174 15th St 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
C
Application Number . . . . . 14-00000187 Date 2/10/14
Property Address . . . . . . 174 15TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 -----
----------------------------------------------------------------------
Application desc
2 . 5 TONS 30K BTU' S
-------------------------------------------------------------
Owner Contractor
------------------------
------------------------
MARCO, JULIE & DAVID DONOVAN HEATING & AIR
315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . - . 00
Permit Fee . . . . 95 . 00 Plan Check Fee
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/09/14 --------------
---------------------------------------------------- --------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax (904) 247-5845
10BADDRESS: i-7q - Of -,T PERMff#
PROJECT VALUE $ I Qq 10 ARI# 1,2 090 REQUIRED
Air Handling Equipment Only Air Handling Unit& Condenser Condenser Only
4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit —
Heat: Unit Quantity BTU's Per Unit Seer Ratin REQUIRED
Duct Systems: Total CFM
ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit z
Heat: Unit Quantity__L_ BTU's Per Unit 30000 Seer Rating 5-3
Duct Systems: Total CFM REQUIRED
�IRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
?IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty— Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTIJ's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER: gePIROY-1s. 4
ermit beco s void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
iis application and know the same to be true and coffecL All provisions of laws and ordinances governing this work wilt be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Iroperty Owners N Phone Number--226 923
office Phone ZY/ 37fs- Fax 2ql 37q5'
Aechanical Company D1r)PJN6,1 110'2 -±—y—/ -,
I city JIN 9e)- State Zip 3?Zr(-1
,o. Address: 31r.
Acense Holder(Print): aiv ovavx State Certification/Registration#
Votarized Signature of Li4cense Holder
20
RD TOMPKINS Before me this day of rek,40
RICHA
commission#FF040399
'QXExpires July 29,20`17 Signature of Notary Public
Bdd Thm Toy Fain Inww"8*3W7019
Job:
wrightsoft Project Summary Date: Feb 03,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach, FL 32250 Phone 904-241-3785 Fax 904-241-3745 Email:aaron@donovanac.com Web:wmN.DonovanAC.com
Proiect Information
For: Julie Marco
174 15th St,Atlantic Beach, FL 32233
Phone: 910-8513
Notes:
—---------
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 oF Outside db 95 'F
Inside db 70 'F Inside db 75 'F
Design TD 31 'F Design TD 20 'F
Daily range L
Relative umidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29125 Btuh Structure 24639 Btuh
Ducts 3175 Btuh Ducts 3759 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh Use manufacturer's data n
Equipment load 32300 Btuh Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28398 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
0 Structure 1801 Btuh
Fireplaces Ducts 718 Btuh
Heati n Coolin C�ntral vent (0 cfm) 0 Btuh
Area (ft') 1089 1082 Equipment latent load 2519 Btuh
Volume (ft') 8656 8656
Air changesthour 0.45 0.23 Equipment total load 30918 Btuh
Equiv.AVF (cfm) 65 33 Req. total capacity at 0.80 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R41 OA H P
Model NXH530GKA* Cond NXH530GKA*
AHRI ref no3670844 Coil FXM4X30**A*
AHRI ref no3670844
Efficiency 8.7 HSPF Efficiency 12.5 EER, 15.3 SEER
Sensible cooling 23040 Btuh
Heating input 5760 Btuh
Heating output 28600 Btuh @ 47-F Latent cooling
Temperature rise 27 'F Total cooling 28800 Btuh
Actual air flow 960 cfm Actual air flow 960 cfm
0.030 cfm/Btuh Air flow factor 0.034 cfm/Btuh
Air flow factor 0 in H20
Static pressure 0 in H20 Static pressure
Space thermostat Load sensible heat ratio 0.92
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed� 2014-Feb-D6 1&0213
Page I
+t+ vvirightSoft Right-Suite&Universal 8.0.24 RSU05995
AC0' c:\users\Owner\Documents\Wrightsoft HVAC\Marco,Julie rup Calc=MJ8 Front Door faces. N