266 Poinsettia St 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000251 Date 2/20/14
Property Address . . . . . . 266 POINSETTIA ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
TOWNSEND DIANA K ONE HOUR AIR
266 POINSETTIA ST 101S ATLANTIC BLVD #249
ATLANTIC BEACH FL 322334020 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/19/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
PTL-
JOB ADDRESS: ZIQ\s 1C. A�3C-A_C)ck R2�- -3+ERMIT
PROJECT VALUE $ SS 3 Le ARI# E�3Q', -2-71 —REQUIRED
Air Handling Equipment Only ZAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 2-- 5 Seer Rating ) 3
Heat: Unit Quantity I BTU's Per Unit 2- -7 c>oc> —
Duct Systems: Total CFM REQUIRED
Manual J documentation required on residential change out
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certi ly that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Dlar�-A MnNKSet,�_C-) PhoneNumber
Mechanical Company CAJ 9- �-6 U re- Office Phone ZI L-75167 Fax2.q7-S YL Z_6
City AZ#48� Statea zia32233
Co. Address: /199 MA40=117 1?011�
License Holder(Print): ZAIG, E. at ertification/Registration #c4c ILI YZ-0
Notarize S* i[Licelge Molder �;W/�
day 0
11HIRLEY L GWAM /,
11) A*rd e this da 0-
AY COMMISSION#DD
EXPIRES:February 14,2014
otary Pub
I ......1� lonOtd Thru Notsty Public U
re of Notary Pub
Job: 126992
Right J@ Mobile Report Date: 2/2012014
wrightsoll, Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
Proiect Information
For: DIANA TOWNSEND
266 POINSTTIA ST,ATLANTIC BEACH, FL 32233
Phone: 904-422-0511
1 Design Conditions
Indoor: Heating Cooling
Location: 75
Jacksonville/Craig, FL, US Indoor temperature(OF) 70
Elevation: 43 ft Design TD (OF) 35 16
Latitude: 30'N Relative humidity 1(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(OF) 35 91 Infiltration:
Daily range(OF) - 17 M Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Heating
omponent Btu htft' Btuh % of load
Walls 8.8 5004 30.0 Ii-filbion
Glazing 19.7 5982 35.9 Wills
Doors 13.5 283 1.7 Ro3s
Ceilings 1.7 1221 7.3
Floors 2.7 1943 11.7
Infiltration 2.5 2225 13.4 firgs
Ducts 0 0 ChEr
piping 0 0 7Z;9
Humidification 0 0 Cla&g
Ventilation 0
16659 0
Total 01
Adjustments 0 100.
Component Btu h/ft2 Btuh %of load
Walls 5.1 2922 12.1 V\dIS Irterd Gains
Glazing 48.7 14782 61.3 Irfiftration
Doors 11.4 240 1.0 RocrS
Ceilings 2.6 1863 7.7 Ceflirgs
Floors 1.0 719 3.0
Infiltration 0.6 550 2.3 QhEr
Ducts 0 0
Ventilation 0 0
Internal gains 3040 12.6
Blower 0 0
Adjustments 0 G.-drg
Total 1 24115 100.01
Latent Cooling Load =2702 Btuh
Overall U-value =0.179 Btuh/ft2_OF
WARNING:window to floor area ratio 42.1%-more than 25%.
2014-Feb-20 05:34:21
Page
wrightsOft' Right-Suitev universal 2013 13.0.06 Right J@ Mobile
,AF-Ck \wstmp\833blb8a-7d65-46eB-83fc-27c5fb53d2c4.rup CaIc=MJ8 FrontDoorfaces: N
Job: 126992
Project Summary Date: 2/20/2014
+ wrightsoft Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
For: DIANA TOWNSEND
266 POINSTTIA ST,ATLANTIC BEACH, FIL 32233
Phone: 904-422-0511
Notes:
a9fi&- Lei I
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
70 'F Inside db 75 'F
Inside c1b 35 'F Design TID 16 'F
Design TD Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16659 Btuh Structure 24115 Btuh
0 Btuh Ducts 0 Btuh
Ducts 0 Btuh Central vent (0 cfm) 0 Btuh
Central vent (0 cfm) 0 Btuh Blower 0 Btuh
Humidification 0 Btuh
Piping Use manufacturer's data y
Equipment load 16659 Btuh Rate/swing multiplier 1.00
Infiltration Equipment sensible load 24115 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
0 Structure 2702 Btuh
Fireplaces Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft') 720 720 Equipment latent load 2702 Btuh
Volume (ft) 5760 5760 Equipment total load 26817 Btuh
Air changes/hour 0.61 0.32 HR 2.5 ton
Equiv.AVF (cfm) 59 31 Req.total capacity at 0.80 S
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS
Model GSZ130301 Cond GSZI 30301
AHRI ref 5358271 Coil ARUF301314
AHRI ref 5358271 13 SEER
Efficiency 0 HSPF Efficiency 21760 Btuh
Heating input Sensible cooling 5440 Btuh
Heating output 0 Btuh @ 47oF Latent cooling 27200 Btuh
Temperature rise 0 'F Total cooling 1098 cfm
Actual air flow 0 cfm Actual air flow 0.046 cfm/Btuh
Air flow factor 0 cfm/Btuh Air flow factor 0 in H20
0 in H20 Static pressure
Static pressure Load sensible heat ratio 0.90
Space thermostat
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Feb-20 0534*21
Page
vivrights0ft' Right-Suitev Universal 2013 13�0.06 Right J@ Mobile
A--(51 \wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup calc=MJ8 Front Doorfaces: N
Job: 126992
wrightsoft Right-j@ Worksheet Date: 2/20/2014
Endre House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
Entire House First Floor
I Room name 1Q.0 ft 112.0 ft heat/cool
2 Exposed wall 8.0 ft d 8.0 It
3 Room height 20.0 x 36.0 ft
4 Room dimensions 720.0 ft2 720.0 W
5 Room area
— Ty Construction If I') Load Ar a (ft Load
U-value Or HTIM Area I, (ft) (Btuh)
number (Btuh/ft2-*F) (Bt uh/f t') or perimeter (ft) (Btuh) or penme er
Heat Cool Gross N/P/S Heat Cool . Gross N/P/S
L— 160 85 743 434 160 85 1743 44
0 n 1133 54 0 068 1 1 33
12 '�2" " '�7'1 0 1068 2�3 24
6 VLt I ft0bw 1172 20�11 54
2.w 570 21 21
0.390 n 13 1668 74
B�74, 115 3 21 21 283 240 288 191
5 �4
Vt 11DO 'l 288 191 1668 974 1923 6143
__G 1 2A-Obw 0.253 e 615-01 98 0 1923 6143 98 0 926 541
1 D-c2ow 0.570 e 75 11 161 106 926 541 160 106
2A-Ob 0.253 s 0 1068 1363
0.570 s 19 25.16 54 0 1068 1363 54
t--G 'ID-c2o 8 2 66 974
1 0.253 w 75 5.11 288 191 668 974 288 191 8
2A-01bw 1'�7 1923 6143 98 0 11923 6143
VL—G 0.570 w 72 63.01 98 0 1 1221 1863
1 D-c2o 0.049 1.70 2.59 720 720 1221 1863 720 720 719
C 16B-19ad 0.078 270 1.00 720 720 1943 719 720 720 1943
F 20P-1 lt
0
6 1 c)AED excursion 14434 20525
-7nnvel.p.I.ss1g.in
rT I in 2225 550 2225 550
12 a) Infiltration 0 0 0
b) Room ventilation 1840
n n
occ
I f"'ra"o EAp p
-ion
Room ventIE 8 1840 8
N13 EInternal gains: Occupants Q 230 1200 1200
Appliances/other 16659 24115
S'u"I."
'I
ubtotal(lines 6 to 13) 16659 241151 0 0
0 0 0
Less external=load 0 0 0
Less transfer n 0
16659 24115
[LRedistribution
u to 1 -0% 0% 0 0
14 Subtotal
15 Duct loads 166591 24�115
I 09j
Total room load 109�L 0 8
Air required(cfm)
Calculations approved lov ACCA to meet al re uirements of Manual J 8th Ed. 2014-Feb-20 05:34:21
Af�z>'444- wrights0ft Right-Suite,E)Universal 2013 13.0,06 Right JO Mobile Page i
\wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup Calc=MJ8 Front Door faces: N
Job: 126992
Component Constructions Date: 212012014
wrightsoft' Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
For: DIANA TOWNSEND ACH,FL 32233
266 POINSTTIA ST,ATLANTIC BE
Phone:904-422-0511
Heating Cooling
Location: Indoor: 70 75
Jacksonville/Craig, FL, US Indoor temperature(*F) 35 16
Design TID(*F) 30 50
Elevation: 43 ft Relative humidity I(%)
Latitude: 30*N Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Outdoor:
Dry bulb(*F) 35 91 Infiltration:
- 17 ( M Method Simplified
Dailyrange(*F) - 77 Construction quality Average
Wet bulb(*F) 0
Wind speed(mph) 15.0 7.5 Fireplaces
Or Area U-value Insul R Htg HTIVI Loss CIg HTIVI Gain
Construction descriptions ft. Btuhiff-'F fV-'FA3tuh Btuhffi' Btuh 13bbiff Btuh
Walls 0.253 0 8.75 743 5.11 434
12A-Obw:Frm wall,brk 4"ext,1/2"gypsum board int fnsh,Tx4" n 85 5.11 974
e 191 0.253 0 8.75 1668
wood frm s 106 0.253 0 8.75 926 5,11 541
w 191 0.253 0 8.75 1668 5.11 974
all 572 0.253 0 8.75 5004 5.11 2922
Partitions
(none)
Windows 54 0.570 0 19.7 1068 20.9 1133
1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innr,1/4"gap, n 19.7 1923 63.0 6143
1/9'thk e 98 0.570 0 19.7 1068 25.2 1363
s 54 0.570 0 19.7 1923 63.0 6143
w 98 0.570 0 19.7 5982 48.7 14782
all 303 0.570 0
Doors n 21 0.390 0 13.5 283 11.4 240
11 DO:Door,wd sc type
Ceilings 720 0.049 19.0 1.70 1221 2.59 1863
1613-19ad:Attic ceiling,asphalt shingles roof mat,r-19 cell ins,1/2"
gypsum board int fnsh
Floors 720 0.078 11.0 2.70 1943 1.00 719
20P-1 it:Flr floor,wd fir,1"thkrr,,tile fir fnsh,r-1 I ext ins,amb ovr
2014-Feb-20 05:34:21
V Wbile Pagel
wrightSOM Right-SuitelD Universal 2013 13.0.06 Right i
\wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup Calc=MJ8 FrontDoorfaces: IN
Job: 126992
-r.JL AED Assessment Date: 2/20/2014
wrightsol L Entire House By: cRAIG EDDY
ONE HOUR AIR
FIL 32233 Phonei 904-241-3107 Fax:904-247-5526 License:CAC1814420
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH, — —
— For: DIANA TOWNSEND
266 POINSTTIA ST,ATLANTIC BEACH, FL 32233
Phone: 904-422-0511
M Heating Cooling
Indoor: perature ('F) 70 75
Location: Indoor tem 35 16
Jacksonville/Craig, FL, US Design TID('F) 30 50
Elevation: 43 ft Relative humidity 1(%) 8.4 52.8
Latitude: 30'N Heating Cooling Moisture difference (gr/lb)
Outdoor: 35 91 Infiltration:
Dry bulb('F) 17 M
Dailyrange('F) 77
Wet bulb('F) 15.0 7.5
Wind speed(mph)
SM M- a Tre
Hourly Glazing Load
20,00� ......................................
18100� ... ..........
16,00�
12,00
14,00�
1 0,00
8,00
6,00
4,00,
2,00
I
0 r) 19 20
8 9 10 11 12 13 14 15 16 17 18
Hour of Day AMlinit
Haxiy Aerage
Maximum hourly glazing load exceeds average by 20.7%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2014-Feb-20 05:34111
Page
-Slite@unweirsaI201313.0.06 Right jj�)Mobile
wrightsOft' Right
up calc=MJ8 FrontDoorfaces: N
...\wstmp\833blb8a-7d65-46e8-B3fc-27c5fb53d2c4.r
First Floor
First Floor
Scale: 1 54
ONE HOUR AIR Page
job #: 126992 Rig ht-Su it e(D Univ ers a 120 13
Performed bY CRAIG EDDY for: I 198 MAypORT RD SUITE 1 13.0.06 Right j@ Mobile
DIANA TOWNSEND ATLANTIC BEACH,FL 32233 2014-Feb-20 o5:34:22
266 POINSTTIA ST Phone:904-241-3107 Fax!904-247-5526 ..,-7d65-46e8-83tc-27c5fb53d2C4.ruP
ATLANTIC BEACH,FL 32233
Phonei 904-422-0511
CERTIFIED'
wwvv.a hri directory,org
Certificate of Product Ratings,
AHRI Certified Reference Number: 5358271 Date: 2/19/2014
Product: split System: Heat pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130301A*
Indoor Unit Model Number: ARUF30B14A*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Series name: GSZ13
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh)-. 27200
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 27000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F: 16500
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER orse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
AHRI does not end .AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
the product(s)listed on this Certificate ertified ratings are valid only for models and configurations listed in the
unauthorized alteration of data listed on this Certificate.C
directory at www,ahridirectorY�Org. n nd
CONDITIONS 3 a'a ,
TERMS AND eminated;
This Certificate and its contents are pr,oprietary products of AHRI.This Certificate shall only be used for individua perso
confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;dis,- AM
entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING.
&REFRIGERATION INSTITUTE
personal and confidential reference.
CERTIFICATE VERIFICATION n this certificate can be verified at www.abridirectory.org,click on"Verify Certificate"link we make life.better"
The information for the model cited o date on which the certificate was issued, ..............--_
and enter the AHRI Certified Reference Number and the 1303731G4449372074
which is listed above,and the Certificate No.,which is listed at bottom right. CERTIFICATE NO.:
Q2014 Air-Conditioning,Heating,and Refrigeration Institute