Loading...
719 Selva Lakes Cir 2014 HVAC Y'S, CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 `JJ31�`� Application Number . . . . . 14-00000190 Date 2/10/14 Property Address . . . . . . 719 SELVA LAKES CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ GENTRY, FRANCES M DONOVAN HEATING & AIR 719 SELVA LAKES CIR 315 SIXTH AVENUE SOUTH ATLANTIC BEACH, FL JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/09/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax(904) 247-5845 fOB ADDRESS: I ClI�t7 L ���(: I�' PERMIT# PROJECT VALUE S, 4&20 ' ARI# (oq5P)f 61 _REQUIRED Air Handling Equipment Only 1 Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 3 S Heat: Unit Quantity BTU's Per Unity GZyG Seer RatingQUIRED Duct Systems: Total CFM IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) TIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces _ Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name c»'Y C.r }� Phone Number 1S 3-RrL dechanical Company �����>" ����* £ �'l Office PhoneZYl 3735 Fax 2�l -370:o. Address: ��IS �� 5 City State Zip3"Zz}'0 ,icense Holder(Print): J/V� /r�/'- �'? i A^ State Certification/Registration# Jotarized Signature of License Holder 1'°vaZ,, RICHARD TOMPKINS Before me this �_t day of G' s 20 � — '= Commission#FF 040399 a 'a Expires July 29,2017 Signature of Notary Public 5ondod TFuu Troy Fan Insumme 800.385-7019 wrightsoft Project Summary Job: + Date: 2/7/14 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach, FL 32250 Phone: 241-3785 Email:brandon@donovanac.com Project • • For: Smith 719 Selca Lakes cir, ATLANTIC BEACH, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 'F Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6147 Btuh Ducts 12188 Btuh Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25135 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28746 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1948 Btuh Ducts 2178 Btuh Heating Coolin Central vent (33 cfm) 1196 Btuh Area (ft2 179417N Equipment latent load 5322 Btuh Volume k 16146 16146 Air changes/hour 0.45 0.20 Equipment total load 34068 Btuh Equiv. AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HCC542 Cond 25HCC542 ARI ref no. 6936861 Coil FX4DN043 ARI ref no. 6936861 Efficiency 8.5 HSPF Efficiency 15 SEER Heating input Sensible cooling 28778 Btuh Heating output 40908 Btuh @ 47°F Latent cooling 12334 Btuh Temperature rise 27 °F Total cooling 41112 Btuh Actual air flow 1370 cfm Actual air flow 1370 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. At= _+d_ wrGghtsoft Right-Suite®Universal 7.1.01 RSU05996 2014-Feb-07 10:28:24 ACCK C:\Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N Page 1