Loading...
1915 Oak Cir 2013 HVAC �`S ���••L`J•�Jug CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD s) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003801 Date 12/10/13 Property Address . . . . . . 1915 OAK CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------------- Application desc 2 tons, 24K btus ------------------------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- LEAS, MICHAEL R SERVICE EXPERTS 1915 OAK CIRCLE 8475 WESTERN WAY STE 100 ATLANTIC BEACH FL 322334506 JACKSONVILLE FL 32256 (904) 271-2182 --------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . 101 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/08/14 ------------------------------------------------------------------ Other Fees . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ----------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- Permit Fee Total 101 . 00 101 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 105 . 00 105 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION 0 CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 JOB ADDRESS: PERMIT# o, PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INARTALLATIO�N�D� Air Conditioning: Unit Quantity Tons Per Unit REQUI D Heat: Unit Quantity / BTU's Per Unit Seer Rating . �D Duct Systems: Total CFM R,tQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 6-14 l L Lem 5 Phone Number c 3�— Mechanical Company CNI 1( •cynzf�S V/CP ice Phone t2 W-21 ax Co. Address: Sy75 tJts4e�t-n tau, Ju I �r_- 1Cb City_)lncy<SMUl1 t StateF) Zip License Holder(Print): /' _ State Certification/Registration#�iI�J�/ �1A J Notarized Signature of License Holder 7Ad___= Sworn and sub ribed before me this day of o 20 CAROL A.BRESSLER mature of Notary Public . Notary Public-state of Florida a. My Comm.Expires Jul 5,2014 Commission # EE 36112 This combination qualifies for a Federal Energy A Ulm Efficiency Tax Credit when placed in service iqm Nual CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5186808 Date: 12/9/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 14HPX-024-230-18 Indoor Unit Model Number: CBX27UH-024-230'+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: 14HPX SERIES Series name: Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 25200 EER Rating (Cooling): 13.70 SEER Rating (Cooling): 16.20 Heating Capacity(Btuh) @ 47 F: 21800 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 13700 FootNote 11 -The AHRI 210/240 certified EER ratings are calculated under the same methodology as the EER ratings at T1 conditions of ISO 5151:2010 and ISO 13253:2011. 'Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the products)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION LA10' The information for the model cited on this certificate can be verified at www.ahridirectory.urg, it Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. 00 -' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130310875514534509 Customer • . • Street Address 1915 Oak cir, Neptune beach, FL 32266 Latitude, Longitude 30.33750, -81.7686° ..............._ ......... ... ._._._..._........._.........11....... ......_......................... . ..................... .. . ..... ..... ......... House Square Footage: 900 sq. ft, .......__._........................._........._-........................_............................._........................................................................................................................................................................ ................. Name: Gale Leas .......... ............ ._..... ........................................_..._.... . ......... ........... . ............ ...._._.. .......... ............ 1111 Phone: 904-241-2832 .......... ... ...... ._............................... ..........................................._ .............. ............ ._.............. .... Email: Wayr)e.furr@serviceexperts,com ..........._ . ........ . ................. ..........._... .... .......... . ...... ..... ........... ................. ... ........ 'iHouse Information SHR •75 .--.........__.............................._...._._._.............._.................................................._........................_..........................................................._........_..-........._..._.........._.................................._................... Number of residents 4 .... .. ....... . ............................................................._.... ........... ......... ._ ......---- ........................ ................... ..................._ Ceiling height 9 ..............................I ......... . . .. ... ..__.... ................ .. .... _..... _... .......... ............ _ Wall U-value R-value 0.09 1 11 . ........... ..... ........................... ............................................................................... .... ........ . ..._....... . .......... ...... ......................................._ Floor U-value ( R-value 0.2 15 Ceiling U-value I R-value 0.053 1 19 ......... ........... ...._ .... ._. ..... .. ....... ..... .................._ Window U-value 1 ................................. ....._ _..................................._._......................_............................... Window SHGF 0.85 ......................................_...........................................-........................................................................._ ............................................ .................................................................._._................... ....._ Moisture grains 58 ...............---........................................_........................................_......................................................................................................................................_.....................................................I-.,.......................................... .... Duct loss % 10 .............................. . .. ........................................ , Duct gain % 10 ............... ............ ..................................................... Cooling infiltraction (ACH) 0.6 _ .. . .. ..... ....... ..... ............ ....._._._. Heating infiltration (ACH) 0.8 _._..... ...... ....................................... .................................---........................................ ..........._...._......................................................... ._. . Winter ventilation 0 . ...... ........ . ..... Summer ventilation 0 iDesiqn Conditions Outdoor Heating Cooling ..................................................._........................................................................................................_............................................................._.........._........................................................... Dry bulb (°F) 32 95 ......................._ .._...... ....._........... Daily range M ....... .................. ........_....................................................... ...._... ............. . ......................._ . .. ...... . .......... Relative humidity 50% ......... . ............ . ....... ...... .............. ........ ..... .. _............._......._.._..... ...__. ........... . __ _.... Moisture difference 58 ....._.... .. . ..__ . ...... _ ..._..._ .. ......... .... Indoor Heating Cooling ..................................... .............. ..... ....... ......_ ... Indoor temperature (°F) 70 75 ................... .. ._........ ....._. ........... .... _ Design temperature differenceff) 38 20 ........................................................................................................................................................................................................................_.........................................__.................................._ I Heating Loads Area Btuh % of load .........................................................._..._........................... ........._.........._.................. Wall 3427 15.2 ..._....... Floor 8140 36 .......... _........................................................... . ............. Ceiling 1813 8 ......................................................................................................:....._1111. 1111................_.............._.................. ...... Windows 2964 13.1 .........................................................................................................._...................................._._.................................. .. Infiltration 4198 18.6 ............................................._..............................._.............................1..1.1..1. System Efficiency Loss 2054 9.1 .............................................................................................._...................................._........................................1111.. Total: 22596 ..............................................................I--.._...................................._..............11..........1................ 1. Heating Loads 22,596 BTU/hr r Ceiling I, / System Efficiency Loss Floor �s Windows i i if Wall Infiltration J coolinq Loads -AreaBtuh % of load .................................................... Wall 1804 9.5 ................__......................................... .................................... ............I - ............. Ceiling 2147 11.3 ............... ............. .......................................---............................. Windows 4816 25.4 .................................................................................... ......................................................... Sensible Infiltration 1657 8.7 ................................................-...................................................................... ....................I.._._........_..._._ Latent Infiltration 2971 15.7 ................ System Efficiency Gain 1339 7.1 Internal 2400 12.6 -1.11............... ................................................................................................................ Sensible People Load 920 4.8 ............... ........... ........... Latent People Load 920 4.8 Total: 18973 .......... Sensible load 15082 ................ .......................... Latent load 3891 ............. ........................ ........................ ......................... SHR 0.79 ............ .. ...................-.1.1.1'.........-.......... Capacity at .75 SHR 1.68 Tons .............................................................................................................................................................. Cooling Loads 18,973 BTU/hr Sensible People Load Latent People Load Windows System Efficiency Gain Sensible Infiltratio Wall tent Infiltration Internal Ceiling ............ ........... -------— ---------- ............ Adequate Exposure AED Graph 7500 5000 a M 0 J 2500 0 8am 9am loam 11am 12pm fpm 2pm 3pm 4pm 5pm 6pm 7pm 8pm C— Hourly Loads —Average • • ent selection System equipment selection will be made using the following derived values. Glass (SW) 30 sq. ft. ._................_................._.........................__._.._......._.................................................................._..............._._... . ............................._..............................._..._......._.__._......_..............__._..................... . Glass (NW) 24 sq. ft. ................... ............ Glass (SE) sq. ft. ........ ... .... . .. _......... ....... ..... . ....... ....................... Glass (NE) 24 sq. ft. Summer Outdoor 95°F ................................................................................................................................................................................................................................._......... ...... ...... _ Summer Wet Bulb 77°F Summer Indoor 75°F __ ................................._.................... Summer Design Grains 50% ......................... Winter Outdoor 320F ..........._.....................__._........................................................................................................................................................................._..........................._............................................. Winter Indoor 70OF ....................................... .......... .......... .................................................... ... ..... Sensible Cooling 15,082 Btuh ......................_............. ......_.... .................................................................................................._.......__............................................................................................... Latent Cooling 3,891 Btuh ........ .. ........ .......... Required Cooling Airflow 686 CFM ......................................_ ......................_................_ Sensible Heating 22,596 Btuh ._....................................._.............................................................................................._................_......................................................_........._........................................................ Required Heating Airflow 293 CFM ..........................................................................................................................................................................................................................._..................................................................... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree