Loading...
1600 Selva Marina Drive (New ABCC Building) 2013-2014 Documents S!.sL'1r CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD jATLANTIC BEACH, FL 32233 IL E Cu" PY INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003848 Date 2/10/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description COMMERCIAL NEW CONSTRUCTION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5732911 ---------------------------------------------------------------------- Application desc NEW AB/SELVA CC BUILDING ------------------------------------------------------------------- Owner Contractor SELVA MARINA C OUNTRY-f Lt COPY RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . ASSEMBLY Flood Zone . . . . . . . . ZONE AE -------------------------------------------------------------- Permit . . . . . . COMMERCIAL NEW Additional desc . . Permit Fee 12146 . 00 Plan Check Fee 6073 . 00 Issue Date . . . . Valuation . . . . 5732911 Expiration Date . . 8/09/14 ------------------------------------------------------------- Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . A sewer cleanout must be installed at the property line . Cleanout must be covered with an RTl concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ------------------------------------------- 11sst� PERMIT 9�OV1F9�LY IN ACCORDANCE WIT+I ALL•CIT1SJF'TALARP' � B�R �AACES AND THE FLtf&Ac 19 BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 � f3 Page 2 Application Number . . . . . 13-00003848 Date 2/10/14 ------------------------------------------------------------------- Other Fees . . . . . . . . . DEV REVIEW-COMMERCIAL/IND 100 . 00 STATE DBPR SURCHARGE 182 . 19 UTIL REV COMMERCIAL BLDG 75 . 00 WATER CROSS CONNECTION 200 . 00 --------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ------- Permit Fee Total 12146 . 00 12146 . 00 . 00 . 00 Plan Check Total 6073 . 00 6073 . 00 . 00 . 00 Other Fee Total 739 . 38 739 . 38 . 00 . 00 Grand Total 18958 . 38 18958 . 38 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ±} ATLANTIC BEACH, FL 32233 l INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003848 Date 2/18/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description COMMERCIAL NEW CONSTRUCTION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5732911 ---------------------------------------------------------------------------- Application desc NEW AB/SELVA CC BUILDING ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- SELVA MARINA COUNTRY CLUB RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . ASSEMBLY Flood Zone . . . . . . . . ZONE AE -------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc INSTALL 80 FIXTURES Sub Contractor AMERICAN PLUMBING CONTRACTORS Permit Fee 615 . 00 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/17/14 --------------------------------------------------------------- Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed at the property line . Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS PERMIT-IS-APPROVED-ONUV IN-Afe0 2DANCE-WtTH-Att Vrff-0E-Ac7'tAN- C BLrACR-URDINANCES AND THE MUMS ------- BUILDINcCq9RM)-- Fees STATE PLBG DCA SURCHARGE 9 . 23 � Jai CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J - ATLANTIC BEACH, FL 32233 _ INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00003848 Date 2/18/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE PLBG DBPR SURCHARGE 9 . 23 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 615 . 00 615 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 18 .46 18 .46 . 00 . 00 Grand Total 633 . 46 633 .46 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION L CITY OF ATLANTIC BEACH G 800 Seminole Rd Atlantic Beach, FL 32233 / Ph(904) 247-5826 Fax (904) 247-5845 ii (� .TOB ADDRESS: 1�pUU mel-V-6 (V t Afti� PERMIT V NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory �'� Water Heater Other Fixtureshlq,N� , I� Water Treating System RE-PIPE: S TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name U 6 ou Phone Number Plumbing Company f ov"AAJ, Nu r»(0 l 0 Office c�/,b Fax �� 9Y5�y Co. Address: 7 26 ARI—A7 City 0 State Zip License Holder(Print): A�' �H C� State Certific egistration#zre-p�6Y Notarized Signature of Lic e Holder i-" qL00 J7 L6 S1 Q 26—Q :� JENNIFER nUER Befor is y of 20 := MY COMMISSI N Y FF 011480Dd� • •A EXPIRES: Signatu of Notary Public Bonded Thru Notary Public underwriters 1 CITY OF ATLANTIC BEACH s) 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 i3 �► Application Number . . . . . 14-00000223 Date 2/18/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PLUMBING FOR FITNESS CENTER ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SELVA MARINA COUNTRY CLUB AMERICAN PLUMBING CONTRACTORS 1600 SELVA MARINA DR 5720 ARLINGTON RD ATLANTIC BEACH FL 322335616 JACKSONVILLE FL 32211 (904) 591-5380 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . INSTALL 51 FIXTURES Permit Fee . . . . 412 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/17/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE PLBG DCA SURCHARGE 6 . 18 STATE PLBG DBPR SURCHARGE 6 . 18 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 412 . 00 412 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 12 . 36 12 . 36 . 00 . 00 Grand Total 424 . 36 424 . 36 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) /247-,5� ,4 822�6 Fax (904)247-5845 .TOB ADDRESS: &,,00 6 -K1rY+ PERMIT# NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE oFFIXTURE QTY TYPE oFFIXTURE QTY Bathtub Septic Tank&Pit _ Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan ) Drinking Fountain Slop Sink / Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** SIRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other law regulation construction or the performance of construction. Property Owners Namet u AJ7 L one Number Plumbing Company nn wl-V Z 0 Office Phone S Fax 9 Co. Address: /T��iti °N City State '7l- Zip J? o'? �( License Holder(Print): L� �,fi7Z4__ State�C�ert' ation/Registration#.Z Notarized Signature of Licen e der Before mf N20 Leondedd LA R11480;i e FR, `. derwriters k C M.v . i L i f Wr - �' Loe FEB 1 X 2014 •. No/�4 2014 '.1. I s � * MCVEIGH&JAANGUM STATE OF DENGI N E E R I N G - INC R 1 ��.�� N , FEB 1 2014 THRESHOLD BUILDING "'�a,;r�4�NA�l��EN, STRUCTURAL OBSERVATION PLAN By 3-&q ' Atlantic Beach Country Club Atlantic Beach,FL 1. SUMMARY A. In compliance with Florida Statues, the Owner will employ a Special Inspector registered in the State of Florida to observe construction of the structural components of the Atlantic Beach Country Club. The project consists of two-story country club. 2. RESPONSIBILITIES OF" iE SPECIAL INSPECTOR A. The Special Inspector will be responsible to the enforcement agency and will report his observation results in accordance with current governing Florida statutes. B. The Special Inspector Is responsible for observing that the construction of the structural system complies with the Official Conlmct,Documents. Official Contract Documents are defined as the permitted plans, addenda,and the specie)cations with all amendments thereto,and this Structural Observation Plan. C. The Special Inspector may use a representative to perform the work. The Special Inspector utilizing Authorized Representatives shall insure the Authorized Representative is qualified by education or licensure to perform the duties assigned the Special Inspector. The qualifications shall include licensure as a Professional Engineer or Architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;or registration as building inspector or general Contractor. The use of a representative shall be in compliance with Florida Statutes. The Special Inspector shall be in responsible charge of the work of the Authorized Representative, including reviewing reports and spot checks. The Special Inspector must pr zonally visit the site at points during construction which he deems key to the inspection program. D. The Special Inspector his Authorized Representative will visit the project site as required by the construction activity t( erve the various structural elements during the progress of the work E. The Special Inspector�,iill report observations of materials,workmanship or other features of construction deviating from the requimments of the official contract documents. Guidelines for observations covering specific areas of construction are listed herein. F. Quality control inspections and testing by an independent testing laboratory are required by the project specifications for some structural elements and will be available to the Special Inspector to supplement his own observations.These reports may include,but are not limited to;soil testing,concrete testing and steel connection testing. G. The acceptance of any structural component by the Special Inspector in no way relieves the Contractor of responsibility for complying with the requirements of the contract documents. H. Neither the Special Inspector nor his Authorized Representative shall make any design decisions or direct the Contractor to deviate from the approved contract documents. Any deviation from the approved contract documents shall be brought to the attention of the Contractor in a timely manner,so as to avert any undue STRUCTURAL • MECHA'; .i1', • ELECTRICAL • PLUMBING • FIRE PROTECTION • TECHNOLOGY 913:+K.G.Skinner Parkway • Jacksonville,Florida 32256 (904)Is i200 • Fax(904)636-6770 - mail@mcveighmangum.com MCVEIGH&MANGUM E N G I N E E R I N G • I N C expenses. If the Contractor corrects any deviation to the satisfaction of the Special Inspector, no further action is necessary. If the deviations are not corrected to the satisfaction of the Special Inspector,they shall be brought to the attention of the Structural Engineer of Record and the enforcing agency. 1. The Special Inspector shall institute quality assurance procedures to include,but not be limited to,requiring unscheduled visits, utilization of relevant check lists, use of a Site Visit Report and insuring that the Inspector or the Authorized Representative is at the project whenever so required by this plan. J. The Special Inspector will maintain a written record of threshold building observation activities and will render signed and sealed reports promptly to the Building Official with copies to the Owner, Architect of Record,Structural Engineer of Record and the Contractor. Individual reports may include any or all of the following: 1. General report on construction progress. 2. Weather conditions. 3. Other personnel present during the site visit. 4. Detailed check-off reports on specific areas. 5. Reports of the corrections of deficiencies previously noted. 6. Special test reports,welders'certification,sketches or other supplemental data. K. In addition to the report content requirements noted in section J, reports shall comply with any specific submission requirements, where applicable, of the City/County, or any other authority having local jurisdiction. L. At the completion of all structural work and after the correction of all deficiencies, the Special Inspector shall submit a signed and sealed statement to the Building Official conforming to Section 553.79 Subsection 7(a)Florida Statues. Copies will be sent to the Owner,Architect of Record,Structural Engineer of Record,and Contractor. M. This plan allows for general and specific items of concern. It does not limit the Special Inspector to only items listed. The Special Inspector's judgment must prevail on items not specifically covered. 3. RESPONSIBILITIES OF THE CONTRACTOR A. The Contractor shall furnish the Special Inspector, and keep current, a schedule of construction. The Contractor shall notify the Special Inspector 24 hours prior to the need for a site visit. The Contractor shall not place concrete or w& zr any work needing observation prior to observation by the Special Inspector. The Contractor shall make all areas available and safe for observation. B. The Contractor shall furnish all relevant test reports to the Special Inspector. These reports include,but are not limited to: 1. Soil testing. 2. Concrete testing. 3. Steel connection testing. C. The Contractor shall provide to the Special Inspector a copy of each approved submittal related to structural systems, materials and components for use in verifying proper construction. Such submittals shall include,but are not limited to,the following: 1. Contract documents,including all revisions. 2. Concrete mix designs and test results. 3. Concrete reinforcing steel fabrication drawings. 4. Structural steel fabrication drawings. Atlantic Beach Country Club Page 2 of 4 Structural Inspection Plan 02/11/14 MCVEIGH&1MMNGUM ENGINIERI NG - INC D. All submittals provided to the Special Inspector shall bear the stamp and initials of the Contractor and the Architect or Engineer of Record. 4. BUILDING DESCRIPTION A. The project consists of two-story clubhouse. 5. SPECIAL INSPECTOR'S OBSERVATIONS I The contract requirements for this project are contained in the Official Contract Documents. The following guidelines should be used in conjunction with a careful study of the Official Contract Documents. A. GENERAL 1. Review the Official Contract Documents to be sure that they are approved and available before the start of any phase of the structural work. 2. Observe that all tests,sampling or reports have been completed before finished work is covered and no longer capable of being inspected or tested. 3. Observe the repair and treatment of areas containing defective work. B. FOUNDATIONS 1. Prior to the placing of reinforcing in footings, observe, by reviewing the testing reports, that the required density tests have been made. 2. Observe the placement and size of anchor bolts and/or dowels. 3. Observe size,spacing,number and clearance of reinforcing. C. STRUCTURAL CONCRETE General 1. Observe that all structural embedded items are in place as shown on Official Contract Documents. 2. Before placement of concrete slab on grade, observe proper subsurface conditions, vapor barriers, reinforcing and size and location and formwork for construction joints,including joint locations. Reinforcini2 1. Observe that reinforcing is placed in accordance with approved shop drawings and latest Official Contract Documents: Concrete 1. By reviewing test reports, observe that all concrete delivered is of an approved mix design and adequate records are being maintained by testing lab. 2. Observe that all minforcing and formwork has been installed and all necessary corrections made before placement of concrete. D. STRUCTURAL STEEL, General 1. Observe the steel,with the plans and specifications. Steel Joists 1. Observe the steel joists for their depth and spacing and connections. Metal Deck 1. Observe the steel deck gauge, edge support, welding pattern, welding washers and touching welded areas with paint. Atlantic Beach Country Club Page 3 of 4 Structural Inspection Plan 02/11/14 MCVEIGH&MANGUM ENGINEER ] N G • INC E. PRE-ENGINEERED TRUSSES General 1. Observe that the spacing of trusses conforms to the structural and approved shop drawings. 2. Observe that the permanent bracing conforms to the approved engineered shop drawings. 3. Observe that the truss tie-down types are as specified,the attachments are complete and conform to the contract documents and approved engineered shop drawings. 4. Observe truss-to-truss connections conform with the approved engineered shop drawings. 5. Observe that the roof decking thickness and attachments conform to the construction documents and approved engineered shop drawings. F. WOOD General 1. Observe member sizes and spacing are as detailed on official contract documents or as otherwise approved. 2. Observe nailing, strapping and other connections area as detailed on the contract documents or as otherwise approved. i Atlantic Beach Country Club Page 4 of 4 Structural Inspection Plan 02/11/14 f "'Jiisjr January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road FILE Atlantic Beach, FL 32233 �P RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1:30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/1/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniakCacoab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 City of Atlantic Beach APPLICATION NUMBER s r � Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 .�+ G 1 Phone (904)247-5826 • Fax(904) 247-5845 17 E-mail: building-dept@coab.us Date routed: � = City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ���Vd- f Ci'�i7;Fiure Department review required Yes No Applicant: ning Zoning , e�dminis ral Project: /'V L lic Works lic Utilities'- 1 f a-,, 0�6 A_—n-f r �/ lic Safety/ Services �Iu6 Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 9042558559 JFRD—PLAN REVIEW 03:04:44 p.m. 02-03-2014 1 /1 City of Atlantic Beach j • Building bepartment APPLICATIpN:IVUMB�R::-`;: 1 800 Seminole Road ( (1"a,be.�ssigi�ed.by ttie Buildiny:Departmen " } r Atlantic Beach,Florida 32233 5445 �_L ::'` Phone(904 247-5826 • Fu(904) 7-5845 a E-mail: bur'lding-deptQcoab.us Qate:routed:< City web-site' t►ttpJlwww.coabus I f APPLICATION RE I �IEW AND TRACKING FORM Property Address: I ' Department review re uired Yes FNO BuIkIIn Applicant: �, Planning&Zoning { Tree Administrator Project; A Public Works Public Utilities L�1� Pu Fire Services 1 Other Agenc� Review or lull it Ri 1,quilred Review or Receipt Date i of Permit Verified I9 Florida Dept o�Frlvironnleratar Prritecdo Florida Dept,olTranspbrtarx:;� St.Johns RiverWater Management Di ct Army Corps of Engineers I Division of Hotels and Restaurants: Division of Alco olio Beverages and Tob' eco Other: I APP KATION STATUS Reviewing Department Fi' it Review: QApp ved. Denied. (Circle ori.) Comments: it BUILDING ; I PLANNING&ZONING I i I Reviewed by: Date: TREE ADMIN. I Second Revic y. QAp ved as r ised, []Denied. PUBLIC WORKS Comments: / I PUBLIC UTILITIES 1 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ppr ved as revised. ❑Denied. Comlments: i . Reviewed Date: 3 Reviscd 05/14109 i r f CITY OF ATLANTIC BEACH s� PUBLIC UTILITIES 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: 2/10/14 (Revision 2) Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Family New Water Tap(s) & Meter(s)_Existing 2" Meter Meter Size(s)_q" New Irrigation Meter Upgrade Existing Meter from to (size) New Connection to City Sewer Existing Name: RPC General Contractor -Pete Rodrigues Applicant Address: _248 Levy Rd. City: Atlantic Beach State: FL Zip: 32233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge $ for ABCC. Sewer System Development Charge $ Water Meter Only $ The existing 2"meter will be used. Water Meter Tap $ Sewer Tap $ — There will also be a 6" fireline meter Cross Connection $ 200 installed–no impact fees for that Other $ meter. TOTAL $ $ 200 (notes) APPROVED: Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED CITY OF ATLANTIC BEACH PUBLIC UTILITIES '-� 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 r�J1119r (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST N Q Date: 2/10/14 (revised) Project Address: 1600 Selva Marina Dr. ,' No. of Units: 1 Commercial X Residential Multi-Fami New Water Tap(s) & Meter(s)_Upgrade meter for clubhouse & amenitie Meter Size(s)_ i New Irrigation Meter Upgrade Existing Meter from ' to 3" (size) i New Connection to City Sewer Existing Name: RPC General Contractor -Pete Rodrigues Applicant Address: _248 Levy Ru. City: Atlantic Beach Slate: FL Zip: 3 X233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY TAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge 5 324 for ABCC. Based on new 3"meter, Sewer System Development Charge 18,913 upgraded from 2"meter. Water Meter Only $ Water Meter Tap $ There will also be a 6" fireline meter Sewer Tap $ installed—no impact fees for that Cross Connection $ 200 meter. Other $ Water=(3")$11,400—(2")$6,076=$5,324 TOTAL $ $24,437 Sewer=(3")$40,500-(2")$21,587=$18,913 (notes) APPROVED: Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED ii`Lc� y;,L G� .l v� iz11 GV LV rY'111.1P,1V1J ijur� 1CLL.L'1Y1 CITY OF ATLANTIC BEACH PROGRAM BP820L -------------•-------------------------------------- ------------------------ APPLICATION NUMBER: 13-00003848 1600 SELVA MARINA DR FEE DESCRIPTION AMOUNT DUE STATE DCA SURCHARGE 182 . 19 DEV REVIEW-COMMERCIAL/IND 100 . 00 PLAN CHECK FEES 6073 . 0 COMMERCIAL NEW 12146 . 0 STATE DBPR SURCHARGE 18219 / SEWER SDC-SYSTEM DEV CHG 1891 . 00 ✓ IV, UTIL REV COMMERCIAL BLDG 5 . 00 WATER CROSS CONNECTION 00 . 00 WATER SDC-SYSTEM DEV CHG 324 . 00 ✓ TOTAL DUE 3195 . 38 Please present this recei t to the cashier with full payment . � 5 K"J i g CITY OF ATLANTIC BEACH c �-� PUBLIC UTILITIES '•� - " 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST eettrbb Date: 2/10/14 (revised) Project Address: 1600 Selva Marina Dr. No. of Units: 1 Commercial X Residential Multi-Family New Water Tap(s) & Meter(s) Meter Size(s)_ New Irrigation Meter Upgrade Existing Meter from 2" to 311 (size) New Connection to City Sewer Existin Name: RPC General Contractor -Pete Rodrigues Applicant Address: _248 Levy Rc;.. City: Atlantic Beach S- ate: FL Zip: 32233 Phone Number: 241-4416 Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# 13-3848 New clubhouse and other buildings Water System Development Charge $ 5,32=4 / for ABCC. Based on new 3"meter, Sewer System Development Charge $_18,913_ upgraded from 2"meter. Water Meter Only $ Water Meter Tap $ There will also be a 6" fireline meter Sewer Tap $ installed—no impact fees for that Cross Connection $ 200 meter. Other $ Water=(3")$11,400—(2")$6,076=$5,324 TOTAL $_$24,437 Sewer=(3")$40,500-(2")$21,587=$18,913 (notes) APPROVED: Donna Kaluzniak 2/10/14 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED 1 C,� lJ� CITY OF ATLANTIC BEACH \ s11 s PUBLIC UTILITIES 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: 12/20/13 Project Address: _1600 Selva Marina Dr. No. of Units: 1 Commercial X_Residential Multi-Family New Water Tap(s) & Meter(s) New meter for clubhouse & amenities_ eter Size(s)_2:L New Irrigation Meter Upgrade Existing Meter from (size) New Connection to City Sewer X Name: RPC General Contractor -Pete Rodregues Applicant Address: _248 Levy Rd. City: Atlantic Beach State: FL Zip: 32233 Phone Number: 241-4416_Cell Number: Email Address Fax: Signature: (Applicant) CITY STA F USE ONLY Application#_13-3848 New clubhouse and other buildings Water System Development Charge $ 11 0 for ABCC. Based on 3"meter. Sewer System Development Charge $ 4 500_ Water Meter Only $ There will also be a 6" fireline meter Water Meter Tap $ installed—no impact fees for that Sewer Tap meter. Cross Connection 200 Other $ TOTAL $_$52.100_ (notes) APPROVED: Donna Kaluzniak 12/20/13 (Utility Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED Graham, Shirley From: Kaluzniak, Donna Sent: Monday, February 10, 2014 11:04 AM To: Graham, Shirley Subject: 1600 Selva Marina Dr2 Attachments: 1600 Selva Marina Dr2.docx Shirley, here is the revised Water/Sewer fee schedule. Per City Code, when upgrading from one size meter to another, we take the fees for the larger meter and subtract what would be the fees for the smaller. Thanks, Donna 1 Graham, Shirley From: Kaluzniak, Donna Sent: Monday, February 10, 2014 11:41 AM To: Pete Rodrigues Cc: Graham, Shirley; Walker, Jennifer Subject: RE: Utility fees-ABCC Attachments: 1600 Selva Marina Dr2.docx Pete, will do. Jenny/Shirley - per Pete's email below - ABCC will use the existing 2-inch meter instead of upgrading to a 3-inch meter for the clubhouse. We only need to charge the $200 cross-connection inspection fee. - Donna Donna Kaluzniak, Utility Director City of Atlantic Beach 902 Assisi Lane Atlantic Beach, FL 32233 (904) 270-2535 dkaluzniak(@coab.us -----Original Message----- From: Pete Rodrigues [mailto:Pete(@rpcgc.com] Sent: Monday, February 10, 2014 11:34 AM To: Kaluzniak, Donna Subject: Re: Utility fees - ABCC Use the existing 2" please Pete Rodrigues, President RPC General Contractors, Inc. > On Feb 10, 2014, at 11:32, "Kaluzniak, Donna" <dkaluzniak(@coab.us> wrote: > > Pete, do you mean if you keep just a 2" meter instead of a 3" meter? - If so - there would be no additional water/sewer fees (fees are based on meter size). > Or do you mean have the 3" plus a 2"? Which would be the amount I originally (mistakenly) had on the form for a new 3" meter. - Donna > -----Original Message----- > From: Pete Rodrigues [mailto:PeteOrpcgc.com] > Sent: Monday, February 10, 2014 11:27 AM > To: Kaluzniak, Donna > Subject: Re: Utility fees - ABCC > Another question would be . . . What would the fees be if we keep the existing meter . . . The Developer ( my boss) will want to know > Thanks 1 > Pete Rodrigues, President > RPC General Contractors, Inc. >> On Feb 10, 2014, at 11:24, "Kaluzniak, Donna" <dkaluzniak@coab.us> wrote: >> Pete, I sent Shirley a revised form. >> Per our City Code, we must subtract the fees for the existing 2" meter from the fees for the new 3" meter. >> My apologies - I filled out the form as if it were a new meter vs. an upgrade. >> Here is the correct fee. Thanks, Donna >> Donna Kaluzniak, Utility Director >> City of Atlantic Beach >> 902 Assisi Lane >> Atlantic Beach, FL 32233 >> (904) 270-2535 >> dkaluzniak@coab.us >> -----Original Message----- » From: Pete Rodrigues [mailto:Pete@rpcgc.com] >> Sent: Monday, February 10, 2014 11:20 AM >> To: Kaluzniak, Donna >> Subject: Utility fees - ABCC >> Donna >> While we work out the utility fees for the ABCC . . . Can we at least release the building permit and put a hold on CO until paid . . . Please let me know >> Thanks >> Cell= 545-5911 if you need to reach me >> Pete Rodrigues, President >> RPC General Contractors, >> <1600 Selva Marina Dr2.docx> 2 R FILE C Florida Energy Efficiency Code For BuldingConstruction EnergyGauge Summit® Fla/Com-2010, Effective Date- March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: 13093 Description: Atlantic Beach Country Club Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Exercise Center Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(26 1000) Conditioned Area: 3959 SF Conditioned&UnConditioned Area: 3959 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 9.2 If different,write in: N�1111111II IIt111//IIIry4 Y4 i,N • 0.4028 _ e • STATE ••'��. `f lrllfill}Illi".1:14�t1�1�` EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 1 of 8 qtr ' Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 2,064.0 2,465.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 8 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Michael Kratky Building Official: Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify(`)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 129.30 193.70 $2,064 $3,081 ELECTRICITY(MBtulkWhl$) 129.30 193.70 37877 56742 $2,064 $3,081 AREA LIGHTS 21.30 44.50 6229 13038 $339 $708 MISC EQUIPMT 19.30 19.30 5645 5645 $308 $307 PUMPS&MISC 0.30 0.30 73 75 $4 $4 SPACE COOL 53.80 53.50 15775 15672 $860 $851 SPACE HEAT 7.00 17.80 2060 5222 $112 $284 VENT FANS 27.60 58.30 8095 17090 $441 $928 Credits Applied: None PASSES Passing Criteria=2465 Design (including any credits)=2064 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 67% EnergyGauge Summit®Fla/Com-2010-Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File:FL_3ACKSONVILLE_INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light 1 Main entries Yes 30.00 30.0 900 600 Ext Light 2 Other(doors)than main entries Yes 20.00 12.0 240 120 Ext Light 4 Walk way less than 10 feet wide Yes 1.00 83.0 83 240 Ext Light 5 Canopies(freestanding,attached Yes 1.25 800.0 1,000 135 and Overhangs) Tradable Surfaces: 1095 (W) Allowance for Tradable: 1978.1 (W) PASSES All External Lighting: 1095 (W) Complicance check includes a excess/Base allowance of 600.00(W) Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File: FL JACKSONVILLE INTL ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance 141 5 Corridor 54 1 1 PASSES 142 6 Toilet and Washroom 271 2 1 PASSES 143 10,012 Laundry-Washing 150 1 1 PASSES 144 5 Corridor 54 1 1 PASSES 145 6 Toilet and Washroom 271 2 1 PASSES 009 3 Storage&Warehouse-Bulky 58 1 1 PASSES Active Storage 011A 1 Electrical Mechanical Equipment 50 1 1 PASSES Room-General 150 12 Lobby(General)-Reception and 166 1 1 PASSES Waiting 151 8,001 Exercise Area(Exercise Center) 755 1 1 PASSES 152 6 Toilet and Washroom 261 2 1 PASSES 153 6 Toilet and Washroom 261 2 1 PASSES 154 8,001 Exercise Area(Exercise Center) 1,185 1 1 PASSES 160 25,001 Sales Area 385 1 1 PASSES 161 3 Storage&Warehouse-Bulky 38 1 1 PASSES Active Storage PASSES EnergyGauge Summit®Fla/Com-2010,Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 5 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File: FL_3ACKSONVILLE_INTL ARPT.tm3) System Report Compliance OAU-1 Dedicated Outside Air Unit System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 14.40 12.23 14.40 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 0.57 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-8 Heat Pump Split System Constant Volume Packaged No.of Units System I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.00 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.30 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.63 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 6 of 8 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File: FL_JACKSONVILLE_INTL ARPT.tm3) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance finches] Runout? Temp [Btu-in/hr Thick lin] Thick lin] [F] SF.F[ Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 7 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ft2;all other products:0.3 cfm/ftz Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed FA Dropped Ceiling 502.3 Vented: seal&insulated ceiling.Unvented seal&insulate roof& Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in a construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control;Exterior photo sensor;Tandom wiring with I or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 8 of 8 El El o � L � O ..a L. F' N � N N U � L v `� Q = kn o pA U c7 W o c L � C FSI W W C Q U r- 0 u N N L L (� Vi V] 'A rA c L L N L M U C N v y G) L E a+ u c c c M O � ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El N 00 O 00 --� �!1 00 00 J ol M Vl ol M ^ 00 k/1 N O L 7 N f� 7 N `N V 00 0000 N N M z J F' CC y C\ O a, 7 00 .n N N Vi v'i n N N ^ f1 M ,,a O E^ C O a+ L V •G 67 SJ O O O O O O O M M O O M f7 O 3 d0�, O O O O O O O cel M O O M M O O 'Q cam. Q1 O C\ O Q\ O\ L V 00 00 00 ^ •�� C1 R e O 3 a� M U N M S O ti m CL V1 —Cd is C (D Nb�D E E a' C7 E E oCU °q d 0 W o o W t 'ca c �ca cn s a L i ca rig � o cz o ca aU Q U E ca A cz (z ¢ Q ^ "a y "0 'fl y .Q. •L Y ^�-. N •L ate+ (A C� V F' O 'p O 'p a'O X ca O U F� W U F- cnCo W W a caW UE F W U � Ca1 ° ° O ° E ° o N o N o 0 ca c - � C � a u N O c c J N Q N L _ r M V 7 O On VNl Q O O N N M en z N N N N 0 ❑ D 0 0 00 0 0 0 0 D0 00 0 0 0 M O 0 0 O O 0 0 O O O O 0 0 0 0 O O O O 0 0 O O 0 0 O O O O 0 0 0 0 O O O C13 iv Cd asm i0 id id 0 iC is cd iC c cd r r ��r �c�r rrCd ���rr ��r r ecd ��r I O N v) O 00 00 O O O It tn 7 O Vl oc l0 Vl h M M ,fir N V-, 00 00 kf) n) 00 00 00 V1 O W1 00 ke) 00 W) o0 tn kr) C `7 U N �t N M N N 't M h Cl) 1-0 n d d� V dD L 0q b4 d4 bA bQ b4 b4 by bQ b4 bA Oq 0q 0q b4 bU d4 by � cqs M U a c c c a c c a a c c c C7 C7 C7 0 0 0 C7 0 C7 C7 C7 C7 C7 C7 C7 C7 C7 V a 4CA CA c a c c c U U U U U U U U U p R 0 O 0 4) a �a a rn 011) to N M tn O cy r-I '""' N O u 6i d d d ai d d ai CJ u u u tC m cd cc 0: aC v cc 0 cc u Ix R cc u c> v cc u C. CC 0Y eC aC Ca CC r# R M c a a a a a a a a a a N ~ N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ C� N N N N N N N N N N N 6T. N N N N N N N N N N N Z d N N N N N N N ci AO O O O O O O O O O O U W '�• O O O u � d' � � •ct v v � � v � a o 0 0 0 0 0 0 0 0 0 0 0 o +� u O cau O 7 O (C :3u . L z w 3 z z w 3 0 c O M O M N W) y M 110 M 06 06 h V1 � ul ^ Q N M N M � x ra = = - ^ ^ - ^ ^ ^ ^ ^ ^ ^ o . U O OO O O O cn M M fn M CS CC 4a. O O O O O O M M M M M V W w O, Q, O\ ONm W4 d\ •--� bTD On ON M M M W 3 N M N M 00 O 00 O O a M M M M M M M M M M E M E O N O� N O N O� N O� N O� N N O N Q\ N ON N C1 N O O O O 'A O O O N O O O 'A FT N Q •-- Q ^ Q � Q ^ Q ^ Q Q ¢ ^� QQ �' Q 0 C. •L T T vu, � d 3 3 mcq3 3 3 3 3 3 M ItLl �n z ❑ ❑ ❑ ❑❑ ❑❑ ❑❑❑❑ ❑ ❑❑❑ ❑ �f 6J y 7 � _ 00 I:t o o oI: � rn � � '" � OC M N M �C �O M �o O M M O DD M M M IO NM M t �+FZ U4v, O ca � N N N N M N 'I It N V N N N 1�0 O � y � M Li O O O 10 IO IO ID ^ y 01, N N N �o N �.O N fV �o �D 'IT %.o � O C) U � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �? 0 0 0 w� o w� o o w� w� w� lr� V� w� v� N N N N N N N N N N N N N N N O C r1 Cj fl L U Q O O O O O O O 0 0 0 0 O 0 0 0 O Cl O O O O O O O O O O O O O u � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cl 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W— oo O O o O o 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 Cl 0 0 0 C. 0 0 0 0 0 0o CD CD 0000 0 000 0 i — o en v v, vq v, 't v! lr� w� w� v-i v 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 � c• b�0 0 0 0 0 0 0 0 0 O 0 0 0 a„ 2 Z Z 0 W c 0 a� a a a s a s a a a a a a U a a O c c c c c c c c c c c c c c c O a a a a s a s a a a a 4) a N V1 Vl V] VI VI V1 V1 V] y N V] y V1 VI G � N �D �D F' A N Q G, .0 '0 .0 C G C O C O C C O O C O 0 O c Ca 3 3 3 Q3 33 3r� n3 Q C5Q3 cryr c�� v o o t 0 0 0 0 0 0 0 0 3 X X X oo X oo X X oo X X X 00 oxo ) 'ct O It C) 'IT "It O O O O O O O N N N M N MCA N N M M M M M M M rJ N0 r3 3 ow z 3 � w z v� va 3 0 0 0 °J c o N M N N o c o N ❑ ❑ ❑ ❑ ❑ ❑ ❑ N N N N Vi kn kn kf-, N N M M Q Q CC v� v Ir, v, Cd O O C O A ^ L Q Gi L d u _ _ w U o o 0 0 N ^ o 0 00 Q 00 00 00 OC OC •-- U � p d c- C", O O O O 4••" Cir, — bL O O N V) L � J ta � L C DO 0 0 z z a w L L it L O O O O kn O N O O N O NCL Cl. O N O u 3 3 3 3 L J O O F O O O O O a via za Con a. C E N E C N y C rOi, N C vOi 3 N3 N C O O O N N N N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O O M M ti 1 6J Q � 00 o W W 0o p 0 o d ( V > a h 6) O O O �+ O O 00 O w i N lO ♦, O d O� Q O, O CD O W 4. G vi U V] R O o0 � U R O O p _ N v7 U M U O M M LL Z a �s C7 = C oo ta t' E L C c ca c ca d �' ce O ca CL ++ O =3a1 Ow f1 a� G O O o O fl O a�Ei ani � a�Ei ayEi y n o a E E cn o o a E E rn o 0 (U L L L O O b0 bq bb by C' �• •.• a N C N ZN M V In N M -It Wn M c ^ c ^ E E M El ❑ El El ❑ ❑ 0 E 0 00 o0 0 0 C) 0 0 �n = N M O O O O 3 cc z z E E E O y O O — y U_ U_ U U to O E E C F" O O O O O O O O O v n p, ci W o 0 w E _ W O 0 0 O O O C_ — ^ ^ u O iZ O O O O E O UO Z +�+ O N M O O oo 0 Z U v v, .� C 4�. r � aJ L O O O C cam..• L. V Cc oc N N W () m +r M o t wC a o v „ ~ a y K }+ — L — C7 3 W LL d N L c L U cC aco ? Y aj O ate+ C ,n y w U U i 5 °tea c -0a rA cn O a> 3 o v L L : cz CG CChi cz 33 o a L a) v U J J ^ L L O La� N O a) V� Lf) b •L 3 ca ti C.0 U U v s C s E E cz C15 cz c L cn pp cn on �, Q M O N 7 — r'1 M -- N M rt N CC ,_ 6J � O O O O O O O O O O\ O O O O O O1 O O u p N N N y O O O O O O O O O a� 0 0 0 y w o 0o O o 0 o c o0 0 U O O O M M O 00 O M M C Q � � O Cl O 00 O O 00 p O O O O O O O O � U " 0 0 O O C 0 0W) N OMO O o o o ^ o 0 0 0 0 0 ci a � 7 O M O O O N O O Q O CN 0 0 C7 Q O O O O M O O O O O OO O O O M O O Cl O N 00 00 M O� 00 O C [� M �D DD O O O O O 0 0 0 0 N p 'P4 G� GL O p O O O O O y y O y O In M O O C c O O ^ 0 Y w (,� LZ to o aw z 00 c� c a 3 ons 0 w0 �1 �" w ]c o H DQE- ami b � 2 ¢ a°i� " = � o � o ¢ .o • Ln c F QQ o a - emu cn < m :aw oc O O O O Y 3 G N NZt 000 N 'O s. V cG cYC cYC c� cYC id cYC id ca cYC ict G. O- f1 a. M 0 O N m fn a\ O O cC O O +•' 00 t 00 01 O 00 't O O O O Z M M N N ' N N c� W: C M 7 � Gz. SGT o c.: O T L O O O W L O O O 0 ee o 0 0 o 0 0 d _ � rz6 � Gti ee �«: ea %.: � N y U o N o U _ 0 0 o o > CA cc ee r••i a L ^ L Y Q U cq l = x 2, o = C O 00 00 CC Z N N N 00 R Z N V N M O N M U cu w � a o z ¢ z "' 0 N N � M Z O Z O N w T � u ` 0 ons o 0 0 0 0 0 0 0 0 0 o O o o O 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 o 0 0 0 0 0 0 0 L O O O O O O O O O O O O O O O CC w � Cyi CJ � o •'o = o c 00 N w O U 000 O w O O V O O O Z r O O O O F O cj y +' � u � u cc C W ee c N y U W O cc rq o 8 z c°'i cG u 8 Z v c u W va o a o c o a C7 c cc U r N U O O 00 Z Ln y C7 vaz 421, p aa, `L = ? H O c yW a O 3 CQ a C7 5 O u) CC � L N y O M N [� (� N CJ 2�1 cc Z o o rn N °^° o e Z o N o 000 °° o E u M L E �, N M 7 V1 r o0 cc R E O R O O M z z x o N N O 7 E 6 67 bL CC tE bll d C W M_ O N M N k c..S<.-wy.:'.�"MiYA1►.1:�f!iM"'h.1�.L FILE C iP t .. Florida Energy Efficiency Code For Building Construction EnergyGauge SummitO Fla/Com-2010, Effective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc• 13093 Description: Atlantic Beach Country Club Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Dining:Bar Lounge/Leisure Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(261000) Conditioned Area: 11138 SF Conditioned&UnConditioned Area: 11138 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 14.5 If different,write in: YAR/�°�. F • omay= • B7 0 .- i , u♦��i♦r/�i i{,fM �kf!�I F1��\^• flllllllll�lp►p1� EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 1 of 13 Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 7,668.0 8,029.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 13 I CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code y� Prepared By: Michael Kratky Building Official: Date: jo�-&3 Z Date: I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify(")that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL_ARPTAW) Building End Uses 1) Proposed 2) Baseline Total 481.90 630.80 $7,668 $10,036 ELECTRICITY(MBtu/kWh/$) 481.90 630.80 141216 184831 $7,668 $10,036 AREA LIGHTS 124.70 136.40 36529 39976 $1,984 $2,171 MISC EQUIPMT 83.80 83.80 24564 24564 $1,334 $1,334 PUMPS & MISC 1.00 1.20 304 359 $17 $19 SPACE COOL 179.70 186.30 52664 54576 $2,860 $2,963 SPACE HEAT 23.90 56.00 6993 16408 $380 $891 VENT FANS 68.80 167.10 20162 48948 $1,095 $2,658 Credits Applied: None PASSES Passing Criteria=8029 Design (including any credits)= 7668 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 76.4% EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 13 Project: 13093 Title:Atlantic Beach Country Club—Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light 1 Uncovered Parking Areas-- Yes 0.15 75,000.0 11,250 855 Parking lots and Drives Ext Light 3 Walkway less than 10 feet wide Yes 1.00 120.0 120 400 Ext Light 4 Special Feature areas Yes 0.20 21,000.0 4,200 520 Ext Light 5 Main entries Yes 30.00 6.0 180 30 Ext Light 6 Entry Canopies Yes 1.25 432.0 540 600 Ext Light 7 Other(doors)than main entries Yes 20.00 39.0 780 540 Ext Light 8 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 9 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 10 Canopies(freestanding,attached Yes 1.25 705.0 881 105 and Overhangs) Ext Light 11 Walkway less than 10 feet wide Yes 1.00 48.0 48 60 Ext Light 12 Building facades(by linear foot) No 5.00 58.0 290 120 Ext Light 13 Building facades(by linear foot) No 5.00 36.0 180 160 Tradable Surfaces: 3170 (W) Allowance for Tradable: 9994.279 (W) PASSES All External Lighting: 3450 (W) Complicance check includes a excess/Base allowance of 600.00(W) Ext Light 13-- 70W from the excess/Base allowance was applied to this item to comply EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 5 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL JACKSONVILLE INTL ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance 003 1 Electrical Mechanical Equipment 51 1 1 PASSES Room-General 004 1 Electrical Mechanical Equipment 75 1 1 PASSES Room-General 111 7 Food Service-Kitchen 1,500 1 1 PASSES 111A 6 Toilet and Washroom 46 1 1 PASSES 113 17 Office-Enclosed 104 1 1 PASSES 115 7 Food Service-Kitchen 120 1 1 PASSES 104 5 Corridor 158 1 1 PASSES 109 5 Corridor 57 1 1 PASSES 110 3 Storage&Warehouse-Bulky 77 1 1 PASSES Active Storage 119 8 Food Service-Leisure Dining 1,303 3 1 PASSES 119 8 Food Service-Leisure Dining 559 3 1 PASSES 116 8 Food Service-Leisure Dining 710 1 1 PASSES 105 17 Office-Enclosed 128 1 1 PASSES 106 17 Office-Enclosed 128 1 1 PASSES 107 17 Office-Enclosed 128 1 1 PASSES 100 12 Lobby(General)-Reception and 280 2 1 PASSES Waiting 101 12 Lobby(General)-Reception and 214 1 1 PASSES Waiting 102 17 Office-Enclosed 150 1 1 PASSES 103 12 Lobby(General)-Reception and 151 2 1 PASSES Waiting 117 5 Corridor 62 1 1 PASSES 118 9 Food Service-Bar/Lounge 182 2 1 PASSES 119 9 Food Service-Bar/Lounge 92 1 1 PASSES 120 9 Food Service-Bar/Lounge 659 2 1 PASSES 120A 3 Storage&Warehouse-Bulky 59 1 1 PASSES Active Storage 120B 1 Electrical Mechanical Equipment 74 1 1 PASSES Room-General 121 9 Food Service-Bar/Lounge 782 1 1 PASSES 122 25,001 Sales Area 578 2 1 PASSES 123 17 Office-Enclosed 182 1 1 PASSES 123B 3 Storage&Warehouse-Bulky 40 1 1 PASSES Active Storage 125 5 Corridor 30 1 1 PASSES 126 5 Corridor 48 1 1 PASSES 127 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 128 6 Toilet and Washroom 410 2 1 PASSES 129 5 Corridor 72 1 1 PASSES 129A I Electrical Mechanical Equipment 28 1 1 PASSES Room-General EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 6 of 13 130 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 131 1 Electrical Mechanical Equipment 25 1 1 PASSES Room-General 132 6 Toilet and Washroom 614 2 1 PASSES 135 5 Corridor 40 1 1 PASSES 136 5 Corridor 125 1 1 PASSES 137 6 Toilet and Washroom 232 2 1 PASSES 138 6 Toilet and Washroom 214 2 1 PASSES 124 1 Electrical Mechanical Equipment 38 1 1 PASSES Room-General PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 7 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL ARPT.tm3) System Report Compliance RTU-1 Packaged Roof Top Heat Pump System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 10.80 10.60 11.80 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.30 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-2A Heat Pump Split System Constant Volume Packaged No.of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHtJ-2B Heat Pump Split System Constant Volume Packaged No.of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 8 of 13 Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-3 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.70 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-4 Heat Pump Split System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria Rance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 9 of 13 i AHU-5 Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.70 10.60 12.00 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.56 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-6 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 16.00 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-7 Heat Pump Split System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date: March 15,2012 12/13/2013 Page 10 of 13 Air Handling Air Handler(Supply)- 0.39 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) DSS-1 Ductless Split System Heat Pump Constant Volume Air Cooled No.of Units Split System <65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 17.00 12.23 17.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 10.80 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club—Main Building Type: Dining:Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL ARPT.tm3) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 11 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance finches] Runout? Temp ]Btu-in/hr Thick]in] Thick]in] ]F] SF.F] Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 12 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge F1aCom attached y Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ftz;all other products: 0.3 cfm/ftz Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed rM Dropped Ceiling 502.3 Vented: seal& insulated ceiling.Unvented seal&insulate roof& IZI Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic FA control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in IJ construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat FA trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control;Exterior photo sensor;Tandom wiring 13 with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 13 of 13 L s. 'n oo rn n C F oc 4.4 L s � � u � oc z Q z ( a W Q C A � Nci 0. •� 6 00000Q w Z a" � o0000o w cr L L U N CA CA — _ M G � ^C w � � Y U v — �� t.:.• U L tj tn N N N N N N N M O 4V A- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El ❑ N N � 00 Mm M a0 7 fy 00 M C� C�ookf� 110 C\ Okn ^ M O 00 7 [ M vi V 7 O �' N � 00 � v N 00 F' d O O O ON O Q\ Q1 G1 L O O C O O 00 O O f.•� 00 O n kf) M CC ^ a� F. i:+ L _ O _ N 00 ,= O O O O O O M M M O O M M M M N M on y O O O O O O M M M v? v? M M M M 00 "D M M O 3 Ot O 'ct vl � � M M M 00DD Vr O O p\ 00 M N N .-. Z: � U a cn ° L Ste+ � O O O Cd E Cd E 5C a Q 4) W C) a o0 0 0 0 0 03 o E ^ E c� y ° �- O O O " . 03o° U U a- °o o °o 0 mwW Ww F- O w U U cnfba D rS, Qu D O O O a� U_ y >U> > V] N .Mi O Uct C. CA ca tom. cC cc p C o CA won c li o p o a`�i aUi a`�'i p ca is c c c O v'i, u a A ua �G a O w C7 F- L1 Q Q U d O d N M C O N N N N N 0 u N M 7 d � kn O O Q\ Q\ O O O d O O ~ ^ O N N N4w cw ^ a ^ M ti ^ O C N M N M N O N M Z N N N N r 00 a, .� e x ❑ ❑ 0E ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El ❑ ❑ ❑ ❑ M N O N M DD O 00 \000 M N O C� O 0 -r O O M M N [� N O N C) C) M O M �• O O m 0 [� O a1 M O [� v) M N + O O p O p Q1 p p O Q1 O O O O O O N N kn •cY oo r- O O 00 C O N 00 M M M M O O O O M O O O O O O O O O O O O O �? O O O O O O O O Cl O 4\ O C; p Q\ Q\ C\ C\ Q\ O\ C\ C1 M M v1 O r- p O\ r- 00 O lG IT O N 00 M N M 00 O\ N 00 O d: M 7 O� N 4 N M 00 v� ^ N N N N O M M vl O, 00 01, [- 10 l� N v1 N [� �O N N OMi N 7 N �O N N r-� '2 c\ t-� 00 N 6 ,� O 00 W' N N N N U C C N N N � N fC CC U U U O O O U O N C bD ti 33 w i� s. o 0 cn E U � d CC CYC �; G�1 0.1 0.1 c0 2d o R E W a) 0 � ; 3 � U y � ami C C ami � 'U 'U 'U> � •� � U C � •> L �(J V 1. con con con own d U E d a� d o o c ca o a 4) a a UU a L o 0 0 o Y o Ci E: o .°' '3 o O o ^ o o O Q 0 ^- o ° O o L o Q o Q' L o .� E � ct .a ca U u., U. U? � wwww O cnxU U CarxE- U Ww (� p: E o a on N CSC O N L V N = u ¢' U U ca O to O N ct y co c c L o ca W a 0- c ❑ C _ N 2 N 0 aUi3 U 6' a� •�, O O a� a� a� a� a� O rL a m aU � C7 a x > 3 C C C c N O N M N r- 00 O� O O O N N M mM N DD 01 � Cl M y y ~ y d N Q -T W) \0 n p N M N M 'IT v', V' M N N N N N c c c c 1, ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ — N n nco 0 0 o 0 0 0 O O O O O O O 00 N O" O O O O O O O O 7 ci � ca iz7 C O 0 O ccz Cd cid ccz cC 0 0 0 0 0 0 0 0 3 � `� `� � N c c (0; o; o, a, c a' 00 00 00 00 co co U Lf) 00 0c00 00 oc CA O en b = v E c J � a Cd c7 E E E O Q .2 a G O CC to to to bo bo tio th E O 0 o cd73 —CIZ o moo �0n X00 �0n �0n on on o cd 0 o o $ ❑ C7 C7 C7 C7 C7 C7 U qu U UCA H H W W a c i o °o E Y ? 0 $ 0 0Ln 0 o w o o 0 y U Y Y ZS —Cd cn O. v, a0i vi a0i W q 3 > CA U U xz xz xz a Q Qv 0o O O O c Z c C 0 0 N N CJ u u v u u M M M M ccnn a n a C a a n en n 00 as O •-� N C O .O. C en N N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O O O O OO O O O O O O O O O O C c c c c c c c c c c c c c c c O O O O O O O O O O O O O O O O —cz —cd —Cqs R _C5 —ci ct o a C c c C C c c c c G c c ❑ c c c c c c 0 0 0 0 0 0 0 O 00 0� 00 N O l� M 00 M N — n N -� �n oo O O O O O O O 00 00 0o O O 00 00 O \o M O \O M O Vl k!1 kn O �O ^ O N N Vr O\ ^- N zT kn N N N kf) N CL a 6J SSL 7 b�L Y bq Op Oq th OA Oq bq Oq d4 OA Oq 00 b4 bq b4 bq by bq bq bA bq OA OA tocu di by bA OA bA by b0 OA bA L L L L L L L L L L L L L L L L C C c c c C C C C C C C C c C C '�D1� r�rNr�� (Dr� V V V V V V V V V V V V U U U U U N y tici N N N N N 4.) U U U ti ti 'A O O O O O O yam„ i O O s0. c c O c c c 7 7 7 7 7 7 c aj di 4.) di ami ami ami ami ami o� ami p 4.) > vin >> > a a p > Ln o v O rig v� rn cis v� Wl rig tX 2 CC Z �: 2 rA cn r1 CG z r+ N M N M ^cw N M ^ O O O .-. N .-. C C C u v v N u v N u u v N u cii u u cC CC CC R R CC CC CC CC CC CC CC M a c a a c a a c a a a c/1 r c Vl VJ C/1 V] V] V1 U] Cn V] V1 C/� N rC. � .C. C rC. .C. C � .C. rC. � ►C. .C. rC. C M O N N N ^ a � � ❑ ❑ ❑ El [1 ❑ 0 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Z -a s -,a -a -a Z Z � Z - -a Z c c r- 0 O O O 0 0 O 0 0 O O O O O O O O O ccca a3 ° c a ° a e c ° cli Cd C-1c 0 0 o n o- " ao o o v 110 o okn c� 00 tl1 N N M M N M M — — In kn O Vl V1 kn O o kn 00 W) Cl) Cl) O ..r N b�0 7 CC b�0 L bA bA to bA bA 01,1 bA to to to to to bA to by bA bA .w Y -E .� 1� -Y -Y moi+ Y ^ a s a a a a a a a a a a s a a a a Cd ,VNr� ,�VNN Nrr�� .�\0II/..�� NdNNu 4' N 0 0 ,�Nrr�� '�NFI�S ,�N 0 V) 0 0 0 0 0 0 0 rr�� V V V U G G C 0 U0 L' U U U U S. 7�. p Ip. p 0 0 0 0 0 7 w w w w w w 0 4 c c � a c c A a A V 4.) 0 A 4) A C a Cn a rn CA a a vl a a a a rA a Cl) a Q as as h 00 ON O O O "I t� N Vl r, �O N � N � � N ^, N ,_, r N — N C G G N ei ei ei ei 5i ai ei ei ei ai N ei ci v v u u u u u u u u u u u u CC fR CC CO CC CC ad R CC CQ R CE RS M N lV N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ r O O O O O O O O O O O O O O O O � Z � � c c Z � � � � Z Z Z � c O O O O O O O O O O O O O O O O C> v) 0 0 0 0 0 kn o o o s �n W) O kn O Wn O kn O v) to O to O 00 O cci OD .cc U�', b�D bq bb bb bA bb w bA by by w W bAl by to to by d bU b1) bQ N N N N N N N U N N U N N U N N C C C C C C C C C C C C C C C N N N N N U U N U N N N U N N U 73 U U w w w w w w w aLn a a aCA a cn a Z 00 ON 00e4 eq en m en en en cq en cq O N .--� U C ci d 6� ci u u u c+ u u u u u ci cu u CC CC CE Cc CE R CC r r R R H s a a a a a a c c a a 1 VI V1 VJ C/1 VJ V] CA M N N C '~ i.r ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O d! N N N N N N N N N N N N N rl W N N N N N N N N N N N N N rl N N N N N N N N N N N N N ra M M M M M M M M M M ^ ^ W V1 to Vl N V1 V1 V1 wl V1 V1 lr� u fi. w o 0 0 0 0 0 o O o 0 0 0 0 M W) kn Ln kn In kn Vn In In In kn Q-1 «, o 0 0 0 0 0 0 o O o 0 0 0 C o 0 0 0 0 0 0 0 0 0 0 0 0 o +� U p? a L z w 3 w 3 3 z w0 z w ° z 0 C O O N O N N N N N n N C yy_ 00 O N O N N � O O L = rn 00 N N O O M O� h C � 3 s � ej O O O O .fir M M Mm M M M O CQ 4r O O O O M M M M M M M O u► i+ ON C� .--i �u L d C [� l� M � kr) O � 00 O 00 W! 4i 00 �D 00 ch �O V' �O 00 3 d N N M Cd cd id cd cd cd id cd cd td cd cd cd cd M M q M -�, M -�, M M .�., M fM M M ^ v O\ N O\ y 01 N 01 N O� N D\ N O\ N D\ N O\ N 11 N O\ N C1 N 11 N O� C O y 0 O N O O O O N O N O y 0 w O N O 'A O In O M N M N M N M N M M M N fM v' M N M `n A N eq N 4) M V) 3 ¢ cd ¢ ¢ ¢Cd cts Cd Cd c% 3 ¢ ¢ ¢ ¢ ¢ ¢ ¢ a oQz w � 3 CQW CQ � 3 =Qz w � CQz W � Cz N lel N N N N N � N N M N M — z00 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑ ❑❑ ❑ N N N N N N N N N N N N N N N N N N F N N N N N N N N N Q , ^ M M M M M M M M M M M v Wn Wn W� Wn Wn v� Wn W� = •4= N �n u d O O O O O O O O O W w O ^ O \O O O O O O O O O O Wn kn Wn N t: cri 0 3 z 3 z w z L O O O O O O �n �n O oo O O O 01 �O M kr) ao Q\ \p `O O vl O O N •-• V 7 Ok ' Z O O O O O O 3 � � = L o 0 0 0 0 0 vC> <= v v a O O M M M O O O O 3 = O O O (D O O O O M M M O O O O Q1 O ,-. r; C1 C1 O T Of O O M O v) 00 00 �D -•• wl [� 4=- D Q Q D w w 3T3 �, 3T3T3 � 3T3 �.3T3T �ca 0 Cd vi ca Cd as ca cd ' 16 M E M S M E M E ME" M E M E M E M E u N Q\ N u Cs N � N O, N ^ Q Q ^ Q M Q ^ Q ^ Q Q 2 Q M Q O O O O O O C C C C O C a 33 3 30° 3 3 0 L. N N 000 000 d >1 �' T cu N N N O 0 3 O N N N EN E N CA 3 3 � 3 3 3 v3 3 3 N M ` ^ N Cl) O ^ N Cl) 7 r.i C C C1 ❑❑ ❑ ❑❑❑ ❑ ❑ ❑ ❑❑ ❑❑ ❑❑ ❑ ❑❑❑ ❑ 0 00 O V) N M M O (D O O l- O O �O �O O O V) V) W� IIR lr� V) O O O O O O O M M M Cl r- l- O [- O O O O O v) N V) O V1 M M M V) IIR 110 ^ v) �R V) V) V) V) V'1 N N N N N N ^ N N N It 4 N NIct N N N N N O O O O O O O O O O Cl O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O_ O O O O O O O O O O O O O O O O O O O Cl i 11: kl� 11: 11: N 11: V' rf 7 1� � 7 �t : v) W� O O O O O O O O O O O O O 0 0 O O O O O E 7 O O O O O O O O O O O O C) O O O O O O O O O O O O O O O O O O O O O O O O O O O y� Cl O O O O O O O O O O O O O O O O O O O v, kr� 11: v, V, v, "I: "I: 't v qt v, q V kn a C) 0 0 C) Cl 0 0 o O o (=> 0 0 0 0 C) 0 0 0 0 0 0 0 0 0 0 0 0 0 ; ; ; o o ; ; o a s a a a a a v a a s a s o a a a a a a U V V C C C C C C C C C C C C C C C C C C C C L L L L L L L L L L L L L L L L L L L L Vl fA V] rrV-��I V] N to V1 N rrV-��1 V1 VI rr-n� Vl VI Vi V) VI !/ VI 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a L a a s L a a a a s a L a s a a s L L c o c C C o c C c c 0C C c a c 0 0 303. 3 33Q33 3 3 33 3Q3 33 3 33Q3 03 O OC C O d' O O C O C C O C 00 00 a a'kn N 00 a DD kn kn 00 �O �O a0 00 \O 00 a 00 'a O O H rte. O VX O O H 00 -00 O \10 O1.0 OXO C) cc cc ^ N 7 N M 3 3 3 N 3 N M Wz z 3 oz � 3 CC CC CC K CC CC CC CC CC CC CC M N N N � ❑❑ ❑❑ ❑ 11 El ❑ ❑ ❑ u y R 'V M n 00 V' r- C �. M N — — y � O C — R i Z ct k R v v N �� _ _ 47 U w J ct O t- O O) b C O O r i •-r V'i cli 'O (4 C, C, U O O O O rl (-I N N N rd (`1 O O v C) C) 0 0 0Ol (71 C oo wlo O O � 0 0 0 0 0 0 0 O 0 o O o v v vkq 0 0 0 0 0 0 0 x cc It L zzz z z N N N N N N N A 0 AV w w w w o vOi ai vOi vii vpi vOi cA y p N u Q Q O O O O O O 3 3 3 3 A 3 3 3 Q p O O M M � 3 � N 3 � � 3 � 3 ^ o za •� •—' � Q � Baa �' •-� N ti N C v� N clC N Q CN Q c 3 3 3 d3 3 N3 N M N N ❑ ❑ ❑ ❑ ❑ ❑ ❑ � ❑ _ 2 m m m a / \ \ % %% / j 2 � / § f f \ f f f In 2 cli k7 f f \ Q9 0 $ 7 � \ \ \ \ \ \ \ \ e9 \ c c c a e o 0 ® � u2 � R f00 \ \ / / 00 cq r « 3 — — — — J \ k / & § E \ _� o k \ $ % / q g \ $ \ � } t = _ � ® / � �7A k \ \ Q % $ ® _ @ \ \ \ \ \ \ \ � E ® § t b \ \ \ \ 0 \ In a ( \ / J J k JGn : % t % % 0 \ � o E r E - E r E � E r- E 00 E z b \ E ( ) ( ) ( ) w ( ) Q ( ) ( ) 00 ( k 3 § k N4 � N4cN < 2N4cN < @N < � w < ; N4 2 \ o en m M M M M M M M M M W O M M M M M M M C7 M M M M M M M M O O O O O O O O CZ G O O O O O O O O V O O R � � N o0 00 V1 00 M VC'I N 00 CN pMp N M GL1 _p O � R � � w O O, oo fll oc Vl � a rte+ tTD CN 00 m 06 rM n N N Gs7 a w R R R R R R R = R C mQ+ O N O O y O O O O O N O ca o ca o ca u co o cc o — n O vs., O v �.. O v i.. O v f.. O ci �n N rn N � N N N N N ti yr N -0 tQ V y R � O O O O O O O O O O O O O O O O Q pa y y y y N C rn M = ti C rn kn C 'n d O 'A O ti O d O ti y O N N N N N N N N ^ M 0 c 6J .-- d � d — d — CJM N '- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 0 0 0 0 0 z z z > o > o > o E rcd cd a R > R A O N O O U C O N O O U C O N O O 'ct y, C O O O O O O � •V � pp O � � M o �o �o Q+ •� ^ ri o �o �o 00 'u ,• m o 0 0 00 O O CC 'ia O O O 00 y O O 00 O O OO rA ++ O O O O V O O U O O C_Cd In In O O O C N O d N O) O C O N W) U oo O N M U O N M U Cn ce v) t— v'i U U U a, an a V o�n d a W E E aEi v) a�Ei E E aEcn i n CA o o E a�Ei `n o o cl E E cn o o s E E rn o o tb Ca w Q Q U x Q Q Q U Z Q Q Q U Q Q Q d M M rY •-- N M 7 �/'� N M 7 �n �-- N C. N � M ¢• C d U Q U d U ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ » - ^ - / \ \ S O O � ƒ / > @ > 2 @ 96. S _ / _ � � 7 2 / 2 & / 9 ^ / 6 b 2kn i" a $ & a o e $ / m \ � �o d a 3 o a 2 § \ \ c 2 § S 9 0 2 § \ \ c t § _ o / / [ \ a / / § a @ Q / kn v \ \ \ k / j CA § k k ( [ 2 co� z ow E ( E (( ( 2 2 \ e o o e e / / ® \ § § o / ® a ® ® E \ % & G •- z G \ •- z z & •- z z c z z ecc \ z E s •c •E o z z s •c •E 7 / / § 2 2 7 7 § 2 2 Q 7 \ § 7 ® U en \ ) § n Cl) - r § — m r "It kr) « e § § m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 y — O O � r y U O O 77 Q +' L W O � •a W O O O cr z .a cpl. po z z po U cd c:lUL u o Cl u v O ONOo 00 L «, c trj � v O p C r Cu U UC'A v O rIu LU c G. c ca � W o c L E `t cG Ch GL .Y ct G cA E E G V) E 0 o u Eto th cn c 2 > > •_ A L' cn C c 3 L O 'O .Y .Y O 4j C 01) G c=am' N C o c as M C ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ 0 0 0 0 O o 0 0 0 0 0 0 0 0 o a 0 0 0 0 k � � � z z x 0 0 0 0 0 0 0 0 0 0 0 �= U U U U U U U U U U U L L L L L L L L L L L E E E LLE E E E EE_ E_ E E_ jg 7F Cd CC CC CG (� C� fd fC CC CC Cd a � .•.. U U U U U U_ U_ _U _U U _U ^ L' E E E E E E E E E E E F" O O O O O O O O O O O 0 0 c E .E O o 0 0 0 0 0 0 0 0 0 0 0 M O N N O 00 M Z N F O O O O O 14000 000 O i • 00 00 \O c '� � N N O a -p •, U 00 N ^ O� N •-• l� N N •^I C/1 6� ta y .Ki OOIt rq (~ y ct �Fn C> G r _R 7 t � bin C. CL rl C7 "a C 0o d c c c t 4y- o c U — o � sono cu s Y /\ N L 'n' L L L N N V' O CC y .N O O O .i 4 4- cz Li, Ma O to eOncd L _ C,3 t -S 3 3cn 2 w o � o � o cc � 3 '3waa �° 0 0 x x u u -o 'd U U U N L 0 -0 b L L Cd c zz U U a+ 0 0 en en en en en en en en en en an Fa. Q � 3 w wwww w w w w w w O 3Q N z ^ N ar C, C M o 0 0 0 N M r- oo D\ ^ Z M M .f V. ❑❑❑❑❑ ❑ ❑❑ ❑❑❑❑ ❑ ❑ ❑ c o 0 0 Cl C, o C) 0 0 Cl 0 0 0 C p� s O O O O O p M O O O O O O .4• �" o00 ;0 u P6;01^ 0.9 O O _ 0 0 00 O O 00 V 7 C) 7 � p O O O O O O C 6. O O Q� V O V R R O L �y GL O d _ Lz. �t O O O N d O Cl O U O O NO O O O O O O C O ? O O O O O O O a, O O M v O Vl R Gz M O 0 0 ^ 110 O N 00 M O, oo rel N O vl O O M S 00 �"� _y L p N O O O O O O O O O N V a W � v C) p .S ci ca c O ca a O o ,a�, R� C o � 3a ZQ cC) Od O N tV3 b `n a W _ DwC7 ¢ W � a Q DC7 U IQ- o �n cq Y O O O O y O Cl O O O Y Y Y ^ R ca C �+ t- \D 00 o C N 7 00 O 00 N NCZ Y YC13 in. R O N m O N M O � M M Z 00 v'� p 0 0 0O O .. O a+ 00 O� 00 N O O O O Z ,N. M rR N t' C, N y _ U •O O u E u o o 0 0 0 0 0 0 o L � u _ w _ O � � O ar O V O u � CA � u r-I a W cd cc ca kn � z o ee c 0 3 m a M _ F b 00 p z00 K Z N R z O N O O N M � � •-- cC �, ^- N M d' in � � O O U y M ON �_ O M cc z p 00 O ,:2 o z o z z 0 N O � � M N 0 � CB � R w O K � N C L O O O O O O O O R R O O O O O O O O L �y C Z CC w � � o vNi 000 O O 'ch O v, � c N pa C7 x � z m � 4u °' O Lt O N CQ a+ N G. >. N G in kri CC L N R z O a0 N O o00 00 O T fl L R I d Q 4. ccO M z � o N M z O N r SyV] City of Atlantic Beach ' ;.T +- APPLICATION NUMBER Building Department i (To be assigned by the Building Department.) r ` 800 Seminole Road �,� �Qj3 �0 Atlantic Beach, Florida 32233 5445 Phone (904)247-5826 • Fax(904) 247-5845 E-mail: building-dept@coab.us _ — --- Date routed: / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM ) e Property Address: I fI D ent review required Yes No ui Applicant: ?Erra—nning &Zonin '1�y Treeator Project: 1/Qr 1 Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: }�gApproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: get _ Date: <�_ ' �j TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. [—]Denied. Comments: Reviewed by: Date.- Revised ate:Revised 05/14/09 4 uj FP2 M . D N dN v U Z d O_ L 3 M o 3 p p z J a z O z O 0 Q �T) Q L) i 0 m U C� H wQ Q Z CEJ L =L) z C O O E C o G F— U v 0 w Z a3i V z Ow a) 0 C5 W w � CL a W c0 0 U F— LL 7 _ > --' a) C �j C C -0 o Z > 3 mCO .� p O C c o J O 'd W cY E mom- t6E - Ui0-C O � U •O O C O M W p a) .. O a) C i c fd M (n N S a) 0 . _ ( O > C a- -0 C c W d p a) N ` a) d (a O ` tT O cn � > > � _0 cow -6oca � � p3m ' v 7 N 00 J ~ a) c>a 0 p O O Q p 0 p > O ani O i) ` En (n > a) ca O 0 07 U N a) (a V Q p b L (n m o > 0) > N 0- - a> n 0 > `O •� O Qp � L O 7 C L C C Q c M -- to z c>, m0 "- o E c`� � � � u' 3 E u' a � � Q u > O ^ O W p Q� M O U O p .� 0 Q) 0 0 `a U 3YE E N OII QLo UU) -0n - ai - a� c °� °� cl c c m � M � ami o > 0 0 � �_ c E 3 = Q oo O ,5O 0 - " � �' o 0 c � o � 3 a0 0 aci o C: -0 > ai rn - U) o U U N c p N C — p .— U O U N a) to O U a C y d ca (a a) En U> L N C U C = M ca o C) 0 Q > accn0En cQoa) > '- w W w a) Q) M E O -0 N 0 w ca U 0)— -a O CO cC m � 08 ` .L t � - 0ca � Qc � � C } a- - acUE f o a O O O c O p (a ca > �C N CZ O Q C O C a C = to (Ca L O N 0 N Q O UO O a) « o Z O oc ia � cn o � o — cn � p m _0(Dcn ; LL N aco E _mN c 0 o c 6> cn a� a> > c U, o O �, a) a� o E E a� co Q ca ,� U N p E U (n .. 6 J C a � aE ' d Q o � _ >' ` o i3d L Q H Z a=i ai >, E a) Q c t9 �" w N Cl) s M LL co O d t L f- m V fn d d +�Q U a) W :�+ O aNi ayi y O UDQ aoo � z M ,I=)F>T2 F- D L-/ w % m B ( � § = f § « 0 2 2 •> k3J z a E z 0 0 § < cu \ / � m / / k Z � \ 9 W § = 2 0z \ E oq Q & z ) U \ % ƒ � b � W / / W m \ (n \ z _ C/) \ � W d\ p § R / u z v o F- 0 0 z k § 0 ® E � Moh U 0 —E R 04 ■ W U r_ LU / m9w 2 � ■ m = 0 ED@ « � 3 0. , M o Z LL Q O 2 � k / ZQ k o ° 0 � E _ LLLLI \ 2 �M- $ CU o = .. a auj \ / od U O k X 3 0 / d ■ � . : a. .�e.w . . . . � � :. � . .. . . . ��. .,�., � . W z M a O o � N L 01 J O N ~ W Z m j O c � � ` U N ��+ N y Q W o 3 :3 :3 p a z Q J a z O z O o t= � U Q c� U NI O m U (n H H U F- w Q m Z 2 <' ui ° zU E O O �o O wZ 3 U 0 � aw W w d a W a N m 0 Z IE o O (n CW W c Q No O N O t LL C U 0 E 2) N z > O W `m U � � R Y �~ O U O 7 o Q V o V N' r- o W V o 0 m m m o Li U5 'C v °3 � io - d. L-Z LL c a _O R o U- Q Q atS o 1- ZV - O r� cv aW 4)Ev, �a LL m � as p 2 cn a >- a d ,� U Q a` 00 nz ujZ M a O 0 L F- O C. 0 O N � �- N F— r ciL) U � U Y Z d cd 0 ` C F- N N U � O y ppd' Z Q J CL z O z O o F- Q a Co C) 0 co U F- W Q ao w F- �I o UZ E 00 F- U O WZ U zO oU UJ CL p W wLL- r W �' N R o Z O 0 t n is V J � 0 Cf) c W W p No C N N O M m U a F- � N Z `. OW c a L) Q Y Z ' o " --cn U _ o � r � o U � oNE Q z d � W U 3 0 m J d '1 W o m cv CO 'a otf U E) -0 V aC+ y a Z LL :° Q0L ar � �a otS o I— .� I— Z v = c a� Q W aci E mLL ca ca QLB v> a L �' a~ = � W _O N N CL) 0 im+ Adm •� z U Q app BUILDING PERMIT APPLICATION �a C iJ � r' CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 DEC 17 2013 = Office (904) 247-5826 Fax (904) 247-5845 Job Address: �2/�; � ,�{w»,*�,:� %,���,t �°; � Permit Number: _..._._..._.�� Legal Description Parcel# oorArea of hFt. Sq.rt Valuation of Work$ 51-732j 91�.00 Proposed Work heated/cooled jtV,G(1Z non-heated/cooled_ Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed•structure(s)(circle one):• mPirtle Residential If an existing structure,is a fire sprinkler system installed. one): Yes No N /A Florida Product Approval # For multiple products use pro uct approval Form Describe in detail the type of work to be performed: Property Owner Information: Name: lyca ftlw W10. COwt�t�-1 Guy?. \vim• Address: 1\900 SG)tet' — 'nC�CA-r1Y1c� r• City �•1;^- *-;� 3er�.r.,._ State1 Zip_32213 Phone clo4- A77 - ZZZ'7 E-Mail or Fax#(Optional) Contractor Information: Company Name: o or t C'c�+ � ..ray k—<— Qualifying Agent: Be-r� J Qc d�C,iy�S City + �r Address: 2A`k L ZG� A eJ s�^+i J P��' State F L_ Zip 322 3 Office Phone qn>a- 781- Li41 w Job Site/Contact Number aDN- 545-5Fi i Fax# fwxa— 28t-4421 State Certification/Registration# Architect Name& Phone# C%i kF Dy�.0 VN (9DLi1 i3D-2�- Ove4 g O -52CIO Engineer's Name& Phone# { Fee Simple Title Holder Name and Add ess Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance oj'a permit and that all work will be performed to meet the standards of all laws regulating construction in thisjurisdiction. This permit becomes null or and work er void(f o commenced commenced within six 1 understand that separate permits muor st be secured for Electricconstruction or work is ualpWorkior Plumb ng,Signs,aWells, Poperiod ols, Ar aces, Boiler6)months at s,Heaters, Hea[rs, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. max„ 1 here b certify that 1 have read and examined this plication and know the same to be true and correct. All provuioYis9f s d ordina s verning this type of work will be complied with whether specified herein or not. The granting of a permit does not presume't ry a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Contractor Signature of Owner g PrintName ( / ..........Vv.O .................................................... PrintName �._t.0 .................................................... Swo to and subscribed before me Sworn to and subscribed before me this&L Day of �6('eA 4.), -,-. .2 this �Day of l �,-.`3�t 20 l S _.�. N Public ' Notary Public Revised 01.26.10 CATHERINE LEWIN Notary Public-State of Florida My Comm.Expires Apr 23.2017 $ �E � �� �� Commission#FF 011275 ='• •'F MY COMMISSION it EE045088 EXPIRES November 28,2014 (407)396.0153 FbAda Aom tr vy;y City of Atlantic Beach R (F 1A7F__U APPLICATION NUMBER Building Department /To be assigned by the Building Department.) `v 800 Seminole Road DEC 18 11113 3 300 Atlantic Beach,Florida 32233-5445 Phone(904)247-5826 • Fax(904)24.7-_5845 7 '! r de t coab.us -- `---- Date routed: E-mail: buildin @ Z ;tl>' g P Cityweb-site: http://www,coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �{/ Dent review required Yes No m _ teeAd Applicant: ��Q/�I anning&Zonin CC ator Project: L V Review fee$ _Dept Signature ( ✓ Other Agency Review or Permit Required Rvvivw w, steceipt Date of Permit Verified B Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING 2 PLANNING&ZONING Reviewed bY: '' Date: �✓ ��, TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BUILDING PERMIT APPLICATION F2013 CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 - ----_ Permit Number: Job Address: Parcel# Legal Description Floor Ar o q. t. —Sq.Ft Valuation of Work$ 5,_737—j'10-00 Proposed Work heated/cooled )jPt&&7_ _ non-heated/cooled__ Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) circle one):imPRE Residential If an existing structure,is a fire sprinkler system nstalled. one): Yes No N /A Florida Product Approval # For multiple products use product approval orm t, Describe in detail the type of work to be performed:—NEI .- I L-1=11 t L, Property Owner Information: Name: Alva YYIQJ1Y1t7. Address: t�ovV Sat.f� rC�►-��nc�•. fir. City +1 -r;c_ �Statel-L.Zip 32233 Phone �to�-t- S77_ Z7-2-2 - E-Mail or Fax#(Optional) Contractor Information: Company Name: Re Ci cy-r- -OL, k Qualifying Agent: Pette J Q Address: ZN'�- l_�.l e-cl City ±6tOLV)hc, 2C,2r State T->— Zip 32zz3 Office Phone QoN-2y1-.AyI k9 ---Job Site/Contact Number qot i- Sys-semi t i Fax# q c)L1— 2Ai-•44 2-1 State Certification/Registration# O Architect Name& Phone# ��- qty 8 Engineer's Name& Phone# Fee Simple Title Holder Name and Add ess Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is sus ended or abandoned for aperiod of six(6)months at any time after work is commenced. 1 understand that separate permits must be secured for Electrical-Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,eta WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING9 CONSULT AN ATTORNEY BEFORE RECORDING YOUR NOTICE F H YOUR LENDER OR COMMENCEMENT. /hereb certify that 1 have read and examined this a plication and know the same to be true and correct. All provtsidhs 9f s d ordina s erning this type of work will be complied with whether speci ted herein or not. The granting of a permit does not presume t iv a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owner Signature of Contractor �. vv . Print Name ''' '?...... F�. �aS................................................... PrintName ..... ......................................................... ................................ .... Sworn to and subscribed before me Sworn to and subscribed before me ,20(3 this Day of ,)_," !�f�l l�t/� 201 this Day of t�c�� `ma c Public Notary Public NO�� Revised 01.26.10 •1 �'o,, CATHERINE LEYVIN „ = Notary Public-State of Florida � " $ M 1t My Comm.Expires Apr 23,201T ;;y ' 4•% Commission#FF 011275 MY COMMISSION#EE045088 4WXW EXPIRES November 28,2014 (407)396-0193 FiG"ft MOM CITY OF ATLANTIC BEACH Building Department 800 Seminole Road Atlantic Beach,Florida 32233 r t cJFil,�. (904)247-5800 PLAN REVIEW COMMENTS Permit Application # / 3- 3 8'`/ Property Address: A00 Applicant: R P G Project: /"1/(��,. f�, / �P 1y A G• C. This permit application has been: Approved 0 Reviewed and the following items need attention: A r Z✓dlt k s r�40i .� �4/��0'PG/ ''s o 1'1:r4P. S v O Irk t S`� 42 Please re-submit your application when these items have been completed. Reviewed By: . /7-) R Date: k-1 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 0 800 Seminole Road �J Q j r Atlantic Beach, Florida 32233-5445 d (L Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: Z 7113 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: A Department review required Yes No Building Applicant: Planning &Zoning Tree Administrator Project: (,� Public Works _AiPublic Utilities C/ Pu Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as r vised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 J U _ J Y �) J January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road Atlantic Beach, FL 32233 RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1:30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/1/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniak(a-)coab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 s) J January 30, 2014 Mr. Pete Rodrigues RPC General Contractors, Inc. 248 Levy Road Atlantic Beach, FL 32233 RE: Hydrant Flow Testing Dear Mr. Rodrigues: The City of Atlantic Beach flow-tested hydrants at the locations below. The results were as follows: Date of Flow Test: 7/30/2013 - 1:30 p.m. Location: Near 1600 Selva Marina Dr. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE - 36 PSI GPM -1000 Date of Flow Test: 8/1/2013 - 9:45 a.m. Location: Intersection of Francis Ave. and Dutton Island Rd. STATIC PRESSURE — 48 PSI RESIDUAL PRESSURE — 40 PSI GPM — 1090 Please let me know if you need additional information by calling (904) 270-2535 or email me at dkaluzniak(a-coab.us. Sincerely, Donna Kaluzniak, CEP Utility Director cc: Chris Walker, Division Director Public Utilities Department 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 Zi 06ald es� , 6- Sh � �T- BflcK 7 o mC Graham, Shirley From: Ratliff, Bob . ,Ratliff@coj.net] Sent: Friday, Ja Iry 31, 2014 2:58 PM To: Graham, ley Cc: Griffin, Mi, . . al; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: RE: plan re, ,ew for ABCC Shirley,Jennifer, Mike and All! I have received and reviewed the thirc e;bmittal information for the Atlantic Beach Country Club.The plans will be approved with this additional informal� n and I hope to have the documentation returned to your office by close of business Monday. If I need to sign the permit application I can do that when the plans are delivered to your office or if you need it before then, please send a scanned copy and I will sign and return. Thank you, &ptctitL Bdh 9?atV, UPS Jacksonville Fire& Rescue Departmer Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public i rds law,e-mail communications to and from city officials are subject to public disclosure. From: Ratliff, Bob Sent: Wednesday, January 29, 2014 3:27 PM To: 'Graham, Shirley' Cc: 'Griffin, Michael'; 'Walker, Jennifer'; 'Jones, Mike'; 'Hubsch, Jeremy' Subject: RE: plan review for ABCC The second submittal for Atlantic Bea.. i : :)untry Club has been reviewed and the comments are attached. I will try to get the plans returned before close o` , 3iness today. Thanks, &pta& q0g gZact.W,C F P S Jacksonville Fire& Rescue DepartmeW Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax 1 CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public records law,e-mail communications to and from city officials are subject to public disclosure. From: Ratliff, Bob Sent: Monday, January 27, 2014 1:49 PM To: 'Graham, Shirley'; Groff, James Cc: Griffin, Michael; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: RE: plan review for ABCC I will try to get by tomorrow morning to pick the plans up. Thank you, ep pterin q04 gZatW, UPS Jacksonville Fire & Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public rekords law,e-mail communications to and from city officials are subject to public disclosure. From: Graham, Shirley [mailto:sgraham@coab.us] Sent: Monday, January 27, 2014 9:43 AM To: Ratliff, Bob; Groff, James Cc: Griffin, Michael; Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: plan review for ABCC Bob,We have revisions for you to look at for the Atlantic Beach Country Club. sKrl.eu Graham Building Department 800 Seminole Rd Atlantic Beach, F132233 904 247 5800 sgraham@coab.us 2 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road 2 f� Atlantic Beach, Florida 32233-5445 Jo Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us L Date routed: / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: D ent review required Yes o ui Applicant: anning &Zonin lee Ad istrator Project: L 1/GL U 11cc Utilitie u Safety ire Service Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Ppproved. []Denied. (Circle one.) Comments: BUILDIN� PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 ILDING PERMIT APPLICATION ryDEC �_ CITY OF ATLANTIC BEACH FILEV0 1 17 2013 8 Seminole Road, Atlantic Beach, FL 32233 M fice (904) 247-5826 Fax (904) 247-5845 1-Y I - Job Address: I b dy ��V-A 144P PIA Permit Number: Legal Description A?'l4fiN a Parcel# Floor rea of q. t Valuation of Work$ 5t_732,9l1y0 Proposed Work heated/cooled & && non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): mercl Residential If an existing structure,is a fire sprinkler system installed. l.rcle one): Yes No N/A Florida Product Approval # For multiple products use product approva orm A Describe in detail the type of work to be performed: t%y1 /4'lt As-I Trl� t;►��ou T �''{ Property Owner Information: Name:Selma Address: I1,000 Salsa- rC�a-.%��nc�. fir• City a}lanAi, 3ecxc n StatelZip 32,233 Phone Ro�-t— E-Mail or Fax# (Optional) Contractor Information: Company Name: RPL. Gevti,-c%A C'car\Ty;Ar_#_,V S, t`Y- Qualifying Agent: 76eta:�r 3 . Qc�v��>P S Address: ZN Sr LZ City A-cuv ic, Bear An _State F L_ Zip 3zzz_9 Office Phone g0LI- 2. )z Li4l Lo Job Site/Contact Number qOW SWS-6,:�►1 i Fax# 1:1 01A- 2Ak-LILA -7 State Certification/Registration# O 14DLo k9 Architect Name& Phone# C\S-9-1= Du.c�n L` 0Li) i3OZ- q�`'1 g O -5 2o0 Engineer's Name& Phone# { Fee Simple Title Holder Name and Add ess Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby er made to is s obtain a permit to do the work and installations1,,,,ndcas ited. !certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards !lawsrpegulade ting construction in this jurisdiction(. This permit becomes null wnd ork ls�mmenced.ot/understand that separat permits must be secured for Electrical Workl Plumbing, Sigor ns,or aWells�PoolsxFurnaces, Boilers,months at time Hea[etrs, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ii°. - !here certify that!have read and examined this application and know the same to be true and correct. Allpro 9f s d ordina s verning this type owork will be complied with whether specified herein or not. The granting of a permit does not presurde't tv a ori to or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. t Signature of Owner J'41J� Signature of Contractor Print Name . ....... G� 1./ ...D..Oc .................................................... Print Name ...... . . . ........................................ ... .................. /.............. .... Sworn to and subscribed before me Sworn to and subscribed before me this Day ofC'GYVI �l this Day of VbF: -.`� 20 t3 N Public Notary Public Revised 01.26.10 .•`,'����"�e�^, CATHERINE LEWIN = Notary Public-State of Florida ;�r,: '�" o; My Comm.Expires Apr 23,2017 ;jp'��°l4; %.",;F�F,�cF• Commission#FF 011275 MY COMMISSION#EED45088 WNW EXPIRES November 28,2014 (407)398-0153 FWW8 *0M Sy11Jj� City of Atlantic Beach APPLICATION NUMBER �S r Building Department (To be assigned by the Building Department.) 800 Seminole Road 13 __3� Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904)247-5845 'moi JR�9' E-mail: building-dept@coab.us L Date routed: / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �j/ QapartLnent review required Yes No ui Applicant: 7 — anning &Zonin Aa ree Ad istrator Project: U lic Utilitie ublic Safety ire Service Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: QA pFKed. ❑Denied. (Circle one.) Comments: BUILDING ING &ZONIN Reviewed by (�� Date: TREE ADMIN. Second Review: [—]Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 Florida Energy Efficiency Code For Building Construction EnergyGauge Summit® Fla/Com-2010, Effective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desr 13093 Description: Atlantic Beach Country Club Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Exercise Center Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(26 1000) Conditioned Area: 3959 SF Conditioned&UnConditioned Area: 3959 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 9.2 If different,write in: ,•�°5N�0 YAR1 es 87 • .402 - • ATE OF 44 EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 1 of 8 Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 2,064.0 2,465.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 8 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Michael a� Building Official: Date: 12-.,"Z.3 /ZO/ 3 Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify(*)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 129.30 193.70 $2,064 $3,081 ELECTRICITY(MBtulkWh/$) 129.30 193.70 37877 56742 $2,064 $3,081 AREA LIGHTS 21.30 44.50 6229 13038 $339 $708 MISC EQUIPMT 19.30 19.30 5645 5645 $308 $307 PUMPS & MISC 0.30 0.30 73 75 $4 $4 SPACE COOL 53.80 53.50 15775 15672 $860 $851 SPACE HEAT 7.00 17.80 2060 5222 $112 $284 VENT FANS 27.60 58.30 8095 17090 $441 $928 Credits Applied: None PASSES Passing Criteria=2465 Design (including any credits)=2064 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 67% EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File:FL JACKSONVILLE INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light 1 Main entries Yes 30.00 30.0 900 600 Ext Light 2 Other(doors)than main entries Yes 20.00 12.0 240 120 Ext Light 4 Walk way less than 10 feet wide Yes 1.00 83.0 83 240 Ext Light 5 Canopies(freestanding,attached Yes 1.25 800.0 1,000 135 and Overhangs) Tradable Surfaces: 1095 (W)Allowance for Tradable: 1978.1 (W) PASSES All External Lighting: 1095 (W) Complicance check includes a excess/Base allowance of 600.00(W) Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL JACKSONVILLE_INTL_ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq-ft) CP CP ance 141 5 Corridor 54 1 1 PASSES 142 6 Toilet and Washroom 271 2 1 PASSES 143 10,012 Laundry-Washing 150 1 1 PASSES 144 5 Corridor 54 1 1 PASSES 145 6 Toilet and Washroom 271 2 1 PASSES 009 3 Storage&Warehouse-Bulky 58 1 1 PASSES Active Storage 011A 1 Electrical Mechanical Equipment 50 1 1 PASSES Room-General 150 12 Lobby(General)-Reception and 166 1 1 PASSES Waiting 151 8,001 Exercise Area(Exercise Center) 755 1 1 PASSES 152 6 Toilet and Washroom 261 2 1 PASSES 153 6 Toilet and Washroom 261 2 1 PASSES 154 8,001 Exercise Area(Exercise Center) 1,185 1 1 PASSES 160 25,001 Sales Area 385 1 1 PASSES 161 3 Storage&Warehouse-Bulky 38 1 1 PASSES Active Storage PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 5 of 8 Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type:Exercise Center (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) System Report Compliance OAU-1 Dedicated Outside Air Unit System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 14.40 12.23 14.40 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 0.57 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-8 Heat Pump Split System Constant Volume Packaged No.of Units System I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.00 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.30 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.63 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 6 of 8 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File: FL_JACKSONVILLE_INTL ARPT.tm3) Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked Project: 13093 Title: Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance ]inches] Runout? Temp [Btu-in/hr Thick lin] Thick lin] 1F] SF.F] Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 7 of 8 Project: 13093 Title: Atlantic Beach Country Club,Fitness Center Type: Exercise Center (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ftz;all other products:0.3 cfm/ft2 Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed Dropped Ceiling 502.3 Vented: seal&insulated ceiling.Unvented seal&insulate roof& Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat trap required. ❑ Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met u Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings >5,000 s.£;Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 8 of 8 El i � O CL Q C 4n O C4 M CC LZ L=+ O •� v, r U s i v � M U. 4. W Q � c L 0 0 o Q U rA m Q Q Y M u V M C U C Uad C/) O it O M a u N N o Q M O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El N L N N 7 O1 O1O Q1 O\ p CL G 00 O 00 W) 00 00 M ^ N ^ N kl 00 000 N N M Z U CC `. cc F L O ^ O O O O N O O Q\ ¢ A O� � OV) In W, O � vii 00 F^ O O Q. L 4, 41 O1 O, ON O\ O, L d M N M O 3 ; CN 00 v� W M N M C d O cc � SCC ^J v c s ra Im z °moo o x oo x a W cqs a a cl r a C7 .Y ¢ cs -a ¢ CZE cc d F� Op cOC 4 Op N9 O 9 O W X ftS 'O (7) U CQ W W .7 c� W U o a, °o2 0 ° E o . 0 c o cz ° C poC o ci Ea A ,., N E N N ¢ ^ N M N M kn o 0 0 N Z N N M kn N ^ N M 7 kn 00 O N N C C • O 0 0 O O 0 0 O O O O 0 0 0 0 O O O O 0 0 O O 0 0 O O O O 0 0 0 0 O O O CC cC c� iC iC cC <3 cC aS cC cC iC —0i0 RS cC cC C 3 7 7 7 O C 7 O 7 C 7 7 7 C 7 O C C C C C C C C C C O O C C C Cd C ❑ C C kr) p M 'V W) O 00 00 O O l� V) .r-� O 00 M N N M M V' N kr) V1 00 00 v) vl 00 00 00 v1 O to 00 Vl 00 kf) vl 00 O N .T V1 M b� 7 R b�D L b4 b0 by bA b41 bA bA bq b4 b0 bA bq bq Oq bq b4 bA bq d bA bq by bA bA bA bq bA W bq bA bq by Op b1J bq bq bq iC c� iC iC iC cC cC cC iC c� ca id cC ic! i� cC cC iC L L L L L L L L L L L L L L L L L L N N N N N N N N N N N N N N N N N N C C C C ❑ C C C C C C C C C G C C C N N N N N N U U U N N U U N N N N N C C C C C C U U U U UU ULn U ti N kn Lei Lam. 3�i L L °- Q N N kA N kn C d 6� d 6J d cd N 6� d d d GJ CJ 67 ci u u u u u u u u u u u u u u cC cC cC cC cC cC cc cc R. cC cC RS cC cC M A V1 VJ V] V] Vl VJ V1 V] U] CA N C .Cr .C. C � � C � r0. ►_. � � \ O � N e ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 7 m N N N N N N N N N N N Gz. N N N N N N N N N N N N N N N N N N N N N N L N N N N N N N N Q �z L+ i <<1 N1 fel M M M M M Cl? M M ,uj F" u 0 0 0 0 .r kn V) �n vi �n v� wn vi vi vi W) o o O o 0 0 0 0 0 0 o x a o 0 0 0 0 0 0 0 0 0 0 0 o 3 w, o u o o u y LLn z z° w CA 3 0 A � i F" cc O M O M kn to O O O C Q N M Nm 00 r- 00 � u O O O O O O M Cl) Cl) M41 3 p cC O O O O O O M M M M M = a c m cc in n CN 00 O 00 O O 3 N M N M n at cC m at cC cC M 0 c0 cz cd M M M M M M GM E M E M E M E ME O u °1 u 0 u O u O*l u 0 u Q\ u 0 u O� u o" u ON u O O N O N O O O O N O N O O N M M N M M v' M M M M Q r. Q Q ^ Q •--• Q ^ Q Q Q �--� Q •-- Q ^ Q G O i.+ a L T T u E 'un vui � � � Cd ti y e N ani ani Q Q u ° 03 � 3 3 3 3 3 3 d3 3 3 3 3 en ^ o Nz w 3 z Nz w z 3 E N M kn 1D q ^ N M kn eq z ~ ❑ ❑ ❑ ❑❑ ❑❑ ❑❑❑❑ ❑ ❑❑❑ ❑ W N 0 0 o v o : O M "D O M M O DO � � M M M \O N M M � •cY GGT rte, `v, O d Z � C � 0 u � W O O IO O O -O I'D N N N �.G N 1.0 N N �O \O �T IC lC �.o = L. O cc O V a O O O O O O O O O O O O O O O O O O W) O Wn O O �n W, Wn Wn Wl Wn N N N N N N N N N N N N N N N O aQ Q O O O O O O O O O O O O O O O : n I: v1 vl 7 vl v1 vl + L O O O O O O O O O O O O O O O rte, G p u �f O O O O O O O 0 0 0 0 O O O O O O O O O O O 0 0 0 0 O O O 0 Cl o O O o 0 0 0 0 0 0 0 0 0 O o 0 0 0 0 o O O O O o 0 0 0 0 0 0 0 o Cl o 0 0 0 0 0 0 0 0 0 0 oo v n 'T "I' 'T W, W, I:r W� v, n v o O o 0 Cl 0 0 0 0 0 0 0 0 0 C) 3 y y y O O O O O O O O O O O O y >- > zz zz z z z z z z z z o = � � w O 'O 'C 'O 'U 'O 'O 'a "O 'O 'O '6 •C a� r. a� a. a_ c a- = = = = a) c ai c 0 o wt47. � 4. z. wL 4, . a=. � w a� a, a, a, Q vod L a) N N a) a) Q) Q) N N a) Q) a) a) a) u N C VI V] N !n Vi Vf V1 Vi N y y V1 V1 N V1 G q kn C ❑ C OC C C C O O C O O O C Ca 3 O •^ O O •^ O O O r 3 3 Q 3 3 3 3 Q Q 3 Q Q Q 3 = 3 N v T IT o It OqlT T 0 0 0 O O o o c X (V N 00 N 00 N N00 00 v1 00 00 00 Wn X X X X X X X X X X X X X X G •cY 't O It O X 0 0 0 ,. O O Cl O •y O CC N N N ^ M N M N — N M M M M M M M d 3 0 3 CW z � � = W N Z •-- N � N M � v'� � -- � r-. M �t ^ O O — N _ � c 3 N N c C V') k Q kn 'r, G= N N C 1 w Q�. E47 F" V'1 V'1 kn C L ' U oN oN M f7 M M cc w W Z �. U 7 O O O O O C O O C f cc C L C Q r^ F" 00 00 oC GC tr •� ) U C C s z £ O y N �O O O O C kr) , W N In Gz q M M cam, r•, `� � w CC L � � L C oo �0 79 c r., g 8 S E _ _ _ E N O N O N O N O u Q Q Q - L1 Q �- f1 Q ^ LL Q •-- Ll i, O O C. M M M f7 3 N 3 3 3C.0 d o o CC o o cc a via za via, z `" G vOi N C ai N d .. y _ •• — D cN Q aN Q 0 c c o N o c c c ❑ ❑ 00000 0000 ❑ r u ti c7 cam, � Q 0 C _ _ A � 6J _ y vri o o d o � 0 0 M o �o "o 0 is 00 E O w 8 w d p O p ii�MM i-. +�+ U O v' U O O O w N C 7a a cN W) O� G G O ClrA E O 00 �O U R O O kn R 7 CC O x b�0 CA w c 8 v, •a rA ca Q. -- M C6 u G o. C 4) c. o u a p U i o � oE Q- E E F o o ^ L ^ O L E E ri o oa E E v'i o 0 y v °? '- A a > >, •E � x L � �, •5 � � L L � U p ami '- = = U p '- c U ¢ ¢ Q U x N N N M kn 0. 00fn 0. N c c C d ^ _ r. El El ❑❑ ❑ ❑ ❑ ❑ « � \ \ / \ \ ) § § § 2 2 £ £ 7 2 2 Q Q a \ ( ( \ ( u § @ @ @ / / Q \ \ � . \ \ 3 — / k ® k g S % / < od = 4 4 = — cj � 3 ƒ } \ \ caca LU � j cte ". / /Qj k cz as O [ ; 3 = § o k $ z \ \ co c � .§ \ o /\ .. g t — § _ § /a \ / 3 § / ; u \ y � j \ / \ 7 7 ƒ / \ m G ) 7 k u { ( 0 000 S CN o 0 yN N N N ^ N N c7 N y O O O O O O O O O f1� O O O 00 O O O O C O v U00O O O M M A — k o 0 0 0 00 0 0 00 N 0 0 CD p O O O O O O O O O O � U " 0 0 v rq O O 'i r- 0 0 �Vim' N 000 O V 4y. O O O � O �y O O ^ 6 6 O O O O W V O O O O _ _ Cn 'U3 O M O O O cJ 0 O O 'ct ClO O M 00 ++ O O O h' — W) M 0 0 (= tn \�O O N 00 M CT 00 CL N - N O kf) O ^ O 00 CL C� a kn o ^ c i o 6 0 0 ? 0 0 0 0 o N au G� cC U O O yv V c oo d o 0 0 o o o o o o o Z Z W a� c O O Z W O C7 'g W W W N z kf) a� `n WOLI w a H pow C � a Q � xC) -u u u C OQ `- c °' ° � � o � r� � 2 O . .aN UimU C) ¢ ° mars ¢ � a o A 33 r ti vUi ^ N M 'cY t..J r•�- r�- O O O O oro r C 00 .— O O -,T3 O N �--� N 7 V o0 00 N '6 L V CYC fC CYC CYC CYC cC CYC fC CYC CC CC Q• A. L1 Q. M 3 Q 0 O N E Z 00 W) 00 ^ O � O O O O ^ O O O 00 O O O O Z M 211 R N N rF N ^ 0 s s v R V'i CQ M C R R O O O R R O O O tu � N C � p O �•l � 0 0 o F o u W5 u E u L O u i O Uo ° an U o cl a as CL kn 00 N 7.: N L N M U a � O � d y O N M z o z o ^ N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ M M v O U o Ucc ry C L O O O O O O O L O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R M o 0 0 0 0 0 0 0 as rz6 d rz6 c �. c � w o ^a o o U — _ as1" O N h w oo 11w O 00 7 > O O O O Cl O O O a+ CJcj y U F 1 O [- z 5 2 era C W ca C N y ° rs, U (w cd ¢ ZWcq W C c Q W U N Q O ¢ C7 O (� C L� Ct00 cn cdcz a a W � ❑ � •N � � � � � 'v, 4r th L ¢ a x ¢ rx 0 �, ° ~ M O o0 N 6� o O r" O O O Ca Z O O N O R Z O DD N O o0 O E N gu L 3 -• N M V v1 �O [� N M v) [� co N cc E o cc cc O Z cc O N ° ° c M N O .� 7 67 bIl 7 R bill L d C W _M O N M N Florida Energy Efficiency Code For Building Construction EnergyGauge SummitO Fla/Com-2010, Effective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: 13093 Description: Atlantic Beach Country Club Owner: Addressl: Enter Address here City: Atlantic Beach Address2: Enter Address here State: FL Zip: 32233 Type: Dining:Bar Lounge/Leisure Class: New Finished building Jurisdiction: DUVAL COUNTY,DUVAL COUNTY,FL(26 1000) Conditioned Area: 11138 SF Conditioned&UnConditioned Area: 11138 SF No of Stories: 1 Area entered from Plans 12211 SF Permit No: 0 Max Tonnage 14.5 If different,write in: NO �,eD Q- NS %off''. o.40 87 ; •. T SOF Fi9 ` „Y'Hgiie�f• ir- f. o111111l11"41 , EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 1 of 13 Compliance Summary Component Design Criteria Result Gross Energy Cost(in $) 7,668.0 8,029.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 2 of 13 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Michael Kratky Building Official: Date: /.2,//31"zor 3 Date: I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Susan Wood Date: If Required by Florida law, I hereby certify(")that the system design is in compliance with the Florida Energy Efficiency Code Architect: Cliff Duch Reg No: AR 0014227 Electrical Designer: Thomas C.Nielsen Reg No: 53492 Lighting Designer: Thomas C.Nielsen Reg No: 53492 Mechanical Designer: Farshid Yarizadeh Reg No: 40287 Plumbing Designer: Farshid Yarizadeh Reg No: 40287 (") Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 3 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Building End Uses 1) Proposed 2) Baseline Total 481.90 630.80 $7,668 $10,036 ELECTRICITY(MBtu/kWh]$) 481.90 630.80 141216 184831 $7,668 $10,036 AREA LIGHTS 124.70 136.40 36529 39976 $1,984 $2,171 MISC EQUIPMT 83.80 83.80 24564 24564 $1,334 $1,334 PUMPS & MISC 1.00 1.20 304 359 $17 $19 SPACE COOL 179.70 186.30 52664 54576 $2,860 $2,963 SPACE HEAT 23.90 56.00 6993 16408 $380 $891 VENT FANS 68.80 167.10 20162 48948 $1,095 $2,658 Credits Applied: None PASSES Passing Criteria=8029 Design (including any credits)= 7668 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 76.4% EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 4 of 13 Project: 13093 Title: Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File:FL JACKSONVILLE INTL ARPT.tm3) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) Ext Light I Uncovered Parking Areas-- Yes 0.15 75,000.0 11,250 855 Parking lots and Drives Ext Light 3 Walk way less than 10 feet wide Yes 1.00 120.0 120 400 Ext Light 4 Special Feature areas Yes 0.20 21,000.0 4,200 520 Ext Light 5 Main entries Yes 30.00 6.0 180 30 Ext Light 6 Entry Canopies Yes 1.25 432.0 540 600 Ext Light 7 Other(doors)than main entries Yes 20.00 39.0 780 540 Ext Light 8 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 9 Other(doors)than main entries Yes 20.00 12.0 240 30 Ext Light 10 Canopies(freestanding,attached Yes 1.25 705.0 881 105 and Overhangs) Ext Light 11 Walk way less than 10 feet wide Yes 1.00 48.0 48 60 Ext Light 12 Building facades(by linear foot) No 5.00 58.0 290 120 Ext Light 13 Building facades(by linear foot) No 5.00 36.0 180 160 Tradable Surfaces: 3170 (W)Allowance for Tradable: 9994.279 (W) PASSES All External Lighting: 3450 (W) Complicance check includes a excess/Base allowance of 600.00(W) Ext Light 13-- 70W from the excess/Base allowance was applied to this item to comply EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 5 of 13 Project: 13093 Title: Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File:FL JACKSONVILLE INTL ARPT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq-ft) CP CP ance 003 1 Electrical Mechanical Equipment 51 1 1 PASSES Room-General 004 1 Electrical Mechanical Equipment 75 1 1 PASSES Room-General 111 7 Food Service-Kitchen 1,500 1 1 PASSES 111A 6 Toilet and Washroom 46 1 1 PASSES 113 17 Office-Enclosed 104 1 1 PASSES 115 7 Food Service-Kitchen 120 1 1 PASSES 104 5 Corridor 158 1 1 PASSES 109 5 Corridor 57 1 1 PASSES 110 3 Storage&Warehouse-Bulky 77 1 1 PASSES Active Storage 119 8 Food Service-Leisure Dining 1,303 3 1 PASSES 119 8 Food Service-Leisure Dining 559 3 1 PASSES 116 8 Food Service-Leisure Dining 710 1 1 PASSES 105 17 Office-Enclosed 128 1 1 PASSES 106 17 Office-Enclosed 128 1 1 PASSES 107 17 Office-Enclosed 128 1 1 PASSES 100 12 Lobby(General)-Reception and 280 2 1 PASSES Waiting 101 12 Lobby(General)-Reception and 214 1 1 PASSES Waiting 102 17 Office-Enclosed 150 1 1 PASSES 103 12 Lobby(General)-Reception and 151 2 1 PASSES Waiting 117 5 Corridor 62 1 1 PASSES 118 9 Food Service-Bar/Lounge 182 2 1 PASSES 119 9 Food Service-Bar/Lounge 92 1 1 PASSES 120 9 Food Service-Bar/Lounge 659 2 1 PASSES 120A 3 Storage&Warehouse-Bulky 59 1 1 PASSES Active Storage 120B 1 Electrical Mechanical Equipment 74 1 1 PASSES Room-General 121 9 Food Service-Bar/Lounge 782 1 1 PASSES 122 25,001 Sales Area 578 2 1 PASSES 123 17 Office-Enclosed 182 1 1 PASSES 123B 3 Storage&Warehouse-Bulky 40 1 1 PASSES Active Storage 125 5 Corridor 30 1 1 PASSES 126 5 Corridor 48 1 1 PASSES 127 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 128 6 Toilet and Washroom 410 2 1 PASSES 129 5 Corridor 72 1 1 PASSES 129A 1 Electrical Mechanical Equipment 28 1 1 PASSES Room-General EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 6 of 13 130 8,002 Dressing/Locker/Fitting Room 307 1 1 PASSES (General) 131 1 Electrical Mechanical Equipment 25 1 1 PASSES Room-General 132 6 Toilet and Washroom 614 2 1 PASSES 135 5 Corridor 40 1 1 PASSES 136 5 Corridor 125 1 1 PASSES 137 6 Toilet and Washroom 232 2 1 PASSES 138 6 Toilet and Washroom 214 2 1 PASSES 124 1 Electrical Mechanical Equipment 38 1 1 PASSES Room-General PASSES EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 7 of 13 Project: 13093 Title:Atlantic Beach Country Club—Main Building Type:Dining:Bar Lounge/Leisure (WEA File:FL JACKSONVILLE INTL ARPT.tm3) System Report Compliance RTU-1 Packaged Roof Top Heat Pump System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 10.80 10.60 11.80 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.30 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-2A Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-213 Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.90 11.00 12.00 11.20 PASSES 65000 to 135000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 8 of 13 Heating System Heat Pumps Air Cooled 3.81 3.30 PASSES (Heating Mode)65000 to 135000 Btu/h Clg Cap Air Handling Air Handler(Supply)- 0.42 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-3 Heat Pump Split System Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.70 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AH U-4 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software. Effective Date: March 15,2012 12/13/2013 Page 9 of 13 I AHU-5 Heat Pump Split System Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 11.70 10.60 12.00 10.70 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Heat Pumps Air Cooled 3.56 3.20 PASSES (Heating Mode)> 135000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.53 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-6 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 16.00 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 9.00 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) AHU-7 Heat Pump Split System Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 15.50 12.23 16.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 8.50 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 10 of 13 Air Handling Air Handler(Supply)- 0.39 0.82 PASSES System-Supply Constant Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution ADS System(Ret) 6.00 PASSES System(Ret) DSS-1 Ductless Split System Heat Pump Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 17.00 12.23 17.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 10.80 7.70 PASSES (Heating Mode)Split System <65000 Btu/h Cooling Capacity Air Handling Air Handler(Supply)- 0.45 0.82 PASSES System-Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 13093 Title:Atlantic Beach Country Club—Main Building Type: Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 95.00 Not Checked water heater Not Checked EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 11 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining: Bar Lounge/Leisure (WEA File: FL_JACKSONVILLE_INTL_ARPT.tm3) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance linches] Runout? Temp [Btu-in/hr Thick lin] Thick[in] [F] SF.F] Domestic and Service Hot Water 1.50 False 140.00 0.28 1.50 1.00 PASSES Systems Domestic and Service Hot Water 1.50 False 120.00 0.28 1.50 1.00 PASSES Systems PASSES EnergyGauge Summit@ Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 12 of 13 Project: 13093 Title:Atlantic Beach Country Club_Main Building Type: Dining:Bar Lounge/Leisure (WEA File:FL_JACKSONVILLE_INTL_ARPT.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner E 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfm/ftz;all other products:0.3 cfm/ft2 Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed Dropped Ceiling 502.3 Vented: seal&insulated ceiling.Unvented seal&insulate roof& Cavity side walls HVAC Efficiency 503.2.3 Minimum efficiencies:Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions);separate thermostatic nj control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed 1I HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached,sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2,502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010.Section 506.4 Compliant Software.Effective Date:March 15,2012 12/13/2013 Page 13 of 13 C W N O O O O O O C C C 7 C C n CD fD fD (D N CD W W 41W Cd D ! S7 0. 3 z � O p,, S to a• Z CC O d Z d n N W 0 O' CD � '77 W0 CD G D DCD n W N CD cn LI) � � O CD CD zz ° ozz -� CD CA oc n CD -3 CD `3 � o Q.uj ra o 00 � C, a ra L .o 00 cn C, � _ Jr O J C1 N O y CA _ 111:1 IJ El El El W W N •--• p N W N p C1 to A W N — Z N A 'D O O O O W J C\ to C\ O O cn W fa cc cu cu O O O D C O 00 �1 C\ 7 W A N N � a d r b w n" CD Chi ry'1 °O a c = 7� `D ao ao va LnCD `° °o F. o `; o o m m o 3 e o cs 0 a 0 CD Uo w cc CD -e O cC < n n `-° c O o o CDCDCDCD O O O O 'TI d 'TI d 111 CC cn (� �] 'Tl O CD n n n UaCDtro CDoc CD D o o w 9 6' 3 c)' r O O O CD 0 0 0 0 CD CD CD ° °o o s O O O 71 CD c n. C CD ° o � �- o x Z Z r' C n o n r' C17 [17 CD cc cn cu (D co — co CD CD CD o � w C C CD A ON1 W •Orn W1 °O `O O O ?` oWo °° J 00 Cl W 001 O 000 w C� C A O - _ ON1 W O� Oo D1 01 W 'W. C1 bN W O v O O O 00 W 01 A `T N N = NN 10 10 �O 1D 0 10 .:y W W W W to cn W W W O O O O O O o0 W W W W O O W W W Cl O O O O O K O0 O � O 3 0 "t .r O --4 —1 00 O 0uj 0 — a �O �c 10 O C1 N O O O O O O O O O 00 00 n 00 00 N W v 00 oo � to J ttA O O �D 10 1D W D1 N N to 0 O 01 W O to 00 C 0 W W W o0 N 00 0 J O 00 A 0o N --• N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ N —1 ON N CD CD A A p .-+ — — — — — — — — — — r-+ — r — wr N N N N N N N N N N N N N — — '--' O O O O W �p \p 00 J N w w N .. O O O O W v W N O eD CD 0 CD CD CD A�7 O i"1 "�� y CD r UQ CD r CD C O CD CD y N N A V] O O y Gn 0 = C 0 0 CD CL CD O CD 7y C7 to td n 73 ;o n c� tC v� p Ln It tri m w U) It It ~n C) r p °O C " ° ° °O C 0 C n ° °O O O Q- ao - C °- c- c o o�r o Cs Cs Cs a ° VCD 'Cer CD U, tro o C)cLa -e '' SCOCO CD P �. Rc° ~ E• coo . coo CD „00,1 0 0 CD CD to CCD C � N '7d � � G N N CCD � CDD o � CD � CD CD 0 CD CD CD `C b4 CD UQ CD `J CD (D = f= = w W CSD CRL CD CD N M C _ �l tA 00 O J O� N � 1 j � J oo J lNit �o w J w oo w 00�p A J O O° J �o �O °° C A p to Oo G J D\ to aN �,�jtj v 00 v kA . w . N N ? j OAO N W 00 N A O 00 V U W V O O O O O O O O ca O O O O W W W W W W W O Cl O O O O Cl O O �,� O O O O W W W W W W W CN N_ N J ONO N C J OAo O O N J N O0O tJ N N �-' O ? O O O �, O C C O O �p O O O N J tNit ON W N v N — Oo G N N O O Owo t1iO N N �-' O to pN �o C .A pN DA N 07 O1 = U C Oo W N O N w ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ N O O _ O N CD O V1 V1 V1 V] V] V1 V1 � .-• � � 00 J C\ N N 7 7 a N �, W A W 00 Cil 00 CD o C 0 � O O = C O 115 O d O D < N < CD < CCD � � v �� � N � r c CCD � Co N cu CDz3 a co 3 maC. '" CD of 9 C "' CD W CD h7 .iy `� i7 �r1 0- o o C � C ^� C C a C ?7 Ko i y 0 0 0 0 o c c v c c c o 00 00 CD 0 CD CD (D C CD Cil C?7 0- 0� (� p -O i Cil m n N O O O 0 0 coo CCD CD 0 CD CD �' r: �'• ro 0 n � y CD CD CD CD CD CD CD o o TQC= a � �= CD CD 0 0 0 00Q W 000 00A UOQ 00Q 004 O O O C) C) CD CD CD 10 [� N cor. _ = r � z o ,: y ��A�/�• J w v 00 N o'o O ® W( O\ `0 N O 10 00 00 Ch 00 VA VA A• 'I'I' W W O Vl 00 00 00 00 00 00 O CO A O1 00 00 00 — A W O O O O O O O O O O O O O O n z W W N N M W ON �p O A ❑ ❑ ❑ ❑ ❑ ❑ ❑ ND 7 7 '7 A C 7 C A 7 D CCD D 7 7 ►+ 'O '�7 'U �7 'C '� 'C '� 'C3 `C '� 'C 7 D D Z ih r �n W Z 7d Z 7d z 7d (n t" Qn Ln r (n vi w r p (D riy C c 0 CD p N p CD C C c CTf c C c (� n y y0 C� n ti y w fn fn vi < cD d v o < CD < < cD D d v o d v o b d CD w CD CD CD rA CD N CD N CD (D CD CD CD CD CD p„ a, eD-' 0 CD .=+ CD m CL CL CL m CL C1. CD 0 C1 CS. Q. CD CD CD CD CD 0 77 0. 0- ori Irl 'r1 a a Cl. Q. 0. M. ITI ll� c` c Tf 177 hi 171 h7 CD CD N 0 0 CCD CD CCD n 0 0 0 0 0 CD 0 D D CD cD co 0 CD cD C) c) c) c) C) n C) C) C) C) c) c) C) C) n CD CD CD CD 0 CD CD CD CD 0 0 CD 0 0 0CD CD CD CD CD CD0 CD CD CD (v CD CD D D D D D D D D D D D D D D D c -, •, •, •, •, - n 0 CD CD o -s -, ti -, •, -, •, K •, w r r r r r r r r r r r r r r r r m aro oQ UQ UQ+ D+UQ UQ' UQ aQ UQD' D 19' D 19' aQ oQ IQ Ua D' D' ? D+ D 'S D- �' s D+ D- — rD a4 UQ UQ QQ uQ UQ UQ UQ UQ UQ UQ UQ UQ UQ UQ (r TQ n C TQ CD C 10 L1 C A O O VA N O W O W CT O W 00 N O O 00 00 00 O O O O O O Cl 00 '✓� _ _ _ �+ .-� � N W �--+ G1 O O a, CT � C O O O O O Cl00 C c C C C c C C C C c C C C C O 0 0 0 O O O O 0 0 0 0 0 0 O 0 �:4 �:4 ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ N C C N NO 3 COD .7 O .7 'O C=9 O O O O O 7 .7 COD O V1 Vl V] C/] V� V� V] V� V1 V� V1 V1 V] •• a a a a a a a a a a a a a P1 f7 C7 f7 f7 n f7 A P1 C! C) A A CD � C CD A �D CD N CD CD fD fD CD CD A C O � O O 00 — -1 � � a r r Ln r (40 r r r r CA r r r r rri _ D d d CD d O d d CD d d (D CD d Q d a Q.. o o. a. o CD c aCD o. c.n . 0 0 0 0 0 0 CD CD CD (D CD n n CD CD n n n C) C) C) C) G7 G7 C) C) C) C) C) C) C) C) C) C) C) CD CD (D CD CD CD 0 CD CD CD CD CD CD CD (D CD CD CD CD CD CD (D CD CD CD CD CD CD CD CD CD CD CD CD m w oc va «o as cro' aa' va aa' oc va' m m tro oa aa' as va' va as w ao vo vc va m cro oa m oa m as oa oo ac TQ n c _ :t A O W W cn r O W 01 D\ O cn cn 00 cn O O cn vi cn O cn cn O O to O v, (A W W N W W N r N W 00 W cn cn 00 O CN O O O O O sw O C C C C C C G C C C O C C C O O O 0 0 0 O O O 0 0 O 0 0 O 0 0 0 0 O-h 0 0 0 O+, O O 0�--h 0 O 0 0 O 0 O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 00 N N A C'1 A A f7 f1 A A A n A fD C CD A fD A f9 fD �9 A fD fD r A `r N 00 A 00 �z 00 a cnV) o [7 l 7 t 7 lT a a t 7 a trT1 CrrJ m tr17 < CD o d a d O d Ts O o d o d v d O CD w CD CD CD CD CD C '* C9 CD CD n n u CD CL 0 CD CD co CD CD a .n o. a a o. c CD a c c c c c c 0 0 0 0 0 0 C) CD (D CD CD CD CD CD CD w w w n n n n C) 0 C) C) C) C) n n c) C) n c) C) n C) CD CD CD CD CD CD CD CD CD CD 0 CD CD CD CD CD U4 UIQ On Ua Ua Ua Uo UQ Uc Uo w Ua Uo Uo Uo UO IQIQ G1 y C UO l9 C K C A O 00 A A A A A A 00 O Vi O cn Vl A N 00 O V' O O v' O O O O O w p c�A O '?o w w W C C C O C C C C C C C O C O C O O 0 0 0 0 O O 0 0 O O O O 0 0 0 O 0r-}� 0r-h 0 0 O O �0 0 O 0 0+, O O�-F, m ,apD��,j O z tp C/J `z Ln M z •AS �i �i V] LTJ 2 'jam CD CD CD CD CD N y CD y N y N y VJ h N VJ y cc c° w ce N t1� A W N NCD ... C `C YW YWY ,� > w on y WYWul YW �YCD W �YW � W �YWDWYWYW two t`�o c�'o b � 0 � 0 � (V � q � 0 � 0 � 0 � 0 � `,7`4 `Tizi `Tizi `C� i oo 0 00 is x G� o w is w w w w w o O o c ►„ C O W W W W W W W O O O C V 5 r+ �+ UW CT -- N N 00 C� O O AZ Z t.A -1 N J N N CN Z z o m z c 0 c y o 0 c �, 0 � o 0 o O Cl O O O o o O O O O ^^ ? A ? A ? A A A A A A � :� A cn cn v� cn cn to to cn to to to to cn v, O O Co O O O O O Cl O O O O C, !y ; fb A owlJl l/1 111 l/1 kA Vl U VI Vl VI VI VI U LA y AK A. t: W W W W W W W W W y N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N p x � � ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ w o ►-� � o o cn w NN t! N pZ CD N N CD CD C Y C C— _ a U- CD CD W Cr C W O O O A A AaN 00 00 O 0 Cl 0 A O A Z C � o 0 0 0 0 o y w � w > w y w w y W � W > W D W o o Cl o V, Cl ow o w o o CD CD CD \,p CD �O CD 1,0 CD �p CD �C CD \,p CD ',p E w E w �j w w w w w w w C C C C C C cr 0 CD -, CD CDCD-_ " " vCD -- — — — -- C7 C7 C7 Cl C7 0 f CD CD CD CD CD Q o 0 0 =1 CD a. c. a. n. c. C7, W `D u N CT _. J N � O � o Cs7 O O O O O O Q. O O O O O O O to W tN O O AD O O O O O O C O O O O O O O OCD O O O O O O 0 0 0 0 0 o C7 C� o\ ww w o A A A A A Z O O O O O O CU O C to cn t.n O O O O O O O O O O O O O O O O O O A N A N cn v, vi cs �n to cn cn v, Cs ON O O O O O O O O O O O �] A —1 O J O C7 �• C tA to cs N A A M to to cn cn �n to to cn v, VD W W t>> W W t-j W tJJ N W A W PNS • N N N N N N N N N A J O A O CCD AD N N N N N N N N N N N N N N N IJ N N �❑ 0 1:10 ❑ 0 0 0 0 0 0 0 0 y -- � W N �- �.' --� t! � N -- � W N � N � t � -- �' '—' t! A W N •-' C A -- [.,) —• �! N O C 0 0 0 O CO1 O G CN C'� O CN 0 ONO ONO D1 C O O A O ff" G O O X X X X X X p_ Oo G 00 C1 00 Oo C1 C1 G 00 C\ C\ 01 Vi CA 00 00 C\ N to 00 00 p 0 p 0 0 0 O CN C1 p 0 C� CN C� Cl O Cl p O 0 A O p 0 0 o CL CL CL CL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C C C C C C C C C C C C C C C C C C C C V] N N VI VI VJ V] V1 V1 w V1 N V1 V) VJ V) (/I m Vl CD CD CD CD CD CD CD CD CD CD 0 CD CD CD CD CD CD CD CD 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CD CD CD CD fD (D CD CD (D CD (D (D CD CD (D CD CD CD CD CD :h 'moi .i �'�2 `."i .*i � :.'h � :.'�'i ':.'h :_'h '.7i C 0 Ci CD N CD C C; CD 0 CD Q CD Q CD C 7 Ci C C C C CD (D CD CD (D CD (D CD CD CD (D CD CD CD CD CD CD CD Q. Q. Q Q. A0 0 0 ID N N Cl Z 0 0 0 0 0 0 O 0 0 iv O 0 0 0 O O O 0 Cl 0 0 O O O 0 0 0 O 0 0 C to to ? A A ? A ? A ? A ? A A to ? A to O 0 0 0 O O O O O O O O O O 0 0 0 O O O O O O Cl O O O O O O O O O O O O O O O O (n O C O O O O O O O O O O O O O O O O O O C '* O O O O O O O O O O O O O O O O O O O O A A A A A A A A A A to A A A cA A O O O O Cl O O Cl O Cl O O O O Cl O O O O O A O O O O O O O O O O O O O O O O O O O O O to v, A A A A A A A A A A A A to A A A in A O O O O O O O O O O O O O O O O O O O Cl N N N N N A N N A A N N N N N N N N N ll� ul to to to Q\ Vi .-+ C\ C1 VA W W W to to C Vl t/i to O O Cl O O J O J J J O W W W O O O O O O a1 C, cA C1 PN to cA a1 N cn cn A A D1 C\ c.A N A 57, C\ to 01 C� O C D1 a\ J J O J J O O J O O O J J J J O O J J J W W N C1 01 W 00 W �O �C J W N N O Cl A A in J J A 00 00 A A J A cA O DD❑ ❑ DO DD 00 0 0 0 000 0 00 o N N W O O O O y p y y y = y • N C N CD CD > CD CD Z' Y R: o a C y OD O C 'O (71 CN C oXo w 01 v, N 0 O O p 0 O O O A 0 0 0 0 0 C C CD CD (A C) Vl to h Vf (A CD O fJ .�.( .�.( �"{ .may .�.t ^�'t .�+ CD CD CD CD CD CD CD Ih CD CD CD CD CD CD CD O C O O O C C rD '' K a o o o rn o 0 Q9 v y = C O O O O Cl O O C v O O Cl O O O O O O v .•-� O O O O O O O n O O O O O O O o 00 ? 3 Vc 1.0 O O N O O O O O O O C. •� O O N N N N N N N cn cn to cn O O C c�i� 0. W C to cn 01 N to A N O O O O �'y � O � :n •� w -- W N A A AD C y d � ^ 001 001 0 y .T' O to 00 O A O w w � w � � C C O N N O O O O O O O w o o N N N N N N NN a N ° a N o a N o a N o a N o a N o a N orD o o o o o o o CD O O ,� O O O �� O 0 O W vD O Cy tD y (D CDN CD (D CD CD (D N CD (D fD f1 00 J C1 El V, � ? s w N �. tv O O O O O O O O O A M A 'C O 0 0 0 0 0 0 0 Or N o CD El 9 o CD CD CD CD CD CD CD CD o C1 W �O 00 W OO �O W � C c� Z � � � � oNo w oNo [/] A CD - O O N 41 G c w uj00 00 00 v, w o — m 7Z 0 0 0 0 0 0 0 o o 0 0 0 0 0 0 0 y,1 0 0 o c o 0 0 Z �*. � � � w CD .,, v, n u, kA DD o � 0 0 0 0 0 0 0 w ON C V W W W <D _ y N 0 0 0 0 0 0 ❑ o CD o CD Y o CD o CD o m o vD o o m (7 = Oo = J Ln = :" =3 t1i �' =3 = N O CD CD Co CD CD CD CD 0 CD CD CD CD CC CD fD > p y 00 E cn � A W E " O' DN vc ua 0 0 0 0 0 0 0 0 va sz a., `-i O O `-ID O O `-sD O O 0 O O CcD O O `-1D O O `cDD O O rD O p a w = v m = v m = v w = Ts w = a w - o w = o w hb m n a� n w n m 0 m C)i err a. CSD cL CSD N 0. O.. CD Q. N d N G. CD CD CD CD CD CD CCD CD N CD b C Cr1 A N A N w w Oo W 00 to �O n y UQ Tn Q V1 f9 O O N A O C'D O ® O AP A C O O 00 O 00 w . "'si: mN O W w 00 KA O O O O O O O O O UQ N N N N N N N N C9 ON <71 T ON Qs ON 01 ON Qr 00 00 00 0o 00 00 00 00 A A A A A A A A A O O O O O O 00 El O W W W W C.J W W W W W W W W W W W W W W W W W W W O D W a a a x > a x a a a a a aID z 7- d :3 �. m C7 d Z �• �. d d d CJ a 77- c vo ao Ta y c c v1n c� � -� _ << Z 3 lD N fD O. O. UQ N N nCD 77 � CD ? Fav v < n [�7 3 z G� n c oa — C� W N O C� W N O cn G1 W 00 Vi Oo Oo O O c o o 0 0 — c c 0 0 L, v o o oo oo m = n OfD O N O p G CD G yQo� C p O � 0 C C D � p K r r r 1- 0000 ❑ ill000 ❑ 000011 1 0000 w 3 (71 C N .O I b 'O In A w N to A w W fD A fD 7 7 7 R R R a > x a > a x _a > _a x ..+• A� iv �, y O d x � �• � d d w ,�• �• � d d � o �' � CD uzq = = QCD CD CD n m CD CD w 0 0 `bcn CD CDb `b 3 CD 3 CD CD �n Co �o 3 y ^ -o v� a Ln L'o w m co a 'C '7 Cy C C b CD C J 7 A .t ?a C 7Q CD O N n 00 In O y p O O O V y p O w y p wjy o0 f 9 0 � � v o 0 0 s CD ® A CD o •- c � cCD 0 0 a o m' o o is toCo' A o o n o „ m 0 o v, o o ° o o o w CN o o o w o o p UQ O CD R .. O C O C O C O � � 0 � C O � � y ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ a w D D x C� CD n n CD �• = CD QC UQ O O _ /] V) rDCD `d O N N CD CD o C ('� - O O f9 (I'a CDS � O CD •D a f9 x � rD z rn W o - Z r o o m s o o � n U3 o b M 0 0 o 0 0 0 v o rD 0 0 '< U3 vw Q C o C _ v n T < p < O rD o O O 3 0 CD v r p o o C o 3 a v O r 0 N W W 7 N O 00 J a\ CA J. w N C7 tTi b7 m Cil b7 ti7 til C�7 Cn Cn v t7 r r r r r r rr C—; r t; r UQ r' a5 � d� g u� 0 3 A (D CD 00 �l O w w CD CD CD CD a. m CD. CD. 0 0 oo o _ C � C=CD 51 C&Cl O& .01 CD O CD n co 13 CD CD CD n (A y C vii � n N (D � CD LO `G O UQ UIQ y o CD Co 0 oCD 0004, y w 'rJC.D m oo � � fD eC�D o o Oq rr. tz O O Q O O C D A O O p p E � S O N N CN .p G 0 00 CN O� .+ W O\ O O� O D O O O U O U 0 0 p O O < O O N Z w LA w 00 44. O N N :D W O� O N d O O O C O O 0 0 p ^ y p O O Cl O O O O O p p � o aaay Ln 0 0 0 0 0 0 0 0 0 0 0 D C D o C C 0 0 0 0 0 0 0 0 0 C 0 O 0 0 O o y o 3 3 3 3 3 V1 CD CD fD CD N 0 0 0 0 (D c� nn �] o y O O O O O O O C O O O Z C Q, •� w C N O O O N O O O O O O O C O O O O C OO O C O O O O O O O _ 3 0. N y W u y 'TS 'O 'C 'C CD 7C7 767' 00 P� Oo a a a O O00 H 000 O W N y -(i (D O N Q `n � rCC Q '� C �rorr++ . 2. n 'O chi O cD O r. c9 Q G Ci7 C n a C r+ CD O. CD �" IrD C) OG ::� Nyy 77 z CD cC CTi b Q fD. G N O 04 t y ..� 00 '�" �, -TI b Q CC CD M rrl "TI -n ' CD co d C7 O 0 O C O O y O O O O O O A ID CD' d 77 O -� O c a p � O 3 V1S ~ 7 y C z A N O O O O O O W O O S O 0 O 0 Cl 0 0 0 O ..j O W O Cl 0 0 0 S O O p O O O O O O N n 00 O 0 0 (Op O N W J O O O vi O tnD O '17 ITI O OQ T"' O O O O O1 C O Cl O O C cn ? n A C Cl O O O y y 00 O 00 O T1 K TJ wn _ v CD O N A -0110 O O n 0 0 LLE0ED 0o co 00 0❑ 0000 ❑❑ ❑ 0000❑ ❑ z o z o z .N`.. O 00 O o w p w c m o z a � o �, w e� C) _ y 0 r �1 Q1 Vi A w N V' N A -s a S fD `D N oo O A O Z �• W 00 p f9 N J v in Ow OCD47D n O O G7 d d CD 3 0 = Cn w 0 Z cn C ' NCD = ,< fD a b Z s C rro a 0 oo b -e CO A N C I'D O C r9 O G'1 n 3 C O UQ ny C O A fD O C A A J J � W � _ �••� fOD ("� p y n C. p C C r) O O O O O O O '► �. O O p O 7Q � CD N CD d n w ? S � C C r zoN W N p O y w ° 3 A r _ 00ar �t o o ,z3 z N A7 A 3. N �. d (D N A, O O ?: z CD z A N rfl C) C � � oa N z �- y O O O O S M ® 00 O O rD � O o s e � y M ;-y Gil � Z O O O O O O O O y n O O O OfD O O O O O Z M C N vim, y `i7 n � v o S w � C C � N El ❑ ❑ ❑ 1111 ❑ rt1=�Jjlj_ rCity of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) r 800 Seminole Road f?r( g 89 291 _ Atlantic Beach, Florida 32233-5445 0 d D 2• Phone (904)247-5826 • Fax(904) 247-5845 JE-mail: building-dept@coab.us Date routed: 12- 1 71 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �+ ! Y�- �f Cr'�i d D epartmenteview required Yes No Applicant: Project: / V Lu ;� -72 blic Works ublic Utilitie / s d G`p f V a-' 0,6 yl� y ublic Safety Fire Services (fid.IJIr 13_/000'Y L u„ - Review fee $ Dept Signatur Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: /Z—2_0-/,3 TREE ADMIN. Second Review: ❑Approved as revised. [-]Denied. Comments: ?—ALtETY PU LIC Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14109 NT pUgL[..c UTILITIES PLAN R'EVIE � � Initials: � Date: QlA a ✓, Application Permit#: Project dame/Address: ! V Check Box Check to Add Box to Application Tracking Comments Comment "Print" UWSU Avoid damage to underground water/sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5834. MBSC all meter boxes, sewer cleanouts and valve covers are set to grade and visible. Ensure to be opeIset to grade and visiblecovered wit rty ine. Cleanout mut be ❑ ❑ RTIC A sewer cleanout must be installed at thepr an RT1 concrete box with metal lid. Cleanout RPZB A reduced pressure zone backflow preventer must be installed if irrigation will be ❑ provided or if there is a private well on the property. Backflow preventer must be tested ❑ by a certified tester and a copy of the results sent to Public Utilities. STRM Plans note the building will be unsprinkled. If plans change, any fire line installed must be vault and an ro riate ❑ ❑ metered with a Sensus touch-read Backflow preveproperly a pmust betested by a certified tester and backflow preventer instal a copy of the results sent to Public Utilities. FSBR sprinkler system is provided, contact Malcolm Clemons at 247-5839 for backflow ❑ ❑ If fire sp requirements. At a minimum,will require a double check backflow preventer. FLM Fire lines must be metered with a Sensus touch-read meter. Meters larger than 2' must ❑ ❑ be installed in a vault as noted in JEA specifications. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yjy�,vr�� City of Atlantic Beach A APPLICATION NUMBER s� Building Department C/ (To be assigned by the Building Department.) r 800 Seminole Road 3— 0 Ode 2 �r Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us ���(' Date routed: 12-1171 City web-site: http://wvfw.coab.us APPLICATION REVIEW ALD TRACKING FORM Property Address: JJ11CA_"At?J21'?7 A � artm t review required Yes No p Y B ' Applicant: Fining &Zoning 7e dminis rator Project: �t'yl' L �2) ublic Works u lic Utilities 14-6 . g/v a—,, 0/6k-7;-{ry ublic Safety Fire Services e� 7 & ik6 / Review fee $ r'�6 Dept Signature Other Agency Review or Permit Required Review or Receip of Permit Verified Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b ' I&fDate: 13 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. [—]Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER S r. � Building Department (To be assigned by the Building Department.) r 800 Seminole Road �� Atlantic Beach, Florida 32233-5445 /� :% " Q Phone (904)247-5826 • Fax(904) 247-5845 LM19 E-mail: building-dept@coab.us Date routed: 12 7 f J City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ��/i��- L i'7�Q De t review required Yes No p Y Applicant: nA+ -8��oning -Tree"Adm—in is rafor ublic Works Project: /'V * Lublic Utilities``' . /V aL, d�"7j r �/ Public Safety J Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. (Circle one.) Comments: -. BUILDING gg � PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: [Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: LReviewed by: Date: Revised 05/14/09 PUBLIC WORKS PLAN REVIEW COMMENTS �II/I,1I Initials: PN /� ML Date Project Name/Address: '�� �� C( V Application Permit#: '3 DoDD Check Box Check Application Tracking Comments to Add Box to Comment "Print" IMPS Provide table of impervious surface calculations for entire lot (existing and post ❑ ❑ constructic n). ESCP Provide erosion and sediment control plans with installation details and maintenance ❑ ❑ schedule. DPLN Provide drainage plans showing site topography(flow arrows, etc.) ❑ ❑ CSMP Provide construction site management plan, including Right-of-Way Permit if using ❑ ❑ right-of-way for construction parking. TSUR Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1' contours. _DCS Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume ❑ ❑ calculations and on-site retention required per Section 24-66(b). (See attached information sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper ❑ ❑ construction will be required. RWPM A Right-of-Way Permit must be obtained for use ❑ ❑ REPM A Revocable Encroachment Permit must be obtained. ❑ ❑ PLWP Pool—Wellpoint (if used) must discharge into vegetated area 10' minimum from street or ❑ ❑ drainage feature (swale, structure or lagoon). _APR All concrete driveway aprons must be 5"thick, 4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6" thick). URCT Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. ❑ ❑ ROFF Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle's and Waste ❑ ❑ Management) ECIN Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control ❑ ❑ Inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed ❑ ❑ construction. Call 247-5834 to make an appointment. y6-t-F .e L. Ke xv, Cl ❑ ❑ ❑ I Carper, Rick From: Carper, Rick Sent: Friday, December 20, 2013 3:33 PM To: 'Pete Rodrigues'; kelly@kellyelmore.com; Kellmore; 'Glynn Taylor' Cc: 'Rick Wood'; 'Alex Acree'; Griffin, Michael; Hubsch, Jeremy; Walker, Jennifer; Graham Shirley Subject: Selva Marina Drive Entrance Modifications (Permit applications 13-00002 and 13-100098) Attachments: City Review Comments_ABCC clubhouse_carper.doc Pete, addressed to you since your name is on the permit applications. Glynn & Kelly, to you since your names are on the Civil and Landscape plans respectively. Major issue (that should have been caught on my initial review of plans) is removal of 30" and 40" Live Oaks that will be required for proposed new crossover locations in Selva Marina Drive median. By size these trees meet definition for Heritage trees in Chapter 23, and mitigation will be 3" for each 1" removed. Rick Ricky L. Carper, P.E. Public Works Director/City Engineer City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 rcarperCcDcoab.us PH: (904) 247-5834 Fax: (904) 247-5843 Florida Public Works-First to Respond, Lost to Leave www.apwaflorida.com i D00 O 0 <D N y 0 rn :? (D D a 3 7 rt_ CD � CD " � 0 W N m Nto W < (D m CD K a� D o o Z —� N n3 p � — � o_ r 0 -0 Sn � � 3 o i � - f?� � r CD `° � � v `° co 330 <cn � o0CD mr. mov °a � c'nD OTD CD CD 3 c<D v o o m = o ° m 0 c- 0 - v 0 ? Q O Z co 33 � c� oo 00o � c0 Z3 (nnjcn oo =hs (n r+ � � Z3 0 0- � CD v : w0 Qoo 3 0 o QpJ. Q '. n Q. C n � CD D � �. cCD CDn o (n =3 < ° p � 3 00 o m � a)i r � M v � 000 = �DOCDm �' CD � � X00 _ v 0 C) m � _ � � � � v (D CD— 3vv � CDCD � D CD 0 2.� o < o ID r-- 30 n 0 Z3 X CD cocDW.� mQD. oa � op-0 v0� n' 3 (D a9° 0 N con con cD . con o- o 0 c — CD <0 CDw �7 0 m 0 C W �' o ni 0 o m 3 N cn m 0 3 C) Ov z cn _ IT 0 0 c 0 o o Do m � ° 3 — (n vn mNmcD �'. � � � ocnmo 00cn : cD � � ° � CD o � � 3 --0 '" 0 na v 0 0 co 0 0 c 3 o o a < 0 0- Z3 cn o � m � ocCD w � cl) �Dv 0 0 0 3 w0 � �0 CD o o 0 v n � < o C:, Q o < cD (D vq o SCD ( � m � 0 (D �' � �' m � � 0 c wv m mv � � � � mo c 00mvo o (A Q cn 5 o w n - � v - 0 3 x0 ma o o v o o� 3• co v 3 0 v� 0 0 � � m Z) cv ca o cQ < CD " 2) Q 0 0 CD v Z — < a T 2) m C m m 0 m � cnO O c 0 z 00 Z n ch 0 m zz � --I Cl) D 0 O Z O z r z ;ovv `n <. M CD0m D _ C 7 O 2) CD z 77 0 °- CD X 0 -- N cn A) N O p o C CD N � � O Z Ill Taylor White, Inc. Civil Design b Consulting Engineer January 15, 2014 City of Atlantic Beach qN 29 Public Works Department eY X04 800 Seminole Rd. Atlantic Beach, FL 32233 Attn: Rick Carper, P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required, along with mitigation for removal(3"to 1"for removal of heritage trees from ROW, i.e., LO=>30"). Response: Please see plans and response from Kelly Elmore. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval, if different. Response: The pavement section on sheet No.28 has been specified for use within the clubhouse and Selva Marina Dr. median. Please see revised sheet. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present, but if found when pavement removed, it will also require removal before planting. Response: Please see plans and response from Kelly Elmore. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Please see plans and response from Kelly Elmore. The changes made to the building drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Taylor& White, Inc. AleAAcree, E. Project Manager Taylor fi Whit¢, Inc. Civil Design Ei Consulting Engineers January 15,2014 City of Atlantic Beach Public Works Department 800 Seminole Rd. Atlantic Beach,FL 32233 Attn: Rick Carper,P.E. Re: Atlantic Beach Country Club—Clubhouse and Landscape Dear Mr. Rick Carper: The following are our responses to your Public Works plan review comments(dated 12-20-13). 1. Comment: Proposed relocation of driveways/crossovers on Selva Marina Drive will require removal of two Live Oaks(-40"and—30")and one 12"palm tree. Tree removal permit for removal from City ROW required,along with mitigation for removal (3"to 1"for removal of heritage trees from ROW, i.e., LO=> 30"). Response: Please see plans and response from Kelly Elmore. 2. Comment: Plans should specify that pavement section detail on sheet 20 applies for SM Drive crossovers or submit proposed pavement section for AB approval,if different. Response: The pavement section on sheet No.28 has been specified for use within the clubhouse and Selva Marina Dr. median. Please see revised sheet. 3. Comment: Landscape plans do not include proposed restoration of ground under removed crossovers(sod,trees,etc.). (Civil plans sheet 29 notes sodding only for north crossover, southern not addressed). Probably no limerock present,but if found when pavement removed, it will also require removal before planting. Response: Please see plans and response from Kelly Elmore. 4. Comment: Irrigation plans not included in submittal to PW. Developer/ABCC will be responsible for watering and maintenance of all plantings in the ROW along Country Club frontage and for maintenance of the irrigation system. City will assume responsibility for grass and trees in median when well established. Response: Please see plans and response from Kelly Elmore. The changes made to the building drawings in response to these comments have all been clouded and marked as Revision Delta 1. Please feel free to contact me if there are any further questions or comments. Respectfully, Taylor& White, Inc. Alex Acree, .E. Project Manager 4� MCVEIGH&.MANGUM , E NGINEERI NG - INC THRESHOLD REPORT PROJECT: Atlantic Beach Country Club OWNER: Atlantic Beach Partners, LLC MME PROJECT NO.: 14025 LOCATION: Atlantic Beach, FL ARCHITECT: Cronk& Duch Architecture PERMIT NO.: 13-3848 ENGINEER OF RECORD: Wayne D. Mangum, P.E. REPORT NO.: 001 CONTRACTOR: RPC General Contractors, Inc. INSPECTION: PERSONNEL PRESENT: DATE: 2/25/2014 Mike Johnson- MME TIME: 12:15 pm - 12:45 pm Bob Grant- RPC WEATHER CONDITIONS: 75 -F± clear GENERAL PROJECT PROGRESS&OBSERVED WORK IN PROGRESS: Observed all isolated footings except for at the drive through canopy. DEVIATIONS/DEFICIENCIES OBSERVED& RECOMMENDEDCORRECTIVE ACTION: No deficiencies observed. STATUS OF CORRECTIVE ITEMS OR DEVIATIONS PREVIOUSLY REPORTED: REPORT& ITEM NUMBER CORRECTIVE ACTION COMPLETED (X) REMARKS: STRUCTURAL • MECHANICAL - ELECTRICAL • PLUMBING • LEED • COMMISSIONING • BIM 9133 R.G. Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 • www.mcveighmangum.com ATLANTA, GA • CHARLOTTE, NC • JACKSONVILLE, FL r tttgtattna+ttu+tur,� Respectft jwst is; McVeia. ii e1ig, Inc. Y • Tim 6 Thres ,'of B ild�� IQ�pps o*r cord '� iY r°�:♦ Florida Retrjtttttt; J 'spector No.: 1161 Mike Johnson, . . Distribution: Contractor: Engineer: Pete Rodrigues Wayne D. Mangum, P.E. pete@rpcgc.com wmangum@mcveighmangum.com Bob Grant bobg@rpcgc.com Architect: Cliff Duch Jennifer Snow cliff@arch-cd.com jennifer@rpcgc.com Building Official: Owner: Mike Griffin Rick Wood City of Atlantic Beach, FL Atlantic Beach Partners mgriffin@coab.us rwood@wooddev.net STRUCTURAL • MECHANICAL ELECTRICAL • PLUMBING • LEED COMMISSIONING BIM 9133 R.G. Skinner Parkway • Jacksonville, FL 32256 • (904)483-5200 www.mcveighmangum.com ATLAIwTA, GA • CHARLOTTE, NC • JACKSONVILLE, FL rS 1,,r�1�jr�J CITY OF ATLANTIC BEACH S 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 13-00003848 Date 6/20/14 Property Address . . . . . . 1600 SELVA MARINA DR Application type description COMMERCIAL NEW CONSTRUCTION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 5732911 ------ - - - ------- -- -- -- -- -- --- --- - --- - --- - --- --- -- - - -- - -- -------- - ------ Application desc NEW AB/SELVA CC BUILDING ------------- -- --- -- -- -- - --- - -- - --- - --- - --- --- -- - - - -- -- - -- - - ----- --- Owner Contractor - ---- --- -- --- -- - --------- - - - ----- -- --- -- - -- --- -- SELVA MARINA COUNTRY CLUB RPC GENERAL CONTRACTORS 1600 SELVA MARINA DR 248 LEVY RD ATLANTIC BEACH FL 322335616 ATLANTIC BEACH FL 32233 (904) 241-4416 -------------------- - Structure Information 000 000 -- --- ----------------- Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . ASSEMBLY Flood Zone . . . . . . . . ZONE AE ------------ --- -- -- -- -- -- ----- - --- ----- ------- -- ------- --- - -- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Sub Contractor . . WEATHER ENGINEERS INC. Permit Fee 855 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/17/14 ------------- -- - - - -- -- - -- --- --- - ---- --- - ------ ----- -- -- - Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible . A sewer cleanout must be installed at the property line . Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS 1'1✓Rit4f`P'IS-A1�l�ROVEe 8'�LJILIN Art'f'BI�177\fVeLt't"1'I`I'H-AY.t.�.'t"P1`(�I'tCP1_.�!'C"I'1C T3�:C('TI-(TItDi1'l�"CF.S A1VD-I'HE�LQRIII.�------- BUILDINIEk-(Mtkir.� Fees STATE MECH DCA SURCHARGE 12 . 83 ! =Lv1:r �� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j � ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00003848 Date 6/20/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DBPR SURCHARGE 12 . 83 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 855 . 00 855 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 25 . 66 25 . 66 . 00 . 00 Grand Total 880 . 66 880 . 66 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITU OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 ` JOB ADDRESS: I�a b_1 C kL PERMIT# 1_3 _ J b U PROJECT VALUE $ ARI& a �iC� .Q, REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEMI 1 ALLATION 72_5—t6tAI- Air Conditioning: Unit Quantity�� Tons Per Unit _l`� Heat: Unit Quantity BTU's Per Unif� Seer Rating Duct Systems: Total CFM REQVIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any cher state or local law regulation construction or the performance of construction. Property Owners Name C '�C J�`H D� L LO . Phone Number yy ���� �a Mechanical Compan}�JV134 C Office P o e Fax 3' " ?�� . � Cit Statt� Zi�)g% XL 1 Co. Address: yp License Holder (Print), � State Certification/Registration eny Nota -PIP ifton, TERRY L.PARRISH Notary Public State of Fla e me this S SL—day o 20 1 My Comm. Expires Oct 31,2016 ;Q, Commission # EE 8"80Eig ture of Notary Public i Ulm smal C E RT I F I E . � www.ahridirectory.org certificate of Product Ratings AHRI Certified Reference Number: 7056512 Date: 5/14/2014 tStatus: Active Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Model Number: TWA120D3**A* Indoor Model Number: TWE120D300A* Manufacturer: TRANE �- Trade/Brand name: TRANE Series name: ODYSSEY Rated as follows in accordance with AHRI Standard 340/360-2007, Commercial and Industry Unitary Air-Conditioning and Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Refrigerant Used: R-41 OA Cooling Capacity(Btuh): 120000/120000 EER Rating (Cooling): 11.00/11.00 IEER: 11.8/11.8 Heating Capacity at 47F (Btuh): 105000/105000 COP at 47F: 3.30/3.30 Heating Capacity at 17F (Btuh): 75000/75000 COP at 17F: 2.20/2.20 Full Load Indoor Coil Air Quantity: 4000 The AHRI 340/360 certified EER ratings in Btu/h/W are calculated under the same methodology as the EER ratings at T1 conditions of ISO 5151:2010 and ISO 13253:2011. Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and as no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridIrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AM AIR-CONDITIONING,HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahriditectory.org,click on"Verify Certificate"link we masr life bet er, and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 130445619346653462 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: ii Un rr tow 003 CERTIFIED s certificate of Product Ratings AHRI Certified Reference Number: 5269955 Date: 5/14/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWB3030C1 Indoor Unit Model Number: GAF2AOA24S21+TDR Manufacturer: TRANE Trade/Brand name: XB13 WEATHERTRON Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 30200 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 13.50 Heating Capacity(Btuh)@ 47 F: 29600 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 16800 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alterationof data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridireetory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and AM confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information far the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we.malke li!e letter"' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, __........ which is listed above,and the Certificate No.,which is listed at bottom right. 130445613755385780 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: CERTIFIEDO www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 6059559 Date: 5/14/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWB3036C1 Indoor Unit Model Number: GAF2AOA36S31+TDR Manufacturer: TRANE Trade/Brand name: XB13 Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 34000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 33400 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 23400 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrldIrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and M confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING.HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 130445615637081904 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: CERTIFIE ,° www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 7056516 Date: 5/14/2014 tStatus: Active Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Model Number: TWA180E3**A* Indoor Model Number: TWE180E300A* Manufacturer: TRANE J Trade/Brand name: TRANE Series name: ODYSSEY Rated as follows in accordance with AHRI Standard 340/360-2007, Commercial and Industry Unitary Air-Conditioning and Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Refrigerant Used: R-41 OA Cooling Capacity(Btuh): 180000/180000 EER Rating (Cooling): 10.60/10.60 IEER: 12.3/12.3 Heating Capacity at 47F (Btuh): 174000/174000 COP at 47F: 3.20/3.20 Heating Capacity at 17F (Btuh): 109000/109000 COP at 17F: 2.30/2.30 Full Load Indoor Coil Air Quantity: 6000 The AHRI 340/360 certified EER ratings in Btu/h/W are calculated under the same methodology as the EER ratings at T1 conditions of ISO 5151:2010 and ISO 13253:2011. Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; AM entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING.HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"verify Certificate"link we make We..better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 130445620663622346 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: CERTIFIEDALM � U www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5863458 Date: 5/14/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWB3042131 Indoor Unit Model Number: GAM5BOC42M31 Manufacturer: TRANE Trade/Brand name: XB13 WEATHERTRON Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 42000 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 39000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 25600 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrid ireetory.or,. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not.in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized.in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we maize life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No..which is listed at bottom right. CERTIFICATE NO.: 130445616996639334 ©2014 Air-Conditioning. Heating,and Refrigeration Institute IED 011 r rr Ir MRS --� L A 0 an IL certificate of Product Ratings AHRI Certified Reference Number: 5720611 Date: 5/14/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWB3048B1 Indoor Unit Model Number: GAM2AOC48S41+TDR Manufacturer: TRANE r Trade/Brand name: XB13 WEATHERTRON Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 46500 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 45000 Region IV HSPF Rating (Heating): 8.50" Heating Capacity(Btuh)@ 17 F: 30800 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AM AIR-CONDITIONING.HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we.male life.better"' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, _...___ 1.11 which is listed above,and the Certificate No.,which is listed at bottom right. 130445617865882478 ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: -RP General Contractors, Inc. 248 Levy Rd. P.O.Box 330775 Atlantic Beach, FL 32233 (904)241-4416-(904)241-4427fax August 25, 2014 Dan Arlington City of Atlantic Beach Building Department 800 Seminole Rd. Atlantic Beach, FL 32233 RE: Building Permit#13-00003848,Atlantic Beach Country Club Dear Mr.Arlington: Effective immediately, please remove the roofing company listed on our building permit#13-00003848, Ford Roofing Systems, 1216 N. Burgundy Trail,Jacksonville, FL 32259. Ford Roofing Systems is no longer providing the roofing scope of work for the Atlantic Beach Country Club located at 1600 Selva Marina Drive,Atlantic Beach, FL 32233. If you have any further questions or require any further documentation, please feel free to contact me at any time. Sincerely Peter J. bes � President Cc: file Aug. 26 . 2014 12 :24 PM FORD ROOFING SYS . 9044618453 PAGE. 2/ 2 ■ � , lJ CCC1327698 August 26", 2014 City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 Attn.: Shirley Graham Ms. Graham, Please let it be known the Ford Hoofing Systems Inc. is no longer the contractor of record for the roof installation on Atlantic Beach couitry Club, The address is as follows: 1600 Selva Marina Drive Atlantic Beach, FL 32233 Sincerely, Robert Maust President Ford Roofing Systems Inc. Florida State Certified Roofer CCC1327698 Ford Roofing Systems Inc Phone:904-471-2819 1216 N Burgandy Trail Fax:904-461-8453 St Johns, FL 32259 Graham, Shirley From: Jennifer Snow [Jennifer@rpcgc.com] Sent: Tuesday, August 26, 2014 9:28 AM To: Graham, Shirley; Catherine Lewin; Walker, Jennifer Cc: Pete Rodrigues; Danny Rodrigues; John Meserve Subject: RE: Atlantic Beach Country Club Permit# 13-00003848 Shirley, The only thing they have installed is the peel & stick and the flat roof area. Thank you, Jennifer Snow Senior Project Manager Assistant RPC General Contractors, Inc. 248 Levy Road Atlantic Beach,FL 32233 (904)241-4416(904)241-4427 fax ICBE 2.i —RP ;� a ennifer(o)rpcgc.com www.rpcqc.com This e-mail is intended for the addressee shown.It contains information that is confidential and protected from disclosure.Any review,dissemination or use of this transmission or its contents by persons or unauthorized employees of the intended organizations is strictly prohibited. VA If you must print this email,please recycle. From: Graham, Shirley [mailto:sgraham coab.us] Sent: Tuesday, August 26, 2014 9:13 AM To: Catherine Lewin; Walker, Jennifer Cc: Jennifer Snow; Pete Rodrigues; Danny Rodrigues; John Meserve Subject: RE: Atlantic Beach Country Club Permit # 13-00003848 Cat, We need a letter from Ford roofing stating they are no longer the contractor of record they can fax it to 247 5845. Have they done any work yet ? ski%rLelu c,raham C,tU c f AtLawtic"each Building Permits Technician Atlantic Beach, Fl 32233 904 247 5800 sgraham@coab.us From: Catherine Lewin [mai Ito:Catherine@rpcgc.com] Sent: Monday, August 25, 2014 4:01 PM To: Graham, Shirley; Walker, Jennifer V, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 MECHANICAL GAS PIPE PERMFECTION PHONE LINE 247-5814 J=i CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job - - Job Type: MECHANICAL GAS PIPING Description: GAS PIPING 17 OUTLETS Estimated Value: Issue Date: Expiration Date: PROPERTY ADDRESS: Address: 1600 SELVA MARINA DR RE Number: 169399-0000 PROPERTY OWNER: Name: ATLANTIC BEACH PARTNERS, LLC Address: GENERAL CONTRACTOR INFORMATION: Name: FIRST QUALITY GAS, INC. Address: Phone: - - FEES: Gas Pipe Outlets $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $83.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 80( Seminole Rd Atlantic Beach, FL 32233 2 f Ph (904) 247-5826 Fax (904) 247-5845 1-� lam- J 1� JOB ADDRESS: _ 1y 1 ' ` ` G, V _PERMIT# PROJECT VALUE $ �• w ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & � EATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity_ BTU's Per Unit Seer Rating Duct Systems: Total CFM _ REQUIRED FIRE PREVENTION Fire Sprinkler System Q11 'tity (Requires 3 sets of plans) Fire Standpipe Qi: `ity (Requires 3 sets of plans) Underground Fire Main Va.. ti (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty, Automobile Lifts Gas Piping Outlets _ Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets _ Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters _ Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the prtrvisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company ��tt�SJ- G�U�, ,-t s `� -� Office Phone ax Co. Address: O JROX 16, 3 0 3 City h StateF-1L7Zip 3.22 License Holder (Print): S to Certification/Registration#-41,4�— Notarized Signature o License Hol -t v v v ~ (4 Z v 6- ✓� JENNIFER WALKERefore me this day of 20 ( Ll MY COMMISSION#FF 011480 '-.• -a EXPIRES:April 24 2017 Public ''?pF F g",• Bonded Thru Notary Public Underwriters 1gn .re of Notary 384b From:Gale, Harold T. [mailto:GaleHTPiea.com] Sent: Friday, September 05, 2014 8:18 AM To: Pete Rodrigues Cc: Bobby Grass(bgrass P american-electrical.com) Subject: Fault Current for ABCC- 1600 Selva Marina Drive Pete- The fault current for a 300 Kva, 208 volt transformer for the above referenced project is 23,068. If this is not adequate documentation for Mr. Arlington, I will send you a formal letter next week. Thank you, Harold T. Gale (904) 665-4191 -----Original Message----- From: Pete Rodrigues [m ailto:Pete(@rpcgc.com] Sent: Wednesday,September 03, 2014 1:04 PM To: Bobby Grass Cc: Gale, Harold T. Subject: Re: Pwoer For ABCC Harry Dan Arlington ( Building Official) is onsite and is asking for a Fault Current letter he's requiring from JEA Is that letter available? Pete Rodrigues, President RPC General Contractors, Inc. The 1200 amp main breaker was inspected by Dan Arlington and the fault current rating for the breaker is 85,000amps. 85,000 A is greater than 23,068 A OK Dan Arlington 9/05/14 FLvR- flA ?�_oouc i AQPROVAL NICHIHA fiber cement Sierra PremiumTM Shake PLUS & Smooth Boards 1� 1 ASTM Test Performance Test Result i Standard ASTM C-1185 Wet Flexural Strength Avg.1450 psi ASTM C-1185 Moisture Movement Linear Change(%):0.098 ASTM C-1185 Water Tightness No water droplets were observed on any specimen. ASTM C-1185 Freeze-Thaw No damage or defects were observed. ASTM C-1185 Warm Water No evidence of cracking,delamination,swelling,or other defects were observed. R=0.98. ASTM C-1185 Heat-Rain No damage,cracking or structural failure were present on the sur- face of the tested sheets. ASTM E-84 Surface Burning Flame Spread: 0 Smoke Developed: 0 ASTM E-228 Mean Coefficient of Linear Thermal Ex- Avg.3.55*10 A-6 in./in.F pansion ASTM E-330 Wind Load 2x4 studs at 16"o.c.,7/16"OSB,blind nailed with one 6d nail at each stud. 1-1/4"overlap. Design Loads:* Positive: Avg.49.23 psf Negative: Avg.52.33 psf j ,I ASTM E-330 Wind Load 2x6 studs at 16"o.c.,7/16"OSB,blind nailed with 2"long screws at 8"o.c. 1-1/4"overlap. Design Loads:* Positive: Avg.136.07 psf Negative: Avg.92.33 psf ASTM E-330 Wind Load 2x6 studs at 16"o.c.,7/16"OSB,face fastened with#8,2-1/2" long wood screws at 8"o.c.,1 inch from bottom edge through itself and the previous course.2"overlap. Design Loads:* Positive: Avg.139.36 psf Negative: Avg.123.24 psf *Design loads based on 3.0 safety factor PAGE 14 NICHIHA TRAINER MANUAL