Loading...
469 Atlantic Blvd # 7 2014 fire alarm CITY OF ATLANTIC BEACH Si 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 14-00000316 Date 3/12/14 Property Address . . . . . . 469 ATLANTIC BLVD Tenant nbr, name . . . . . . UNIT 7 Application type description MECHANICAL FIRE PERMIT Property Zoning . . . . . . . COM GENERAL DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------- Application desc fire alarm system ---------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- DIAMOND REAL ESTATE PROPERTIES AUGUSTINE ALARM FIRE AND SOUND 6517 LOU DRIVE SOUTH P O BOX 1104 JACKSONVILLE FL 32216 ST.AUGUSTINE FL 32085 (904) 825-0030 ---------------------------------------------------------------- Permit . . . . . . FIRE SUPPRESSION SYSTEM Additional desc . . Permit Fee 95 . 00 Plan Check Fee . 00 Issue Date . . . . 3/10/14 Valuation . . . . 0 Expiration Date . . 3/10/14 ----- ------- ----- --- -------- ------------------------------ Special-Notes-and-Comments 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE *CONTRACTOR SHALL REQUEST FINAL INSPECTION THROUGH THE BUILDING DEPARTMENT AND THE DEPARTMENT WILL NOTIFY THE DUVAL COUNTY FIRE DEPARTMENT* 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE ----------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ----------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- -------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach APPLICATION NUMBER Js Building Department (To be assigned by t e Build' g partment.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 Fax(904)247-5845 jj �• E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM I $ 7 Property Address: �(D / �QI9�L, �EJ�✓GY 4ti�oneview t rre uired Ye No Applicant: /7f_ ehomm -c"S"a nning &Zing S Tree Administrator Public Works Project: Public Utilities Pu Fire Services v 2 z7 Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STA S� 1-e P '— SQ- Reviewing Department First Review: Approved. ❑Denied. - (Circle one.) Comments# Plea s�e for i-P, v A— - c � Svn BUILDING Pit),rg q 1 yrvNJ , hiz rPmprl< S' ©v\ 44\4 PLANNING &ZONING Reviewed by: An Date: TREE ADMIN. Second Review: [-]Approved as revised. ❑ enied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 It 4446, F-14-610627.000 11` CITY OF JACKSONVILLE, FLORIDA Permit Number BUILDING INSPECTION DIVISION I 1 I t FIRE PERMIT APPLICATION Date Issued � O Application must be typed or printed legibly in ink.Complete all relevant fields. PROJECT IDENTIFICATION PROPERTY OWNERSHIP DETAILS PROJECT NAM �p� l�+`�L,.� �cl��,rc�� _. TYPE Business °, PROJECT CONTACT Tyler Halbrooks FULL LEGAL NAME,AGENCY,OR BUSINESS PROJECT CONTACT PHONE(904)687-6359 Drop Back In Academy PERMIT ASSOCIATIONS? NO(2 YES if yes,list permit data below: MAILING ADDRESS ❑BUILDING PERMIT i61—I—I�I—I—I—LI—I—I—I—I—I OWNER CONTACT PHONE(904)381-0906 REAL ESTATE NUMBER _ . ...._...._.__ OWNER E-MAIL ADDRESS. ................ PERMIT ADDRESS(This is the physical address of the actual work location.) STREETNUMBER469 . STREET NAME ATLANTIC TYPE(AveeBl,da CourtlRoad;f Boulevard,,,,,......DIRECTION .. .._..._.....__....... UNIT/SUITE ............._._......_ ZIP CODE.3223.3............._ INTERSECTING STREETS _..... __.................. _........ AND _.�-- LOT NO.L..OTS BLOCK LOTS 81C SUBDIVISION SALTAIR__SEC_3_CITY DEVELOPMENT NUMBER_..._....... LICENSED CONTRACTOR i ENGINEER PROPOSED USE LICENSE NOT REQUIRED ❑ RESIDENTIAL NON-RESIDENTIAL 01,1PANY NAME ❑Apanmem School, Library, Other Educational NAME-( ALIFYING AGENT) ❑Carport EF20000487-JOHN HALBROOKS ❑Condominium STATE CERTIFICATION OR ❑Duplex REGISTRATION NUMBER !!=RZZ ❑Garage ❑Single Family Qi! FYIN CITY IDN ❑Townhouse ❑3 or 4 Family ADDRESS ST AUGUSTINE.FL 32085 ❑ b Other-Specify. ❑Parking Garage ❑Si Q Restaurant ❑Tetecommunrcatons PHONE 904-825-0030 FAX 904-797-3301 ie Service urinary,EducatRepair Gar tvarenouse ❑Servide Bladen,Repair Garage -E-MAlt ADDRESS tylerhalbrooks@yahoo.com a FIRE PLANS TYPE OF IMPROVEMENT NATURE OF WORK PE Select the type of fire plan Cheek one Check one. Rnuad^ �� Existing Building Fire Alarm system BRIEF DESCRIPTION OF WORK OR ADDITIONAL NOTES Installation of a Fire Alarm System JOB COST NATURE OF WORK DETAILS Check all that apply. WORKER'S COMPENSATION New Insurance $2498.00 ASSOCIATED INDUSTRIES EXPIRATION DATE 6/21/2014 HAZARDS FLAMMABLE LIQUID TANKS WATER-BASED SYSTEMS Select one classlfwation. Select all the categories that apply. Enter the number of units per gallon. Enter the total square footage. 0 Battery charging ❑Performance-Base Dewgn 1300.__...-__.__... Light hazard t3R. ...._..._...._._... Above Ground 0 units 10 gallon [3 Hot rmrk ❑Storage-High Pine peluge0 __, Dry Pipe O ❑HYPerbanc Chambers ❑Storage-Rack Belo,•Ground 0 units/0 gallon Pro-actron]U_, water rrwsl0 ............... ❑Pallet ❑Tire Storage warehouao Q ..__. units f 0. _.. .. gallon , wet pipe 0 . FIRE ALARM SYSTEMS WATER SUPPLIES NOWWATER-BASED SYSTEMS Select one ciassdicahon 'It Supervrsuq Total numUes n1 Heads aandStation.seled one Select one. Enter the total square footage _ Supervising station Central arces Public-City 0020 Rd 200 0 HabnO Wet-Dry chamQ..._.. .......__....._...._.._0.__. .__....__. Other-Specdy._._.._.n—...__.-____.._.____._ Fue Pump? Yes❑ No 0 .... Tota)area for permit 2700,0,00,, ___..square feet t Otter tin square feet)Q.._.......... COMMENTS(List equipment not shown etsevAtere: AUGUSTINE ALARM, INC. P.O. BOX 1104 ST. AUGUSTINE, FL 32085 PROPOSAL (904) 825-0030 To: DATE 2/13014 Soloman Olopade 3525 Ca mmwealth Avetnie SYSTEM LOCATION Jacks�e, FL 32254 Atlantic Beach In Reference to: High School Prep, /69 Atlantic Blvd., Atlantic Beach TELEPHONE 331-006 WE HEREBY SUBMIT SPECIFICATIONS AND ESTIMATES FOR: Fire A1= System 1 Fire Lite NS5UD Fire Alarm Control Panel 1 Fire Lite ArrX Amuaciator 2 Fire Lite H312 Pull Stations 3 Sistem Sensor P2P, Horn/Strobes 1 System Sensor T Strobe 3 System Sensor OA B Srloke Detectors 1 Ditek AC/Telco Surge Protector Kit 2 12 Volt 7 Amp Ho1r<' Backup Batteries All VEre, Labcr, Misc. i tterdals and Installation Incllxied Fire Marshal Permit Included Electrician to supply a dedicated locked breaker, caTluit racevays, JEnxes, straps, etc. at additional cost to customer Additional equignEnt at additional cost may be required by Authorities having Jurisdiction to meet local axles and/or job field conditions. WE PROPOSE to furnish this System complete with the above specifications for the sum of$ 2498-CO plus tax and payable as follows: + 174.36 tax $1[23,86"ONE HALF PLUS APPLICABLE SALES TAX DUE UPON ACCEPTANCE, BALANCE UPON COMPLETION" MONITORING SERVICES: The current rate for 24 hour monitoring with response is$ 37.00 plus tax and payable MONTHLY and in ADVANCE of each month with a 1.5%late fee added to all past due balances. Delinquent accounts of 45 days will be terminated without notice and collection procedures will commence. Material is guaranteed to be as specified.Work to be completed in a workmanlike manner according to standard practices.Any alteration or deviation from the above specifications involving extra costs will be done only upon written orders and will become an extra charge over and above the estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Owner to carry all other necessary insurance.Contractor will carry Worker's Compensation Insurance.Certificates of proof of insurance and licenses will be made available upon request.Due to promotional and product price changes,this proposal will be VOID AFTER 30 DAYS. X" A.T.R-EPW DAT F. ENTIRE AGREEMENT-CUSTOMER ACKNOWLEDGES THAT HE/SHE IS AWARE THAT NO ALARM SYSTEM CAN GUARANTEE PREVENTION OF LOSS,THAT HUMAN ERROR ON THE PART OF AUGUSTINEALARM OR THE MUNICIPAL AUTHORITIES IS ALWAYS POSSIBLE,AND THAT SIGNALS MAY NOT BE RECEIVED IF THE TRANSMISSION MODE IS CUT,INTERFERED WITH, OR OTHERWISE DAMAGED.THIS AGREEMENT CONSTITUTES THE ENTIRE AGREEMENT BETWEEN THE CUSTOMER AND AUGUSTINE ALARM.IN EXECUTING THIS AGREEMENT, CUSTOMERIS NOT RELYING ON ANY ADVICE OR ADVERTISEMENT OF AUGUSTINE ALARM.CUSTOMER AGREES THAT ANY REPRESENTATION,PROMISE,CONDITION,INDUCEMENT OR WARRANTY,EXPRESS OR IMPLIED,NOT INCLUDED IN WRITING IN THIS AGREEMENT SHALL NOT BE BINDING UPON ANY PARTY,AND THAT THE TERMS AND CONDITIONS HEREOF APPLY AS PRINTED WITHOUT ALTERATION OR QUALIFICATION,EXCEPT AS SPECIFICALLY MODIFIED AND APPROVED IN WRITING BY AN AUTHORIZED REPRESENTATIVE OF AUGUSTINE ALARM.THE TERMS AND CONDITIONS SHALL GOVERN NOTWITHSTANDING ANY INCONSISTENT OR ADDITIONAL TERMS AND CONDITIONS OR ANY PURCHASE ORDER OR OTHER DOCUMENT SUBMITTED BY THE CUSTOMER. r'INTOMFR e'T'ATFG TN AT RRFf1RF CIrNINr TRIC ArRFRMRNT UPN14R HAC ARAM ROT"CIt1Fe r1R THP ArRFRMRNT AN r)IINr1FRGTANr1C AT I TFRMC AM r)CON111TU)NC np RnTH AUGUSTINE ALARM, INC. P.O. BOX 1104 ST. AUGUSTINE, FL 32085 PROPOSAL (904) 825-0030 To: DATE 2/13/2014 Soia= 01cpade 3525 CamKnwealth Avenue SYSTEM LOCATION Jacksa me, FL 32254 Atlantic Pesch In Reference to: High School Prep, 469 Atlantic Blvd., Atlantic Pesch TELEPHONE 38"1-00 WE HEREBY SUBMIT SPECIFICATIONS AND ESTIMATES FOR: Fire Alarm System 1 Fire Lite NB5UD Fire Alarm Control Panel 1 Fire Lite Arm3 h=ciator 2 Fire Lite Bal2 Pull Stations 3 System Sensor HR lbrn/Stsnbes 1 System Sensor T Strobe 3 System Sensor 00 Spoke Detectors 1 Ditek AC/Telco Stege Protector Kit 2 12 Volt 7 Amp Bar Pacll�p Batteries All V re, Labcr, Misc. Ihterials and Installation Included Fire Mgirshal Permit Included aectrician to suFplty a dedicated locked klreaker, ea-lduit raceways, Jboxes, straps, etc. at additional cast to customer kbiticnal equignent at additional cost may be r 6T red by Authorities having J ictd-on to meet local codes and/or job field conditions. WE PROPOSE to furnish this System complete with the above specifications for the sum of$ 24016-00 plus tax and payable as follows: + 174.86 tax $1[23.86"ONE HALF PLUS APPLICABLE SALES TAX DUE UPON ACCEPTANCE,BALANCE UPON COMPLETION" MONITORING SERVICES: The current rate for 24 hour monitoring with response is$ 37.00 plus tax and payable MONTHLY and in ADVANCE of each month with a 1.5% late fee added to all past due balances. Delinquent accounts of 45 days will be terminated without notice and collection procedures will commence. Material is guaranteed to be as specified.Work to be completed in a workmanlike manner according to standard practices.Any alteration or deviation from the above specifications involving extra costs will be done only upon written orders and will become an extra charge over and above the estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Owner to carry all other necessary insurance.Contractor will carry Worker's Compensation Insurance.Certificates of proof of insurance and licenses will be made available upon request.Due to promotional and product price changes,this proposal will be VOID AFTER 30 DAYS.-------7 ` j A REP I DATE. ENTIRE AGREEMENT-CUSTOMER ACKNOWLEDGES THAT HE/SHE IS AWARE THAT NO ALARM SYSTEM CAN GUARANTEE PREVENTION OF LOSS,THAT HUMAN ERROR ON THE PART OF AUGUSTINE ALARM OR THE MUNICIPAL AUTHORITIES IS ALWAYS POSSIBLE,AND THAT SIGNALS MAY NOT BE RECEIVED IF THE TRANSMISSION MODE IS CUT,INTERFERED WITH, OR OTHERWISE DAMAGED.THIS AGREEMENT CONSTITUTES THE ENTIRE AGREEMENT BETWEEN THE CUSTOMER AND AUGUSTINE ALARM.IN EXECUTING THIS AGREEMENT, CUSTOMER IS NOT RELYING ON ANY ADVICE OR ADVERTISEMENT OF AUGUSTINE ALARM.CUSTOMER AGREES THAT ANY REPRESENTATION,PROMISE,CONDITION,INDUCEMENT OR WARRANTY,EXPRESS OR IMPLIED,NOT INCLUDED IN WRITING IN THIS AGREEMENT SHALL NOT BE BINDING UPON ANY PARTY,AND THAT THE TERMS AND CONDITIONS HEREOF APPLY AS PRINTED WITHOUT ALTERATION OR QUALIFICATION,EXCEPT AS SPECIFICALLY MODIFIED AND APPROVED IN WRITING BY AN AUTHORIZED REPRESENTATIVE OF AUGUSTINE ALARM.THE TERMS AND CONDITIONS SHALL GOVERN NOTWITHSTANDING ANY INCONSISTENT OR ADDITIONAL TERMS AND CONDITIONS OR ANY PURCHASE ORDER OR OTHER DOCUMENT SUBMITTED BY THE CUSTOMER. r'I ICTr1MFit CTATPC TWA,r nCFnVC CT(:NTpir TNTC A('RRRA MT NF/CT.P t-TAe RF!11 RnTU gfnPQ nP TUP ArVPFAAFNT ANTI TINr1F1TCTATQnq AT t TrRAAC ANTI!-.()Nn TTIr1Nc OP RnTN ECHANICAL PERMIT APPLICATION � m CITY OF ATLANTIC BEACH FILECOPY 800 Seminole Rd Atlantic Beach, FL 32233 MAR U 6 2014 ,Y Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: �- �- �V a / IT PROJECT VALUE $ avgSs,O d ARI#_ REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems _ Tanks (gallons) Wells OTHER: r�SS ,s•�- Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct.•All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners NamPhone Number Mechanical Companw\N�;t- V Nc, c_-Office Phone US-M30Fax--k(k-1 01 Co. Address- License CityS'���\vs���.�State --Zip License Holder(Print): —� State Certification/Registration# 5ct a,OCAp Notarized Signature of License Holder _ ''ii r PAMELA ANN LA me this ' d of" 20 �`t F(4O7) N '= MY COMMISSION#EE13 a ureofNota Pubic EXPIRES October 04,�� �'�98-0153 Fbridallot+rYServicexom DF-52416:C•A3-20 MS-SUDWSA OUD(E) Series FirelffegALarms Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel by Honeywell General The MS-51JID-3 is a five-zone FACP(Fire Alarm Control Panel) and the MS-101JID-7(E)is a ten-zone FACP.These control pan- � FILE copy els provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two-and four-wire smoke detectors, pull stations,waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm,Trouble, and Supervisory)and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone —Strobe Synchronization for System Sensor, Wheelock, line integrity. Gentex, Faraday, or Amseco devices. Activation of a compatible smoke detector or any normally- —Selective Silence(horn-strobe mute). open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the —Temporal or Steady Signal. piezo sounder at the FACP, activate the communicator and —Silenceable or Nonsilenceable. FACP alarm relay, and operate an optional module used to . Optional CAC-5X Style Z (Class A) Converter Module for notify a remote station or initiate an auxiliary control function. NACs and IDCs(2 required for MS-10UD-7). New options include a UL listed printer, PRN-6F and FireLite's • Form-C Relays for Alarm, Trouble and Supervisory - Con- ACT Internet Monitoring module. The FireWatch Series inter- tact Ratings 2.0 ACS 30 VDC or 30 VAC(resistive). net monitoring modules IPDACT-2 and IPDACT-2UD permit . 3.0 A total system current for MS-5UD-3. monitoring of alarm signals over the Internet saving the . 7.0 A total system current for MS-1 OUD-7. monthly cost of two telephone lines.Although not required,the secondary telephone line may be retained providing backup Optional Dress Panel DP 51050 communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush mounting. NOTE: The MS-10UD-7E offers the same features as the MS- • 24 volt operation. 1OUD-7 but allows connection to 240 VAC. Unless otherwise . Low AC voltage sense. specified, the information in this data sheet applies to both the 120 . Alarm Verification. VAC and the 240 VAC versions of these panels. PAS (Positive Alarm Sequence). NOTE:For ULC-listed models,see df-60440. • Automatic battery trickle charger. Features • Up to eight ANN-BUS annunciators: • Listed to UL Standard 864,9th edition. —Optional 8 zone Relay Module ANN-RLY. • Built-in DACT(Digital Alarm Communicator/Transmitter). —Optional LED Annunciator Module ANN-LED, • Style B(Class B) IDC(Initiating Device Circuit) —Optional Remote Annunciator ANN-80. —MS-5UD-3-five IDCs. —Optional Remote Printer Gateway ANN-S/PG. —MS-1 OUD-7-ten IDCs. —Optional LED Annunciator Driver ANN-1/0. • Style Y(Class B) NAC(Notification Appliance Circuit)-spe- ° Optional 4XTMF module (conventional reverse polarity/city cial application power box transmitter). —MS-5UD-3-four NACs. PROGRAMMING AND SOFTWARE: —MS-10UD-7-four NACs. • Can be programmed at the panel with no special software • Notification Appliances may be programmed as or additional equipment. —Silence Inhibit. • Programmable Make/Break Ratio. —Auto-Silence. • Upload/Download(local or remote)of program and data via integral DACT. DF-52416:C•05/12/2009—Page 1 of 4 USER INTERFACE: • SYSTEM RESET(lamp test) • Built-in DACT(Digital Alarm Communicator/Transmitter). • DRILL • Integral 80-character LCD display with backlighting and keypad. Terminal Blocks • Real-time clock/calendar with automatic daylight savings AC Power—TB1: adjustments. MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, • ANN-BUS for connection to remote annunciators. 1.00 A. • Audible or silent walk test capabilities. • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, • Piezo sounder for alarm,trouble, and supervisory. 3.80 A. • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, Controls and Indicators 2.20 A. LED INDICATORS Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. • FIRE ALARM (red) Supervised, nonpower-limited. • SUPERVISORY(yellow) Battery(sealed lead acid only)—J12: • TROUBLE(yellow) • Maximum Charging Circuit-Normal Flat Charge:27.6 VDC Q 1.4 A. Supervised, nonpower-limited. • AC POWER (green) • Maximum Charger Capacity: 18 AH battery for MS-5UD-3, • ALARM SILENCED(yellow) and 26 AH battery for MS-10UD-7(E). [Two 18 Ah batteries CONTROL BUTTONS can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] • ACKNOWLEDGE • Minimum Battery Size:7 AH. • ALARM SILENCE Top = _ _ _ _ = Depth=5.207"(13.23 cm) 1 Door= 16.821"(42.73 cm) Depth= Backbox= 16.65"(42.29 cm) (13.3 533 c )I Door= 19.26"(48.92 cm) (D Backbox= 19.0"(48.26 cm) E _ 3 �t _J_ Left Side Right Side Bottom Cabinet Measurements Page 2 of 4—DF-52416:C•05/12/2009 Initiating Device Circuits —TB4 (and TB 6 on MS-10UD-7 phone output ports for internet communications over customer only): provided ethernet internet connection. Requires compatible • Alarm Zones 1 -5 on TB 4(MS-5UD-3 and MS-10UD-7). Teldat Visoralarm Central Station Receiver.Can use DHCP or static IP. (See data sheet df-52424 for more information.) • Alarm Zones 6- 10 on TB6(MS-10UD-7 only). • Supervised and power-limited circuitry. IPBRKT: Mounting kit for IPDACT in common enclosure. • Operation:All zones Style B(Class B). fPSPLT: Y Adaptor option to allow connection of both panel • Normal Operating Voltage: Nominal 20 VDC. dialer outputs to one cable input to IPDACT(sold separately). • Alarm Current: 15 mA minimum. OPTIONAL MODULES • Short Circuit Current:40 mA max. CAC-5X:Optional(Class A)Converter Module.Converts Style • Maximum Loop Resistance: 100 ohms. B (Class B) Initiating Device Circuits to Style D (Class A); and • End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- listed). 7(E)main circuit board and to J7 on the MS-10UD-7(E). • Standby Current:2 mA. NOTE: Two Class A Converter Modules are required for the ten- Refer to the Fire-Lite Device Compatibility Document for listed zone panel. compatible devices. 4XTMF: Transmitter module. Provides a supervised output for Notification Appliance Circuits — TB5 (and TB 7 on MS- local energy municipal box transmitter and alarm and trouble 10UD-7 only): reverse polarity. Includes a disable switch and disable trouble • Four NACs LED.A module jumper option allows the reverse polarity circuit • Operation: Style Y (Class B) to open with a system trouble condition if no alarm conditions exists.Mounts to the main circuit board connectors J4 and J5. • Special Application power • Supervised and power-limited circuitry COMPATIBLE ANNUNCIATORS • Normal Operating Voltage: Nominal 24 VDC ANN-80: Remote LCD Annunciator. Mimics the information • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A displayed on the FACP's LCD. Red. (For white, order: ANN- maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- 80-W') mum per NAC. ANN-LED: LED Annunciator with three LEDs for each zone: • End-of-Line Resistor:4.7K ohm, 1/2 watt(Part#71252) Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) • Max.Wiring Voltage Drop:2 VDC dress panel. (For white,order: ANN-80-W.) Refer to the Fire-Lite Device Compatibility Document for com- ANN-BLED: LED Annunciator with three alarm (red) indica- patible listed devices. tors for up to 30 input zones or addressable points. (See DF- 60241). Form C Relays—T68: ANN-RLY: Relay module. Mounts inside the cabinet. Provides • Relay 1(factory default programmed as Alarm Relay) ten Form C relays. • Relay 2 (factory default programmed as fail-safe Trouble ANN-S/PG:Serial/parallel printer gateway. Provides a connec- Relay) tion for a serial or parallel printer. • Relay 3(factory default programmed as Supervisory Relay) ANN-1/0: Driver module. Provides connections to a user-sup- Special Application Resettable Power—TB9: plied graphic annunciator. • Jumper selectable by JP31 for resettable or nonresettable ACCESSORIES power. • Operating voltage:24 VDC nominal. DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch • Maximum available current: 500 mA - appropriate for pow- panel. ering four-wire smoke detectors. BB-26: Battery backbox, holds up to two 25 AH batteries and • Power-limited circuit. CHG-75. Refer to the Fire-Lite Device Compatibility Document for listed BB-55: Battery backbox,holds up to two 25 AH batteries. compatible devices. TR CE: Optional trim ring for semi-flush mounted cabinets. Remote Sync Output-T62: Remote power supply synchro- nization output,only required for the MS-5UD-3.24 VDC nom- PRN-6F: UL listed printer. inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame&post operating instruction sheet). MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame& post operating instruction sheet). MS-10UD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- DF-52416:C•05/12/2009—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Annunciators ......................................................................8 This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH Electrical Specifications (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, components may be adversely affected by extreme tempera- 1.0 A ture ranges and humidity. Therefore, it is recommended that • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, this system and its peripherals be installed in an environment 3.90 A with a normal room temperature of 15—27°C/60—80°F. • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Agency Listings and Approvals • Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- The listings and approvals below apply to the basic MS-5UD-3 tion,supervised,nonpower-limited and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval Cabinet Specifications agencies, or listing may be in process. Consult factory for lat- Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x est listing status. 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x • UL Listed: File S624 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring • FM Approved (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.)wide. . CSFM: 7165-0075:214 Shipping Specifications • MEA: MEA:333-07-E NOTE:For ULC-listed models,see df-60440. Dimensions: -20.00° (50.80 cm.)high NFPA Standards —22.5" (57.15 cm.)wide The MS-5UD/MS-10UD(E) Series complies with the following —8.5" (21.59 cm.)deep. NFPA 72 Fire Alarm Systems requirements: Weight:27 Ib(12.20 kg) —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). —AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). —REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTMF is required.) —PROPRIETARY(Automatic, Manual and Waterflow). —CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). —OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANIFACTIRINR All specifications are subject to change without notice. Made in the U.S.A. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52416:C•05/12/2009 df-52417:c•B-90 ANN-80 Flre•LITeg'ALarms 80-Character LCD Serial Annunciator by Honeywell Annunciators General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed,filtered power supply. ANN-80 is red;for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features • Listed to UL Standard 864,9th Edition. • Backlit 80-character LCD display(20 characters x 4 lines). • Supervisory • Mimics all display information from the host panel. • Alarm Silenced • Control switches for System Acknowledge, Signal Silence, Drill,and Reset. Specifications • Control switches can be independently enabled or disabled • Operating voltage range: 18 VDC to 28 VDC. at the FACP. • Current consumption @ 24 VDC nominal(filtered and non- • Keyswitch enables/disables control switches and mechani- resettable):40 mA maximum. cally locks annunciator enclosure • Ambient temperature:32°F to 120°F(0°C to 49°C). • Keyswitch can be enabled or disabled at the FACP. • Relative humidity: 93%t 2% RH (noncondensing) at 32°C • Enclosure supervised for tamper. t 2°C(90°F t 3°F). • System status LEDs for AC Power, Alarm, Trouble, Supervi- • 5.375' (13.65 cm.) high x 6.875' (17.46 cm.) wide x 1.375' sory,and Alarm Silence. (3.49 cm.)deep. • Local sounder can be enabled or disabled at the FACP. • For use indoors in a dry location. • ANN-80 connects to the ANN-BUS terminal on the FACP and • All connections are power-limited and supervised. requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- Agency Listings and Approvals ble,supervisory, zone,and custom alpha labels. The listings and approvals below apply to the ANN-80. In some • Time-and date display field. cases, certain modules may not be listed by certain approval • Surface mount directly to wall or to single, double, or 4" agencies, or listing may be in process. Consult factory for latest square electrical box. listing status. • Semi-flush mount to single, double, or 4" square electrical . UL: S2424 box. Use ANN-SB80KIT for angled view mounting. • FM approved • Can be remotely located up to 6,000 feet(1,800 m)from the CSFM:7120-0075:211 panel. • Backlight turns off during AC loss to conserve battery power • MEA:442-06-E but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote The ANN-BUS power supply(requires 24 VDC). POWERING THE DEVICES ON THE ANN-BUS FROM • Up to eight ANN-80s can be connected on the ANN-BUS. AUXILIARY POWER SUPPLY Controls and Indicators The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the • AC Power ANN-BUS power requirements. See the FACP manual for more • Alarm information. • Trouble df-52417:c•05/22/09—Page 1 of 2 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw, the following Each ANN-BUS device requires a unique address(ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP.A maximum of 8 devices located from the FACP on a single wire run. The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum. In general,the wire length is lim- See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk ('). Maxi- The ANN-80 connects to the FACP ANN-BUS communications mum length can never be more than 6,000 feet (1,800 m), circuit. To determine the type of wire and the maximum wiring regardless of gauge used. See table below. distance that can be used with FACP ANN-BUS accessory mod- WIRE REQUIREMENTS:POWER CIRCUIT ules. it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75-2.08 mm2) wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. Power wire distance limitation is set by 1.2 case currents for each module. volt maximum line drop form source to end of circuit. NOTE: For total worst case current draw on a single ANN-BUS • All connections are power-limited and supervised. refer to appropriate FACP manual. • A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. '6,000 ft. '6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80:Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SB80KIT-R: Red surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB80KIT W: White surface mount backbox with angled ® e A - wedge. Tel iT 4 3 2 1 ANN-BUS Device A 0 MS-905OUD T133 1 2 3 4 5 6 7 9 FACP Wiring to ANN-BUS Device FireLite®Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINEERINi 8 MRNUERCTURINU All specifications are subject to change without notice. Made in the U.S.A. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-52417:c•05/22/09 June 10,2005 DF-52004• F-050 • FIMIIM ALarms BG-12 Series by Honeywell Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices GENERALCalifornia The Fire-Lite Alarms BG-12 Series is a cost-effective,fea- State Fire Marshal ture-packed, non-coded series of manual fire alarm pull C US 7150-0075:184 stations. It was designed to meet multiple applications with the installer and end-user in mind.The BG-12 Series LISTED features a variety of models including single- and dual- S711 action versions. FM MEA The BG-12 Series provides Fire-Lite Fire Alarm Control 67-02-E Panels (FACPs),as well as other manufacturers'controls, APPROVED with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES • Aesthetically pleasing, highly visible design/color. • Attractive contoured shape with light textured finish. • Meets ADA 5 Ib. maximum pull-force. • Meets UL 38, Standard for Manually Actuated Signaling PUSH IN Boxes. PULL DOWN • Easily operated (single-or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. • The word"ACTIVATED"appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. • Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. • Braille text included in finger-hold area of operation handle and across top of handle. • Multiple hex- and key-lock models available. • U.S. patent-pending hex-lock needs only aquarter-turn Switch contacts are normally open. to lock/unlock. • Can be surface (with SB-1/0 or SB-10) or semi-flush mounted. Semi-flush mount to a standard single-gang, • Station can be opened for inspection and maintenance double-gang, or 4" (10.16 cm) square electrical box. without initiating an alarm. ack • Product ID label viewable by simply opening the cover; (1.27 cm). backbox overlap asingle-gang label is made of a durable long-life material. cutout is large enough utout by up to 1/2" (1 • The words"NORMAL"and"ACTIVATED"are molded into • Optional trim ring ). the plastic adjacent to the alarm switch (located inside). • Spanish version (FUEGOUEGO) available (BG-12LSP). • Four-position terminal strip molded into backplate. • Designed to replace the Fire-Lite legacy BG-10 Series. • Terminal strip includes Phillips combination-head cap- • Models packaged in attractive, clear plastic (PVC), tive 8/32 screws for easy connection to Initiating Device clamshell-style, point-of-purchase packages. Packag- Circuit (IDC). ing includes a cutaway dust/paint cover in shape of pull • Terminal screws backed-out at factory and shipped ready station. to accept field wiring (up to 12 AWG/3.1 mm2). Fire-Lite® Alarms, System Sensor®, and SpectrAlert® are • Terminal numbers are molded into the backplate, elimi- registered trademarks of Honeywell International Inc.LEXANO is natin the need for labels. a registered trademark of GE Plastics, a subsidiary of General 9 Electric Company. This document is not intended to be used for installation purposes. We try to keep our product 1S0 �oo� information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. WTI=4- For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING A MANUFAMAING Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52004•06/10/05 — Page 1 of 2 CONSTRUCTION PRODUCT LINE INFORMATION • Cover, backplate and operation handle are all molded BG-12S Single-action pull station with pigtail connec- of durable polycarbonate material. tions, hex lock. • Cover features white lettering and trim. BG-12SL Same as BG-12S with key lock. • Red color matches System Sensor's popular SpectrAlertO BG-12 Dual-action pull station with SPST N/O horn/strobe series. switch,screw terminal connections,hex lock. OPERATION BG-12L Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger- BG-12LSP Same as BG-12L with English/Spanish hold area that includes Braille text. In addition to PUSH IN (FIRE/FUEGO) labeling. and PULL DOWN text,there are arrows indicating how to BG-12LOB Same as BG-12L with "outdoor use" listing. operate the station, provided for non-English-speaking Includes outdoor listed backbox, and seal- persons. ing gasket. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down BG-12L0 Same BG-12L with "outdoor use" listing. position, the word "ACTIVATED" appears at the top in Does nootf include backbox. bright yellow, with a portion of the handle protruding at BG-12LA Same as BG-12L with auxiliary contacts. the bottom as a visible flag.Resetting the station is simple: BG-112LPS Same as BG-12L with presignal feature. insert the key or hex (model dependent), twist one quar- ter-turn, then open the station's front cover, causing the BG-12LPSP Same as BG-12LPS with English/Spanish spring-loaded operation handle to return to its original (FIRE/FUEGO) labeling. position.The alarm switch can then be reset to its normal SB-UO Indoor/outdoor backbox. (non-alarm) position manually (by hand) or by closing the station's front cover,which automatically resets the switch. SB-10 Indoor use backbox. SPECIFICATIONS 17003 Key lock. 17007 Hex lock. Physical Specifications: pull station SB-UO SB-10 Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) 1 (3.66 cm) (3.49 cm) 52004a m.Im Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. (33.531.531 ) ENGINEERS' & ARCHITECTS' SPECIFICATIONS wire Length Manual Fire Alarm Stations shall be non-code,with a key Strip Gauge or hex-operated reset lock in order that they may be tested, T and so designed that after actual Emergency Operation, TI they cannot be restored to normal except by use of a key or 1.000" hex. An operated station shall automatically condition it- (2.540) self so as to be visually detected as activated. Manual sta- tions shall be constructed of red colored LEXANO(or poly- carbonate equivalent)with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters,1.00 inches(25.4 0.750" mm) or larger.` Stations shall be suitable for surface (1.905) mounting on matching backboxes SB-10 or SB-I/O; or 5.500" semi-flush mounting on a standard single-gang, double- (13.970) gang, or 4" (10.16 cm) square electrical box. and shall be installed within the limits defined by the Americans with (cm) Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. E 'NOTE:The words'FIRE/FUEGO"on the BG-12LSP shall appear on the front of the station in white letters,approximately 314"high. Page 2 of 2 — DF-52004•06/10/05 SYSTEM .SENSOR' r Selectable Output I" Horns, Strobes, and 4 Horn/Strobes SpectrAlert'Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECT� ert The SpectrAlert Advance series of notification appliances is Features designed to simplify installations,with features such as plug in .Electrically compatible with existing SpectrAlert products designs,instant feedback messages to ensure correct installation of ,Automatic selection of 12-or 24-volt operation at 15 and 15/75 individual devices,and 11 field-selectable candela settings for wall candela and ceiling strobes and horn/strobes. •Plug-in design When installing Advance products,first attach a universal mounting Field selectable candela settings on wall and ceiling units:15,15/75, plate to a four-inch square,four-inch octagon or double-gang 30,75,95,110,115,135,150,177,185 junction box.The two-wire mounting plate attaches to a single-gang .Same mounting plate for wall-and ceiling-mount units junction box. •Shorting spring on mounting plate for continuity check before Next,connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction •Outdoor wall and ceiling products rated from-40°F to 151°F Finally,attach the horn,strobe or horn/strobe to the mounting plate .Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The ,Horn rated at 88+dbA at 16 volts device will rotate into position,locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification .Outdoor products rainproof per UL 50(NEMA 3R) appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for Compatible with MDL sync module wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings SIGNALING .�� 7125-1653186(indoor s"Ws) u F M MEA h CO. 53:18 (outdoor br, 7125-,1 3 653:,888(hom/sno6es. approved (hi , b ) LISTED APPROVED 7,35-1653:189(horns,chh.ores) S40; _ MEA 952-05 t 55512 53593 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1'h-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1 7/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,1 S0,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,Flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at I Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon Flash tube and associated lens/reflector systern.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 411/,6 x 411/4 x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Ellectricall Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature -40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8-diameter x 2.5-high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x S.0'W x 2.2'D(151 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.25"high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1'W x 2.0'D(145 mm L x 130 rnm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1"diameter x 2.0-high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-003 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15' 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75' 142 148 77 81 Temporal Medium 44 49 58 69 30" NA NA 94 96 Temporal Low 38 44 44 48 75" NA NA 158 153 Non-temporal High 57 56 69 75 95' NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw 8-17.5 Volts 16-33 Volts DC input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(rnA RMS),2-wire Horn/Strobe,High Candela Range(135-185 cd) - 16-33 Volts 16-33 Volts --- DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-ternporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporai Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candelaHorn Horn/Strobe Output ratings must be reduced in accordance with this table. 8-17,5 16-33 24 Volt Nominal Strobe Output Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 V Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 150 150 91 Coded Low 75 75 81 81 88 85 96 92 177 177 rSettings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 A05-0395-003 SpectrAlert Advance Dimensions 4.7" 2.5 68" Dia. 2.5" 5.6• Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1" 7.1" 2.25+1 2.0" Dia. -5.05 2.23 Dia. O o o o 0 2� P&O.C 5.98• ® 5.7" O o 0 0 0 0 0 O O O O Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes(contd.) P2R*' 2-wire Horn/Strobe,Standard cd=,Red PC2W*' 2-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH*' 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH* 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P41RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P4W* 4-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P4WH* 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR*' Strobe,Standard cd,Red SCW*' Strobe,Standard cd,White SRH*' Strobe,High cd,Red SCWH*' Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW* Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. All outdoor units ending in"K"include a weatherproof back box. SYSTEM oZCh Sys em OLa o 3825 Ohio Avenue•St.Charles,IL 60174 R ��^'wN�s�a^—° Wng^thel"°"`°` of "'u""'"'" SENSOR kx �R��a ����,.�X1� .=�,a �, Phone:800-SENSOR2•Fax:630-377-6495 A05-0395-003-12/06-#1676 .SYSTEM SENSOR Photoelectric Smoke Detectors System Sensor's i3,.,series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire the bases included with the heads.The large wire entry port and in-line terminals Large wire entry port provide ample room for neatly routing the wiring inside the base. In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, Mounts to octagonal and single-gang backboxes,4-square as well as direct mounting with drywall anchors.To complete the backboxes,or direct to ceiling installation,P heads plug in to the base with a simple Stop-Drop'N Lock"action. Stop-Drop'N Lock attachment to base Removable detector cover and chamber Intelligence.i3 detectors offer a number of intelligent features Built-in remote maintenance signaling to simplify testing and maintenance.Drift compensation and smoothing algorithms are standard with the P line to minimize Drift compensation and smoothing algorithms nuisance alarms.Two-wire P detectors needing cleaning can Simplified sensitivity measurement generate a remote maintenance signal,when connected to the Wide angle,dual color LED indication 2W-MOD2 loop test/maintenance module,or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the Loop testing via EZ Walk feature module and the panel.The SENS-RDR,a wireless device,displays the Built-in test switch sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol,the EZ Walk loop test feature is available on two-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & < FM > 0 MEA M" LISTED APPROVED approved approved 5911 3011446 7272-1209.210 290-01-E 2093 (t)Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signalims.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel,and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12V,23mA @ 24V Peak Standby Current 2-wire:100 NA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz.(178 grams) Operating Temperature Range 2W-B and 4W-B:32°F-120°F(0°C-49°C);2WT-B and 4WT-B:32°F-100°F(0°C-37.8°C Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(S°C) Sensitivity 2.5%/ft.nominal Input Terminals 14-22 AWG Mounting 31k-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power uo Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every S seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 'Model Thermal Wiring Alarm Current 2W-B No 2-wire130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12V,23mA @ 24V 4WT-B Yes 4-wire 20 mA @ IN 23mA @ 24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 in.(16.76cm)diameter SYSTEMo 02006 Sy-m.e—,3825 Ohio Avenue•St Charles,IL 60174 7nAuasp fi ztprssuoerttodmgevmnoutnouce.Vtnsynemsensrnc r near p,.d.mf.r t—.-WN the ixten version a f&.Bata sheet. SENSOR, Phone:800-SENSOR2•Fax:630-377.6495 AOS-0318-006.7/06•#1676 Well ALarr*4 L I V UP IS' .'WD-3 Battery Calculation by Honeywell Secondary Power Source Requirements 1. System 1 x 0.110000 = 0.110000 1 x 0.214000 = 0.214000 Main Circuit Board _ 4XTMF 0 x 0.005000 - 0 x 0.011000 - CAC-5X 0 x 0.001000 = 0 x 0.001000 = IPDACT-2 0 x 0.093000 = 0 x 0.136000 = IPDACT-2UD 0 x 0.098000 = 0 x 0.155000 = 2.Annunciators _ ANN-80 1 x 0.015000 = 0.015000 1 x 0.040000 - 0.040000 ANN-RLY 0 x 0.015000 - 0 x 0.075000 = ANN-1/0 0 x 0.035000 = 0 x 0.200000 = ANN-1/0 LEDs 0 x 0.000000 = 0 x 0.010000 = ANN-S/PG 0 x 0.045000 = C x 0.045000 = ANN-(R)LED 0 x 0.028000 = 0 x 0.068000 = 3.Conventional Detection ......... Two-Wire Detector Heads 3 x 0.000000 = 0.000000 :::::.... . 0 x 0.000000 - >:::: Four-Wire Detector Heads - Number of IDC's Used Minus 1 0 x 0.040000 = 4.Other Devices _ EOLR-1 0 x 0.020000 = 0 x 0.020000 - Miscellaneous Device 1 0 x 0.000000 = 0 x 0.000000 = Miscellaneous Device 2 0 x 0.000000 = 0 x 0.000000 = Miscellaneous Device 3 0 x 0.000000 = 0 x 0.000000 Miscellaneous Device 4 0 x 0.000000 = 0 x 0.000000 - Miscellaneous Device 5 0 x 0.000000 = 0 x 0.000000 = 5. Notification Appliances = 3 x 0.567000 1.701000 NAC 1 - 1 x 0.066000 - 0.066000 NAC 2 - 0 x 0.000000 - NAC 3 - 0 x 0.000000 - NAC 4 - Current Draw from TB9(nonalam) 0 x 0.000000 = 0 x 0.000000 - Total StandbyLoad 0.125000 Total Alarm Load 2.021000 Fire-Lite Alarms Page 1 2/19/2014 I }Fire-uTeALarmS MS-5UD-3 Battery Calculation by Honeywell Calculation in Total Sheet 24 Hours Standby Load Current 0.12500 Amps x 24 7-3-0_00AH 15 Minutes Alarm Load Current(Amps) 2.02100 Amps x 0.25 = 0.505 AH Total Current Load 3.505 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 4.21 AH Recommended Batteries: BAT-1270 -7AH Batteries Battery Check The batteries can be char ed by the MS-50D-3 Charger. The batteries can be housed in the MS-5UD-3 Cabinet. NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS-5UD-3 Control Panel: The output current is within the panel's limitations. Fire-Lite Alarms Page 2 2/19/2014