760 Triton Rd 2013 mech CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003790 Date 12/09/13 Property Address . . . . . . 760 TRITON RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 3 tons 36K btus ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NARKIEWICZ, JOSEPH DONOVAN HEATING & AIR 105 END AVE W 315 SIXTH AVENUE SOUTH LITITZ PA 17543 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/07/14 ------------------------ Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH .--T- 800 Seminole Rd Atlantic Beach, FL 32233 PP Ph(904)247-5826 Fax(904) 247-5845 (OB ADDRESS: �bo 1 2 i-TU N �` PERMIT# PROJECT VALUES S-100 ARI# �? Q PIGS REQUIRED _Air Handling Equipment Only X Air Handling Unit& Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED 2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity f Tons Per Unit 3 j Heat: Unit Quantity I BTU's Per Unit 316 o a Seer Rating Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters _ Solar Collection Systems Tanks(gallons) Wells )THER• ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name san+ayletll, Phone Number 9501-Sy,(--1-7!j-2 dechanical Company o Ht AT• C Alii Office Phone Lyl 37,gr Fax 'Z yl 37Uf :o. Address: (S AvE 5 City �A-r State F/ Zip 3Z2S0 .icense Holder(Print): V v! � �1 , 0"Ov/ State Certification/Registration#—3"i-- AG03q761 tdotarized Signature of License Holder 114 gtin4."Yef RICHARD TOMPKINS. Before me s da rn 29 �3 .: Commission#FF 040399 ��T� na Expires July 29,2017 AR;;,• gabled Thm Troy Fah Meuiance 8043857019 Signature of Notary Public ro ect Summary Job: P �- wrightsoft, 1 Summary Date: 12/6113 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon(Mdonovanac.com Project • • For: Santenelli 760 Triton RD, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17610 Btuh Structure 16031 Btuh Ducts 5848 Btuh Ducts 8534 Btuh Central vent (31 cfm) 997 Btuh Central vent (31 cfm) 688 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24454 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25253 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2067 Btuh Ducts 1891 Btuh Heating Cooling Central vent (31 cfm) 1132 Btuh Area(ft' 1720 1720 Equipment latent load 5090 Btuh Volume?ft') 15480 15480 Air Changes/hour 0.46 0.20 Equipment total load 30343 Btuh Equiv.AVF (cfm) 118 52 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model NXH536 Cond NXH536 ARI ref no. 3670858 Coil FXM4X36 ARI ref no. 3670858 Efficiency 8.5 HSPF Efficiency 15 SEER Heating input Sensible cooling 25253 Btuh Heating output 35896 Btuh @ 47°F Latent cooling 10823 Btuh Temperature rise 27 OF Total cooling 36076 Btuh Actual air flow 1203 cfm Actual air flow 1203 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. „tom +� wrightsoft Right-Suite®Universal 7.1.01 RSU05996 2013-Dec-06 16:02:11 ACO', C:\Users\Sales\Documents\Wrightsoft HVAC\3 Ton.rup Calc=MJ8 Orientation=N Page 1