Loading...
333 Ocean Blvd 2013 HVAC CITY OF ATLANTIC BEACH 1 J 800 SEMINOLE ROAD s) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ��xs JJ���► Application Number . . . . . 13-00003792 Date 12/09/13 Property Address . . . . . . 333 OCEAN BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 -------------------------------- Application desc 3 ton 36K btus -------------------------------- Owner Contractor KANE BERNARD HUXHAM HEATING & AIR 333 OCEAN BLVD 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUN246E CH FL 32266 ----- ---- Permit MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee . . . . 99 . 00 0 Issue Date Valuation Expiration Date 6/07/14 -------- OSTATE MECH DCA SURCHARGE 2 . 0 Other Fees STATE MECH DBPR SURCHARGE 2 . 00 ------------------______ ---- Fee summary Charged Paid Credited _ _ --------- ----- ---------- ---------- - . 00 Permit Fee Total 99 . 00 99 . 00 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MCHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JoB ADDRESS: y3 C e,4� v PERMIT# ,v PROJECT VALUE S SY NEI V AIR CONDITIONING& HEATING SYSTEM INSTALLATION kir eat: UConditionin • Unit Quantity Tons Per Unit mt Quantity BTU's Per Unit Seer RatingREQUIBBD ct systems: Total CFM _---- RE LACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION� f— Tons Per Unit ?' REQ Conditioning Unit QuantitUnit 1 BTU's Per Unit ' " , Seel Rarin�RREQUMED eat: ct Systems: Total CFM F PREVENTION (Requires 3 sets of plans) ire Sprinkler System Qom' (Requires 3 sets of plans) ire Standpipe v (Requires 3 sets of plans) nderground Fire Main (Requires 3 sets of plans) ire Hose Cabinets Quantity (Requires 3 sets of plans) ommercial Hoods Qom' (Requires 3 sets of plans) ire Suppression Systems Quantity MIscELLANEous: PLACES Automobile Lis re£abricated Fireplace Qty___---- Boilers BTU's Piping Outlets Elevatolm/Escabdors AL OTHER GAS PIPING Heat Exchanger of Outlets PUMPS ___— RefriBerator condenser Vented wall Furnaces BTU's Solar Collection Systems Water Heaters — Tanks(gallons) Wells O R• for six m ndm I�+certify that I have read P Comes void if wozk does not oo wtthm a six month peRod ar work is ar vm&will be c �why specified _ All 10 of laws aid o 80 or the Mfor�of on- this •ce ion�gnow the same y to �of any ot1�slate or local lawregalahacm*uctimn or not The permit does mt> Phone Number Prop Owners Name 1 `` rice Phone �' 1 Fax `�Lr x377 Mee cal company 'I. 11�a, �7 P , 1• Ap 3 Co. cress: `l _�ovf�— city on/Regisuation#State cafi C o57g�5 Lice Holder(Peat): �vmoo_rri andsubscribed before this day of SignsWre of Notary Public MIRNA AOSHADE•DOWNING ?r* c Notary Public•State of Florida My comm.Expires Oct 21,2016 %1�oFd; commission#� EE 845406 Job: 12813 Project Summary Date: Dec 08,2013 III �I!�I Entire House By: ERIN RODRIGUEZ Project Information For: KANE 333 OCEAN BLVD, ATLANTIC BEACH, FL 32233 Notes: HUXHAM-CHANGE OUT Desiqn Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16135 Btuh Structure 17365 Btuh Ducts 4988 Btuh Ducts 7071 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21123 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 23703 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1811 Btuh Fireplaces 0 Ductsure 1740 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1441 1441 Equipment latent load 3551 Btuh Volume (ft3) 11527 11527 Air changes/hour 0.45 0.23 Equipment total load 27253 Btuh Equiv.AVF(cfm) 86 44 Req.total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade PREFERRED SERIES PURON HP Trade PREFERRED SERIES PURON HP Model 225BNA036****A Cond 225BNA036 A AHRI ref 3677446 Coil FV4CN(B,F)003 AHRI ref 3677446 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 23660 Btuh 33600 Btuh 10140 Btuh 47°F Latent cooling Heating output @ Total cooling 33800 Btuh Temperature rise 27 °F 1127 cfm Actual air flow 1127 cfm Actual air flow 0.046 cfm/Btuh Air flow factor 0.053 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0 87 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Dec-08 23.11 03 wrright30 t° Right-Suite®Universal 2012 12.1.08 RSU01508 Page 1 ents\Wrightsoft HVAC\Template\HUXHAM-KANE.rup Calc=MA Front Door faces: W