Loading...
325 Royal Palms Dr 2014 HVAC CITY OF ATLANTIC BEACH l 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000044 Date 1/15/14 Property Address . . . . . . 325 ROYAL PALMS DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 --------------------------------------------- Application desc 1 cu 1 ahu ------------------------------------------ Owner Contractor - ------------------------ ----------------------- SEEDOR, GOLDEN CYNTHIA I TRUST ONEHOUR AI IC BLVD #249 325 ROYAL PALMS DR 1015 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 222-8482 ----------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 91 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/14/14 --------------------- ------------------------------ Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 Fee summary Charged Paid Credited Due _ ---------- ---------- ---------- - Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: LsO�Z� 1. 1—VLA PERMIT# PROJECT VALUE $ S'000 ARI# 1ej REQUIRED Air Handling Equipment Only ✓Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Rating Heat: Unit Quantity BTU's Per Unit gREQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity / Tons Per Unit Z - O , Heat: Unit Quantity / BTU's Per Unit Z 3000 Seer Rating REQUIRED Duct Systems: Total CFM Manual J documentation required on residential change out FIRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity (Re q Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. r Phone Number JslP-9 b-3 � Property Owners Name CIN �I � � Mechanical Company 0�� V� �� 2 Office Phone 2�l�Fax2q7-S'SZ G /�2� �� City Stater zip-322,33 Co. Address: //98 ���� License Holder(Print): f - at ertification/Registration#� ��{S/ZD Notarized Si r SHIRLEY L GRAHQyt ( C�-� da J21 ��� 4 _. 'rq AY COMMISSION q DD r e this y - :. .: _,., Q` cXPIRES:February 14.2014 �� 4f..a 9ongedThnuNofrryPublic U re of Notary Pub Job: 126498 Right J® Mobile Report Date: 1/1 512 01 4 -t wrightsoft Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 For: CINDY GILBERT 325 ROYAL PALMS DR,ATLANTIC BEACH, FL 32233 Phone: 386-956-3872 IT-M T.T. • Location: Indoor: Heating Cooling Indoor temperature(°F) 70 75 Jacksonville/Craig, FL, US Design TD(°F) 35 16 Elevation: 43 ft Relative humidity(%o) 30 50 Latitude: 30'NMoisture difference(gr/Ib) 8.4 52.8 Outdoor: Heating Cooling Dry bulb(°F) 35 91 Infiltration: 17 ( M ) Method Simplified Daily range(°F) - 77 Construction quality Average Wet bulb(°F) 0 Wind speed (mph) 15.0 7.5 Fireplaces Component BtuhV Btuh %of load Walls 8.8 6986 39.4 ufiltrQ' Glazing 19.7 4043 22.8 Doors 13.5 283 16 Will Flans Ceilings 1.7 1628 9.2 Floors 2.7 2591 14.6 Infiltration 2.1 2189 12.4 Ducts 0 0 Calirgs Piping 0 0 T7 Ctfa Humidification 0 0 QaziIg Ventilation 0 0 Adjustments 0 Total 17719 100.0 • • • Com onent Btuh/ft2 Btuh % of load Walls 5.1 4078 21.3 Irte-el(Dar's Glazing 38.0 7787 40.7 Valls Doors 11.4 240 1.3 Irfiltration Ceilings 2.6 2484 13.0 Flaas Floors 1.0 958 5.0 527 2.8 Infiltration 0.5 0 0 Ducts 0 0 Ceilings Ventilation 3040 15.9 Internal gains 0 0 Other Blower 0 02org Adjustments 19114 100.0 Total Latent Cooling Load= 2656 Btuh Overall U-value=0.152 Btuh/ftp°F Data entries checked. 2014-Jan-15 05:56:15 Pagel wrightsoft' Right-Suite®universal 2013 13.0.06 Right JO Mobile 4CC�. ..\wstmp\f7ae76e5-75a0-4c5b-a15f-047492b347c5.rup calc=MJ8 Front Door faces: N Job: 126498 Project Summary Date: 1/15/2014 WrightsoftBy: CRAIG EDDY Entire House ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 • . • • For: CINDY GILBERT 325 ROYAL PALMS DR,ATLANTIC BEACH, FL 32233 Phone: 386-956-3872 Notes: 19 - • • • Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 91 °F Outside db 35 °F 75 °F 70 °F Inside db 16 °F Inside db 35 °F Design TD M Design TD Daily range 50 Relative humidity 53 gr/Ib Moisture difference Heating Summary Sensible Cooling Equipment Load Sizing Structure 19114 Btuh Structure 17719 Btuh Ducts 0 Btuh Ducts 0 Btuh 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh 0 Btuh Blower Humidification 0 Btuh Piping 17719 Btuh Use manufacturer's data 1.00 y Equipment load Rate/swing multiplier Infiltration Equipment sensible load 19114 Btuh Simplified Latent Cooling Equipment Load Sizing Method Construction quality Average 2656 Btuh 0 Structure p Btuh Fireplaces Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 2656 Btuh Area(ftz) 960 960 Equipment latent load Volume(ft') 7680 7680 nt total load 21770 Btuh Air changes/hour 0.45 0.23 Equipme2.0 ton Equiv.AVF(cfm) 58 29 Req.total capacity at 0.80 SHR H Cooling Equipment Summary Heating Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Cond GSZ130241 Model GSZ130241 Coil ASPT30C14 AHRI ref 5946198 AHRI ref 5946198 14 SEER 0 HSPF Efficiency 18400 Btuh Efficiency Sensible cooling 4600 Btuh Heating input 0 Btuh @ 47°F Latent cooling 23000 Btuh Heating output 0 °F Total cooling 870 cfm Temperature rise 1099 cfm Actual air flow 0.046 cfm/Btuh Actual air flow 0.062 cfm/Btuh Air flow factor 0 in H2O Air flow factor 0 in H2O Static pressure 0.88 Static pressure Load sensible heat ratio Space thermostat Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jan-1505:56:15 Page 1 WfitghtsOft' Right-Suite®universal 2013 13.0.06 Right J®Mobile AM ...\wstmp\f7ae76e5-75a0-4c5b-a15f-047492b347c5.rup Calc=MJ8 Front Door faces: N Job: 126498 WllghtSQft' Right-J@ Worksheet Date: 1/15/2014 Enure House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 First Floor Entire House 128,0 It 1 Room name 128.0 ft 8.0 fl 2 Exposed wall 8.0 ft 40.0 x 24:h:eaUcool 3 Room height 960.0 fl' 4 Room dimensions 960.0 ft' 5 Room area I Area (f t') Load HTM I Area (f t') Load (Btu Ty Construction U-value Or or perimeter (ft) (Btuh) or perimeter (ft) ( ) number (Btuh/ft'-°F) (Btuh/ft') Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 320 235 2056 1200 0.253 n 8.75 5.11 320 235 2056 1342 64 0 1265 1342 6 12A-Obw 64 0 1265 240 21 21 283 240 1D-c2ow 0.570 n 19.72 20.91 21 283 785 11D0 0.390 n 13.49 11.43 21 785 192 154 1345 192 154 1345 38 0 756 2415 12A-Obw 0.253 e 8.75 5.11 38 0 756 2415 2240 1307 V�/ 0.570 e 19.72 63.01 256 L-1 1D-clow 320 256 2240 1307 364 0 1265 1614 11 yy 11D-c2 253 s 0.570 s 19.72 25.16 64 0 1265 1685 192 154 1345 785 L--G iD-clow 8.75 5.11 192 154 1345 2415 38 0 756 2415 12A-Obw 0.253 w 19.72 63.01 38 0 756 2484 960 960 1628 2484 t—GiD-c2ow 0.570 w 960 1628 958 168-19ad 0.049 - 1.70 2.59 960 960 2591 958 960 960 2591 C 0.078 - 2.70 1.00 960 F 20P-11t 0 0 6 c)AED excursion15530 15547 15530 15547 Envelopelosslgain2199 527 2189 527 0 0 12 a) Infiltration 0 0 b) Room ventilation 8 1840 8 1 840 1200 Occupants @ 230 1200 13 Internal gains: Appliances/other 1 17719 19114 7719 19114 Subtotal(lines 6 to 13) 0 0 0 0 p 0 Less external load 0 0 0 0 0 0 17719 19114 Less transfer 17719 19114 0 Redistribution0 -0 0 % 0 14 Subtotal 0% 0% 0 17719 19114 15 Duct loads 17719 19114 1099 870 Total room load 1099 870 Air required(cfm) Calculations approved by ACCA to meet all re uirements of Manual J 8th Ed. 2014-Jan-1505:56:15 Pagel _ 4++- wrigtlttsoft Right-Suite®Universal 2013 13.0.06 Right J®Mobile A�-'1-1 ...\wstmp\f7ae76e5-75ao-4c5b-al5f-047492b347c5.rup Calc=MJ8 Front Door faces: N Job: 126498 Writ�htSoft� Component Constructions Byte. 1115/2014 CRAIG EDDY Entire House ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 For: CINDY GILBERT 325 ROYAL PALMS DR,ATLANTIC BEACH, FL 32233 Phone:386-956-3872 Indoor: Heating Cooling Location: Indoor temperature(°F) 70 75 Jacksonville/Craig, FL, USDesign TD(°F) 35 16 50 Elevation: 43 ft Relative humidity(%) 30 52 8 Latitude: 30°N Moisture difference(gr/Ib) 8.4 Outdoor: Heating Cooling Dry bulb(°F) 35 91 Infiltration: Simplified Dailyrange(°F) - 17 ( M ) Method Avera e Wet bulb('F) - 77 Construction quality 0 g Wind speed(mph) 15.0 7.5 Fireplaces Or Area 11.1-value Insul R Htg HTM LoBsh CIB�HITM GBtu Construction descriptions ft. Btuh/ft'-°F ft'-°F/Btuh Btuh/ft' Walls n 235 0.253 0 8.75 2056 5.11 1200 12A-Obw:Fnn wall,brk 4"ext,1/2"gypsum board int fnsh,2"x4" a 154 0,253 0 8.75 1345 5.11 785 wood frm s 256 0.253 0 8.75 2240 5.11 1307 w 154 0.253 0 8.75 1345 5.11 785 all 798 0.253 0 8.75 6986 5.11 4078 Partitions (none) Windows 19.7 1265 20.9 1342 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, a 38 0.570 0 19.7 756 63.0 2415 1/8"thk s 64 0.570 0 19.7 1265 25.2 1614 0 19.7 756 63.0 2415 w 38 0.570 19.7 4043 38.0 7787 all 205 0.570 0 Doors n 21 0.390 0 13.5 283 11.4 240 11 DO:Door,wd sc type Ceilings960 0.049 19.0 1.70 1628 2.59 2484 166-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" gypsum board int fnsh Floors960 0.078 11.0 2.70 2591 1.00 958 20P-11t:Fir floor,wd fir,1"thkrls,the fir fnsh,r-11 ext ins,amb ovr 2014-Jan-15 05:56:15 Pagel wriJh tSOW Right-Suite®Universal2013 13.0.0 F6 Right O Mobile jcs ,..\wstmp\f7ae76e5-75a0-4c5b-a15f-047492b347c5.rup Job: 126498 Date: 111512014 - I- wrightSOft AED Assessment By: CRAIG EDDY Entire House ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 For: CINDY GILBERT 325 ROYAL PALMS DR,ATLANTIC BEACH, FL 32233 Phone:386-956-3872 Heating Cooling Indoor: 70 75 Location: Indoor temperature(°F) 35 16 Jacksonville/Craig, FL, US Design TD(°F) 30 50 Elevation: 43 ft Relative humidity N(gr/lb 8.4 52.8 Latitude: 30°N Heating Cooling Moisture difference(g ) Outdoor: 91 Infiltration: Dry bulb(°F) 35 17 ( M ) Daily range(°F) 77 Wet bulb(°F) 15 0 7.5 Wind speed(mph) HourlyGlazing Load 11,00 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 08 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day AMjinit / Nou1Y P erage Maximum hourly g9 lazin load exceeds average by 18.9%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2014-Jan-15 05.56.15 Page 1 } Right-Suite®Universal 2013 13.0.06 Right J®Mobile wrightsoft ...\wstmp\f7ae76e5-75a0-4c5b-a15f-047492b347c5.rup Calc=MJB Front Door faces: N N First Floor First Floor Scale: 1 :67 Job#: 126498 ONE HOUR AIR Page 1 Performed by CRAIG EDDY for: Right-Su ite®Univerg312013 CINDY GILBERT 1198 MAYPORT RD SUITE 1 13.0.06 Right J®Mobile 325 ROYAL PALMS DR ATLANTIC BEACH,FL 32233 2014-Jan-15 05:56:16 ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 -75ao-4c5b-al5f-047492b347c5,rup Phone:386-956-3872