525 Ocean Blvd 2014 HVAC CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD j } ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000333 Date 3/11/14 Property Address . . . . . . 525 OCEAN BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ------------------------------------------------------ Application desc 2 cu 2 ahu ------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- HAAS, CHRISTOPHER & RONMEY CODY DONOVAN HEATING & AIR 66 PINE SONG PL 315 SIXTH AVENUE SOUTH THE WOODLANDS TX 77381 JACKSONVILLE BEACH FL 32250 (904) 241-3785 -------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . . 135 . 00 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/07/14 ---------------------------- Other Fees . . STATE MECH DCA SURCHARGE 2 . 03 STATE MECH DBPR SURCHARGE 2 . 03 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------- ---------- ---------- Permit Fee Total 135 . 00 135 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 06 4 . 06 . 00 . 00 Grand Total 139 . 06 139 . 06 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECH;AsNIC.AL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph 1904)247-5826 Fax(904) 247-5845 {ojaAnnREss: 75 Z5 03-6,v, 61 V 6 PERMIT# ,PROJECT VALUE ARI# 3slq D� --- REQUIRED Air Handling Equipment Only _X_Air Handling Unit & Condenser Condenser Only qEW AIS.CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning; Unit Quantity Toms Per Unit _ --- Seer Rating.� Heat: Unit Quantity BTU's Per Unit REQUIRED Duct Systems: Total CFM ZEPLACEMENT AIR CON'DITIONTNG & HEATING SYSTEM INSTALLATION Air Conditioning-, Unit Quantity 2 Tons Per Unit j3 Heat: Unit Quantity 2 BTU's Per Unit X12% Seer Rating — Duct Systems: Total CFM ,R, QT1lRED PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire StandpipeQuantity Requires 3 sets of plans) Underground Fire Main Value Requires 3 sets of plans) Fire Hose Cabinets Quantity -_ (Requires 3 setts of plans) Commercial .Hoods Quantity (Requires 3 seta of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) 4 E PLACES MISCELLANEOUS: Prefabricated Fireplace Qtvv Automobile Lifts Gas Piping Outlets Boilers _ BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets _ rumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: arrrtit becomes void if work does not comtttcnce within six month period ar work is suspmlided or abandoned for six months.i hereby certify that I have reAd u5 application and know the same to be it'uc and cotes:; All provisions of laws and orditttutM governing this work will be complied with whether specified or ot. The permit docs not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'raperry Owners Name Ho�as Phone Number 13L-3 r - 513-7 / n �- 11 £ r�,4- Office Phone 2 yl 3^7 Y Fax Jechanical Company 14.1�� rr S City lad l� h�, � _ State Zip3Z2 33 ;o. Address: �I� b h� �icensc Ilrolder(Pritiltt): State Certification/Registration# (�ACi0 3Q f iotarized Signature of.License Holder ►,• Before me this day of RICHARDTOMPKINS Commission#FF 040399 expires July 29,2017 Signature of Notary Public 7 �� Job: IPro ect Summary Date: March 10,2014 - wric�,htsoft' Entire House ay: Aaron Thacker Donovan Heat&Air 315 6th AW 5, kkcl(conswllle Beach, F02250 Phono:904.241-3785 FnX904.241-3745 Email;aaronedon"nac,corn Web:WWY Don"nAC,com For: Chris Haas, Downstairs 525 Ocean Blvd,Atlantic Beach, FL 322-.33 Notes: Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions ° 95 OF Outside db �U aF Outside db 20 aF Inside db Inside db Design b Design TD L g 31 F Dally rangge 50 Relative humidlty 53 gr/lb Moisture difference 9 Heating Summary Sensible Cooling Equipment Load Sizing 11282 Btuh Structure 15262 Btuh Structure 3353 Btuh Ducts 4753 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Humldification 0 Btuh Piping 14636 Btuh Use manufacturers data n Equipment load Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20015 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2263 Btuh Fireplaces 0 Structure 1014 Stuh Ducts 0 Btuh Heatingg Cooling Central vent(0 cfm) 3267 Btuh 13N 1324 Equipment latent load Area (ftp 11916 11916 23282 Btuh 4 volume (ft3) 0 5 p 23 Equipment total load Air changesthour 45 Req. total al capacity at 0.70 SHR 2.4 ton Equiv. A F (cfm) Heating Equipment Summary Cooling Equipment Summary MMake tem star Make Tempstar Trade 13 SEER N SERIES R41 OA HP Trade 13 SEER N SERIES R41 DA HP Model N4H330A(G)KB- Cond N4H330A(G)KB- AHRI ref no3819008 Coil 3AHRI ref no3819008 "' " 19008 11.0 EER, 13 SEER Efficiency 8 H5PF Efficiency 21000 Btuh Heating input Sensible cooling 9000 Stuh Heating output 30027 BFuh oQ 47°F Total cooling Latent cooling 30000 Btuh Temperature rise l air 1000 cfm Actual air flow 1000 cfm Actual flow 0,050 cfm/Btuh Air flow factor 0.068 ctm/Btuh Air flow factor 0 in H2O 0 in H2O Static pressure Static pressure 0.86 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Mer-10 13:54:0.9 W right:rsofit` pion't Right-8ulto�Unl�rgaf 8,tl.z4 83000995 A ls, G:1Uaetwl0wnpflnooumcntslWtlplt[BoR I-NACIBoguo 2.5 ton.rup cal,=w3 r-rout Door face*+, F