Loading...
421 Sargo Rd 2014 new service CITY OF ATLANTIC BEACH 1 ) 800 SEMINOLE ROAD J ATLANTIC BEACH,FL 32233 h INSPECTION PHONE LINE 247-5814 �JF3 Application Number . . . . . 14-00000222 Date 3/14/14 Property Address . . . . . . 421 SARGO RD Application type description SINGLE FAMILY RESIDENCE Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 151391 ------ -- ------------------------------------------------------------------- Application desc NEW HOME ---------------------------------- Owner Contractor -------------- ---------- AF AB VENTURE LLCET AL MATHIEU BUILDERS 1778 OCEAN GROVE DR 800 C 3RD ST NEPTUNE BEACH FL 32266 JACKSONVILLE FL 32226 (904) 813-3661 --- Structure Information 000 000 NEW HOME Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . RESIDENTIAL -----Flood-ZoneZONE --------------- ------------------- ----------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Sub Contractor FERRANTI ' S ELECTRIC Plan Check Fee 00 Permit Fee . . . . 125 . 00 0 Issue Date Valuation Expiration Date . . 9/10/14 -------------------------------- - ----------------------------------------- Special Notes and Comments Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed at the property line . Cleanout must be covered with an RTl concrete box with metal lid. Cleanout to be set to grade and visible. If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All concrete driveway aprons must be 5" thick, 4000 psi, with fibermesh from the edge of pavement to the property line . Reinforcing rods or mesh area not allowed in the right-of-way. Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed Don1City Right-of-Way. tp PERMIT IS ( Liv �' I BED i+r E�I/IY�Ej"�t'i� TICS � AI CE`S� D PCVRIDA BUILDING CODES. CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 r INSPECTION PHONE LINE 247-5814 Jit �? Page 2 Application Number . . . . . 14-00000222 Date 3/14/14 -------------------------------------------------------------------------- Special Notes and Comments Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible . *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS -------------------------------------------------------------- Other Fees . . . . . . . . . STATE ELEC DCA SURCHARGE 2 . 00 STATE ELEC DBPR SURCHARGE 2 . 00 ---------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- --- Permit Fee Total 125 . 00 125 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 129 . 00 129 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd,Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: 4.0 SAR6-0 RQ4P PERMIT# JEA INFORMATION REQUIRED ON ALL PERMITS :=),,-- AMPS AMPS VOLTS PHASE LC9U VALUE OF WORK NEW SERVICE ❑ Overhead ❑ Underground �nderground up Pole ❑Residential(Main)Servicel ❑0-100 amps ❑101-150amps 51-200amps ❑ amps #of Meters El Commercial(Main)Service ❑0-100 amps ❑101-150amps ❑151-200amps ❑ amps OCT Service amps Conductor Type QL.4,v.-j " Size '1/0 ❑Multi-Family(Main)Service El 0-100 amps El 101-150amps ❑151-200amps []_amps #of Unit Meters ❑Temporary Pole ❑ amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) ❑100 amps ❑150amps ❑200amps ❑ amps OCT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 94 0-30amps 31-100amps 101-200amps Appliances: j 0-30amps 1 31-100amps 101-200amps A/C Circuits: / 0-60amps 61-100amps Heat Circuits: / # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS ❑Swimming Pool ❑ Sign ❑Smoke Detectors_Qty ❑Transformers KVA ❑Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK$ Qty volts/amps REPAIRS/MISCELLANEOUS ❑Replace Burnt/Damaged Meter Can El Safety Inspection ❑Panel Change ❑OH to UG ❑Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Electrical Company Fe r/-at4 � ���f� C L�—�— Office Phone X1-JX.kb Fax V2-5- )y�2 Co.Address: 1491 -A—V� LAA City kC Slt State (L Zip -o-a Y2 License Holder(Print): f� Q• l ati State Certification/Registration#�'C�t F,0-6 Notarized Signature of License Holder Befo me:this day of 20 Signature of Notary Public