266 Poinsettia St 2014 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000251 Date 2/20/14 Property Address . . . . . . 266 POINSETTIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ TOWNSEND DIANA K ONE HOUR AIR 266 POINSETTIA ST 101S ATLANTIC BLVD #249 ATLANTIC BEACH FL 322334020 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/19/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 PTL- JOB ADDRESS: ZIQ\s 1C. A�3C-A_C)ck R2�- -3+ERMIT PROJECT VALUE $ SS 3 Le ARI# E�3Q', -2-71 —REQUIRED Air Handling Equipment Only ZAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 2-- 5 Seer Rating ) 3 Heat: Unit Quantity I BTU's Per Unit 2- -7 c>oc> — Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certi ly that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Dlar�-A MnNKSet,�_C-) PhoneNumber Mechanical Company CAJ 9- �-6 U re- Office Phone ZI L-75167 Fax2.q7-S YL Z_6 City AZ#48� Statea zia32233 Co. Address: /199 MA40=117 1?011� License Holder(Print): ZAIG, E. at ertification/Registration #c4c ILI YZ-0 Notarize S* i[Licelge Molder �;W/� day 0 11HIRLEY L GWAM /, 11) A*rd e this da 0- AY COMMISSION#DD EXPIRES:February 14,2014 otary Pub I ......1� lonOtd Thru Notsty Public U re of Notary Pub Job: 126992 Right J@ Mobile Report Date: 2/2012014 wrightsoll, Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Proiect Information For: DIANA TOWNSEND 266 POINSTTIA ST,ATLANTIC BEACH, FL 32233 Phone: 904-422-0511 1 Design Conditions Indoor: Heating Cooling Location: 75 Jacksonville/Craig, FL, US Indoor temperature(OF) 70 Elevation: 43 ft Design TD (OF) 35 16 Latitude: 30'N Relative humidity 1(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infiltration: Daily range(OF) - 17 M Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating omponent Btu htft' Btuh % of load Walls 8.8 5004 30.0 Ii-filbion Glazing 19.7 5982 35.9 Wills Doors 13.5 283 1.7 Ro3s Ceilings 1.7 1221 7.3 Floors 2.7 1943 11.7 Infiltration 2.5 2225 13.4 firgs Ducts 0 0 ChEr piping 0 0 7Z;9 Humidification 0 0 Cla&g Ventilation 0 16659 0 Total 01 Adjustments 0 100. Component Btu h/ft2 Btuh %of load Walls 5.1 2922 12.1 V\dIS Irterd Gains Glazing 48.7 14782 61.3 Irfiftration Doors 11.4 240 1.0 RocrS Ceilings 2.6 1863 7.7 Ceflirgs Floors 1.0 719 3.0 Infiltration 0.6 550 2.3 QhEr Ducts 0 0 Ventilation 0 0 Internal gains 3040 12.6 Blower 0 0 Adjustments 0 G.-drg Total 1 24115 100.01 Latent Cooling Load =2702 Btuh Overall U-value =0.179 Btuh/ft2_OF WARNING:window to floor area ratio 42.1%-more than 25%. 2014-Feb-20 05:34:21 Page wrightsOft' Right-Suitev universal 2013 13.0.06 Right J@ Mobile ,AF-Ck \wstmp\833blb8a-7d65-46eB-83fc-27c5fb53d2c4.rup CaIc=MJ8 FrontDoorfaces: N Job: 126992 Project Summary Date: 2/20/2014 + wrightsoft Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 For: DIANA TOWNSEND 266 POINSTTIA ST,ATLANTIC BEACH, FIL 32233 Phone: 904-422-0511 Notes: a9fi&- Lei I Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F 70 'F Inside db 75 'F Inside c1b 35 'F Design TID 16 'F Design TD Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16659 Btuh Structure 24115 Btuh 0 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping Use manufacturer's data y Equipment load 16659 Btuh Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24115 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 0 Structure 2702 Btuh Fireplaces Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 720 720 Equipment latent load 2702 Btuh Volume (ft) 5760 5760 Equipment total load 26817 Btuh Air changes/hour 0.61 0.32 HR 2.5 ton Equiv.AVF (cfm) 59 31 Req.total capacity at 0.80 S Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Model GSZ130301 Cond GSZI 30301 AHRI ref 5358271 Coil ARUF301314 AHRI ref 5358271 13 SEER Efficiency 0 HSPF Efficiency 21760 Btuh Heating input Sensible cooling 5440 Btuh Heating output 0 Btuh @ 47oF Latent cooling 27200 Btuh Temperature rise 0 'F Total cooling 1098 cfm Actual air flow 0 cfm Actual air flow 0.046 cfm/Btuh Air flow factor 0 cfm/Btuh Air flow factor 0 in H20 0 in H20 Static pressure Static pressure Load sensible heat ratio 0.90 Space thermostat Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Feb-20 0534*21 Page vivrights0ft' Right-Suitev Universal 2013 13�0.06 Right J@ Mobile A--(51 \wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup calc=MJ8 Front Doorfaces: N Job: 126992 wrightsoft Right-j@ Worksheet Date: 2/20/2014 Endre House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Entire House First Floor I Room name 1Q.0 ft 112.0 ft heat/cool 2 Exposed wall 8.0 ft d 8.0 It 3 Room height 20.0 x 36.0 ft 4 Room dimensions 720.0 ft2 720.0 W 5 Room area — Ty Construction If I') Load Ar a (ft Load U-value Or HTIM Area I, (ft) (Btuh) number (Btuh/ft2-*F) (Bt uh/f t') or perimeter (ft) (Btuh) or penme er Heat Cool Gross N/P/S Heat Cool . Gross N/P/S L— 160 85 743 434 160 85 1743 44 0 n 1133 54 0 068 1 1 33 12 '�2" " '�7'1 0 1068 2�3 24 6 VLt I ft0bw 1172 20�11 54 2.w 570 21 21 0.390 n 13 1668 74 B�74, 115 3 21 21 283 240 288 191 5 �4 Vt 11DO 'l 288 191 1668 974 1923 6143 __G 1 2A-Obw 0.253 e 615-01 98 0 1923 6143 98 0 926 541 1 D-c2ow 0.570 e 75 11 161 106 926 541 160 106 2A-Ob 0.253 s 0 1068 1363 0.570 s 19 25.16 54 0 1068 1363 54 t--G 'ID-c2o 8 2 66 974 1 0.253 w 75 5.11 288 191 668 974 288 191 8 2A-01bw 1'�7 1923 6143 98 0 11923 6143 VL—G 0.570 w 72 63.01 98 0 1 1221 1863 1 D-c2o 0.049 1.70 2.59 720 720 1221 1863 720 720 719 C 16B-19ad 0.078 270 1.00 720 720 1943 719 720 720 1943 F 20P-1 lt 0 6 1 c)AED excursion 14434 20525 -7nnvel.p.I.ss1g.in rT I in 2225 550 2225 550 12 a) Infiltration 0 0 0 b) Room ventilation 1840 n n occ I f"'ra"o EAp p -ion Room ventIE 8 1840 8 N13 EInternal gains: Occupants Q 230 1200 1200 Appliances/other 16659 24115 S'u"I." 'I ubtotal(lines 6 to 13) 16659 241151 0 0 0 0 0 Less external=load 0 0 0 Less transfer n 0 16659 24115 [LRedistribution u to 1 -0% 0% 0 0 14 Subtotal 15 Duct loads 166591 24�115 I 09j Total room load 109�L 0 8 Air required(cfm) Calculations approved lov ACCA to meet al re uirements of Manual J 8th Ed. 2014-Feb-20 05:34:21 Af�z>'444- wrights0ft Right-Suite,E)Universal 2013 13.0,06 Right JO Mobile Page i \wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup Calc=MJ8 Front Door faces: N Job: 126992 Component Constructions Date: 212012014 wrightsoft' Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 For: DIANA TOWNSEND ACH,FL 32233 266 POINSTTIA ST,ATLANTIC BE Phone:904-422-0511 Heating Cooling Location: Indoor: 70 75 Jacksonville/Craig, FL, US Indoor temperature(*F) 35 16 Design TID(*F) 30 50 Elevation: 43 ft Relative humidity I(%) Latitude: 30*N Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Outdoor: Dry bulb(*F) 35 91 Infiltration: - 17 ( M Method Simplified Dailyrange(*F) - 77 Construction quality Average Wet bulb(*F) 0 Wind speed(mph) 15.0 7.5 Fireplaces Or Area U-value Insul R Htg HTIVI Loss CIg HTIVI Gain Construction descriptions ft. Btuhiff-'F fV-'FA3tuh Btuhffi' Btuh 13bbiff Btuh Walls 0.253 0 8.75 743 5.11 434 12A-Obw:Frm wall,brk 4"ext,1/2"gypsum board int fnsh,Tx4" n 85 5.11 974 e 191 0.253 0 8.75 1668 wood frm s 106 0.253 0 8.75 926 5,11 541 w 191 0.253 0 8.75 1668 5.11 974 all 572 0.253 0 8.75 5004 5.11 2922 Partitions (none) Windows 54 0.570 0 19.7 1068 20.9 1133 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innr,1/4"gap, n 19.7 1923 63.0 6143 1/9'thk e 98 0.570 0 19.7 1068 25.2 1363 s 54 0.570 0 19.7 1923 63.0 6143 w 98 0.570 0 19.7 5982 48.7 14782 all 303 0.570 0 Doors n 21 0.390 0 13.5 283 11.4 240 11 DO:Door,wd sc type Ceilings 720 0.049 19.0 1.70 1221 2.59 1863 1613-19ad:Attic ceiling,asphalt shingles roof mat,r-19 cell ins,1/2" gypsum board int fnsh Floors 720 0.078 11.0 2.70 1943 1.00 719 20P-1 it:Flr floor,wd fir,1"thkrr,,tile fir fnsh,r-1 I ext ins,amb ovr 2014-Feb-20 05:34:21 V Wbile Pagel wrightSOM Right-SuitelD Universal 2013 13.0.06 Right i \wstmp\833blb8a-7d65-46e8-83fc-27c5fb53d2c4.rup Calc=MJ8 FrontDoorfaces: IN Job: 126992 -r.JL AED Assessment Date: 2/20/2014 wrightsol L Entire House By: cRAIG EDDY ONE HOUR AIR FIL 32233 Phonei 904-241-3107 Fax:904-247-5526 License:CAC1814420 1198 MAYPORT RD SUITE 1,ATLANTIC BEACH, — — — For: DIANA TOWNSEND 266 POINSTTIA ST,ATLANTIC BEACH, FL 32233 Phone: 904-422-0511 M Heating Cooling Indoor: perature ('F) 70 75 Location: Indoor tem 35 16 Jacksonville/Craig, FL, US Design TID('F) 30 50 Elevation: 43 ft Relative humidity 1(%) 8.4 52.8 Latitude: 30'N Heating Cooling Moisture difference (gr/lb) Outdoor: 35 91 Infiltration: Dry bulb('F) 17 M Dailyrange('F) 77 Wet bulb('F) 15.0 7.5 Wind speed(mph) SM M- a Tre Hourly Glazing Load 20,00� ...................................... 18100� ... .......... 16,00� 12,00 14,00� 1 0,00 8,00 6,00 4,00, 2,00 I 0 r) 19 20 8 9 10 11 12 13 14 15 16 17 18 Hour of Day AMlinit Haxiy Aerage Maximum hourly glazing load exceeds average by 20.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2014-Feb-20 05:34111 Page -Slite@unweirsaI201313.0.06 Right jj�)Mobile wrightsOft' Right up calc=MJ8 FrontDoorfaces: N ...\wstmp\833blb8a-7d65-46e8-B3fc-27c5fb53d2c4.r First Floor First Floor Scale: 1 54 ONE HOUR AIR Page job #: 126992 Rig ht-Su it e(D Univ ers a 120 13 Performed bY CRAIG EDDY for: I 198 MAypORT RD SUITE 1 13.0.06 Right j@ Mobile DIANA TOWNSEND ATLANTIC BEACH,FL 32233 2014-Feb-20 o5:34:22 266 POINSTTIA ST Phone:904-241-3107 Fax!904-247-5526 ..,-7d65-46e8-83tc-27c5fb53d2C4.ruP ATLANTIC BEACH,FL 32233 Phonei 904-422-0511 CERTIFIED' wwvv.a hri directory,org Certificate of Product Ratings, AHRI Certified Reference Number: 5358271 Date: 2/19/2014 Product: split System: Heat pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130301A* Indoor Unit Model Number: ARUF30B14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Series name: GSZ13 Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh)-. 27200 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 27000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 16500 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER orse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, AHRI does not end .AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the the product(s)listed on this Certificate ertified ratings are valid only for models and configurations listed in the unauthorized alteration of data listed on this Certificate.C directory at www,ahridirectorY�Org. n nd CONDITIONS 3 a'a , TERMS AND eminated; This Certificate and its contents are pr,oprietary products of AHRI.This Certificate shall only be used for individua perso confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;dis,- AM entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING. &REFRIGERATION INSTITUTE personal and confidential reference. CERTIFICATE VERIFICATION n this certificate can be verified at www.abridirectory.org,click on"Verify Certificate"link we make life.better" The information for the model cited o date on which the certificate was issued, ­­­­­..............--­­­­_ and enter the AHRI Certified Reference Number and the 1303731G4449372074 which is listed above,and the Certificate No.,which is listed at bottom right. CERTIFICATE NO.: Q2014 Air-Conditioning,Heating,and Refrigeration Institute