Loading...
900 Plaza # 34 2013 HVAC CITY OF ATLANTIC BEACH s f 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003800 Date 12/13/13 Property Address . . . . . . 900 PLAZA Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------- Application desc 1 . 5 tons 17 btus ----------------------------------- Owner Contractor -------------- ------------------------ ---------- SEA OATS ACQUISITIONS, LLC GARY MUNSON HTG & A/C 5VC. , INC JEFFREY D. KLOTZ 1215 STEVENS AVE 645 MAYPORT ROAD SUITE 5 ORLANDO FL 32806 ATLANTIC BEACH FL 32233 (407) 859-1494 ----- ------ Permit . . MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee . . . . 97 . 00 0 Issue Date Valuation Expiration Date . . 6/11/14 - - - --- - -- - ---------- - - - - - - ----- -- 2 . 00 Other Fees STATE MECH DCA SURCHARGE STATE MECH DBPR SURCHARGE 2 . 00 _ ________ ----- Fee summary Charged Paid Credited --- Due--- ----- ----------- ------ -- ---------- ---------- - . 00 . Permit Fee Total 97 . 00 9700 . 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 101 . 00 101 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 Jos Anel ss: `L oQ Piazo_ an'�' 3 4 PER>H[rr# 4? PROJECT VALUE $ I �� ARI# )0 3 q 7Z , REQUIRED Air Handling Equipment Only _XAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total. CFM REQUIRED REPLACEMENT AIR CONDITIONING & BEATING SYSTEM: INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 11,15 -- Heat: Unit.Quantity BTU's Per Unit 1:1, 10D Seer Rating_ Duct Systems: Total CFM _�L-y REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of pians) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators _ ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: &aoAman_..AWW: L30,5((P R nA &SX I I Q I S 1E- a Permit teeomos void if work does not ex�mmencc within a six month penod or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be tnte and correct. All provisions of laws grid ordinances goveming this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ! a+5 1Yl i �el �0.t`�f1� Phone Number MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JoH ADDRESS: q M p 1 Q7 Q Ut f 1 t+ PERMIT# Mechanical Company I`� 1 0 t ¢ Office Phohe7'�6 -1 Fa�ac ,('7 Co. Address. (A(E; , City fi('(Agk Statet- Zip�� License Holder(Print): bar,NN Mon State Certification/Registration#CAS P$(Af 337 Notarized Signature of License Holder Before me this day of 2p _ Signature of Notary Public _ " PATRICIA CONNORS c MY COMMI5SION#EE086250 EXPIRES April 20,2015 X01 9131-0163 Fk id*Nott 36rVk*Co r rw now Certificate of Product Ratings AHRI Certified Reference Number: 5039739 Date: 3/25/2013 Product_ Split System: Air-Cooled Condensing Unit,Coil wfth Blower Outdoor Unit Model Number: GSX130181E* Indoor Unit Model Number:AWUF18XX1f3B" Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST,ONE HOUR AIR CONDITIONING AND HEATING,ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity P tY�Btuh): L17200_---- EER Rating (Coaling); 11.00 SEER Rating(Cooling): 00 Ratings fnAnwed by an asterisk()Indicate a votuntary mrate of prevlouvy published data,unless a=npanisd with a 1Nr1S,which indicates an involuntary rerate. DISCLAIMER AHRI does riot endorse the produCUS)IPsted on this CeAiflCaEe arxf makes no rEfXCserrtirt'ornG,wdr*anties a cKit of t e 8e to,and ar+eumea no reaponelWli), r t the productis)Hated on[tele CerttrlCate-AHRI expressly discfatrsss all lia"ffty for damayes of any kind Ikrit1n9 out of flys Use dr perforrrrept p the prodridirr,or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and conftgurapons IWed to HK plrettory at www,,hridirr, tary.nrrt. TERMS AND CONDITIONS al and confidential reference PurPoses• This Csrttfieaits cPr te and contents are mopnetary oducts of AHRL Thio Certificate shall only be used for individual,rn The conterrm of this Certificate may not in whole or in Part,be reprodwtd;Go ct�Pd�Pn dttsretf hNa a com[puteperu®r database;or r�/hcrwiae utilized,in»ny form or manner or by arty means,except for the user's Ir,dNldual,persona CERTIFICATE VERIFICATION verified at ww.ahrldirertvey erg, As "101 Air-Conditioning,Heating, The information for the model dtrd an tuts ClPoflcate can be Certifirate"fink and enter the AHRI ta Click ars'verify I Certified Reference Number and the daon J�� ■0 IL and Refrigeration institute Which Ilse certificate web issued,which(a tieted above,and Certf'�w ft No.,which is listed below, 02013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: i300870818b2590304 Customer Information Unit. 34 Ph One� � � `��� `_- _-____^___-_-,_^ ^~_____`'_'_____--~^ ._-.. __--~_.^. Enoai/-, �� �.- `~'~-___........... ~`~-'_ � 'House Information SHR .75 � - --'__~~-_'--..................~^...'....._-__-..............-'~`^_^-_ ........................ ~_~........................................ ... ...................... � � Number ofne5/dpnts � ......... Cei!ing heigh" � �� '- ----- _- --'-__,-,.~ '--_-_____`.--'-__-__��_�``.�_ -�__.....-__~... `~ VVaUU-VaWe N�v,3|Ue ' _ _ ' -`''................. '........ _''--_-~ , ..,".,.; .,�.,:.'< -„:.;:. qtr,. •;;�.r ,,}: ar..ry .::�{..::�.k� `' �'!.�,,��'.. t.'• Yit:'Fi::J�.1Fr}• ��<+.:�:'C':•:E,::':;'.. Customerr •- "'� r. . .. r ( r• 'ri .JF1-. ,kA': r'A`•�.F'�.”'+1ti�.. h. �'��w4�. N. �Q!'�'�•. ",r:`. ';� ,i+ �`� •Y ��i•f Yl:{:�. 1:� �, 7�Lri., i' ,rt :?t F,K�wi.h"•n�ii^ �,•„�,, ,,........... .....:_,r:—......:....:..:........,.. ...:..:....:.ti........,....r.,,..,.,w......,a:f:._w.:.4';3w,:.. Yf�..I�A;;;:i.:=..�_._ Y:.:::.:�_.,.. . .rca ,;� :!•�r':• ` t_ot_itude, l,angi ade 3033752, -81.7686 ;. . ............:.__._.._. .,..�,.........,. _..._............,.....,....,,..:._..._.,_......,.,,. _.. _.. ......... - rh";✓.Ate...,. x. i- �'�CltlaE? c ua•. o to . , 700 5th..ft. - :+; Narhe, Sea Oats ApartMents: Unit, 34 p110nE: ouselfformation SH R .75 Nl.ir'Y1ber of residents .2 Ce'Hin he�iyht 9 :................. .....................................:._......._.... ............... ....__............... Wall 1.-value # R-value .0.09 1]. Floor U-value I R-va,!4je 0,2 1 5 Ceiling U-value 11-value 0.053 11.9 VVIrldo-v IJ-viak.re 0.5 wind00 SHG 53 N�c'15twl T7 Duct lass IO ... .............:... ............ ......... ........................ '�oolir,q jr filtraction (ACH) U.0 !+t?ti#1;1r;3 1�14�1Cr-�ti(; 1 0"8 iACH) Winter vel-ni.;itdtior. 0 ...................-..............._ ._... .... ... Design Conditions Outdoor Heating Cooling ........................................:...... ................. ...........................................................:..........._....._......... ............__...............�........... .............. Ivry bulb OF} 37. .9-3 , 13I y c a r-I g e M 53 Indoor Heating Cooling Indoor- tempet'atur-e ('F) 70. 75 Dc-siqn. ter-i-irk:r4ture ctifforence( 'f-j 38 18 eating ! . • Area Btuh % of load Wall 2912 1.5 Ftaor 8140 41..9 Ceiffng 1410 7.3 �N:l�t ows 1919 9.9 �c3flttr ttC?n 3265 16.8 System Eff�civricy Lclss 1765 9,1 I oral; 19410 Heating Loads ;.4A10 ©T11/,r Syst wn CfficienCy l ws Floor--ti� ;,' _�Windows Wall Infiltration Coolinq Loads ofImid 1379 8.4 Wall l ' .Y. ................... .....,. ._....... �._... , .. 1595 .Windows '.7 .Y 5623 34.E 5 b1e`l.Ctf�{t; iOt"t 1160•: 7:1 •:Cis. �. ;,e'• •�r. ,.: I..C1..�.'."ll` Itl�llfir��ia 2212 1 -t n '',9 ::�t;. :.;�' �. .,.,f ,`:;'::"'a.;a• a •,�. �'ii,•;• ,..�;;• S.. :,,:. _.. _— ..:.,_.._ _ •. _ __• ........_r T.S,.N::•.y.';��r. •,'Y'+ +�l�.' .�R.:err,?••::.,'}'•',• .. j. JYJL4t1�'Effi41.—rf wv{;7a17{ r:,�'eg1-•���yyy`y�:�:.:' /ii .f;.•=...•. rl','� .•'1':'' '��,�+;;Y+t"( 18T 2 i .......... w-r..-.,.r.n.rrr.r...... ._.w.w..... ._. Internal 2400 14.7 .,� •:i.-��l;;. t;pi,g.},.,,fry%:;:...�. 'r,;':d+'•'.:+ ;:.it i ,'C r..r"-,••µ,.r•. ' '�. .r....r�.-;..�::' .:i..�.�.S .:?!R?,"'•' .,•�' 1,Y.1 ..r,....,•J. .,'":i,^n'Cf.,•.^:' .''�,`�'•S'i ,� %7 ''�S;r''••,1��',:I:.t r''Y:1`sd •P�• �1f;':. rf� M,,.., ....:.....:........y-•:•;Y.Ni,,.,. r ..�'�>.;Y >f;�'r �"' '%t' , �, �;y;,,,. ;.,•".,'ly"�i:^'� .r.:p�:i' ',.�:`;•[:`:qr..;p4;r'M • h •'ik:%:, •:b'%:i':N tY�;''�.'s�s�isr? Latent People load 460 2.8 i "'"s:"r',;f•r,t�v.�',::;;.,nrk::.r:ti:y:>'. •.�A<Y�:..4'.l.Ji.c; y:t,o;;•'''.';,';. ) r.",.l' �;n`�:'tt ''w�'•,' .ti: _._....._. Yyy,• .:r .w...,�...._�;..,-r.•-,+_..........._..—,. -y'yt^!t�..:!'a"J+•+w.v.w_ �_.y �.,,�. ';A,:i'��'}�y7G {f }C;;';I' 6d::::.��t_ '+�1'.�'�.?•;f�7 . .•."S!' ^ .;"� ,• •X'. rr .?.!:•_ ;,r.•:.p'i:t''.1,:FYC`�r. :�l"�t��r•� ;..t„ ... 'I't •.•..,,C:+,: � n _ A:'r'YI.Y�,�,p w�.� .,�:!Y.,. ";til': �.:{'.Vit? •"f, 'fyh�y '�, i1%�"•! 'p'l:f.: h:;.3, �s ;F t.. }."'r...ti:r.'.:`.�:r ��,}d.."y.f^�.•.tr?'rf•= >!C. :'ry i •;�:�`J}ylrr •it ;�Ii�t:.e,�+,�!���TLS�w->yr.," �:'�.r� . r ., ...,;}.y,,.•,.1.: •.?,r-:t :'i.li'..� � ;tii�� ' �. s Citi +..tn;� `E,$, r.). �t� ;�{' !' �..o., .-�;: .:�,`�i;: ,�:�',�n'+1.,;.�.uq,.,.. "' ,.i`,t; �w;`�`x..:s;•� 'ri:,�!Y,.."d°;?�. is e,M, .>iX 'f '"+�" i.7•n,.< �,'#'y «,}.;M<. „ki.-- :�,,, ��� f.�, .�;: •'fir'., �'`•�'�;t:. .f•. ,y._ ...<•a ;:�!` .tr,•r' vj. !" i.. e ,y�, ±. '`7 ,c,lr, j H ;`i�. .<,r,:' :t," .°2'-• '' �•:'r:':;.I f:"� '{(`�: ;�'#•:`•:ry'�'rj,` ;r$"+.�,,:s.kY'°'�''�a1"t;,r..r�Y';i','y�''•:��r'�•:'<..,ff� •;� •' SH: .•�' . ;��. ;�S.r;S �:� pie.�.' f.: '.,',1 .rr �?l.J.., s4: ..S � Yr•�' �a„ "' ,;i.;1.�ir�i. �•,. ppY i,R (�,,,,yr f p i• �`��:..' �x �'.':'•'••}%i: �� '.y.'rt,'..,,!•:r••. 1. �' .k ,aq.d' •.•{,.c YC:,rY,+•,.,:�; •.{r,,,,,i%a }' :i .....r.........,..r.�..._..:::s.:._:,.......r. n.._...:t.:..:..._.:,.....,...-r,:.,,.,•a:f,r....•..f.:rr.c....•_..N.a.:. .:::..':,. . �::t:� ;'J: '^.� •:'. 4 ge A }, +�•�, 2572 .•,Y:.' '1=7>i•.31�i'��-}%�}'�ria�,h ..r?.�;����'�;'� :... i:=tiin:T`r~''��•;;.:; � ta L'i VC� ...�'; •=;Jg'''R].Hof" .'•r^,°�,::K:: `':i`�5�•J••�;,•.r:, `: :.. �••.v Capacity at .75 SMR 1.53 Toni ; Cool i ng Loads t'Sensible People Load - Latent People Load SenslNe Infiltration f' Windows System EfficlencyGX -�� °; f `i - WaM ceiling internal Latentlnflhration AED Graph loam 213M uvm 10M 2pm 3Pm 4pM 5Urn 6ptyl Hourly Loads Average ................ -qutpment sel.ection .-(..bon will be made vsifq the fbilowIng derived Values `j, ....................... Cf iris ( S) 7 .....................4................................... .......... W 7 sq. ft, of ass W) 3S Q ft. .......................................... 93°F ........ ................. ............ ............... Summer Wet Bulb 7-70F ..................... ........................... ............ 75"F .......... Si,immer Design Grains 50% .1 .................................. ...................... Outdoor 32°F ............... ......... . . . ......... ......... ......................... ..................... Winter Indoor 70'P'.F ... ..................... ................ 13,805 Btuh tensible Cooling, ............ ..... 2,572 Btuh Coohng Airflow 627 CFM ................................... Sensible Heating 19,410 Btuh ... ......... ........................................ 252 CFM ..................... All calculabans are ujsea won approved hvac industry St,-sndard5 ard procedures,and comply with all local. it3te and fmie.! 1; Ire Es@rnates,Product provided by Energy Design i� iI co&i.requirements,All computed results Sy:-:ams 3rsa lde.4'Trcie 1215 Stevens Ave Orlando, FL 32806 Gary Munson 407-859-1494 Office 407-894-0746 FAX Fax r To: Fain 1 J fe° 'ZGLItG it f2lA RUN .)-Iylr 3 Rm Cl Urgent ❑ For Review Q Pies"Comment ❑Plemse Reply ❑Please Racycle U-n jz�r