74 S Saratoga Cir 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
j � ATLANTIC BEACH, FL 32233
` INSPECTION PHONE LINE 247-5814
Application Number . . . 14-00000019 Date 1/09/14
Property Address . . . . . . 74 FORRESTAL CIR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------
Application desc
1 cu 1 ahu
--------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
MARTIN LILLIAN DONOVAN HEATING & AIR
74 FORRESTAL CIRCLE 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
-------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . . 00
Permit Fee . . . . 95 . 00 Plan Check Fee .
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 7/08/14
---------------------
---------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax(904) 247-5845
'�� �- I PERMIT#
o
10E ADDRESS: r
PROJECT VALUE S �3� ARI# 31 a 55--REQ UIRED
_Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
STEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit _________
Seer Rating
BTU's Per Unit
Heat: Unit Quantity REQUIRED
Duct Systems: Total CFM
2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity t Tons Per Unit -J. ,_5 13. 2-
BTU's Per Unit 30,reap_ Seer Rann8
Heat: Unit Quantity�._ REQUIRED
Duct Systems: Total CFM
IRE PREVENTION a uires 3 sets of plans)
Fire Sprinkler System Quantity (Requires
3 sets of plans)
Fire Standpipe Quantity (Requires3 sets of plans)
Underground Fire Main Value { q
{Requires 3 sets of plans)
Fire Hose Cabinets Quantity
Commercial Hoods Quantity _ (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Droperty Owners Name L I < <1 4 r a ''`� Phone Number Z` l 'Q t S
Zyl-37 0 37y�
Mechanical Company �On 6 J a� ���' F �' Office Phone Fax Z
'3l5 �o op�1 5 City State Fl Zip32Z s
:o. Address: U
.icense Holder(Print):
G a State Certification/Registration# �'�'�b
Jotarized Signature of License Holder
1Y•" RICHARD TOMPKINS Before me this _day of 20__-L-
r .5 Commission#FF 040399
"�,•rTo, Expires July 29,zo» Signature of Notary Public
-f,}� -,—d Th.Troy Fain Insmix 800.385-7019
Project Summary Job:
wri htsoft Date: January2,2013
9 Entire House By: Aaron Thacker
Donovan Heat&Air
3156th Ave S. Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project
_ • . f
For: Lillian Martin
74 Forrestal Cir S,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 70 OF Inside db 75 OF
Design TD 31 OF Design TD 20 OF
Daily range L
Relative humidity 50
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11282 Btuh Structure 15262 Btuh
Ducts 3308 Btuh Ducts 4672 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 14590 Btuh Use manufacturer's data 1 00n
Rate/swing multiplier
Infiltration Equipment sensible load 19934 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average Structure 2253 Btuh
Fireplaces Ducts 997 Btuh
HeatingCoolin Central vent(0 cfm) 0 Btuh
Area (ft2) 132132 Equipment latent load 3250 Btuh
Volume (ft') 11916 11916
Air changesthour 0.45 0.23 Equipment total load 23184 on
Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R41 OA HP
Model N4H330A(G)KB* Cond N4H330A(G)KB*
AHRI ref no1473903 Coil FEA4X3b****
AHRI ref noS716055
Efficiency -7,7HSPF Efficiency 10.1 EER, 13 SEER
Heating input Sensible cooling 20160 Btuh
Heating output 39WO Btuh @ 47°F Latent cooling 8640 Stuh
tuh
Temperature rise 32 OF Total cooling 28800 960 cfm
Actual air flow 960 cfm Actual air flow
0.048 cfm/Btuh
Air flow factor 0.066 cfm/Btuh Air flow factor
0 in H2O Static pressure 0 in H2O
Static pressure
Space thermostat Load sensible heat ratio 0.86
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
I 2014-Jon-02 14:04:37
-f J+ wrightsoft Right-Suite®universal 8 0.24 RSU05995 Page 1
G\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc=MJ8 Front Door faces: E