city /3&6tate X zip�_2-zxo
Co. Address: /47(e
io i on 0
State. cation/Registrati
License Holder(Print): .7
Notarized Signature of Licenseffo
YVETTE P.MORAIE5
NOTARY PUBLIC Sworn re me this day of
pires WZ`I7
STATrr-OF FLORIDA
Comno EE879174 Si 0 Notary Public
Ey
ACCA Manual "J" Heat Load Calculation Date 11/22/13
Customers Name Teresa Mazur Location 1949 Beach Ave
Type of Construction Heat Transfer Multipliers Area or BTUH
Exposure Notes HEATING COOLING Length HEATING COOLING---�
1 Gross Wall 2,240
213 Windows 1,408
North Al, N, 2 29.0 16.0 88 2,552
East& West AI, E &W, 2 29.0 46.0 178 5,162 8,188
South Al, S, 2 29.0 25.0 80 2,320 2,000
4 Doors
Froot Solid Wood - Panel 27.0 15.8 30 810 474
Patio Solid Wood - Storm 16A 9.7 30 492 291
Other SIcIg GI Dr, S, 2 32.6 25.0 60 1,956 1,500
1,774
5 Net Wall
Area I R- 11, 1/2"Asp. BTrd. 3.2 1.9 1,774 R77
Br 0 0 0
Area 2 R- 13, 1/2"Asp. Brd. 3.0 1.8
3r . 0 0 0
Area 3 R- 13, 1/2"Asp. Brd. 3.0 1.8
6 Ceilings ......
0 0
Area I Attic, R-22 1.9 2.1
Area 2 Attic, R- 19 2.1 2.3 1,546 3,247
Area 3 Attic, R- 19 2.1 2.3
7 Floors
Area I Slab 40.5 0.0 138 5,589 0
Area 2 None 0.0 0.0 0 0
8 Infiltration Winter Summer Avg Cilng Ht 2,726
Poor 1500 - 2100 1.2 0.6 8 13,632
41,436
9 Sub Total BTUH Loss
4,144
10 Duct BTUH Loss .. .............—
11 TOT kL H :ATING LOAD 45,580
12 People and Appliances Bedrooms 6 4,800
13 Sub Total BTUH Gain (Structure) 77777 28,314
15% 4,247
14 Duct BTUH Gain Location Attic
IC
32,561
15 TOTAL SENSIBLE
16 Infiltraton Latent Gain Infit. CFM 198 6,871
920
#People 4
17 People Latent Gain
7,791
TOTAL LATENT
40,352
E199 Total Cooling Load
/-v
This combinatiRn qualifies for a Federal Energy
RAMP, Efficiency Tax Credit when placed in service
M ILI CERTIFIED,. between Feb 17, 2009 and Dec 31, 2013.
www.ahridirectory.org
Certificate of Proddct Ratings
AHRI Certified Reference Number: 4597171 Date: 11/20/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 25VNA048A**30
Indoor Unit Model Number: FE4AN(B,F)005+Ul
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: CARRIER AIR CONDITIONING
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh)-. 46500
EER Rating (Cooling): 13.00*
SEER Rating (Cooling): 17.90*
Heating Capacity(Btuh)@ 47 F: 46500
Region IV HSPF Rating (Heating): 11.45*
Heating Capacity(Btuh)@ 17 F: 47500
MAZUR, TERESA MC0507
1949 SEMINOLE RD
AB, FL 32233 241-3149
1 SYS C/o 11-22-13
Ratings tollowed by an asterisk(*)indicate a voluntary retate of previously published data,unless accompanied with a WAS,which indicates an involuntaiy WM!0
DISCLAIMER resentations,warranties or guarantees as to,and assumes no responsibility for,
AHRI does not endorse the product(s)listed on this Certificate and makes no rep
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at,vww.ahridirectoiY org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced:copie&disseminated;entered into a computer database;or otherwise utilized,in any
form or mariner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION e verified at "Imp, A' Conditioning,Heating,
The information for the model cited on this certificate can 1)
click on-Verity certificate"link and enter the AHRI Certified Reference Number and the date on N%11 aim *1 an"d Refrigeration Institu e
which the certificate was issued,which is listed above,and the Certificate No..which is listed below. CERTIFICATE NO.: 130294535976480960
@2013 Air-Conditioning,Heating,and Refrigeration Institute