1763 E Park Ter 2014 HVAC CITY OF ATLANTIC BEACH
SJ 800 SEMINOLE ROAD
s)
j ;r ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000526 Date 4/07/14
Property Address . . . . . . 1763 E PARK TER
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
-------------------------------------
Application desc
duct work 1 cu 1 ahu
-------------------------------------
Owner Contractor
------------------------
HAGIST TRUST, JULIETTE B DONOVAN HEATING & AIR
1763 PARK TERRACE EAST 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 (904)0241-37gNVILLE BEACH FL 32250
---------- -----------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . Plan Check Fee . 00
Permit Fee 103 . 00 .
Valuation
Issue Date
Expiration Date . . 10/04/14
----------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
_--------------------------------------------------
Other Fees
STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
_ ________ ----
Fee summary Charged
Paid Credited ----Due---
_ ------ --
--------- ----------
----------
- . 00
Permit Fee Total 103 . 00 103 . 0000 00 . 00
Plan Check Total • 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00
Grand Total
107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
[OB ADDRESS: ( �] Q.' k ' e Q Q C PERMIT#
PROJECT VALUE $ 4G10 ARI# (0 q sl-Z 3 � REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING
SYSTEM INSTALLATION
Air Conditioning: Unit Tons Per Unit t Quantity Seer Rating- �
Heat: Unit Quantity I BTU's Per Unit 4L6 n gREQUIRED
Duct Systems: Total CFM
FIRE PREVENTION Quantity (Requires 3 sets of plans)
Fire Sprinkler System ( q
Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
(
Fire Hose Cabinets Quantity (Requires
3 sets of plans)
Commercial Hoods Quantity quires 3 sets of plans)
Fire Suppression Systems Quantity (Requires
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts BTU's
Gas Piping Outlets Boilers
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER: fo—r I c s Q
d or aband
Permit becomes void if work does not commencetrue and correct. All provisionmonth s of laws and ordinancesfy that I have read
iod or ork is governingthisonedwork wilsix l betcompliedbwith whether pecified or
Tis application and know the same to be
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance/�f construction.f
-� Phone Number lob
Property Owners Name -� 1��,p � �'��r � I�Q�S � 3�{�SfFax Z t(l 32q-]C-
Mechanical
7 y�
Mechanical Company 06Y►0041 ���a� L Office Phone
/�V�. 5 City T -$ i3c1, State F1 ZipS2150
Co. Address: ��S �� 6
License Holder(Print): a r►^ r State Certification/Registration#
Notarized Signature of License Holder
... 20
,,tinY:%Y, RICHARD TOMPKINS Before me this day
;.;A4rz
:. Commission#FF 040399
rExpires July 29,2017 ,s Signature of Notary Public
-.,'"A�P, 8pded TNu Troy Fen Imnnoe BOMS540
Job:
+`+ wri htsoft' Project Summary Date: 4/4/14
9 Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach, FL 32250 Phone:241-3785 Email: brandon@donovanac.com
Proiect Information
For: WILLIAMS
1763 Park Terrace E, Atlantic Beach, FL 32233
Notes:
Desiqn Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 95 °F
Outside db 39 F 75 °F
Inside db
Inside db 68 of 20 °F
Design TD 29 F Design L
Daily range 50
Relative humidity 53 gr/lb
Moisture difference 9
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17933 Btuh Structure 15831 Btuh
Ducts 6147 Btuh Ducts 12188 Btuh
Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh
Humidification
0 Btuh Blower 0 Btuh
0 Btuh
Piping 25135 Btuh Use manufacturer's data n
Equipment load Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28746 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1948 Btuh
Fireplaces 1 (Average) Structure Ducts 2178 Btuh Heating Cooling Central vent (33 cfm) 1196 Btuh
5322 Btuh
Area (ft z) 1794 1794 Equipment latent load
Volume(ft') 16146 16146 menoad 34068 Btuh
Air changes/hour 22 0.0. 54 Req ptotaltcapactotal lity at 0.70 SHR 3.4 ton
Equiv.AVF (cfm)
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade Trade
Model NXH542 Cond NXH542
ARI ref no. 6938234 Coil FXM4X42
ARI ref no. 6938234 15 SEER
Efficiency 8.7 HSPF Efficiency 28778 Btuh
Heating input Sensible cooling 12334 Btuh
Heating output 40908 Btuh @ 47°F Latent cooling 41112 Btuh
Temperature rise 27 °F Total cooling 1370 cfm
Actual air flow 1370 cfm Actual air flow 0.049 cfm/Btuh
Air flow factor 0.057 cfm/Btuh Air flow factor 0 in H2O
resure
Static pressure 0 in H2O Load sStaticensible heat ratio 0.84
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
2014-Apr-04 17:30:59
wrightsoft Right-Suite®Universal 7.1.01 RSU05996 Page 1
ACCA C:\Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N