1763 E Park Ter 2014 HVAC CITY OF ATLANTIC BEACH SJ 800 SEMINOLE ROAD s) j ;r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000526 Date 4/07/14 Property Address . . . . . . 1763 E PARK TER Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------- Application desc duct work 1 cu 1 ahu ------------------------------------- Owner Contractor ------------------------ HAGIST TRUST, JULIETTE B DONOVAN HEATING & AIR 1763 PARK TERRACE EAST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 (904)0241-37gNVILLE BEACH FL 32250 ---------- ----------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee 103 . 00 . Valuation Issue Date Expiration Date . . 10/04/14 ---------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . _-------------------------------------------------- Other Fees STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 _ ________ ---- Fee summary Charged Paid Credited ----Due--- _ ------ -- --------- ---------- ---------- - . 00 Permit Fee Total 103 . 00 103 . 0000 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 [OB ADDRESS: ( �] Q.' k ' e Q Q C PERMIT# PROJECT VALUE $ 4G10 ARI# (0 q sl-Z 3 � REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Tons Per Unit t Quantity Seer Rating- � Heat: Unit Quantity I BTU's Per Unit 4L6 n gREQUIRED Duct Systems: Total CFM FIRE PREVENTION Quantity (Requires 3 sets of plans) Fire Sprinkler System ( q Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) ( Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity quires 3 sets of plans) Fire Suppression Systems Quantity (Requires FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts BTU's Gas Piping Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: fo—r I c s Q d or aband Permit becomes void if work does not commencetrue and correct. All provisionmonth s of laws and ordinancesfy that I have read iod or ork is governingthisonedwork wilsix l betcompliedbwith whether pecified or Tis application and know the same to be ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance/�f construction.f -� Phone Number lob Property Owners Name -� 1��,p � �'��r � I�Q�S � 3�{�SfFax Z t(l 32q-]C- Mechanical 7 y� Mechanical Company 06Y►0041 ���a� L Office Phone /�V�. 5 City T -$ i3c1, State F1 ZipS2150 Co. Address: ��S �� 6 License Holder(Print): a r►^ r State Certification/Registration# Notarized Signature of License Holder ... 20 ,,tinY:%Y, RICHARD TOMPKINS Before me this day ;.;A4rz :. Commission#FF 040399 rExpires July 29,2017 ,s Signature of Notary Public -.,'"A�P, 8pded TNu Troy Fen Imnnoe BOMS540 Job: +`+ wri htsoft' Project Summary Date: 4/4/14 9 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach, FL 32250 Phone:241-3785 Email: brandon@donovanac.com Proiect Information For: WILLIAMS 1763 Park Terrace E, Atlantic Beach, FL 32233 Notes: Desiqn Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 95 °F Outside db 39 F 75 °F Inside db Inside db 68 of 20 °F Design TD 29 F Design L Daily range 50 Relative humidity 53 gr/lb Moisture difference 9 Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6147 Btuh Ducts 12188 Btuh Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh 0 Btuh Piping 25135 Btuh Use manufacturer's data n Equipment load Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28746 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1948 Btuh Fireplaces 1 (Average) Structure Ducts 2178 Btuh Heating Cooling Central vent (33 cfm) 1196 Btuh 5322 Btuh Area (ft z) 1794 1794 Equipment latent load Volume(ft') 16146 16146 menoad 34068 Btuh Air changes/hour 22 0.0. 54 Req ptotaltcapactotal lity at 0.70 SHR 3.4 ton Equiv.AVF (cfm) Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model NXH542 Cond NXH542 ARI ref no. 6938234 Coil FXM4X42 ARI ref no. 6938234 15 SEER Efficiency 8.7 HSPF Efficiency 28778 Btuh Heating input Sensible cooling 12334 Btuh Heating output 40908 Btuh @ 47°F Latent cooling 41112 Btuh Temperature rise 27 °F Total cooling 1370 cfm Actual air flow 1370 cfm Actual air flow 0.049 cfm/Btuh Air flow factor 0.057 cfm/Btuh Air flow factor 0 in H2O resure Static pressure 0 in H2O Load sStaticensible heat ratio 0.84 Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2014-Apr-04 17:30:59 wrightsoft Right-Suite®Universal 7.1.01 RSU05996 Page 1 ACCA C:\Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N