Loading...
1955 Beachside Ct 2013 HVAC elf r f�� 'i CITY OF ATLANTIC BEAM. 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 v INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003883 Date 12/30/13 Property Address . . . . . . 1955 BEACHSIDE CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor JURASIC MATEO AND MARGAUX SERVICE EXPERTS 1955 BEACHSIDE CT 8475 WESTERN WAY STE 100 ATLANTIC BEACH FL 322335955 JACKSONVILLE FL 32256 (904) 271-2182 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/28/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 103 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904)247-5845 Jos ADDRESS: -('/f- SJ/.40 P PEWMT# PROJECT VALUE $ (� NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# Air Conditioning: Unit Quantity Tons Per Unit REQUI D Heat: Unit Quantity / BTU's Per Unites Seer Rating Duct Systems: Total CFM REMIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name / j 14A S-Z C- Phone Number 6 /41- i� (F�� Mechanical Company 1( �(le-�T�S Office Phone Co. Address: 8y75 W 51e�f-f) tJOUA Sol lr-- 100 CityJQc�nyilt StateFJ Zip License Holder(Print): e� A IU91-) State Certification/Registration#elk-- 1-91344 Notarized Signature of License Holder —7--3:2< ;?L Sworn ands scribed before me this U_ ay of�Pre�/ �20 3 •ms:µy i nature of Notary Public q CAROL BRE5SL ER a Myth Y�Publrc State of F o►Ida .= nop.• m Expires Jul Commission 5.2014 FF 36172 Des ig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems Trte New Delo* ------------ 'Customer Information Street Address 1955 Beachside Ct, Atlantic Beach, FL 32233 -1-1-1-1-1--.1-1-1........ 1111.. .........................._..__ ..................... ......... .......... ......... ....1111................................. ................... ............ Latitude, Longitude 30.3375°, -81.76860 ._............................. ........... ........... _11__11 .............. .._....... ...................._................ House Square Footage: 1700 sq. ft. __. ..................._.............. . .11.1....1... 1....11.1. . .... 1.1.11......................................._... Name: Mateo Jurasic __._.. __........... _ ........................................ . _--- ...1...11.1............................ _ ._ ........................ ...................... ......... ............ . ....._............... Phone: 904-614-6811 ........ . ..... _1111 .. ................... ......... ............... Email: Cjristopher.Craft@serviceexperts.com 1.1111._ .................................I..............._.................._............_..................................._. ............................_............_.............................................__.._..... .._.....................................I........... House • . • SHR .75 _...... ............ Number of residents 2 ......111.1. .. . .............. .. _1111 ...11..11 ............. Ceiling height 9 ................. ._...................__. ......_._._........... . _ ...... ..... _..._ Wall U-value R-value 0.09 1 11 Floor U-value ( R-value 0.2 5 __1111 Ceiling U-value R-value 0.0333 30 Window U-value 0.5 .1....111.. ... .. . 1111_.. __ ._ ........ .......__ Window SHGF 0.85 Moisture grains 53 Duct loss % 10 Duct gain % 10 ... . ............ . _.__ .........._......................................1._...1...........11 . 111.....1........ Cooling infiltraction (ACH) 0.6 .....1111 _ . ._._.................. Heating infiltration (ACH) 0.8 _... .... . ................... ............... ___ ............... ............ Winter ventilation 0 _.................. . Summer ventilation 0 ...................._ ..........................................._.. ............. Design Conditions Outdoor Heating Cooling ........... ................. ................... .......... .......... .............. ........................................... Dry bulb (OF) 32 92 I. ...........I 1 1.1- .............. .......... .......... .................. ................. Daily range M ............. -.......... .......... ............. ............... ...... Relative humidity 50% Moisture difference 53 ................ ............ Indoor -Heating Cooling Indoor temperature (OF) 70 75 ..............I'll'' ...............- -............... ............. ........... .............-1--.....",.......... Design temperature difference(OF) 38 17 ....................... ........................................... ..........-................................I..,............. ..........................................-.-.......... .......-1.1................ �Heating...Loads Area Btuh % of load .............-L ......- .............I.-I....1-1-1 Wall 4177 10.7 11.11 1.11-11-1................... ................... .....................................................-.- ---................. Floor 16279 41.6 ........... ................-1-11...............1....".. 1.......I I I..............I.......... Ceiling 2151 5.5 ............................_I....._...................................-,.............................................................. Windows 4997 12.8 --................-.......... ................................................................-- ........................ Infiltration 7930 20.3 .................. I.........-.................................................. ................................................- System Efficiency Loss 3553 9.1 -............ .................. ......................................................................-.-........... ............. Total: 39088 ............................... ..................................................................... ........................ Heating Loads 39,088 BTU/hr Ceiling System Efficiency Loss Floor Wall Windows Infiltration V Area_. Btuh % of load a Wall 1869 5.7 Ceiling 2378 7.3 ......... _ ._.. . Windows 14555 44.7 _. Sensible Infiltration 2661 8. Latent Infiltration 5128 15.7 System Efficiency Gain 2659 8.2 Internal 2400 7.4 Sensible People Load 460 1.4 Latent People Load 460 1.4 Tot1.al: 325 70 ... ....... Sensible load 26981 Latent load 5588 ................._........................................_...................................._...._............._................................_.......... SHR 0.83 . ........................ . ._. Capacity at .75 SHR 3.00 Tons ........................................_..................................................................._.._...... .. .................... Cooling Cooling Loads 32,570 BTU/hr r Sensible People Load Latent People Load Wall Ceiling �—Internal Windows —� System Efficiency Sensible Infiltration Latent Infiltration �Adequate ExposureDiversity + AED Graph 20000 15000 - v 0 10000 ---- J 5000 0 8am 9am loam llam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm — Hourly Loads —Average �Equipment selection System equipment selection will be made using the following derived values. Glass (E) 123 sq. ft. Glass (S) 17 sq. ft. Glass (N) 17 sq. ft. _ .1.1.11... _......._ _ . ......... .1.11 .1.................I ............ .......... ... ....._. Glass (W) 106 sq. ft. Summer Outdoor 92°F 11..11 .... 11.. . .1.111 .._._..... .......... ... ..__1111......._ .. _...._._ Summer Wet Bulb 77°F .............. ........... Summer Indoor 75°F -.1 1.11 1__.__.._. ......... ....1.1.. 11. ... ._............._..._.. __ ............. Summer Design Grains 50% ..... ............ .. .......... Winter Outdoor 32°F ..... .......... ._............._........ ..... ... ....._....._.. Winter Indoor 70°F Sensible Cooling 26,981 Btuh Latent Cooling 5,588 Btuh -_ ............. . 1111................................ ...1111 .......... .._.. . .. Required Cooling Airflow 1,226 CFM .1..111... ......................................... .._ Sensible Heating 39,088 Btuh ..... �.11.1 .... ..... _ _.. ........1.1.1.1... Required Heating Airflow 508 CFM 1.1.11.11.. .. .........1111... ....................................... ........ ....... ........ . .. ....................11.........._............................. ............ .................................... .1.11_ All calculations are based upon approved 11vac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 5187082 Date: 12/30/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 14HPX-036-230-18 Indoor Unit Model Number: CBX27UH-036-230"+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: 14HPX SERIES Series name: Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 34800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.20 Heating Capacity(Btuh) @ 47 F: 32800 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 20400 FootNote 11 -The AHRI 210/240 certified EER ratings are calculated under the same methodology as the EER ratings at T1 conditions of ISO 5151:2010 and ISO 13253:2011. `Ratings followed by an asterisk(`)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.,ihridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��' The information for the model cited on this certificate can be verified at v,iww.ahridirectory.org' Air-Conditioning,Heating, click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on A. .■ -' which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. and Refrigeration Institute ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130328981172427040