Loading...
1822 Seminole Rd 2013 HVAC CITY OF ATLANTIC BE_ ,�I 800 SEMINOkAD s) ±J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 J,3 Application Number . . . . . 13-00003725 Date 11/25/13 Property Address . . . . . . 1822 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 3 . 5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ STEPP GARY L DONOVAN HEATING & AIR 650 N ST JOHNS DR 315 SIXTH AVENUE SOUTH CAMP HILL PA 17011 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/24/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)247-5845 10B ADDRESS: 182--L Sevn rn o le RJ PERMrF# PROJECT VALUE $ 1512" ARI# 9G 3 REQUIRED Air Handling Equipment Only /Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 3- Heat: Unit Quantity / BTU's Per Unit Z 0 Seer Rating 3 Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace QtyAutomobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name --� ,, p„ W p p Phone Number 71-1 ®I�RS- Qechanical Company J©Noyr�a �� � Office Phone ZY1 3-7K- Fax S :o. Address: 11) v' City .J,p;r BGk State ri Zip3 d ,icense Holder(Print): t+bn� I aY-- State Certification/Registration# 39 -1�- VotariZed Signature of License Holder RICHARD TOMPKINSBefore me S 7— 1 day d 20 " :__ Commission#FF 040399 a: 3 Expires July 29,2017 ao; BondedThruTwyFdnInwan 8W3B5-7919 Signature of Notary Public Job: wri htsoft Project Summary Date: November20,2013 9 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S, Jacksonville Beach, FL32250 Phone.904241-3785 Fax:904-241-3745 Ernail:aaron@donovanac.com Web:www.DonovanAC.00m Proiect Information For: Gary Stepp 1822 Seminole Rd,Atlantic Beach, FL 32233 Notes: Design • • Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 99 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 24 OF Daily range L Relative humidity 50 % Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21368 Btuh Structure 21470 Btuh Ducts 4025 Btuh Ducts 6938 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuhn Equipment load 25393 Btuh Use manufacturer's data 1.04 Rate/swing multiplier Infiltration Equipment sensible load 29543 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2616 Btuh Fireplaces 0 Structure 1912 Btuh Ducts Heating Cooling Central vent (0 cfm) 0 Btuh 4528 Btuh Area (ftz) 1931 1931 Equipment latent load Volume (ft3) 15444 15444 34071 Btuh Air changes/hour 0.38 0.20 Equipment total load Equiv.AVF (cfm) 98 51 Req. total capacity at 0.75 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R41 OA HP Trade 13 SEER N SERIES R41 OA HP Model N4H342CKA* Cond N4H342CKA* AHRI ref no3863589 Coil FEM4P42**A* AHRI ref no3863589 11.0 EER, 13 SEER Efficiency 8 HSPF Efficiency 3EER Btuh Heating input Sensible cooling 10250 Btuh 40000 Btuh 47-F Latent cooling 41000 Btuh Heating output � Temperature nse 27 OF Total cooling 1367 cfm Actual air flow 1367 cfm Actual air flow 0.048 cfm/Btuh Air flow factor 0.054 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure Load sensible heat ratio 0.86 Space thermostat Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Nov-21 13:34:00 + wrightsoft Right-Suite®Universal 8.0 24 RSU05995 Page 1 C\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3.5 ton.rup Calc=MJ8 Front Door faces. E