1633 Selva Marina Dr 2014 - HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000173 Date 2/06/14
Property Address . . . . . . 1633 SELVA MARINA DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
2 tons 24K btus
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
FERGUSON, MICHAEL ALAN DONOVAN HEATING & AIR
1633 SELVA MARINA DR 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 322335615 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/05/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC ]BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904)247-S826 Fax(904) 247-5845
roB ADDRESS:
�191. M012-12A _P1ERMff#
PROJECT VAL 17E S SS0 A)U# 5(;-7 OS--�0 - -AEQUIRED
—Air Handling EqWpment Only _X Air Handling Unit& Condenser Condenser Only
qEW AIR CONDMONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat; Unit Quantity BTU's Per Unit Seer Rating_
Duct Systems-, Total CFM REQUIRED
ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 21
Heat: Unit Quantity I BTU'sPerunit 2YQQQ Seer Rating /,S�2-
Duct Systems: Total Cr-M REQUIRED
�IRE PREV10MOT
N
Fire Sprinkler System Quantity (RequJres 3 sets of plans)
Fire Standpipe Quantity (Requires 3 " of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantiw (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 set-q of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
'IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty
GasPiping outlets Automobile Lifts
Boilers BTU's
Elevators/E-scalators
,1,L OTHER GAS P11PING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Reffigermor Condenser BTU's
Water Heaters, Solar Collection Systems
Tanks(gallons)
Wells
1THER:
rmit becomes void if work does not commence within tj six month period or work is suspended or abandoned�for six month§�I hereby certify that I have read
s application and know the some to be irue nnd comet. All provisions of law.;and ordinances governing this work will be complied with whether specified or
�, The permit does not give Finthority to violaw the provisions of any other state or local Im regulation construction or the perfbTmance orconstruction.
operty Owners Name Vqu,= PhorkeNumber 36S -
echarlical Company Office Phone J�L2YI37SJ'Fax O�ZY_/�37 '
). Address:
city Cj_ state fL zir�zz)
cense Holder(Print): State Certification/Registration
itarked Signature of License 11older_kw 42-4�2 �
RICHARD TOMPKINS Before me this day of 20,__/�
4 Commission 4 Fr 0403ga
4.,
"" ' EONS July 29,2017
,jn,
-As'so Banded Thm TrAy roin?niU,,,,, Signature of Notary Public 1,1 ZU
wrightscift- PrOjed Summary Job:
Entire House Date., February 5,Z014
Donovan Heat&Air BY: Aaron Thacker
315 6th Avc,S,Jeck-tonvile Beec-li, ri.32250 Phone:904-241-3785 Fax 904-241-3745 EMIP:a-arongTdonovarao.00rn Web;vAwDonovnnAG,Corn
For: Alan Ferguson
1633 Sefira Marina Dr, Atlantic Beach, FL 32233
Notes-
Weather: Jacksonxd1le Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 oF Outside db 99 `F
Inside db 70 oF Inside db 75 "F
Design TO 31 6F Design TD 24 6F
Dail
,y.range L
Re ative umidity 60 %
Moisture difference 69 gr/lb
h1eating Summary Sensible Cooling Equipment Load Sizing
Structure 10754 Stuh Structure 9911 l3tuh
Ducts 1864 Btuh Ducts 3268 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Stuh Blower
Pipigg 0 Btuh 0 Btuh
Equipment load 12618 Btuh Use manufacturers data n
Rate/swin multiplier 1.04
Infiltration EquipmeMensible load 13705 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2241 Stuh
Ducts 926 Btuh
Heatin Cooling Central vent(0 cfm) 0 Btuh
Area (ft2) 1149 114 Equipment latent load 3166 Btuh
Volume (" 9120 9120
Air chan es/hour 0.45 0.23 Equipment total load 16872 8tuh
OF (cfm)
Equiv A 68 35 Req. total capacity at 0.70 SHR 1.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R41 OA HIP
Model N)(H524GKA* Cond NXH524GKA*
AHRI ref no3670830 - Coil FXM4X24**A*
AHRI ref no3670830
Efficiency 8.7 HSPF Efficiency 12.5 EER, 15.3 SEER
Heating input Sensible cooling 16800 Btuh
Heating output 24000 Btuh @ 47*F Latent cooling 7200 Stuh
Temperature rise 27 6F Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.063 cfm/Btuh Air flow factor 0.061 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.81
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+1+ wrightiwit- Ripht-8000 Universol 8.0.24 RSU05995 2014-Feb-05 11:21:X
C:\U9enR�0vmonDo(,urnentR=r10h0 oft WAC,EioguR 2 ton.rup Calc=MA From Door fhovs- W Page 1