671 Amberjack LN 2014 hvac CITY OF ATLANTIC BEACH
f 800 SEMINOLE ROAD
s)
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000438 Date 3/31/14
Property Address . . . . . . 671 AMBERJACK LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
KING, ADAM J DONOVAN HEATING & AIR
671 AMBERJACK LANE 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 322334202 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 9/27/14
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FTS 32233
Ph(904) +2-47-5826 Fax (904) 247-5845
SOB ADDRESS: L jYY� —�{�Cly L,J PCRMIT#
PROJECT VALUES 3 G y ib AN# 3(o- D�j q REQUIRED
Air Handling Equipment Only YAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit __. _ Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity f Tons Per Unit • _. _
Heat: Unit Quantity �_ BTU's Per Unit 3d_oaa__ Seer Ratintg /5 .3
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 gets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 seta of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Pen-nit becomes void if work docs not commence within a six month period or work is suspended or abandoned for six months,I hereby certify that I have read
ris application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
at. The permit docs not give authority to violate the provisions of any other staic or local law regulation constriction or the performance of construction,
Property Owners Name 1 _�� t Phone Number
Mechanical Company p� � �r 01'fice Phone kyr 37�S Fax 2.1
Co. Address: 315 (oJ,6 Ay�
City, T�,;s Bc) State F► zip 3Z-Z, D
License Holder(Print): State Certification/Registration
Notarized Signature of License Holder -
1 RICHARD TOMPKINS Before me this day of ' 20
_�.X
4 Commission#FF 04039941/14� SX=�
a� Expires July 29,2017 Si rta<,.. e of Notary Public
f g
8vndod Thr,Troy FaM Innunnn�AooaaG-7010
Date:t S
Pro ecumma
-�^ Wlrigh►tSiD�t, � ■ Date: March 20,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Aon S.JFckaonvllle 9each, FL 32250 Phone:904-241.3785 Fax:904-241-3745 email;a„1ronodonovanac.com wcb:www.DonowanAC.com
PrQject Informati•n.
por: Adam Kinc1
671 AmbeUack Ln, Atlantic Beach, FL 32233
Notes:
Qo$fgn Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Dasign Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 °F
Inside db 70 OF Inside db 75 OF
Design TD 31 °F Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure +1282 Btuh Structure 15262 Btuh
Ducts 3308 Btuh Ducts 4672 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 14590 Btuh Use manufacturer's data n
Ratelswin multiplier 1.00
Infiltration Equipmenfsensible load 19934 Stuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2253 Btuh
Ducts 997 Btuh
Heating Coolin Central vent (0 cfm) 0 Btuh
Area (W) 1324 132 Equipment latent load 3250 Btuh
Volume (ft') 11916 11916
Air changesthour 0.45 0.23 Equipment total load 23184 Btuh
Equiv.AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tem�pstar Make Tempstar
Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R410A HP
Model NXH530GKA* Cond NXH530GKA*
AHRI ref no3670844 Coll FXM4X30**A*
AHRI ref no3670844
Efficiency 8.7 HSPF Efficiency 12.5 EER, 15.3 SEER
Heating input Sensible cooling 20160 Btuh
Heating output 28600 Btuh @ 47*F Latent cooling 8640 Btuh
Temperature rise 27 OF Total cooling 28800 Btuh
Actual air flow 960 cfm Actual air flow 960 cfm
Air flow factor 0.066 cfm/Btuh Air flow factor 0.048 cfm/Stuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�Rribti~Svft 2014-Mar-l1 11:00:23
1 Might•SultrS L.livor�sal S.0.24 PSU05995 Page 1
ACCk CaUserslCvwmerlDeollmentelwriphteoft WACTogus 7„51*n,ruo Calc MJB Front Dr)orfaoes: E