Loading...
74 S Saratoga Cir 2014 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j � ATLANTIC BEACH, FL 32233 ` INSPECTION PHONE LINE 247-5814 Application Number . . . 14-00000019 Date 1/09/14 Property Address . . . . . . 74 FORRESTAL CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------- Application desc 1 cu 1 ahu -------------------------------------------------- Owner Contractor - ------------------------ ----------------------- MARTIN LILLIAN DONOVAN HEATING & AIR 74 FORRESTAL CIRCLE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 95 . 00 Plan Check Fee . Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/08/14 --------------------- --------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 '�� �- I PERMIT# o 10E ADDRESS: r PROJECT VALUE S �3� ARI# 31 a 55--REQ UIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only STEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit _________ Seer Rating BTU's Per Unit Heat: Unit Quantity REQUIRED Duct Systems: Total CFM 2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity t Tons Per Unit -J. ,_5 13. 2- BTU's Per Unit 30,reap_ Seer Rann8 Heat: Unit Quantity�._ REQUIRED Duct Systems: Total CFM IRE PREVENTION a uires 3 sets of plans) Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires3 sets of plans) Underground Fire Main Value { q {Requires 3 sets of plans) Fire Hose Cabinets Quantity Commercial Hoods Quantity _ (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Droperty Owners Name L I < <1 4 r a ''`� Phone Number Z` l 'Q t S Zyl-37 0 37y� Mechanical Company �On 6 J a� ���' F �' Office Phone Fax Z '3l5 �o op�1 5 City State Fl Zip32Z s :o. Address: U .icense Holder(Print): G a State Certification/Registration# �'�'�b Jotarized Signature of License Holder 1Y•" RICHARD TOMPKINS Before me this _day of 20__-L- r .5 Commission#FF 040399 "�,•rTo, Expires July 29,zo» Signature of Notary Public -f,}� -,—d Th.Troy Fain Insmix 800.385-7019 Project Summary Job: wri htsoft Date: January2,2013 9 Entire House By: Aaron Thacker Donovan Heat&Air 3156th Ave S. Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project _ • . f For: Lillian Martin 74 Forrestal Cir S,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Btuh Structure 15262 Btuh Ducts 3308 Btuh Ducts 4672 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14590 Btuh Use manufacturer's data 1 00n Rate/swing multiplier Infiltration Equipment sensible load 19934 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Structure 2253 Btuh Fireplaces Ducts 997 Btuh HeatingCoolin Central vent(0 cfm) 0 Btuh Area (ft2) 132132 Equipment latent load 3250 Btuh Volume (ft') 11916 11916 Air changesthour 0.45 0.23 Equipment total load 23184 on Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R41 OA HP Model N4H330A(G)KB* Cond N4H330A(G)KB* AHRI ref no1473903 Coil FEA4X3b**** AHRI ref noS716055 Efficiency -7,7HSPF Efficiency 10.1 EER, 13 SEER Heating input Sensible cooling 20160 Btuh Heating output 39WO Btuh @ 47°F Latent cooling 8640 Stuh tuh Temperature rise 32 OF Total cooling 28800 960 cfm Actual air flow 960 cfm Actual air flow 0.048 cfm/Btuh Air flow factor 0.066 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. I 2014-Jon-02 14:04:37 -f J+ wrightsoft Right-Suite®universal 8 0.24 RSU05995 Page 1 G\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc=MJ8 Front Door faces: E