1915 Sea Oats Dr 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003843 Date 12/17/13 Property Address . . . . . . 1915 SEA OATS DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------- Application desc 1 cu 1 ahu ----------------------------------------------- Owner Contractor -------------------- ------------------------ WALLACE, PATRICIA A OCEAN STATE HEAT & AIR, INC. 1702 3RD AVE N 1476 ATLANTIC B . JACKSONVILLE BEACH FL 32250 NEPTUNE BEACH FL 32266 (904) 249-8251 ----------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 107 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/15/14 --------------------- ---------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------- ---------- - Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CTTY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 OB ADDRESS: $ (y PROJECT VALUE MW AIR CONDITIONING & HF ATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Rahn Heat: Unit Quantity_ BTU's Per Unit �`}REQIIIRED Duct Systems: Total CFM ZEPLA.CEM ,NT AIR CONDITIONING & HEATING SYSTEM INSTTAARI#LS•A�T�ON Quantity Tons Per Unit Air Conditioning: Unit � REQU�D U Heat: Unit Quantity 1 BTU's Per Unit SeerngRE UIRED Duct Systems: Total CFM Q +IRE PREVENTION ti (Requires 3 sets of plans) Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires sets of plans) Underground Fire Main (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Regimes 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) „ Fire Suppression Systems Quantity EIRE PLACES NIISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts BTU's Gas Piping-Outlets Boilers Elevators/Esr.,alators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps 'a #Vented Wall Furnaces Refrigerator Condenser B 's #Water Heaters � Solar Collection Systems rA X Tanks(gallons) Wells OTSER: Permit becomes void if work does not commence within a szlc month p��or work is suspended or abandoned for six months.t hereby certify that 1 have visions of laws and ordinances governing this work will be complied with whether specified this application and know the same to be true and correct. All Pro or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the Perfbrmance of construction. Property Owners Name aU Phone✓ Number to �,1 d--4 Office Phone -1_Faxa 1_y Mechanical Company 1 3 2 (1 Lt �.,L�Ct rt 'G �,/G _ City A2L -(36i State 'L Zip _ Co. Address: / License Holder(Print): � ort State Certification/Registration# Notarized Signature of License Ho jol, YVETTE P.MORALES S Orn an a day of NOTARY PUBLIC STATE OF FLORIDA Signature of Notary Public Comm#EE879174 e Expires 3/2/2017 This combination qualifies for a Federal Energy ■ ■l ■ DTM Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org —A certificate of Product Ratims AHRI Certified Reference Number: 5768009 Date: 12/11/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWX8048A1 Indoor Unit Model Number: *AM7AOC48H41 Manufacturer: TRANE Trade/Brand name: XL181 Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 47000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 17.00 Heating Capacity(Btuh) @ 47 F: 46000 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 30000 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS.which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at;^.:ava.ahridirecto y.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means.except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at. a,alt€'idirecto y,org, Air-Conditioning,Heating, click on"Verify certificate"link and enter the AHRI Certified Reference Number and the date on an 11ki and Refrigeration Institute which the certificate was issued.which is listed above,and the Certificate No.,which is listed below. 02013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130312532694270672 Designstar Load Calculation Results are intended for use with Rheem heating and coaling systems �u,Now eTw' r ` . LJtitUde, 1-011 O.Lidti Phone: 904-249-825 Erna3l: S Muse Information 75 Numberg of residents Ceiling height � Mall U-value -value 0,09 11 Fjoor U-value -valued,2 5 Ceiling ti--value R--valUe 0,053 g Window U--value 0,5 Window SFIGF 0.85 lust loss % .g Duct gait) Cooling infilLvaction (ACH) 0,6 Heating infiltration (ACH) 0,8 3 Winter ventilation t urnrner� ventilation x=� iConditions Outdoor Heating Cooling Cr'y bulky ('F) 30 93 Daily range. m Relative humidity 5 0`'y Moisture differ-enck 53 Indoor Heating Cooling hicloor temperature ('F) 70 7 Q!esign ternp.eratur-e diffe,rence,("F) 40 3 Heating ! w ! Area Btuh % of load Wall 5111, 12.8 Floor 7496 18,7 Ceiling 5088 Windows 6880 1 Infiltration11785 29.E jute. i �, ; _? 9, , tl; ; ? Heating Loads 39,096 BTU/h System Efficiency Loss t Infiltration Ceiling a Wall Floor Windows Area B�uh '�/o of load Wall E Jill ..,_. Windows SItlljntljtOtion!�i Latent Infiltration 7240 16 N't 13 internal I - q fI tll I IN l� I � � 3 i ..._. . ...I...... �r.. � .. . ... .� ,.. .,. .�� l 1 460 Latent People Load 4€ £ £ r£jTn- R E a £ �.., I HZ ISI ? Cb I; � * Latent load 7760 SH R OM Capacity at .75 SHR 4,17 Tore Cool i rig Loads Sensible People Load Latent People Load Wall ---Internal System Efficiency G: s Windows Sensible Infiltratit Ceiling Latent Infiltration Ade AED Graph 3i. ... 8ani uam 1-Oar* prn ,E.w, ............ —Hourly Loads —Averaoe i ! selection Glass (E)' 74 sq, ft Glass (S) 24 sq, ft. Glass (N) '' sq� ft, Glass M 122 sqft, Summer 0,,,itdoor 93"T r. mn—,,er Wet Bulb 77"F 75'��" SUrrimer, Design Grains 0% Winter OLft.dOOI 3 ,i' Winter Indoor 70"F Sensible ;r o r4 ater,tCool lr 7,700 th Required g Airflow 1,708 CFM Sensible Fieatkng 39,996 Btuh Required Heating Airflow 510 CFM £31 '.4) G,,(Ad r b`ae e' €€3.C'Y,.';'..Y�tald ,, P tL, E€)E LESts?'�'.`*,and �i � 1:}I';� ��t t{I[:3C stat: and ,cam �,. 'ti(%# ° . '`: :.;C "'v 11;.° .� x. �.:,�.,1 .3a.:: 3r.. .[,"`.1€t..7, dC-j 3s _m" >€y