Loading...
631 Begonia St 2014 HVAC n, CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD j M7 ATLANTIC BEACH, FL 32233 tr.> INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000231 Date 2/19/14 Property Address . . . . . . 631 BEGONIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -------------------------------------------------------------------- Application desc 2 TONS 22KBTUS ------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- MORELAND PETER W OCEAN STATE HEAT & AIR, INC. 1510 4RD AVE N 1476 ATLANTIC BLVD. JACKSONVILLE BEACH FL 322502744 NEPTUNE BEACH FL 32266 (904) 249-8251 ------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . Permit Fee 91 . 00 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/18/14 ---------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 -------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 FD Ph(904) 247-5826 Fax (904) 247-5845 I OB ADDRESS: ( ee—V 0_ J PERMIT# # PROJECT VALUE $� ARI 5.212.5-5z -REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity_�_ BTU's Per Unit:60U Seer Rating Duct Systems: Total CFM REQUIRED SIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) WE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or at. The permit does not give authority to violate the pro isions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name Phone Number 4echanical Company C- I't- > -f. / Office Phone -� i' Fax g�� / ,�'L/ Cit State 'ti "Lip �� 'o. Address: / NT(Vol ✓ _ _y_ ,icense Holder(Print): _- ~� State Certi ica n/Registration#1L � t � Jotarized Signature of Licen ivYVETTE P.M LES Before m y of 20 NOTARY P IC STATE OF FL ature of Notary Public -- Comm#EE879174 Expires 3/2/2017 &AIM CERTIFIE Certificate of Product R AHRI Certified Reference Number: 5212331 Date: 2/18/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: PH13NB024 Indoor Unit Model Number: FB4CNF024 Manufacturer: PAYNE HEATING AND COOLING Trade/Brand name: PAYNE HEATING AND COOLING Series name: PAYNE PH13 Manufacturer responsible for the rating of this system combination is PAYNE HEATING AND COOLING Rated as folows in accordnce 8 fo inand Heat Pump IEquipment ands l subject to verification cat on of rating ac cu acyrbynAHRI-sponsored,indepe pendent,Air-Source Standard third party testing: Cooling Capacity (Btuh): 23400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 22000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 13000 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated; AM entered into a computer database:or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING, personal and confidential reference. 8,REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link „ah i:rc x r c r and enter the AHRI Certified Reference Number and the date on which the certificate was issue ....._ ...... which is listed above,and the Certificate No.,which is listed at bottom right. 130372160610473189 CERTIFICATE NO.: 02014 Air-Conditioning,Heating,and Refrigeration Institute