465 Aquatic Dr 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000315 Date 3/07/14
Property Address . . . . . . 465 AQUATIC DR
Application type description MECHANICAL HVAC ONLY
Property zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
FALCON RICHARD & SONYA C ONE HOUR AIR
465 AQUATIC DRIVE 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 322333835 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . Plan Check Fee . 00
Permit Fee . . . . 91 . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 9/03/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: jb�5 �::)R PM PERMIT
4
PROJECTVALUE $ ARI#_��MJO -REQUIRED
Air Handling Equipment Only �-'Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit '2-- . 3
Heat: Unit Quantity BTU's Per Unit Seer Rating I
Duct Systems: Total CFM REQUIRED
Manual J documentation required on residential change out
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
4 Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name (::�A,�Y-A Phone Number
L
Mechanical Company nA.A(2- �—k U 9. �q Office Phone2LIL-S 167 Fax 2-q7-5 az 6
Co. Address: /199 TI CityorZ&A/L
A�&14 Statea -Zig32Z33-
License Holder(Print): CIZA I G, F k at ertification/Registration#c4clalLiq7-el
Notarized Si Uicauaffah&r.
A
A 0
SHIIRLEY L GRAH day
D rd e this /da 0
0 COMMISSION#DD
ry 1
EXPIRES:February 14,2014
I U=f
3onded Thru Notary Public'u ' i re of Notary Pub
Job: 127171
wrightsoft Right J@ Mobile Report Date: 3/612014
Entire House 13y: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FIL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC 1814420
Project Information
For: SONYA FALCON
465 AQUATIC DR,ATLANTIC BEACH, FIL 32233
Phone: 9045257554
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity 1(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Dailyrange ('F) - 17 ( M Method Simplified
Wet bu I b('F) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btu h/ft' Btuh %of load
Walls 8.8 7168 40.7 141trAcn
Glazing 19.7 3632 20.6
Doors 13.5 283 1.6 MIS Rocrs
Ceilings 1.7 1655 9.4
Floors 2.7 2634 15.0
Infiltration 2.2 2225 12.6
Ducts 0 0 Cdlirgs
Piping 0 0 T1,Qh3r
Humidification 0 0
Ventilation 0 0 Gairg
Adjustments 0
Total 17597 100.0
-Component Btu htff Btuh % of load
Walls 5.1 4185 21.6 Irterrd Gairls
Glazing 42.9 7905 40.7 wal
Doors 11.4 240 1.2 infutrabon
Ceilings 2.6 2525 13.0 ir Ro3s
Floors 1.0 974 5.0
Infiltration 0.5 536 2.8
Ducts 0 0
Ventilation 0 0 Cdlirgs
Internal gains 3040 15.7
Blower 0 0 Cayr
Adjustments 0 Ga&g
Total 19405, 100.0
Latent Cooling Load 2673 Btuh
Overall U-value =0.149 Btuh/ft-'F
Data entries checked.
2014-Mar-06 12:14:26
wrightsOft' Right-Su itec U niv ersal 2013 13.0.06 Right JV Mobile Page I
WOCA \wstmp\94f37ae3-lac4-4968-b732-e7fdd27e6aO6.rup CaIc=MJ8 FrontDoorfaces: N
Project Summary Job: 127171
wrightsoft, Date: 3/6/2014
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FIL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC 18 14420
Project Information
For: SONYA FALCON
465 AQUATIC DR,ATLANTIC BEACH, FIL 32233
Phone: 9045257554
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 *F
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17597 Btuh Structure 19405 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 17597 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19405 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2673 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area(ft2) 976 976 Equipment latent load 2673 Btuh
Volume(ft3) 7808 7808
Air changes/hour 0.45 0.23 Equipment total load 22078 Btuh
Equiv.AVF (cfm) 59 30 Req.total capacity at 0.80 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS
Model GSZ130241 Cond GSZ130241
AHRI ref 3842470 Coil AWUF240516
AHRI ref 3842470
Efficiency 0 HSPF Efficiency 13 SEER
Heating input Sensible cooling 18240 Btuh
Heating output 0 Btu h @ 47'F Latent cooling 4560 Btuh
Temperature rise 0 'F Total cooling 22800 Btuh
Actual air flow 883 cfm Actual air flow 883 cfm
Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Mar-06 12:14:26
-T� wriightSOft' Right-Suitee universal 2013 13.0.06 Right J�Mobile Page 1
\wstmp\94f37ae3-lac44968-b732-e7fdd27e6aO6.rup CaIc=MJ8 FrontDoorfaces: IN
wrightsoft, Right-M) Worksheet Job: 127171
Entire House Date: 3/6/2014
By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
I Room n me Entire House First Floor
2 Exposed wall 128.0 ft 128.0 ft
3 Room height 8.0 ft d 8.0 ft heaUcooi
4 Room dimensions 1.0 x 976.0 ft
5 Room area 976.0 ft2 976.0 ft
I 1 11 1
Ty � Construction U-value. Or HTM Area (w) Load Area (w) Lo a d
number �(Btuh/ftl_ F)i (Bt uh/f t 2 OF perimeter (ft) (Btuh) or perimeter (ft) Heat(Btuh)Cool
Heat I Cool Gross N/P/S Heat Cool Gross NIPIS
6 2A-Ob 0.253 n 8.75 5.11 256 188 1649 962 256 188 1649 962
11D-c2ovq 0570 n 19.72 209 1 47 0 920 976 47 0 920 976
11DO 0.390 n 113.49 11.43 21 21 283 240 21 21 283 240
1. V" 112A-0b O�253 e 8.75 5.111 256 210 1840 1074 256 210 1840 1074
1 D-c2ow 0.570 e 1972 63 0 46 0 904 2888 46 0 904 2888
2A-01b 0.253 s 8.75 5.11 256 210 1840 1074 256 210 1840 1074
t—G 11D-c2ow 0.570 s 1972 25.1 6 46 0 904 1 153 46 0 904 1153
1 2A-01b 0.253 w 8.75 5.11 256 210 1840 1074 256 210 1840 1074
t--" 1D-c2o 0.570 w 1972 63.01 46 0 904 2888 46 0 904 2888
C 16B-19ad 0.049 1.70 2.59 976 976 1655 2525 976 976 1655 2525
F 20P-1 lt 0.078 2.70 1.00 976 976 2634 974 976 976 2634 974
1 61 c)AED excursion 1 01 01
Envelope loss/gain 153721 158291 15372 158291
12 a) Infiltration 2225 536 2225 536
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 8 1840 840
Appliances/other 1200 11200-
Subtotal(lines 6 to 13) 17597 194051 17597 19405
0 0 0 0
Less external load 0 0 0
Less transfer
Redistribution 0 0
17597 19405 17T197' 19405
14 Subtotal _0% 0% 0
15 Duct loads 0% 0% 0 0 -
T tal room load 175971 194051 1 1 17597 19405
Aoir required(cfm) 1 1 883 883 883 8831
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Mar-06 12:14,26
Right-Suite@ Universal 2013 13.0.06 Right JC Mobile Page I
.\wstmp\94f37ae3-lac4-4968-b732-e7fdd27e6aO6.rup Calc=MJ8 FrontDoorfaces: N
Job: 1271711
Component Constructions Date: 3/6/2014
wrightsoft' Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
I Project Information
For: SONYA FALCON
465 AQUATIC DR,ATLANTIC BEACH, FIL 32233
Phone:9045257554
-Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature('F) 70 75
Elevation: 43 ft Design TD(*F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(*F) 35 91 Infiltration:
Daily range(*F) - 17 M Method Simplified
Wetbulb(*F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Or Area U-value Insul R Htg HTM Loss Cig HTM Gain
Construction descriptions ft2 Btuhffi2-'F fe-*F/Bbh Btuh/ft' Btuh Bbjh/fF Btuh
Walls 188 0.253 0 8.75 1649 5.11 962
12A-Obw:Frm wall,brk 4"ext,1/2"gypsum board int fnsh,ZW�' n
wood frm e 210 0.253 0 8.75 1840 5.11 1074
S 210 0.253 0 8.75 1840 5.11 1074
w 210 0.253 0 8.75 1840 5.11 1074
all 819 0.253 0 8.75 7168 5.11 4185
Partitions
(none)
Windows 47 0.570 0 19.7 920 20.9 976
1 D-c2ow:2 glazing,cir outr,air gas,wd frm mat,cIr innr,1/4"gap, n
1/8"thk e 46 0.570 0 19.7 904 63.0 2888
S 46 0.570 0 19.7 904 25.2 1153
w 46 0.570 0 19.7 904 63.0 2888
all 184 0.570 0 19.7 3632 42.9 7905
Doors n 21 0.390 0 13.5 283 11.4 240
11 DO:Door,wd sc type
Ceilings 2525
16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 976 0.049 19.0 1.70 1655 2.59
gypsum board int fnsh
Floors 974
20P-1 It:Fir floor,wd fir,1"thkrs,tile flr fnsh,r-1 I ext ins,amb ovr 976 0.078 11.0 2.70 2634 1.00
2014-Mar-06 12:14:26
wrI9htS0f11t* Rig ht-Su ite4D U niv ersal 2013 13.0.06 Right J8 W bile Page 1
Z5.1. ...\wstmp\94f37ae3-lac4-4968-b732-e7fdd27e6aO6.rup Calc=MJ8 Front Door faces: N
Job: 127171
wrightsoft AED Assessment Date: 3/6/2014
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD SUITE 1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC 1814420
Project Information
For: SONYA FALCON
465 AQUATIC DR,ATLANTIC BEACH, FIL 32233
Phone: 9045257554
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75
Design TID('F) 35 16
Elevation: 43 ft 50
Latitude: 30'N Relative humidity 30 52.8
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4
Dry bulb('F) 35 91 Infiltration:
Daily range(oF) - 17 M
Wet bulb(o F) - 77
Wind speed (mph) 15.0 7.5
Test for Adequate Exposure Diversity
Hourly Glazing Load
1 1'00� -.......------------ ..................................
10'00�---- -
9'00
"'00
7,00
6,00
5,00
4,00
3,00
2,00
1'001r
0 8 9 10 11 1 2 1 3
Hour of Day
Z HaFiy Ae-age AB:)IirTit
Maximum hourly glazing load exceeds average by 19.3%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2014-Mar-06 12:14*26
wrightsoft' Right-Suitee Universal 2013 13.0.06 Right J&Mobile Page 1
'I& \wstmp\94f37ae3-1 ac4-4968-b732-e7fdd27e6aO6.rup Calc=MJ8 Front Door faces: N
First Floor
..........
First Floor
Job 127171 ONE HOUR AIR Scale: 1 53
Performed by CRAIG EDDY for: Page 1
SONYA FALCON 1198 MAYPORT RD SUITE 1 Right-Suite&Universal 2013
465 AQUATIC DR ATLANTIC BEACH,FL 32233 13.0.06 Right J@ Mobile
ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 20i4-Mar-06 12:14:27
Phone:9045257554 ...-lac4-4968-b732-e7fdd27e6ao6.rup
CERTIFIED
www.ahridireetory.org
L
Certificate of Product Ratings
AHRI Certified Reference Number: 3842470 Date: 3/6/2014
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ1 30241 B*
Indoor Unit Model Number: AWUF24XX16B*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Series name: GSZ13
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh)-. 22800
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 23000
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh) @ 17 F: 13800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the prod uct(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe
un a uthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the
directory at www.ahridirectory.org. am
TERMS AND CONDITIONS Certificate shall only be used for individual,personal and
This Certificate and its contents are proprietary products of AHRI.This fln ted; VMM
confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;dissery 1.
entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individua AIR-CONDITIONING,HEATING.
pe rsonal and confidential reference. &REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory-org,click on"Verify Certificate"link we.mike lit�better"
and enter the AHRI Certified Reference Number and the date on which the certificate was issued, ................. I.............__ --
which is listed above,and the Certificate No.,which is listed at bottom right. CERTIFICATE NO.: 130386093876276258
@2014 Air-Conditioning, Heating,and Refrigeration Institute