422 Sargo Rd 2014 HVAC CITY OF ATLANTIC BEACH SSS 800 SEMINOLE ROAD r� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 rJJ3l�� Application Number . . . . . 14-00000292 Date 3/03/14 Property Address . . . . . . 422 SARGO RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------- Application desc 1 cu 1 ahu ------------------------------------------------ Owner Contractor - ------------------------ ----------------------- HAAS, ELIZABETH DEL AIR ELEC SERVICES 422 SARGO RD 531 CODISCO WAY ATLANTIC BEACH FL 32233 SANFORD FL 32771 (407) 333-2665 --------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 95 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/30/14 --------------------- --------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ------ Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. �qq.�o MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: 14(22 aLim3d PERMIT# PROJECT VALUE$ -5ho. oo NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION LATIO q A Air Conditioning: Unit Quantity_ Tons Per Unit 5_ REQUIRED Heat: Unit Quantity f BTU's Per Unit 3p+coo_ Seer Rating_ /5 scar Duct Systems: Total CFM r000 REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.1 hereby certify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name '?�o4sLx ( cka f:) Phone Number X61 Mechanical Company bk—N Y Office Phone 585- ax, Co. Address: 58( �sCs3 WC.�� City e Zip 3 2-7-1� License Holder(Print). Certificatio e tration# :24q Notarized Signature of License Holder Sworn altd scribed before e c day 20 Signature of Notary Publi 11, nY hIIRINDA0.TURNCR COMMISSION f EE 096138 F'i{IES:June 14,2015 r I wand 1 tv Wiry PIW O undlorltdra Au9nwlkICERTIFIED�' www.ahridirectory.org certificate of Product Ratings AHRI Certified Reference Number: 3645739 Date: 2/27/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC530A**30 Indoor Unit Model Number: FX4DN(B,F)031 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Series name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.20* Heating Capacity(Btuh)@ 47 F: 28200 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 17000 'Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual.personal and AM confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual. AIR-CONDITIONING,HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life tetter and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 130380002632466066 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: Job: Bootsy Hass - d- wrightsoftx Project Summary Byte : JL67- 14 Entire House DEL-AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project Information For: HAAS ELIZABETH 422 SARGO RD,ATLANTIC BEACH, FL 32233 Notes: Design Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 OF Outside db 93 cF Inside db 70 °F Inside db 75 OF Design TD 38 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23657 Btuh Structure 17118 Btuh Ducts 5285 Btuh Ducts 6887 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28942 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24005 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1896 Btuh Fireplaces 0 Structure Ducts 1520 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft2) 1081 1081 Equipment latent load 3416 Btuh Volume(ft3) 9729 9729 Air changes/hour 0.45 0.23 Equipment total load 27421 Btuh Equiv.AVF(cfm) 73 37 Req. total capacity at 0.85 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 13 PURON HP Trade COMFORT 13 PURON HP Model 25HBC530A"30 Cond 25HBC530A"30 AHRI ref 3645739 Coil FX4DN(B,F)031 AH R I ref 3645739 Efficiency 8.5 HSPF Efficiency 12.5 EER,15.25 SEER Heating input Sensible cooling 24480 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 4320 Btuh Temperature rise 26 cF Total cooling 28800 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Feb-27 14:07:34 wrightsoft` Right-Suite®Universal 2013 13.0.08 RSU07938 Page 1 �� ...tail Projects to do\Bootsy Haas\Bootsy Haas.rup Calc=MJ8 House faces: E AED Assessment Job: Bootsy Hass s - - wrightsoft` By: 2-27-14 Entire House y DEL-AIR HEATING & AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM • Mon. • For: HAAS ELIZABETH 422 SARGO RD,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Intl AR FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD (°F) 38 18 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 11.0 51.2 Dry bulb(°F) 33 93 Infiltration: Daily range(°F) - 18 ( M ) Wet bulb(°F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Hourly Glazing Load 9,000— 6,000 7.000 6,000 5,000-- 4,000-- 3,000-- 2.000-- 11.000- 0 ,0004,0003.2,0001,000 0 8 9 10 11 12 13 14 15 16 17 18 19 20 r� DD' nEo� iwa Maximum hourly glazing load exceeds average by 14.9%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh 2014-Feb-27 14:07:34 L wright:SOft' Right-Suite®Universal 2013 13.0.08 RSW7938 Page 1 fllls�tX.P� ...tail Projects to do\Bootsy Haas\Bootsy Haas.rup Calc=MJ8 House faces: E wri htsoft Right-J@ Worksheet Job: Bootsy Hass 9 g Date: 2-27-14 Entire House By: SLB DEL-AIR HEATING &AIR C� NDIT�ININ�a 531 CODISCO WAY,SANFORD,FL 3277 one:40 -3 3-2665 ax:407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Entire House Whole House 2 Exposed wall 118.0 ft 1 118.0 ft 1 1 31 Room height , 9.0 ft 9.0 ft heat/cool 23.0 x 47.0 ft 4 Room dimensions 1()81,0 ft2 1081.0 ft2 5 Room area Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh ftz°F) (Btuh ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-2ocs 0.201 n 7.54 4.24 225 207 1558 877 225 207 1558 877 L---G 1A-ctom 1.270 n 47.63 32.46 18 0 869 592 18 0 869 592 W 13A-2ocs 0.201 e 7.54 4.24 207 157 1183 666 207 157 1183 666 111, ��11A-clom 1 1.2701 e 1 47.631 75.481 201 075.48 9 1 9531 15101 20429 679 1 0 953 01 1 1510, 1 Ir—� 1 A Toms 4 4 40 s 473 381 47.631 12 21 12 32.461 4 2 3121 25721 371 139061 4221 3121 26572 94 1516 1 ,W 113A-2� 1 0.2011 w 1 47.54, 44.0241 2071 1951 124671 28261 2071 95 2553 2146 54 1951 14671 826 1.270 47.63 751D 1 DO sw 0.3907 n 14.621 11.781 12$1 1721 30771 ( 9247 21 21 307 247 299 1981 177 01 1 299 1 1 F 1122A cpld 0.049 84 2.63 1 0.9891 1 37.09, 0.001 10811 101181 11681 43761 X01 1081, 1011881 43761 X01 1 1 1 1 1 1 1 1 1 1 1 1 ( 1 1 1 1 1 1 1 1 1 1 1 1 ( 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ( 1 1 1 1 1 1 11 1 1 1 1 1 1 i 1 1 11 1 1 1 1 1 � 1 1 1 1 1 1 1 6 c)AED excursion 0 0 Envelope loss/gain 20651 13903 20651 13903 12 a) Infiltration 3006 725 3006 725 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 180() 180() Subtotal(lines 6 to 13) 23657 17118 23657 17118 Less external load () p 1 1 0 O1 141 Less transfer p p 0 0 Redistribution 1 I 1 23657 17118 236571 17118 Subtotal 15 Duct loads 220% 40% 5285 6887 22°/ 40% 5285 6887 Total room load 28942 24005 1000 21005 A r required(cfm) 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Feb-27 14:07:34 vvrightsoft Right-Suite®Universal 2013 13.0.08 RSU07938 Page 1 gyp` ...tail Projects to do\Bootsy Haas\Bootsy Haas.rup Calc-MJ8 House faces: E Job: Bootsy Hass - - wrightsoftx Manual S Compliance Report Date: 2-27-14 Entire House By: JLB DEL-AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project • • For: HAAS ELIZABETH 422 SARGO RD,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7 OF Sensible gain: 24005 Btuh Entering coil DB: 77.5°F Outdoor design WB: 77.1 OF Latent gain: 3416 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0 OF Total gain: 27421 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Cartier Model: 25HBC530A*'30+FX4DN(B,F)031 Actual airflow: 1000 cfm Sensible capacity: 23361 Btuh 970/.of load Latent capacity: 4203 Btuh 123%of load Total capacity: 27564 Btuh 101%of load SHR: 850/. Heating Equipment Design Conditions Outdoor design DB: 32.5F Heat loss: 28942 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0 OF Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH Manufacturer: Carrier Model: 25HBC530A*'30+FX4DN(B,F)031 Actual airflow: 1000 cfm Capacity balance: 40 °F Output capacity: 23274 Btuh 80%of load Economic balance: -99 IF Supplemental heat required: 5668 Btuh The above equipment was selected in accordance with ACCA Manual S. 2014-Feb-27 14:07:34 ,� - wrightsoft' Right-Suite®Universal 2013 13.0.08 RSU07938 Page 1 �+�- ...tail Projects to do\Bootsy Haas\Bootsy Haas.rup Calc=MJB House faces: E Job: Bootsy Hass - - wrightsoft Component Constructions Date: 2-27-14 Entire House By: JLB DEL-AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project • • For: HAAS ELIZABETH 422 SARGO RD,ATLANTIC BEACH, FL 32233 Design C• • • Indoor: Heating Cooling Location: Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD (°F) 38 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 11.0 51.2 Dry bulb(°F) 33 93 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain Construction descri P W Btuhmz F ftz-F/13a,h BtuhN Bwh BwhmV Btuh Walls 13A-2ocs:Blk wall,r-2 ext bd ins,8"thk,1/2"gypsum board int fnsh n 207 0.201 0 7.54 1558 4.24 87 e 157 0.201 0 7.54 1183 4.24 666 s 357 0.201 0 7.54 2694 4.24 1516 W 195 0.201 0 7.54 1467 4.24 826 all 916 0.201 0 7.54 6903 4.24 3884 Partitions 299 12B-Osw:Frm wall,r-11 cav ins,1/2"gypsum board int fnsh,2"x4" 177 0.097 11.0 3.64 644 1.69 wood frm Windows 1A-clom:1 glazing,clr glz,mtl no brk frm mat,1/8"thk;50%drapes, n 18 1.270 0 47.6 869 32.5 59 medium;1 ft overhang(3 ft window ht,1 ft sep.) e 9 1.270 0 47.6 429 75.5 679 all 27 1.270 0 47.6 1298 46.7 1272 1A-c1om:1 glazing,clr glz,mb no brk frm mat,1/8"thk;50%drapes, a 20 1.270 0 47.6 953 75.5 1510 medium;1 ft overhang(4 It window ht,1 ft sep.) 1A-clom:1 glazing,clr glz,mtl no brk frm mat,1/8"thk;50%drapes, s 12 medium;l it overhang(2 ft window ht,1 ft sep.) w 12 1.270 0 1.270 0 47.6 �6 F 72 32.5 0 87 75.5 931 all 24 1.270 0 47.6 1159 54.3 1320 1A-clomd:1 glazing,clr glz,mtl no brk frm mat,1/8"thk;1 ft overhang s 54 1.270 0 47.6 2553 40.0 2146 (6.7 ft window ht,1 ft sep.) Doors a 21 0.600 6.3 22.5 473 18.1 381 11J0:Door,mtl fbrgl type 14.6 307 11.8 247 11 DO:Door,wd sc type n 21 0.390 0 Cei 1 i ngS1081 0049 19.0 1.84 1986 2.63 2844 16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" . gypsum board int fnsh Floors118 0 989 0 37.1 4376 0 0 22A-cpl:Bg floor,light dry soil,on grade depth,carpet fir fnsh 2014-Feb-27 14:07:34 wrightsoft" Right-Suite®Universal 2013 13.0.08 RSU07938 Page 1 .1-M ...tail Projects to do\Bootsy Haas\Bootsy Haas.rup Calc=MJ8 House faces: E