Loading...
631 Selva Lakes Cir 2014 HVAC ai yL'1:rJf� CITY OF ATLANTIC BEACH 11 1 f 800 SEMINOLE ROAD .a r� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 cw13 Application Number . . . . . 14-00000424 Date 3/20/14 Property Address . . . . . . 631 SELVA LAKES CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------- Application desc 1 cu 1 ahu --------------------------------------- Owner Contractor ------------------------ WHITE, NATALIE L DONOVAN HEATING & AIR 631 SELVA LAKES CIRCLE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322334378 (904)CKSONVIL E BEACH FL 32250 -------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . 00 Permit Fee . . . . 95 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 9/16/14 ----------------------- - -------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . --------------------- --------------------- ---------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due g ---------- ---------- ----------------- ---------- - Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: ES R PERMIT# PROJECT VALUE $ 4359 w ARI REQUIRED Air Handling Equipment Only 4Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Rating Heat: Unit Quantity BTU's Per Unit gREQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity t Tons Per Unit /5 3 Seer Rating Heat: Unit Quantity / BTU's Per Unit Duct Systems: Total CFM REQUIRED FIRE PREVENTION Re uires 3 sets of plans) Fire Sprinkler System Quantity ( q (Requires 3 sets of plans) Value ( Fire Standpipe Quantity Reuires 3 sets of plans) Underground Fire Main q Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: work is suspended or abandoned for six months.I hereby certify that Permit becomes void if work does not commence within a six month period or I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 1v&-FAi —Phone Number 1;?Q(9 -0g60 Mechanical Company IJ�iNOt/1�►�► 1-tFP� s AIR Office Phone �qi 3785 Fax .241 37q ``� Z O Co. Address: 3�� (9 PSE � City �� �� State p Zip 3Z l/�/�in n.. State Certification/Registration# License Holder(Print): Notarized Signature of License Holder ;:�:::� RICHARDTOMPKINS Before me this day of 20 R. Commission#FF 040399 /�G/ �/ :. .. f� lw, l Expires July 29,20» Si nature of Notary Public • Rf�Q:� Bwww TMu Troy Fain I BOP3WMig b Job: wri htsoft Project Summary Date: March 19,2014 9 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Proiect Infonnation For: Natalie White 631 Selva Lakes Cir, Atlantic Beach, FL 32233 Notes: IL Design • • Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 20 °F Daily range L Relative humidity 50 Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Btuh Structure 15262 Btuh Ducts 3308 Btuh Ducts 4672 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14590 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19934 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Structure 2253 Btuh Fireplaces Ducts 997 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft2) 1324 1324 Equipment latent load 3250 Btuh Volume (ft") 11916 11916 Air changes/hour 0.45 0.23 Equipment total load 23184 Btuh Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 15 SEER N SERIES R41 OA HP Trade 15 SEER N SERIES R41 OA HP Model NXH530GKA* Cond NXH530GKA* AHRI ref no3670844 Coil FXM4X30**A* AHRI ref no3670844 Efficiency 8.7 HSPF Efficiency 12.5 EER, 15.3 SEER Heating input Sensible cooling 20160 Btuh Heating output 28600 Btuh @ 47°F Latent cooling 8640 Btuh Temperature rise 27 °F Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.066 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Mar-20 08:10:17 _ } + wrightsoft Right-Suite®Universal 8.0 24 RSU05995 Page 1 ACC? C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton rup Calc=MJ8 Front Door faces: E