Loading...
211 Beach Ave 2014 HVAC Sys CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J r� ATLANTIC BEACH,FL 32233 i INSPECTION PHONE LINE 247-581 14-00000192 Date 2/10/14 Application Number 211 BEACH AVE Property Address . . . • Application type description MECHANICAL HVAC ONLY Property Zoning - TO BE UPDATED 0 Application valuation . . . -------------------- ----------------------- Application desc 1 CU 1 AHU ------------------ ------------------ Contractor Owner ------------------------ ------------------------ ------ IR SIMMONS RICHARD L DONOVAN HEATING & A 211 BEACH AVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ------------ ----- ------------ Permit MECHANICAL HVAC PERMIT Additional desc . • Plan Check Fee . 00 Permit Fee . . . . 107 . 00 0 Valuation Issue Date g/09/14 Expiration Date ------- ------------------ ------ ------------ ----- - STATE MECH DCA SURCHARGE 2 . 00 Other Fees • • • . ' • . STATE MECH DBPR SURCHARGE 2 . 00 -------------------Paid----- ---- --------------- - - Credited --- Due Fee summaryCharged ---------- --------- ---------- . 00 Permit Fee Total 107 . 00 107 . 00 . 00 Plan Check Total 00 00 • 004 . 00 . 00 . 00 Other Fee Total 4 . 00 00 . 00 111 . 00 111 . 00 Grand Total PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 (OB ADDRESS: I U��N PERMIT# PROJECT VALUE $ g530` ARI# b%5 5 2 R I REQUIRED _Air Handling Equipment Only __LAir Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Ratin Heat: Unit Quantity ______ BTU's Per Unit gREQUIRED Duct Systems: Total CFM 2EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit �' Heat: Unit Quantity I BTU's Per Unit Seer RatingREQUIRED Duct Systems: Total CFM IRE PREVENTION 3 sets of plans) Fire Sprinkler System Quantity (Requires(Reuirs 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value - Re uires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity - (Requires 3 sets of plans) Fire Suppression Systems Quantity ?IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts BTU's Gas Piping Outlets Boilers Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: th period or work is r six months.I hereby certify that I have read ermit becomes void if work does niotcom�m1e and within a six All provisions s ons of laws and ordinances governing this andoned work will be complied with whether specified or pis application and know the same ot. The permit does not give autho y to violate the provisions of any other state or local law regulation construction or the performance of co 'roperty Owners Name l C�►6,�Q t m m:,� S Phone Number 1 l ZY137$S!Fax Z�� 37 j � ne1f dechanicalCom y O 37 2 so ;o. Address: I 1 AV E� City 13J- State F� Zip Len p,/d„� State Certification/Registration#.icense Holder(Print): A - J t ' e Cignature of LHolder 1Y'i,g.. RICHARD TOMPKINS day 20 ` Commission#FF 040399 Before me this Expires July 29,2017 Raided TMu Troy Fain Insurance— Signature of Notary Public %�p;�°F' 800-385-7019 Job: +!+ wrightsoft Project Summary Date: 217/14 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone: 241-3785 Email:brandon@donovanac.com Proiect Information For: Simmons 211 Beeach ave,Atlantic Beach, FL 32233 Notes: Desicin Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 95 °F Outside db 39 °F 75 °F Inside db Inside db 68 F 0 °F Desi n TD 29 °F Design TD 2 L g Daily range Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21477 Btuh Structure 17679 Btuh Ducts 7576 Btuh Ducts 15456 Btuh 1804 Btuh Central vent (57 cfm) 1244 Btuh Central vent (57 cfm) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuhn Equipment load 30857 Btuh Use manufacturer's data 1.00 Rate/swing multiplier Infiltration Equipment sensible load 34379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2029 Btuh Fireplaces 1 (Average) Structure Ducts 2778 Btuh Btuh Heating Cooling Central vent (57 cfm) 26047 047 Btuh Area (ft') 2336 2336 Equipment latent load Volume (ft3) 21024 21024 total 41233 Btuh Air changes/hour 32 0. 0.16 Equipment quipm altcapaclity at 0.70 SHR 4.1 ton Equiv.AVF (cfm) Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model NXH548 Cond NXH548 ARI ref no. 6955291 Coil FXM4X48 ARI ref no. 6955291 15 SEER Efficiency 8.5 HSPF Efficiency 32282 Btuh Heating Input Sensible cooling 13840 Btuh Heating output 45903 Btuh @ 47°F Latent cooling 46132 Btuh Temperature rise 27 °F Total cooling 1538 cfm Actual air flow 1538 cfm Actual air flow 0.046 cfm/Btuh Air flow factor 0.053 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0.83 Space thermostat Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2014-Feb-07 11:15:25 +�+ wrightsoft Right-Suite®Universal 7.1.01 RSU05996 Page 1 /CCA c:\users\Sales\Documents\Wrightsoft HVAC\4 TON.rup Calc=MJ8 Orientation=N