760 Triton Rd 2013 mech CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003790 Date 12/09/13
Property Address . . . . . . 760 TRITON RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
3 tons 36K btus
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
NARKIEWICZ, JOSEPH DONOVAN HEATING & AIR
105 END AVE W 315 SIXTH AVENUE SOUTH
LITITZ PA 17543 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 6/07/14
------------------------
Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
.--T- 800 Seminole Rd Atlantic Beach, FL 32233
PP Ph(904)247-5826 Fax(904) 247-5845
(OB ADDRESS:
�bo 1 2 i-TU N �` PERMIT#
PROJECT VALUES S-100 ARI# �? Q PIGS REQUIRED
_Air Handling Equipment Only X Air Handling Unit& Condenser Condenser Only
JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity f Tons Per Unit 3 j
Heat: Unit Quantity I BTU's Per Unit 316 o a Seer Rating
Duct Systems: Total CFM REQUIRED
IRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
+IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters _ Solar Collection Systems
Tanks(gallons)
Wells
)THER•
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners Name san+ayletll, Phone Number 9501-Sy,(--1-7!j-2
dechanical Company o Ht AT• C Alii Office Phone Lyl 37,gr Fax 'Z yl 37Uf
:o. Address: (S AvE 5 City �A-r State F/ Zip 3Z2S0
.icense Holder(Print): V v! � �1 , 0"Ov/ State Certification/Registration#—3"i-- AG03q761
tdotarized Signature of License Holder 114
gtin4."Yef RICHARD TOMPKINS. Before me s da rn 29 �3
.: Commission#FF 040399 ��T�
na Expires July 29,2017
AR;;,• gabled Thm Troy Fah Meuiance 8043857019 Signature of Notary Public
ro ect Summary Job:
P
�- wrightsoft, 1 Summary Date: 12/6113
Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon(Mdonovanac.com
Project • •
For: Santenelli
760 Triton RD, Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 68 OF Inside db 75 OF
Design TD 29 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17610 Btuh Structure 16031 Btuh
Ducts 5848 Btuh Ducts 8534 Btuh
Central vent (31 cfm) 997 Btuh Central vent (31 cfm) 688 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24454 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 25253 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 2067 Btuh
Ducts 1891 Btuh
Heating Cooling Central vent (31 cfm) 1132 Btuh
Area(ft' 1720 1720 Equipment latent load 5090 Btuh
Volume?ft') 15480 15480
Air Changes/hour 0.46 0.20 Equipment total load 30343 Btuh
Equiv.AVF (cfm) 118 52 Req. total capacity at 0.70 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade Trade
Model NXH536 Cond NXH536
ARI ref no. 3670858 Coil FXM4X36
ARI ref no. 3670858
Efficiency 8.5 HSPF Efficiency 15 SEER
Heating input Sensible cooling 25253 Btuh
Heating output 35896 Btuh @ 47°F Latent cooling 10823 Btuh
Temperature rise 27 OF Total cooling 36076 Btuh
Actual air flow 1203 cfm Actual air flow 1203 cfm
Air flow factor 0.051 cfm/Btuh Air flow factor 0.049 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.83
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
„tom +� wrightsoft Right-Suite®Universal 7.1.01 RSU05996 2013-Dec-06 16:02:11
ACO', C:\Users\Sales\Documents\Wrightsoft HVAC\3 Ton.rup Calc=MJ8 Orientation=N Page 1