1949 Seminole Rd 2013 HVAC CITY OF ATLANTIC BEAC 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003732 Date 11/22/13 Property Address . . . . . . 1949 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 4 tons ----------------------------------------------------- Owner Contractor ------------------------ OCEAN STATE HEAT & AIR, INC. MAZUR, KAUNATH TERESA 1949 SEMINOLE ROAD 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . - . 00 Permit Fee . . . . 107 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/21/14 --------------- ------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION ED CITY OF ATLANTIC ]BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 L?W . PERIM r oB ADDRFSS: PROJECT VALUE $ 10,216 mw AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat Unit Quantity BTU's Per Unit Seer REQULRED Duct Systems: Total CFM kEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INS ARI LKED Air Conditioning: Unit Quantity Tons Per Unit REQU Heat: Unit Quantity BTU's Per Unit_A3L� Seer Rating. /7-?0 Duct Systems: Total CFM REQULKED M PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity 0"uires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) ,, Fire Suppression Systems Quantity FIRE PLACES AHSCELLANEOUS: Prefabricated Fireplace QtY Automobile Lifts BTU's Gas Piping-Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps 9 Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: ork is suspended or abandoned fbr six months.I hereby certify that I 1mve TL:ad Permit becomes void if work does not commence within a six month period or w g this work will be complied with whether specified this application and know the same to be true and correct Aji provisions of laws and ordinances g0vermn or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the Perfbrmancr,Of constructim ,7q1-314? Property Owners NamP In&-Zar, Phone Number.0 C - om,-R one 994MI Fax- -20-VqVI Mechanical Company oceaA OXX� �- /U city /3&6tate X zip�_2-zxo Co. Address: /47(e io i on 0 State. cation/Registrati License Holder(Print): .7 Notarized Signature of Licenseffo YVETTE P.MORAIE5 NOTARY PUBLIC Sworn re me this day of pires WZ`I7 STATrr-OF FLORIDA Comno EE879174 Si 0 Notary Public Ey ACCA Manual "J" Heat Load Calculation Date 11/22/13 Customers Name Teresa Mazur Location 1949 Beach Ave Type of Construction Heat Transfer Multipliers Area or BTUH Exposure Notes HEATING COOLING Length HEATING COOLING---� 1 Gross Wall 2,240 213 Windows 1,408 North Al, N, 2 29.0 16.0 88 2,552 East& West AI, E &W, 2 29.0 46.0 178 5,162 8,188 South Al, S, 2 29.0 25.0 80 2,320 2,000 4 Doors Froot Solid Wood - Panel 27.0 15.8 30 810 474 Patio Solid Wood - Storm 16A 9.7 30 492 291 Other SIcIg GI Dr, S, 2 32.6 25.0 60 1,956 1,500 1,774 5 Net Wall Area I R- 11, 1/2"Asp. BTrd. 3.2 1.9 1,774 R77 Br 0 0 0 Area 2 R- 13, 1/2"Asp. Brd. 3.0 1.8 3r . 0 0 0 Area 3 R- 13, 1/2"Asp. Brd. 3.0 1.8 6 Ceilings ...... 0 0 Area I Attic, R-22 1.9 2.1 Area 2 Attic, R- 19 2.1 2.3 1,546 3,247 Area 3 Attic, R- 19 2.1 2.3 7 Floors Area I Slab 40.5 0.0 138 5,589 0 Area 2 None 0.0 0.0 0 0 8 Infiltration Winter Summer Avg Cilng Ht 2,726 Poor 1500 - 2100 1.2 0.6 8 13,632 41,436 9 Sub Total BTUH Loss 4,144 10 Duct BTUH Loss .. .............— 11 TOT kL H :ATING LOAD 45,580 12 People and Appliances Bedrooms 6 4,800 13 Sub Total BTUH Gain (Structure) 77777 28,314 15% 4,247 14 Duct BTUH Gain Location Attic IC 32,561 15 TOTAL SENSIBLE 16 Infiltraton Latent Gain Infit. CFM 198 6,871 920 #People 4 17 People Latent Gain 7,791 TOTAL LATENT 40,352 E199 Total Cooling Load /-v This combinatiRn qualifies for a Federal Energy RAMP, Efficiency Tax Credit when placed in service M ILI CERTIFIED,. between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org Certificate of Proddct Ratings AHRI Certified Reference Number: 4597171 Date: 11/20/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25VNA048A**30 Indoor Unit Model Number: FE4AN(B,F)005+Ul Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh)-. 46500 EER Rating (Cooling): 13.00* SEER Rating (Cooling): 17.90* Heating Capacity(Btuh)@ 47 F: 46500 Region IV HSPF Rating (Heating): 11.45* Heating Capacity(Btuh)@ 17 F: 47500 MAZUR, TERESA MC0507 1949 SEMINOLE RD AB, FL 32233 241-3149 1 SYS C/o 11-22-13 Ratings tollowed by an asterisk(*)indicate a voluntary retate of previously published data,unless accompanied with a WAS,which indicates an involuntaiy WM!0 DISCLAIMER resentations,warranties or guarantees as to,and assumes no responsibility for, AHRI does not endorse the product(s)listed on this Certificate and makes no rep the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at,vww.ahridirectoiY org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced:copie&disseminated;entered into a computer database;or otherwise utilized,in any form or mariner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION e verified at "Imp, A' Conditioning,Heating, The information for the model cited on this certificate can 1) click on-Verity certificate"link and enter the AHRI Certified Reference Number and the date on N%11 aim *1 an"d Refrigeration Institu e which the certificate was issued,which is listed above,and the Certificate No..which is listed below. CERTIFICATE NO.: 130294535976480960 @2013 Air-Conditioning,Heating,and Refrigeration Institute