Loading...
133 Beach Ave 2013 HVAC CITY OF ATLANTIC BEACH AIN- 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 13-00003891 Date 1/02/14 Application Number � 133 BEACH AVE Property Address . . . • • Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------- ----------- ----------------------------------------- Application desc 1 CU 1 AHU -------------------------------- Owner Contractor ---------- --------------------__ -------------- KOGER NANCY T TRUST DONOVAN HEATING & AIR 315 SIXTH AVENUE SOUTH 133 BEACH AVE ILL ATLANTIC BEACH FL 322335280 (904)0241-3EgBEACH FL 32250 ----------------- -- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . - Plan Check Fee . 00 Permit Fee . . . . 99 . 00 0 Issue Date Valuation Expiration Date . . 7/01/14 - Other -------------- ---------------------- Other Fees STATE MECH DCA SURCHARGE 2 . 0 STATE MECH DBPR SURCHARGE 2 . 00 ----------------_____ ----- Fee summary Charged Paid Credited _______ 99 . 00 ------- . 00 . 00 Permit Fee Total 99 . 00 00 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION owmww CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 # FOB ADDRESS: 33 �F/aC ki � PERIvn'r PROJECT VALUE (7.22- _REQUIRED _Air Handling Equipment Only X0 Air Handling Unit& Condenser Condenser Only qEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin REQUIRED Duct Systems: Total CFM ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity 1 BTU's Per Unit 3Lu Seer Rating IS REQUIRED Duct Systems: Total CFM +IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Pumps # neWall Furnaces Refrigerator rator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name �la+w- 1/11 Q o Phone Number dechanical Company �JDYI®yov� ����T r Alii Office Phone ZW-37k5 Fax 7 31 qr :o. Address:_ 3ls Avg S City �i�x dal^ State El Zip 322SO .icense Holder(Print): W+ ( (i Q 'J a��e�� State Certification/Registration# cx)3 57 L ,lotarized Signature of License Holder= OAM, M�e''•s RICHARD TOMPKINS Before me this Z day o 20—�----- = : :.: "i Commission#FF 040399 s Expires July 29,2017 Signature of Notary Public dpkr", Bonded Tin Troy Fen Invmm SOOM-7019 ` Job: • Pro ect Summary Date: January 2,2013 - - wrightsoft' En re House er. Aaron Thacker Donovan Heat&Air 315 6th Ave S,.&cksorMlle Beach,FL32250 Phone:904-241-3785 Fax:9042413745 Email.aaron@donrnenac.com Web:~-DonoranAC.com For: Pam Moore 133 Beach Ave,Atlantic Beach, FL 32233 Notes: Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 95 °F Outside db 39 OF OF Inside db 70 °F Design � 20 F Desi TD ng Design 31 F p�y�rangge 50 Relative humidity 53 Ab Moisture difference gr/lb Summary Sensible Cooling Equipment Load Sizing 26705 Btuh Structure 24600 Btuh h Structure 4717 Btuh Ducts Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping 31422 Btuh Use manufacturer's data n Equipment load Rate/swing multippl�ier Infiltration Equipment sensible load 25M Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1154 Btuh Fireplaces 0 Structure 1961 Btuh 0 Btuh ung Coolin Central vent(0 cfm) 3115 Btuh Area(ft2) 1040 $034 Equipment la{ent load Volume({t3) 8320 0.420 i ment total load 28551 Btuh Air chan /hour 652 0.23 EquP(cfm) 32 Req. total capacity at 0.70 SHR 3.0 ton Equiv.AVF Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 15 PURON SINGLE STAGE ... TradeCOMFCond ORT`�30URON SINGLE STAGE ... Model 25HCC536A"'30 Coil FV4BN(B,F)003 AHRI ref no3676222 AHRI ref no3676222 HSPF Efficiency 12.5 EER. 15 SEER Efficiency 8.5 Sensible cooling 23660 Btuh Heating input 34200 Btuh @ 47°F Latent cooling 10140 Btuh Heating output °F Total cooling 33800 Btuh 28 Temperature rise cfm Actual air flow 1127 cfm 1127 Actual air flow 1127 cfmlBtuh Air flow factor 0.044 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0.89 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 201"n-02 13:43:34 -P`i- ft Page 1 wrightso Right-suites Universal 8.0.24 RSU05995 ACO', C:\Users\Owner\Documents\Wnghtsoft FNAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces: W