Loading...
544 Ocean Blvd 2013 HVAC �S r�`11jv� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �JF3 Application Number . . . . . 13-00003861 Date 12/20/13 Property Address . . . . . . 544 OCEAN BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- BISHOP JOHN B ET AL HUXHAM HEATING & AIR 544 OCEAN BLVD 2101 FLORIDA BLVD. ATLANTIC BEACH FL 322335340 NEPTUNE BEACH FL 32266 (904) 246-6721 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/18/14 ------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 u Ph (904) 247-51l826 Fax (904) 247-5845 JOB ADDRESS: S�� ( ©C�,,U�.. (61,J) PERMIT# PROJECT VALUE $ 3(c50-v ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit '2.S Heat: Unit Quantity ! BTU's Per Unit 30,t000 Seer Rating 1-3 Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.1 hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name��//!J�S po- //// Phone Number Mechanical Company /It I�/77"e,f �`� Z/^-C_ Office Phone Fax Co. Address: q 33 7^ L City State R-Zip.39d� License Holder(Print): 4 State Certification/Registration#046os?r s Notarized Signature of License Hold efor e this day of 20 Ignature of Notary Public RODRIGUEZ Project Summary Date: Dec 19,2013 energy consulting Entire House By: ERIN RODRIGUEZ Project Information For: BISHOP 544 OCEAN BLVD,ATLANTIC BEACH, FL 32233 Notes: HUXHAM -CHANGE OUT Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13356 Btuh Structure 15474 Btuh Ducts 3888 Btuh Ducts 5351 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17244 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 20201 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1364 Btuh Ducts 1318 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1085 1085 Equipment latent load 2682 Btuh Volume(ft') 8680 8680 Air changes/hour 0.45 0.23 Equipment total load 22883 Btuh Equiv.AVF (cfm) 65 33 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade Trade Model GSZ13030 Cond GSZ13030 AHRI ref 5936460 Coil ARUF30 AH R I ref 5936460 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 20020 Btuh Heating output 27000 Btuh @ 47'F Latent cooling 8580 Btuh Temperature rise 26 'F Total cooling 28600 Btuh Actual air flow 953 cfm Actual air flow 953 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� Wrl htsOft 2013-Deo-2001:06:26 A-7, g Right-Suite®Universal 2012 12.1.08 RSU01508 Page 1 ts\wrightsoftHVAOTemplateWUXHAM-BISHOP.rup Calc=MJ8 Front Door faces:E