Loading...
1739 Live Oak Ln 2014 addtion remodel CITY OF ATLANTIC BEACH l 800 SEMINOLE ROAD . � ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000335 Date 4/01/14 Property Address . . . . . . 1739 LIVE OAK LN Application type description RESIDENTIAL ADDITION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 250000 ----------------------------------------- Application desc ADDITION AND REMODEL ---------------------------------------- Owner Contractor --------------------- ----- CZERKAWSKI, JOSEPH J BOSCO BUILDING CONTRACTORS 1739 LIVE OAK LANE 2158 MAYPORT RD. ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-0320 --- Structure Information 000 000 ADDITION/REMODEL Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . RESIDENTIAL Flood Zone ZONEX ------ ------------------- -------------------------------- ----- -Permit . . . . . . RESIDENTIAL ADDITION Additional desc . . Permit Fee . . . . 930 . 00 Plan Check Fee 465 . 00 Issue Date . . . . Valuation . . . . 250000 Expiration Date . . 9/28/14 ------------------------------------- Special Notes and Comments Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS 95 STATE DCA SURCHARGE 13 . Other Fees F�� pF`T ppb+ app r, PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITIF A"I°L�+II�TIC"BE'ACI3`(�RDiNA;C�D THE FLOaX 0 0 BUILDING CODES. CITY OF ATLANTIC BEACH r j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 jilt Application Number . . . . . 14-00000335 Date 7/01/14 Property Address . . . . . . 1739 LIVE OAK LN Application type description RESIDENTIAL ADDITION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 250000 ---------------------------------------------------------------------------- Application desc ADDITION AND REMODEL ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CZERKAWSKI, JOSEPH J BOSCO BUILDING CONTRACTORS 1739 LIVE OAK LANE 2158 MAYPORT RD. ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-0320 --- Structure Information 000 000 ADDITION/REMODEL Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE X ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Sub Contractor . . ERICKSON ELECTRICAL CONTRACTOR Permit Fee . . . . 109 . 80 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/28/14 ---------------------------------------------------------------------------- Special Notes and Comments Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City Right-of-way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS ---------------------------------------------------------------------------- PERMIT Q VE*eRLY IN ACCORDANGE WITH Ad.L '0 � THE FLOR19A• 00 BUILDING CODES. CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD r� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Jjilt Page 2 Application Number 14-00000335 Date 7/01/14 _ ----------------------------- Other Fees . STATE ELEC DBPR SURCHARGE 2_00----- ------ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- -- Permit Fee Total 109 . 80 109 . 80 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 113 . 80 113 . 80 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 04/24/2009 01: 02 1904641983'' 1 PAGE 01/01 E .ECTRICAL PERMIT APPLICATION Crff O)F'ATLANTIC BEACH j Seminole Rd, Atlantic Beach, FL 32233 / Ph (904) 247-5826 Fax (904)247-5845 Jos ADDRESS: PERMrr# i t JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS \ PHASE VALUE OF WORK S NEW SERVICE ❑ Overhead ❑ Underground D Underground up Pole 0 Residential(Main)Service 00-100 amps 0101-150amps C 151-200amps 0 amps #of Meters Commercial(Main)Service 00-100 amps 0101-150amps 0151-200amps 0 amps OCT Service amps Conductor Type Size Multi-Family(Main)Service 00-100 amps 0101-150amps [1151-200amps 0 amps #of Unit Meters 0 Temporary Pole 0 amps SERVICE UPGRADE 0-amps 0 CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) 0100 amps 0150amps 0200amps 11 amps ECT Service amps ADDITIONS,REMODTO-60amps AIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. outlets/Switches: -30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps .A1C Circuits: �61-100amps Heat Circuits: Z # circuits @ k Number of Lighting outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS OSwitnming Pool 0 Sign [D Smoke Detectors_Qty 0Transformers KVA OMotors by FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK S Qty volts/amps REPAIRSJMISCELLANEOUS COR to UG 0 Replace Burnt/Damaged Meter Can 0 Safety Inspection 0 Panel Chaup 0 other: Permit becomes void if work does not oommence within a six month period or work is suspended or abandoned for six monft, l hereby certify that 1 Gave read this application and know the same to be true and correct. All provisions of laws and ordinances govemft this work will be complied with whether specified or not The permit does not give authority to violate the provisions of any other stage or local law regula600 eonstmetion or the performance of construction_ ,q ` Property owners Name Phone Number (TC 1 0�� Office Phone Fax Electrical Company `Q Co.Address: City State Zip '` State Certification/Registration License Holder(Print): Notarked.Signature of License Holder Sworn and subscribed befond me this day of 24 Signature of Notary Public r et z f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j - ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 C Page 2 Application Number . . . . . 14-00000335 Date 4/01/14 ----------------------------------------------------------------- Other Fees . . . . . . . . . STATE DBPR SURCHARGE 13 . 95 UTIL REV PRE APP >3 HRS 25 . 00 --------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ------ Permit Fee Total 930 . 00 930 . 00 . 00 . 00 Plan Check Total 465 . 00 465 . 00 . 00 . 00 Other Fee Total 77 . 90 77 . 90 . 00 . 00 Grand Total 1472 . 90 1472 . 90 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION . CITY OF ATLANTIC BEACH FILE COPY , 800 Seminole Road, Atlantic Beach, FL 32233 7 Office (904) 247-5826 Fax (904) 247-5845 Job Address: oat LamE Permit Num &, Legal Description . — Parcel # Floor Area o q. t. q. t Valuation of Work $ S0 Proposed Work heated/cooled non-heated/cooled Class of Work (circle one): New rtwn Alteration Re air Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): CommercialIres-id-e-nill If an existing structure,is a fire sprinklelpyste ills rd? (Circle one): es No N /A Florida Product Approval # For multiple products use product approval forKm Describe in detail the type of work to be performed: 71 Property Owner Information: Name. C Address: City StaterLZip Phone �- E-Mail or Fax # (Optional) piV �f. Contractor Information: -jpCompany Name: ali i Age t: Address:Z City 2 State Zip Office Phone - Job Site/Contact Number gQl f—233n= Fax# State Certification/Registration# 125�2 t Z Architect Name& Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void tf work is not commenced within six(6)months, or if construction or work is sus ended or abandoned for a period of six 6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells, Pools, furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that 1 have read and examined this plication and know the same lobe true and correct. All provisions of laws and ordinances governing this ape o1 work will be complied with whether s�eci red herei or not. The granting of a permit does not presume to give author' to violate or cancel the provisions of any other federal,state, or local law regulatin construction or the performance of construction. Signature of Owne tgnature of Contract Tint Name t1f/1.J���!�-�.bx-!..........._._....... Print Name �> ....... . ... Sworn t an subscrib d fore me Swor o an subscr' before me 20 4his 20 this t � " MARIA PIMIENTA ° IA PIMIENTA Notary Public-State of Florida P b iC :, x otary Putinc-state of Fbrlda My Comm.Expires Jan 26,2015 ?s r;, My Comm.Expires Jan 26,2015 ",OF PLOP� Commission#EE 59080 -;F OFVit 1 1ZC��i��a�►�ryasrD�A�®E 59080 P1,11 11 �t111tltt DO NOT WRITE BELOW- OFFICE USE ONLY App ica e odes: 2010 FLORID. BUILDINGCODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: 3--17-lel DevelopmentFILE COPY Size Habitable Space 37 Tq Non-Habitable ya7 S F Impervious area Miscellaneous Information Occupancy Group r2 - 3 -° Type of Construction V 0 Number of Stories I Zoning District S L_ Max. Occupancy Load Fire Sprinklers Required Flood Zone Az)4 Conditions/Comments: From:BOSCO BUILDING CONTRACTORS INC 904 241 0326 03/12/2014 14:36 #887 P.001/001 NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATES � F ! L E COPY Permit No /(/- -S Tax Folio No. a State off(,.0 f p County of To whom it may concern: The undersigned hereby informs you that Improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. �( �l Legal description of property being improved:Jr(-N 09-25-M k/A&V lh�j _ Address of property being improved: OM Live Na—��- &nju,17)c m General description of improvements: Owner Address jjjq Owner's interest in site of the improvement im Fee Simple Titleholder(if other than owner) Name . Address Contractor 805C.0 F%U 1 LD I!1 fr D/�ITj2RCT�2S 1 wl� Address I55-i ln,,- (+ is w � Phone No. qDq-- a4l-aap?J Fax No. Surety jif any) Address aAmount of bond S Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address IN 111 Phone No. rt Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address PhoneN . o Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY L_ 0 NE Signed: ATE 2 Before"this LIJ.LlUday of Fn ne _ County of 5 to 1 FtoM4,ha p na 40"red Doc 112014055371,OR BK 16716 Page 197, herein by Nbar Pages:1 himeelt/herself and aftrms that all um Recorded 0 311 2/201 4 at 0216 PM, are true and accurate �y�r,. Ronnie Fussell CLERK CIRCUIT COURT DUVAL M MARIA PIM"M COUNTY Notary Puotic-State of Harks RECORDING$10.00 y My Comm.Expires Jan 26,2015 ' Commission r EE$9090 -- Nary is t ar ,Stale of C mty of My W mission expi es: Perap ally Known or Produced IdeMificaWn L Map Output Page 1 of 1 JAXGIS Property Information » � j t .,..._.. vs• ass -- I , I 1720"OUG t 1 o'.i•crwanuw6 dw ewbo nwzww ns ,f \\ y F ---- ---------— Transac#o ap EDC vacua# PAC al tv I HH Iv I 9h#n E# Name Price cre ook-Page ne egal Descriptions / shSit one one one P N one thou thou once one ayport 1739 51 09-2S-29E of of in A I or¢oMa VE OAK LN 72020018 ZERKAWSKI JOSEPH OAK BEAC 100 71 �.11;0227409 ELVA MARINA UNI A tte nterpris AT 2 tannin A A A ce A A A A 2233 OT 4 K 1 e one ist: 300' FILE copy http://maps.coj.net/WEBSITE/DuvalMapsSQL/toolbar.asp 3/19/2014 rsr� l;,J City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) s 800 Seminole Road Atlantic Beach, Florida 32233-5445 d Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: �Q City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 17SI Zia JA,k- L-77 DepartMent review required Ye No Build Panning &Zoni Applicant: /�' J / ree ministrator Project: ��-�"1G� 0`L!'X 4C(E C_., ulicworks is tilities Public Sae y Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: QUILDIN PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: [-]Approved as revised. ❑De ied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER J +� Building Department (To be assigned by the Building Department.) =� 800 Seminole Road Atlantic Beach, Florida 32233-5445 REC Phone(904)247-5826 • Fax(904)247-58 5 J,3 T E-mail: building-dept@coab.us MAR,1 1 ?014 Date routed: m City web-site: http://www.coab.us BY: APPLICATION REVIEW AN I RAC ING FORM Property Address: /Ul Zivi oak l-77 D art+s;.� nt review required Yes No Buil Applicant: / '/'� P anniny & Zon J / ree ministrator Project: �-i� is tilities Public Sa ety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Rece: Date of Permit Verifier y Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. []Denied. (Circle one.) Comments: BUILDING / PLANNING &ZONING Reviewed by(,_P___— Date:8–/ _^/ TREE ADMIN. Second Review: []Approved as revised. ❑Denie- P Comments: IC UTILITIES PUBLIC AFETJ Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denie, Comments: Reviewed by: Date: Revised 05/14/09 r� 1r City of Atlantic Beach APPLICATION NUMBER Building Department s y s Department.) o be assigned b the Buildin De artment. - 800 Seminole Road / Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904) 247-5845 Date routed: �Q E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1759 Zia Qa'� Z-� D ent review required Yes No Buil Applicant: / 'I'� Panning X Zoni 1 / ee ministrator Project: �i��ln 4 ddE C__. u lid Works is tilities Public S1 y Fire Ser,?,ces Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Dateof Permit Verified_By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: BXpproved. []Denied. (Circle one.) Comments: BUILDING PLANN�ZONIN Reviewed Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denie,<. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 T+ � City of Atlantic Beach !' C �, `� ! APPLICATION NUMBER Building Department ` o be assigned by the Building Department.) -� 800 Seminole Road I MAR.1 Z ?m _ ? Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247- i Of �a E-mail: building-dept@coab.us )ate routed: '111Q Zz ez— City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 17SI Zia DA,& 1-i? DpartMent review required Yes No Build Applicant: / P anninc Zonjijo / 'Tge�-M nistrator Project: ��,�&n c>" 0�j'X Odd C� u lic v�'_+rks is I+`hies Public Si qty Fire Ser -es Review fee $ Dept Signature Other Agency Review or Permit Required Review or Rec Date of Permit Verifie Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUKDenie Reviewing Department First Review: ❑Approved. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: qApproved as revised. ❑Denic� PUBLIC WORKS Comments: P PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied Comments: Reviewed by: Date: Revised 05/14/09 7 � DocuSign Envelope ID:CF5FIA7"5D44AA7.98E4-gEC514E452AA flexmis Web e 2 of 10 MAR 2 4 2014 FILE COPY i 13Y BOUNDARY I WOWAMW�*WASP SURVEY rc cr Lar 9.%=0 LOT 5 BLOCK 10 C;ro FVCE t3 FENCE Is (Lr ON IX w n,o wi 4 q3 PZ lo 0 'A vs vs I'Rcm MQ NLA� 4�,3s FE4m Is to 4. %M 0.,V M 4" 0 LOT 4 BLOCK 10 LOT 3 41U BLOCK 10 kw .No Pm No%am ac %s NOT A PART CF TH(S PLAT �t Al 1Y PROPERTY ADDRESS: 1739 LIVE OAK LANE-ATLANTIC RRAM FLORIDA 32233 Leila L)csaiptom LOT 4,DLOrXl*..nU.VAUAJtL4ALWr(,ACCCPDDl 1O TM pLAI neXZU.A51W-0R13E0 LN MAX BOUL34,PACO SI.31A Ld.UF 7H9FL1UC11hM1t"80f 1ANAL"AIN-1Y.Fic)"3A NAY:c?iIv CERTIFIED TO: (AS FURNISHED) CLEXT P.Ot wol-Agg JA NO: 1400&9AW"*PASO FIELD DATE 01/14,7M WEM Kw Lum(A Owl"JF APPROWD a%-Aa- (VFCKV0 BY' ALL DIA"BY- on ljttp:/,,nef flexmls.com/cgi-bin/mainmenu.cL!l 3/24/201 I r DocuSi n Envelope 10:CF5F1A76-6504-4AA7-98E4-9EC514E452AA ua-uSV r-nvat"lu:y�uuar�uw����+car-Hvattittlourur-z a Page 3 of 10 tlexmis Web .fTlC.L t Wn!*a�t1p Vut U■.r.y I�Kti W rye IA+W••1��ww M .ar- •f»�a�s.aacJaana I 3wt.r. .M4e..�n.MA...re��ar�d:be.gnvaw. rcc -^wwmawr.w+oa.Y.fua IlsildNnirioullrrp�ud/47w�0upr41SV4.n&ft S1'!wM r.fr •'.1n�.ft n,1ti Mw.v.Iro(I p-.17CT, .tY -e1twYOf��'w� JrOIWpJiNTYLY gnwa�aC,�iCAIE.'1� 4d .�y(iMof.CLN� wV d.0 •,run s.w�rt - ' .arwu.wsi�t n.ecnzorr ;f.■asc-.Lnnautrconsusa) m A1,w G pOmM J!iL Mr.6e17 N" nr�:rra+.-.af„wm.r.+«.< ..rte• w f p O.rx)X 17cwM,Lk"MONHOF,PL 12747 m w.�f� w nw+•x..r�*a e.._w.�"'M`.e.'i�'m��Yuf.rnva�.� 3?7.�51.]if2(OtI'.ue�:3075Z6.S 453(F+at):.D MISCA 'W:ll.11i. BIIIY :;:a w..r�r..r.nyswf�.. �j '.t7f'61�3'L'3l� uonravavns,e�r�u•Yrenu�ou�+�a�v:m�rae�,�.ww� A3 w`.4■,h.o��� rrea�rwr��sm■�q� pyp��a MTR Pavq�ON Oa':C uiwwOM '.!W'Y114......t'I.��'•1•w. r.,�MO11..wr��y+�■��R I60W fI�OLtn�ri�f 11t�i1' flf'1 Y�i•Y ITT�� ..f♦. .f. I�.n .r..�r�..-� .n.. ...- R . usiness Professional Regulation _. FILE COPY 4 K•;='"'4'a`'� BCIS Home tog In User Registration Hot Top,csi, Sul"n"I Su FtF & nrge++iZtats- +JfGW` Publications FBC Staff BCIS Site Map Links Search �,.Business .. ...... �...�..:s�...��:.�.� h..�4.. Prod Appoval Professional USER UPublic User PrnA n Approvail M >Rmzlija n,Applicationc n >Apnficat nn t LIf >Application Detail FL # FL11267 R4 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Overhead Door Corporation Address/Phone/Email 2501 S. State Hwy. 121, Suite 200 Lewisville, TX 75067 (469) 549-7031 mark–sawicki@overheaddoor.com Authorized Signature MARK SAWICKI niark_sawicki@overheaddoor.com Technical Representative Mark Sawicki Add ress/Phone/Erna il 2501 S. State Hwy 121, Suite 200 Lewisville, TX 75067 (469) 549-7031 mark_sawicki@overheaddoor.com Quality Assurance Representative Carol Currence Address/Phone/Email One Door Drive P.O. Box 67 Mt. Hope, OH 44660 (330) 763-8091 ccurrenc@wayne-dalton.com Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Mark A. Sawicki Evaluation Report Florida License PE-72613 Quality Assurance Entity Intertek Testing Services NA Inc. - ETL/Warnock Hersey Quality Assurance Contract Expiration Date 12/31/2015 Validated By Gordon Thomas, P.E. Validation Checklist - Hardcopy Received Certificate of Independence E'11267–R4– Fit �F� oe rrn t i n n c 4 pdf Referenced Standard and Year(of Standard) Standard Yeas ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886/1996 2005 ASTM E330 2002 TAS 201/203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect ELI 1267 R4,Fquitt_AS7-t1 EI991i05leLt-5 -I-wi Florida Building Code Online "' " `- Page 1 of 3 FILE COPY Business & Professional �dbi Qwnl pf SCIS Rome lop In User Req niraibn Not Tdpin Submit Sun:narpe Slats 6 Facts PubkcalbnE � FOC 51011 SCIS See Map � •links Seerth Busines ���� ProfessionalJDLf� product Approval USER:Pu tNlc User Regulatt�i�o�aEEn����E�� �--B�7LiLr1L.Y� Pmeurt A'cf"°APIC"">C1Ds1vu nr AnNlctuon set cn>4120111,111111 1151>Appliutlon Detail Fi.t FL5414-RB Application Type Revision Code Version 2010 Application Status Approved •Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer Simonton Windows Address/Phone/Enull 1 Cochrane Ave Pennstiorc,WV 26415 (800)746-6687 Ext 2329 tiffany_davICSOSImonton.tom Authorized Signature Tiffany Davies t l ff a n y_d a vl es®s l mo n to n.com Technical Representative Tlffany Davies Address/Phone/Emall PO Box 1646 5300 Brlsme Road Parkersburg,WV 26102 (SDO)542.9116 Ext 9329 llffany_da v les®slm onion.c o m Quality Assurance Representative MMA Address/Prone/E mall 1827 Walden Office Square Suite 550 Schaumburg,IL 6D173 (847)303-5664 webmaste r0aama net.org Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certlficatlon Agency American Architectural Manufacturers Assodation Validated By American Architectural Manufacturers Association Rererenced Standard and Year(or Standard) S[nndard YSIII AAMA/WDMA/CSA 101/1.5 2/A440 2005 AAMA/WDMA/CSA 101/1.5 2/A440 2008 t Equivalence of Product Standards Certified By Product App.oval Method Method 1 Option A Date Submitted 04/16/2013 Dale Validated 05/06/2013 litip://w.vNN,.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQ%vtDg1H,1PNvMo6eHrn... 8/8/201 j,%- pian i'AtiM`N..`o.1:...wTr akiMt`---" .Ml"•/At LECOPY " � 1 FORM 405-1 �;` � `.,. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Czerkawski Addition 1739 Live Oak Ln Builder Name Bosco Building Contractor,Inc Street: 1739 Live Oak Lane Permit Office Duval City,State,Zip: Atlantic Beach.FL .32233 Permit Number: Owner: Czerkawski Jurisdiction: 261100 Design Location: FL,Jacksonville 1 New construction or existing Addition 9. Wall Types(3219.6 sgft) Insulation Area 2. Single family or multiple family Single-family a Frame-Wood,Exterior R=11 0 3039.60 ft b.Frame-Wood.Adjacent R=11 0 180.00 ft' 3. Number of units,if multiple family 1 c.N/A R= fF 4 Number of Bedrooms(Bedrms In Addition) 5(5) d.N/A R= ft, 5. Is this a worst case? No 10.Ceiling Types (3984.0 sgft,) Insulation Area a.Under Attic(Vented) R-30.0 3812.00 ft' 6. Conditioned floor area above grade(ft') 3812 b.Under Attic(Vented) R=19.0 172.00 ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft' 7. Windows(848.7 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 228 a. U-Factor: Dbl,U=0.33 848.70 fN SHGC: SHGC=0.33 b. U-Factor: N/A f 2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 72.0 SEER:13.00 c. U-Factor: NIA ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 72.0 HSPF:7.70 SHGC: Area Weighted Average Overhang Depth: 4.995 ft. Area Weighted Average SHGC: 0.330 14.Hot water systems - 8. Floor Types (3812.0 sga.Natural Gas Tankless Cap:1 gallonsft.) Insulation Area EF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 3812.00 ft' b. Conservation features b.N/A R- ft' None c.WA R= ft' 15.Credits Pstat Glass/Floor Area: 0.223 Total Proposed Modified Loads: 53.60 PASS Total Standard Reference Loads: 67.06 1 hereby certify that the plans and specifications covered by Review of the plans andTHE 5742, this calculation are in compliance with the Florida Energy specifications covered by this o 2� ,FOS Code. calculation indicates compliance vj�Gy ,`ta 0� IL with the Florida Energy Code. PREPARED BY: ___ _ _ Before construction is completed c3 DATE: 6 121./�__ _ this building will be inspected for V b compliance with Section 553.908 ° 1 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD Wr, O OWNER/AGENT BUILDING OFFICIAL: DATE: _. _ - - I_. . _ _ DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 2!21/2014 6 14 PM EnergyGauge®USA- FlaRes2010 Section 405.4 1 Compliant Software Page 1 of 7 PROJECT Title: Czerkawski Addition 1739 Live Bedrooms: 5 Address Type: Street Address BuildingType: User Conditioned Area: 3812 Lot# Owner: Czerkawski Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Bosco Building Contractor,Inc Rotate Angle: 0 Street: 1739 Live Oak Lane Permit Office: Duval CrossVentilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip Atlantic Beach, Family Type: Single-family Fl 32233- New/Existing: Addition Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp DesignLocation TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 3812 30496 SPACES Number Name Area Volume Kitchen occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3812 30496 Yes 6 5 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 253 ft 0 3812 ft' ---- 0.3 0.7 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel tile 4017 ft' 634 ft' Medium 0.96 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Fullattic Vented 300 3812 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Frac TrussType 1 Under Attic(Vented) Main 30 3812 ft' 0.11 Wood 2 Under Attic(Vented) Main 19 172 ft' 0.11 Wood 2/21/2014 6:14 PM EnergyGauge0 USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Sace 0rnt ---In Wall Type P c R-Value Et In Ft In Area R-Value Fraction Absor- Grade%- _ 1 NW Exterior Frame-Wood Main 11 26.5 0 8 0 212 0 ft' 0 0.8 0 _ 2 SW Exterior Frame-Wood Main 11 14 0 8 0 112.0 ft' 0 0.8 0 3 SW Exterior Frame-Wood Main 11 18.7 0 8 0 149.6 ft' 0 08 0 _ 4 NW Exterior Frame-Wood Main 11 11.5 0 8 0 92.0 ft' 0 0.8 0 5 NE Exterior Frame-Wood Main 11 4 0 8 0 32.0 ft' 0 0.8 0 6 NW Exterior Frame-Wood Main 11 13 0 8 0 104.0 ft' 0 08 0 7 NE Exterior Frame-Wood Main 11 14 0 8 0 112.0 ft' 0 0.8 0 8 NE Exterior Frame-Wood Main 11 6 0 8 0 48 Oft' 0 0.8 0 9 NE Exterior Frame-Wood Main 11 6 0 8 0 48.0 ft' 0 0.8 0 10 NE Exterior Frame-Wood Main 11 8 0 8 0 64.0 W 0 0.8 0 _11 NE Exterior Frame-Wood Main 11 8 0 8 0 64.0 ft' 0 0.8 0 _12 NE Exterior Frame-Wood Main 11 13 0 8 0 104.0 ft' 0 0.8 0 _13 SE Exterior Frame-Wood Main 11 20 0 8 0 160.0 W 0 0.8 0 14 SE Exterior Frame-Wood Main 11 31 0 10 0 310.0 ft' 0 0.8 0 15 NW Exterior Frame-Wood Main 11 17 0 8 0 136.0 ft' 0 0.8 0 16 NE Exterior Frame-Wood Main 11 12 0 8 0 96.0 ft' 0 0.8 0 17 SE Exterior Frame-Wood Main 11 18 0 8 0 144.0 ft' 0 0.8 0 18 SW Exterior Frame-Wood Main 11 12 0 8 0 96.0 ft2 0 0.8 0 19 SE -Exterior Frame-Wood Main 11 14 0 8 0 112.0 ft' 0 0.8 0 20 SE Exterior Frame-Wood Main 11 11 0 8 0 88.0 ft' 0 0.8 0 _21 SW Exterior Frame-Wood Main 11 5 0 8 0 40.0 ft' 0 0.8 0 22 SE Exterior Frame-Wood Main 11 8 0 8 0 64.0 ft' 0 0.8 0 23 NE Exterior Frame-Wood Main 11 10 0 8 0 80.0 ft' 0 0.8 0 _24 SW Exterior Frame-Wood Main 11 5.5 0 8 0 44.0 ft2 0 0.8 0 _25 SW Exterior Frame-Wood Main 11 4 0 8 0 32.0 ft' 0 0.8 0 _26 SE Exterior Frame-Wood Main 11 5.5 0 8 0 44.0 ft' 0 0.8 0 _27 SW Exterior Frame-Wood Main 11 13 0 8 0 104.0 ft' 0 0.8 0 28 NE Exterior Frame-Wood Main 11 26 0 8 0 208.0 ft' 0 0.8 0 29 SW Exterior Frame-Wood Main 11 17.5 0 8 0 140.0 ft' 0 0.8 0 30 NW Garage Frame-Wood Main 11 22.5 0 8 0 180.0 ft' 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Wood Main None 0.46 0.1 0.1 0.010000 2121/2014 6 14 PM EnergyGauge®USA-FlaRes2010 Section 405 4 1 Compliant Software Page 3 of 7 ,b WINDOWS Orientation shown is the entered,Proposed orientation / Wall Overhang �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.33 80.4 ft' 1 ft 0 in 1 ft 0 in None None 2 NW 1 Vinyl Low-E Double Yes 0.33 0.33 20.1 ft' 29 ft 0 in 1 ft 0 in None None 3 SW 2 Vinyl Low-E Double Yes 0.33 0.33 33.5 W 6 ft 0 in 0 ft 0 in None None 4 SW 3 Vinyl Low-E Double Yes 033 0.33 33.5 ft' 6 ft 0 in 1 ft 0 in None None 5 SW 3 Vinyl Low-E Double Yes 0.33 0.33 12.5 ft' 1 ft 0 in 1 ft 0 in None None 6 NW 4 Vinyl Low-E Double Yes 0.33 0.33 25.0 ft' 1 h 0 in 1 ft 0 in None None 7 NE 5 Vinyl Low-E Double Yes 0.33 0.33 12.5 ft' 1 ft 0 in 1 ft 0 in None None 8 NW 6 Vinyl Low-E Double Yes 0.33 0.33 25.0 ft' 1 ft 0 in 1 ft 0 in None None 9 NE 7 Vinyl Low-E Double Yes 0.33 0.33 15.0 ft' 1 ft 0 in 1 ft0 in None None 10 NE 8 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 ft 0 in 1 ft 0 in None None 11 NE 9 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 ft 0 in 1 ft 0 in None None 12 NE 10 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 h 0 in 1 ft0 in None None 13 NE 11 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 ft 0 in 1 ft 0 in None None 14 NE 12 Vinyl Low-E Double Yes 0.33 0.33 25.0 ft' 1 ft0 in 1 ft 0 in None None 15 SE 13 Vinyl Low-E Double Yes 0.33 0.33 33.5 ft' 1 ft 0 in 1 ft0 in None None 16 SE 14 Vinyl Low-E Double Yes 0.33 0.33 100.5 ft' 9 ft 0 in 1 ft 0 in None None 17 NW 15 Vinyl Low-E Double Yes 0.33 0.33 10.5 ft' 1 ft 0 in 1 ft0 in None None 18 NE 16 Vinyl Low-E Double Yes 0.33 0.33 40.2 ft' 20 ft 0 in 1 ft0 in None None 19 SE 17 Vinyl Low-E Double Yes 0.33 0.33 58.5 ft' 1 ft 0 in 1 ft 0 in None None 20 SE 17 Vinyl Low-E Double Yes 0.33 0.33 5.0 ft' 1 ft0 in 1 ft 0 in None None 21 SW 18 Vinyl Low-E Double Yes 0.33 0.33 40.2 ft' 16 ft 0 in 1 ft0 in None None 22 SE 19 Vinyl Low-E Double Yes 0.33 0.33 40.2 ft' 9 It 0 in 1 ft 0 in None None 23 SE 20 Vinyl Low-E Double Yes 0.33 0.33 15.0 ft' 1 ft 0 in 1 ft 0 in None None 24 SW 21 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 ft 0 in 1 ft 0 in None None 25 SE 22 Vinyl Low-E Double Yes 0.33 0.33 7.5 ft' 1 ft 0 in 1 ft 0 in None None 26 NE 23 Vinyl Low-E Double Yes 0.33 0.33 40.2 ft' 1 ft 0 in 1 ft 0 in None None 27 SE 26 Vinyl Low-E Double Yes 0.33 0.33 27.2 ft' 1 ft 0 in 1 ft 0 in None None 28 SW 27 Vinyl Low-E Double Yes 0.33 0.33 25.0 ft' 1 ft 0 in 1 ft 0 in None None 29 NE 28 Vinyl Low-E Double Yes 0.33 0.33 25.0 ft' 1 ft 0 in 1 ft 0 in None None 30 NE 28 Vinyl Low-E Double Yes 0.33 0.33 40.2 ft' 1 ft 0 in 1 ft 0 in None None 31 SW 29 Vinyl Low-E Double Yes 0.33 0.33 20.0 ft' 1 ft 0 in 1 ft0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 384 ft' 384 ft' 64 ft 8 ft 11 2121/2014 6 14 PM EnergyGauge®USA-FlaRes2010 Section 405 4 1 Compliant Software Page 4 of 7 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse BestGuess 0.000300 2999.68 164 678 309.702 023100 5.90178 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block_ Ducts 1 A Electric Heat Pump None HSPF:7.7 48 kBtu/hr 1 sys#1 1 B Electric Heat Pump None HSPF:7.7 24 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR _ Block Ducts 1 A Central Unit None SEER:13 48 kBtu/hr 1440 cfm 0.75 1 sys#1 1 B Central Unit None SEER:13 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.59 1 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None W DUCTS / ----Supply---- ----Return--- Air CFM25 HVAC# Location R-Value Area Location Area Leakage Type Handler CFU125 OUT QN RLF Heat Cool 1 A Attic 6 533 ft' Main 133 ft' Default Leakage Main cfm (Default) 1 1 1 B Attic 6 228 ft2 Main 57 ft' Default Leakage Main cfm (Default) 1 1 TEMPERATURES Program able Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr [ j Ma X Jun rj Julri Au rl Se Oct Nov Dec HeatinJan Feb HMar f AP I ]May 4j Jun Jul AuSep Oct Nov Dec Ventin HJan Feb Mar IX]A r [ ]Ma [ Jun Jul Aug Se [X]Oct N Nov H Dec 2/21/2014 6 14 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/21/2014 6:14 PM EnergyGauge®USA-FlaRes2010 Section 405 4 1 Compliant Software Page 6 of 7 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 1739 Live Oak Lane PERMIT #: Atlantic Beach, FL, 32233- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION 1 SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 2/21/2014 6 14 PM EnergyGauge@ USA-FlaRes2010 Section 405 4 1 Compliant Software Page 7 of 7 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 1739 Live Oak Lane, Atlantic Beach, FL, 32233- 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 3039.60 ft' b. Frame-Wood,Adjacent R=11.0 180.00 ft' 3. Number of units,if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 5(5) d. N/A R= ft' 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 3812.00 ft' 6. Conditioned floor area(ft') 3812 b.Under Attic(Vented) R=19.0 172.00 ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Dbl,U=0.33 848.70 ft' 11.Ducts R ft' SHGC: SHGC=0.33 a.Sup:Attic,Ret:Main,AH:Main 6 228 b. U-Factor: N/A ft' SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 72.0 SEER:13.00 SHGC: d. U-Factor: N/A ft' 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 72.0 HSPF:7.70 Area Weighted Average Overhang Depth: 4.995 ft. Area Weighted Average SHGC: 0.330 8. Floor Types Insulation Area 14.Hot water systems- Natural Gas Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 3812.00 ft a. EF:0.59 b.N/A R= ft' c.N/A R= ft' b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building qHE ST Construction through the above energy saving features which will be installed(or exceeded) �� 4P .� .n in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: - a 4 Address of New Home: City/FL Zip: g� Dov WE•fio *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project NameCzerkawski Addition 1739 Live Oak Ln Builder Name: Bosco Building Contractor, Inc Street: 1739 Live Oak Lane Permit Office. Duval City,State,Zip: Atlantic Beach ,FL ,32233- Permit Number. Owner: Czerkawski Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows abd doors Space between window/doorjambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. $hower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGaugeO USA-FlaRes2010 Section 405.4 1 Compliant Software e � t I . FILE L% I i Czerkawski Addition 1739 Live Oak Ln Atlantic Beach, FL HVAC Load Calculations for Bosco Building Contractor, Inc 2158 Mayport Road Atlantic Beach, FL 32233 El ite o ftiiwa r e RHVACRESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS Prepared By: Jim Williams Home Energy Services 2080 Davis Rd Jacksonville FI 32218 7573569 Friday, February 21,2014 it Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. i 3 Rhvac Residential 8 Light Commercial HVAC Loads Elite Software Development, Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 Page 2 Project Report - General Project Information Project Title: Czerkawski Addition 1739 Live Oak Ln Atlantic Beach, FIL Project Date: Friday, February 21, 2014 Client Name: Bosco Building Contractor, Inc Client Address: 2158 Mayport Road Client City: Atlantic Beach, FL 32233 Client Phone: 904-241-0320 Client Fax: 904-241-0326 Client E-Mail Address: Todd@Boscocustomhomes.com Company Name: Home Energy Services Company Representative: Jim Williams Company Address: 2080 Davis Rd Company City: Jacksonville FI 32218 Company Phone: 7573569 Company E-Mail Address: jimwilliams@homebuildingstore.com De: gio Data.. — Reference City: Jacksonville, Florida Building Orientation: Front door faces Northwest Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 ft. Altitude Factor: 0.999 . Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 80% n/a 70 n/a Summer: 94 77 47% 50% 75 48 .Check Figures _ Total Building Supply CFM: 2,591 CFM Per Square ft.: 0.680 Square ft.of Room Area: 3,812 Square ft. Per Ton: 708 Volume(ft')of Cond. Space: 32,416 MENs — Total Heating Required Including Ventilation Air: 63,507 Btuh 63.507 MBH Total Sensible Gain: 56,954 Btuh 88 % Total Latent Gain: 7,656 Btuh 12 % Total Cooling Required Including Ventilation Air: 64,609 Btuh 5.38 Tons(Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I Friday, February 21, 2014, 6:22 PM Rhvac-Residential&Light Commercial HVAC Loads daim am` i Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 - page 3 Miscellaneous Report _ System 1 Main Outdoor Outdoor Outdoor Indoor Indoor sLIPP 2 Data --- ------- - -- Dry Bulb Wet Bulb Rel.8u Rel.Hu m y Bulb_- Difference Winter: Summer: 94 77 47% 50% 75 48.06 Outdoor ysnut D t-Master ---_--- Dry Bulb We BulbrT' l.H�r Indoor urn Rel.Hum _ Bulb Difference Winter: 32 29.92 80% n/a 70 n/a Summer: 94 77 47% 50% 75 48.06 Duct Sizing Inputs -- ----- ----- - -------- --- -- Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside AW-Data - - ---- - - - ----� Winter Summer - ---- - ----- --- Infiltration Specified: 0.250 AC/hr 0.250 AC/hr 135 CFM 135 CFM Infiltration Adtual: 0.250 AC/hr 0.250 AC/hr Above Grade Volume: X 32.416 Cu.ft. X 32.416 Cu.ft. 8,104 Cu.ft./hr 8,104 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 135 CFM 135 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration&Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(95 CFM) Summer Infiltration Specified: 0.250 AC/hr(95 CFM) ---System 2--- Infiltration&Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(40 CFM) Summer Infiltration Specified: 0.250 AC/hr(40 CFM) Duct Load Factor Scenarios for System 1 Attic Dud Duct Surface.'Y Fro No. Type Des; tion Location Ceiling Leakage Insulation _ ' '' MDD 1` Supply Main Attic 16B 0.09 6 726 No 1 Return Main Attic 16B 0.15 6 134 No Duct Load Factor Scenarios for System 2 Attic Duct Duct Surface Fro No. Type Description Location Ceiling Leakage Insulation Area MDD 1 Supply Main Attic 16B 0.09 6 303 No 1 Return Main Attic 16B 0.15 6 112 No l _ Friday, February 21, 2014, 6:22 PM Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 Page 4 Load Preview Report Net Rec ft'I ! Sen Lat' Net Sen Sys Sys Sys putt Scope Ton TonHtg Act Clg A' /Ton' Area Gain; Gain Gain Loss SizeCFM CFM CFM -- - Building 5.38 6.33 602 3,812 56,954 7,656 64,609 63,507 1,284 2,591 2,591 System 1 3.73 4.36 617 2,689 39,235 5,484 44,719 42,554 860 1,785 1,785 18x18 Duct Latent 1,377 1,377 Zone 1 2,689 39,235 4,107 43,342 42,554 860 1,785 1,785 18x18 1-Foyer 250 4,799 316 5,115 4,862 98 218 218 2-6 2-Bedroom 3 168 1,776 167 1,943 2,370 48 81 81 1--5 3-Bedroom 1 192 4,129 408 4,537 5,335 108 188 188 2-6 4-Bedroom 2 182 3,115 322 3,437 4,016 81 142 142 2-5 5-Bath 3 48 578 72 650 889 18 26 26 1-4 6-Bath 2 48 578 72 650 889 18 26 26 1-4 7-Laundry 60 684 95 779 1,150 23 31 31 1-4 8-Bath 1 48 656 95 751 1,131 23 30 30 1-4 9-Bedroom 4 300 4,203 394 4,597 5,168 105 191 191 2-6 10-Powder 42 97 0 97 64 1 4 4 1-4 11-Living 667 8,248 1,262 9,510 6,639 134 375 375 4--6 12-Kitchen 374 4,265 403 4,668 2,763 56 194 194 2-6 13-Breakfast/Dining 310 6,107 501 6,608 7,278 147 278 278 3-6 System 2 1.66 1.97 570 1,123 17,719 2,172 19,891 20,953 424 806 806 10x16 Duct Latent 668 668 Zone 1 1,123 17,719 1,504 19,223 20,953 424 806 806 10x16 14-Study 154 4,283 473 4,756 3,865 78 1.99 195 2-6 15-S WIC 45 521 55 576 735 15 24 24 1-4 16-Pantry 72 675 87 762 1,126 23 $1 31 1-4 17-Vestibule 192 2,072 109 2,181 1,931 39 g4 94 1-6 18-Bath 4 54 328 60 388 757 15 1'S 15 1-4 19-Water Closet 34 227 44 271 518 10 1t) 10 1--4 20-Master Bath 135 2,580 202 2,782 2,965 60 117 117 2-4 21-Master Bedroom 437 7,032 474 7,506 9,057 183 320 320 3-6 f Friday, February 21, 2014, 6:22 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville, FL 32218 _ _ _ Pa e-,� Duct Size Preview Room or Minimum Maximum! Rough. Design SP Duct Duct Duct Name Htg Clg Act. Duct _._ Velocity Velocity Factor L/100 Loss Velocity Length Flow System Flow Flowa _Size System 1 Supply Runouts Zone 1 1-Foyer 450 750 0 0.1 556 98 218 2-6 2-Bedroom 3 450 750 0 0.1 592 7 48 81 1-5 3-Bedroom 1 450 750 0 0.1 478.4 108 188 2-6 4-Bedroom 2 450 750 0 0.1 519.7 81 142 2-5 5-Bath 3 450 750 0 0.1 301,3 18 26 1--4 6-Bath 2 450 750 0 0.1 301.3 18 26 1-4 7-Laundry 450 750 0 0.1 356.5 23 31 1-4 8-Bath 1 450 750 0 0.1 342 23 30 1-4 9-Bedroom 4 450 750 0 0.1 487 105 191 2-6 10-Pander 450 750 0 0.1 50.3 1 4 1-4 11-Living 450 750 0 0.1 477.8 134 375 4-5 12-KHchen 450 750 0 0.1 494.2 56 194 2-5 13-Breakfast/Dining 450 750 0 01 471.7 147 278 3-6 Other Ducts in System 1 Supply Main Trunk 650 900 0 0.1 793.4 860 1,785 18x18 System 2 Supply Runouts Zone 1 14-Study 450 750 0 0.1 496.3 78 195 2-5 15-S WIC 450 750 0 0.1 271.7 15 24 1-4 16-Pantry 450 750 0 0.1 352.1 23 31 1-4 17-Vestibule 450 750 0 0.1 480.1 39 94 1-6 18-Bath 4 450 750 0 0.1 171 15 15 1-4 19-Water Closet 450 750 0 0.1 118.5 10= 10 1-4 20-Master Bath 450 750 0 0.1 672.6 60 117 2-4 21-Master Bedroom 450 750 0 0.1 543.1 183 320 3-6 Other Ducts in System 2 Supply Main Trunk 650 900 0 0.1 725.5 424 806 10x16 ------------------ Summary System 1 - - Heating Flow: 860 Cooling Flow: 1785 System 2 Heating Flow: 424 Cooling Flow: 806 Friday, February 21, 2014, 6:22 PM Rhvac-Residential 8 Light CommercW HVAC Loads Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 _ Page 6 Total Building Summary Load Component Area Sen Lat Sen Total Description Quart Loss Gain Gain Gain 10D-f: Glazing-French door, double pane low-e glass(e = 428.8 5,701 0 9,052 9,052 0.10), insulated fiberglass frame, u-value 0.35, SHGC 0.3 10D-f: Glazing-French door, double pane low-e glass (e = 33.5 382 0 400 400 0.10), insulated fiberglass frame, u-value 0.3, SHGC 0.3 4A-6-o: Glazing-Double pane low-e(e = 0.20 or less), 359.2 4,506 0 8,822 8,822 high performance, operable window, a=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.3 4A-6-d: Glazing-Double pane low-e(e = 0.20 or less), 27.2 341 0 711 711 high performance, sliding glass door, a=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.3 12B-Osw: Wall-Frame, R-11 insulation in 2 x 4 stud 2190.9 8,075 0 5,969 5,969 cavity, no board insulation, siding finish,wood studs 12B-Osw: Part-Frame, R-11 insulation in 2 x 4 stud cavity, 180 663 0 332 332 no board insulation, siding finish,wood studs 1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 3811.5 4,632 0 6,586 6,586 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal,Tar and Gravel or Membrane, R-30 insulation 166-19: Roof/Ceiling-Under Attic with Insulation on Attic 172 320 0 455 455 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-19 insulation 22A-ph-c: Floor-Slab on grade, No edge insulation, no 396 20,435 0 0 0 insulation below floor, carpet covering, passive, heavy moist soil _ Subtotals for structure: 45,055 0 32,327 32,327 People: 6 1,200 1,380 2,580 Equipment: 0 6,700 6,700 Lighting: 0 0 0 Ductwork: 12,810 2,045 12,599 14,644 Infiltration: Winter CFM: 135, Summer CFM: 135 5,642 4,411 2,821 7,232 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 1,127 1,127 Total Building Load Totals: 63,507 7,656 56,954 64,609 Check Figures Total Building Supply CFM: 2,591 CFM Per Square ft.: 0.680 Square ft. of Room Area: 3,812 Square ft. Per Ton: 708 Volume(ft3)of Cond. Space: 32,416 Building Loads T'otal Heating Required Including Ventilation Air: 63,507 Btuh 63.507 MBH Total Sensible Gain: 56,954 Btuh 88 % Total Latent Gain: 7,656 Btuh 12 % Total Cooling Required Including Ventilation Air: 64,609 Btuh 5.38 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Friday, February 21, 2014, 6:22 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 Page 7 Buildinn.q Pie_Chart i Infiltration 9% Floor 32%� Ductwork 20% Building Loss 63,507 Btuh Roof 8% Glass 17% Wall 14% ° ED Excursion 2% Roof 11% Infiltration 11% Wall 10% Building - Ductwork 23% Gain 64,609 Btuh Glass 29% Equipment 10% People 4% i Friday, February 21, 2014, 622 PM Rhvac-Residential&Light Commercial HVAC Loads i Elite Software Development,Inc. 1 Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 _ __Page 8 *stem 1 Room Load Summar i ^Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Zone 1- - ---- - -CFM- --- - 1 Foyer 250 4,862 98 2-6 556 4,799 316 218 218 2 Bedroom 3 168 2,370 48 1-5 593 1,776 167 81 81 3 Bedroom 1 192 5,335 108 2-6 478 4,129 408 188 188 4 Bedroom 2 182 4,016 81 2-5 520 3,115 322 142 142 5 Bath 3 48 889 18 1-4 301 578 72 26 26 6 Bath 2 48 889 18 1-4 301 578 72 26 26 7 Laundry 60 1,150 23 1-4 357 684 95 31 31 8 Bath 1 48 1,131 23 1-4 342 656 95 30 30 9 Bedroom 4 300 5,168 105 2-6 487 4,203 394 191 191 10 Powder 42 64 1 1-4 50 97 0 4 4 11 Living 667 6,639 134 4-6 478 8,248 1,262 375 375 12 Kitchen 374 2,763 56 2-6 494 4,265 403 194 194 13 Breakfast/Dining 310 7,278 147 3-6 472 6,107 501 278 278 Duct Latent 1,377 System 1 total 2,689 42,554 860 39,235 5,484 1,785 1,785 System 1 Main Trunk Size: 18x18 in. Velocity: 793 ft./min Loss per 100 ft.: 0.067 in.wg Cooling System Summary -- - ----"^ -�----�� Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.73 88% / 12% 39,235 5,484 44,719 Actual: 4.00 75% / 25% 36,000 12,000 48,000 -[Equipment Data Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HCD348(A,W)"60 25HCD348(A,W)''60 Indoor Model: CNPV'6024AL' Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: Capacity: 44500 48000 Sensible Capacity: n/a 36,000 Btuh Latent Capacity: n/a 12,000 Btuh AHRI Reference No.: n/a 6009896 Friday, February 21, 2014, 6:22 PM (Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Czerkawski Addition 1739 Live Oak Ln Atlantic Beach,FL Jacksonville,FL 32218 ---- ---- ---- -- - — ---- — --- - - - -- - Page 9 stem 2 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Ht Duct Duct Sens Lat CI Sys No Name SF Btuh CFM Size Vel Btuh Btuh_ CFM CFM ---Zone 1--- 14 Study 154 3,865 78 2-6 496 4,283 473 195 195 15 S WIC 45 735 15 1-4 272 521 55 24 24 16 Pantry 72 1,126 23 1-4 352 675 87 31 31 17 Vestibule 192 1,931 39 1-6 480 2,072 109 94 94 18 Bath 4 54 757 15 1-4 171 328 60 15 15 19 Water Closet 34 518 10 1-4 119 227 44 10 10 20 Master Bath 135 2,965 60 2-4 673 2,580 202 117 117 21 Master Bedroom 437 9,057 183 3-6 543_ 7,032 474 320 320 Duct Latent 668 System 2 total 1,123 20,953 424 17,719 2,172 806 806 System 2 Main Trunk Size: 10x16 in. Velocity: 726 ft./min Loss per 100 ft.: 0.091 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent To TonsSplit _ Btuh Btuh Btu Net Required: 1.66 _—-- 89% / 11% 17,719 — 2,172 19,891 Actual: 2.00 75%/25% 18,000 6,000 24,000 E uipment Data IM Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HCD324(A,W)**30 25HCD324(A,W)**30 Indoor Model: FPMAN*024 Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: Capacity: 22000 24000 Sensible Capacity: n/a 18,000 Btuh Latent Capacity: n/a 6,000 Btuh AHRI Reference No.: n/a 6991454 Friday, February 21, 2014,6:22 PM CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j qy ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000335 Date 6/05/14 Property Address . . . . . . 1739 LIVE OAK LN Application type description RESIDENTIAL ADDITION Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 250000 - ------------ --- -- -- -- -- --- ---- --- ----- - --- --- Application desc ADDITION AND REMODEL - ----------- ---- -- -- -- -- ------ ---- ----- - ------ Owner Contractor - ---- --- -- -- - -- ---------- - - - - ----- -- -- -- -- -- --- - CZERKAWSKI, JOSEPH J BOSCO BUILDING CONTRACTORS 1739 LIVE OAK LANE 2158 MAYPORT RD. ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-0320 --- Structure Information 000 000 ADDITION/REMODEL Construction Type . . . . . TYPE 5-B Occupancy Type . . . . . . RESIDENTIAL Flood Zone . . . . . . . . ZONE X -- --- - - - - ------ -- -- -- -- -- --- --- - ---- ----- --- Permit . . . . . . PLUMBING PERMIT Additional desc REMODEL Sub Contractor COGBURN AND WAKEFIELD PLBG . 00 Permit Fee . . . . 398 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/02/14 ------- ---- - --- ----- -- ---- ------- ---- - ---- Special Notes and Comments Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. I 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS --------- - - - -- - ---- -- -- --------- ----- r�+ ---- ---- -- - -- - PERMIT QtjAA&)N'FI-09LY IN ACCORDANCE WITH A-LL(17'ti�I�A�fil�IrTI:, )IL�31'Vlti THE FLOR&v 97 BUILDING CODES. .0-A '�. ` f is CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 14-00000335 Date 6/05/14 ------------------------------ Other Fees . STATE PLBG DBPR SURCHARGE 5 . 97 ------ ----- Fee summary Charged Paid Credited Due ----- ---------- ---------- . 00 Permit Fee Total 398 . 00 398 . 00 ' 00 . 00 Plan Check Total . 00 . 00 . 00 Other Fee Total 11 . 94 11 . 94 . 00 . 00 Grand Total 409 . 94 409 . 94 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 22 I � � �� JOB ADDRESS: I�Jq LIVE VE O A V_ I �� PERMIT#- NEW OR REPLACEMENT INSTALLATION: Project Value $ TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub = Septic Tank&Pit Clothes Washer Shower �— Dishwasher Shower Pan _ Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances 4 _ Lavatory Water Heater 2.. Other Fixtures ^b.E: y �`'� Water Treating System RE-PIPE: TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank& Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor (Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** ** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority too violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number 790(' Plumbing Company op�_3 (AJA L e ew '01uti 6,` Office Phone Q:7— 1 Z?6 Fax (00 [ Co. Address: (9 SU 6VS• City State rL Zip Z..2 16 License Holder (Print): JA n c!bClP_NA State Certification/Registration # �' �C (�(Z�No Notarized Signature o License Holder /4 iiic MARIA PIMIENTA worn an ubscribed be e me t 20 _• •° Notary Public•state of Florida - _ My Comm.Expires Jan 26,2015 ignature of Notary Publ' •�•'I�OF F��i�' Commission#EE 59060 ��11�1111\ j AbkBosco Building Contractors, Inc. Elm SE 3 20 , Y 1 To: City of Atlantic Beach—Building Department Re: ICYN ENE Foam Insulatiot—Czerkawski Residence at 1739 Live Oak �— Pages: 10 (including cover) Phone: 904.241.0320 Fax: 904.241.0326 Email: info@BoscoCBC.com CBC 1250212 www.BOS000BC-COM Insulation and Specialties 1150 Turnbull Bay Road New Smyrna Beach, FL 32168 386-253-3455 386-423-0422 Fax 386-423-1231 1� i ICYNENE The Icynene Insulation System Healthier, Quieter, More Energy Efficient. —�. ENVIRODESIC Icynene is proud lo be ceni(ied by l:n"'IrodcNic I M and to be a member o(tlie US Grecn Budding Council. BUILDER: BOSCO JOB ADDRESS: 1739 LIVE OAK ICYNENE-C 50 NOBURN IB PAINT INSULATION INSTALLED "R" VALUE INSTALLED INCHES ROOF AREA 20 5.5 UNCONDITIONED FLOOR EXT. FRAME WALLS/GABLES EXT BLOCK WALLS CRAWL SPACE INSULATED BY VERN'S INSULATION AND SPECIALTIES INSTALLED BY ERNESTO FAB I O SALESMAN AARON SOHL BUILDER SIGNATURE 000 0 00o dao 0e 000 vo oe o00 0 00 0 00 000 boo o�o°o eoo°eo oe osb oos �ooe �000so 0000°eo 0 0 0� P� 0000 �o°osod°eoo`b 0000 eooeso.r 00000!=►0000°oho. OSP 0000°° X00000 oee 0000040oe o 000e0 Ooe o0000000o0eP°eMsoo00000o0o°e� 0o00000000Mrb°edo0o0040�0� 4eo�00000° Ov 00 X00 04p oo Op�d Oo�oO Opp 0 Op a0 ,o0p0 CL • e X940 0 000 op �OOOPOo 00 0 Ooo 4°4 0 P4oa OOPP4 �OOOOOt �'0 04o�oe°0000 Oooe� ddPa�aol�a0�11d�eeaas011ddde�ee�00�d dae4se�l��ddese�e�eddepeseelldda¢s�►e�Oe000 Or•,.•••a••n..•r...m. •a w•r.vn.�..v . •a v to. ; e o .0 D;�oo°oo �a0000q�Ja ®s �°o { r 0 0 a .ve o0 OOo°ooe�� ®.=seeo°000 00 0 0 ,� Dise0e0e0000 - "'`., Oo000000�€a �eo°x0000 OoO� � �,`•seeeos 4tp?o�ev0v00 OOoO�► � =moo°0°pOpO�;'° r/ OOoga 3- 0000 OO po i� • =rCD D'soe°o00 0p�, �! • �'0000000 OOoOooao sa �0�°00°000 ' OOOOoo }� ` ®:ooeoe0o00 . 000 5® CDpSsoeoop0 0000:® �svee000 o0Oee0�et%>SOe04e f //00°0osa=� o �'seoeo40 O��pv°Q1 B`��eoo0 000°oo0�z4 ®-woe°o0000 000oo4 , CD m • ^ �seeoo0 °op��=� • p, 0000 ' p0osv: ®:oeooe0 OOOoo9o��� � �.eeoeo00000 • • Bjp000e0000 ®owe°o �oo°o�'=a � �oeeOe00 Op�Oo°o v�a • • �seeee0°000 ; o° :0 • ffi�soe°o00 OOOo od�:� • a000004 �. �� a'4 �v0000 Ooo°oov0CD ®seo0o000 00�°00000 a® � • � • Bp000000000 O0000°��=� • ��0000000 OO oo��® �• 0000 0°Oo°��® p�o 0 00000 �e�o�4 °do°oo p0eeoo�`4 ®i ..0000000 0000�e 1 aQse Q►O•.1 aoa9 11 1 env`�1 1 "o0 SIR NINE VERNON, 9 ae�d►0410e,�°��ee0o0000o0000eoO0O00s0 �seo°O°Oooe.�eee00000000�eepe e e 0oJ ooeeo ooeoor o0o r 0000°0 eso eeo �i►e0000e,�►sme �vevoeeevoo`r00000�`rsoeooeoeoe`rseeee�,� 000 00 00 00 000 0�0 0�0 000 000 0000000 0�0°00 0 0°000 000°000 oeo°o0o•'•►0000 00 00000°Po eoeo°o°° w. o°o°000*'".r'�°ovo°oo 0000°000 eoeo°oo° a d°o 0 00000000 0000 0000° 0000p a 0000° '0°000°po 0 000°a 000°°o° 0pa�►e000° . �°��000��� �oOeOoo9oo �►��oOo 00 , a00000090�00 � 0�090�0900° oaeooeo�°ao o°�Qo� lord 11 eo�°b �de�Fa��16�daa e►����� e�odlaaaa�s�e11109�¢��1��a�a�e�ee�ed�odoe��e9e0o°e0000 000000 [fib%ems �ardiw�d� d°ARVAI o .a ®��oeeep0 OO000° ra �^E�o0e000 0= e�°ooe�}a �'eessespop0 D 0000g'�a ®, . seoe°eo0000 ,�_ �seeeee o = • ®'d400°o0 0°°°000�Fa �;ooeooeo 000°0°o°��a :0 0000 CD 00oovD;oo0o0000 000 ,aC.LCD 00��Fa �=p0000ee ♦ leaeo'�� e0°oOaa 000000o0P 30 ®'�eoo°e000 o0�;a • o°� ;a � � ^ ®•soe°odpe p ° a:0 so 0001 0000°0°0�`/ - • �:=00°00°00 �0 0000 00000o4a,4 ;:;": � . oveop000 ''. 0000�a�a , CID €�000p° �OOO000;� i:ooe°e o0 '. 000000o0v��a © poo0o000000 .. flood , ®,see°opOpO M . , 000°e�oala to • ���e°oep e•. e°a•�sa uveae C • ®;oseOeoO e0�e000 via • � �se0s0o o00e0ooaY� • � v ee00 eeoeoe00 o �'�veoo0°00 000 .a� CD �seep0 • �aaOp0�1 e eva� �;=.vssae �- � �'aseeso0ee00 e000ee0esev� � • • � �oe000 e000°o0�� ®; eeeso0e0 °°o°osas� �; seeese O o 0�,� ®Eo0o0000 OOo oma: eo OOoo v� �0 0000 0p000o0o0�a�� ��00000°00 °°0 ddY® o;g0000ee _ OOOeob�� �;�4op00 Oo°oo_d4; vprev.��.®,�etvvelaa�e��vvv,�,v,,v�v�,4.�•ve�vveaa�.vsa�vvevvva®��000°0 0°°e00po����0io9dvvev�oevOv�4 O-O'��0'fjv�vioaVd�O �6�d��o4 �oe4°e°� o�°eo��0 ��e v4vOvOv Ov�,doe��0�� 000 ooe0 o0e0e0e0000oo°°ae°°00000000°6e�o�0o000000o"°o°p0o000000oo°'c°p0o000000oo°aa°p0000®OOiaoop00 �0°at°►°e0000e°49 0°0°0°o°0�ro°000°o°o�r .4 �°o0000e°b°���0°000°0°ee°��e°e0e°o�J 00°oeoo00�0e00000���0vo0odo�o°000�00000e�0000e ovo�o0`�00000e A' ICYNENE LD-C-5011 - USA PRODI'( 1 SPFC1111CA TION I. PRODI ( T NANIF 4. TECHNICAL DATA Alrernalely,low vapor permeance paint either directly on the foam or as a primer for the ICYNENE l D-\f„ -50 (Based on Core Samples) interior drywall may be used. Thermal Performance Water Absorption Properties Thermal resistance(ASTM C518) Water can be forced into the foam under ICYNENE LD-C-500 is a trademark for light pressure because it is open celled. Water density, open celled, Flexible, 100%water-blown - R/in = R3.7 hr ft2'F/BTU will drain by gravity, given favorable drying polyurethane foam insulation manufactured by potential,and upon drying tying all chemical and Icynene Inc. ICYNENE LD-C-50'spray formula Average insulation contribution in a full fill stud physical properties are fully restored. is a nominal 0.5 lbs/ft' density, free rise material. wall: Acoustical Properties 2. MANUFACTURER 2"x 4" = R13 2"x 6" = R20 Performance in a 2"x 4"wood stud wall: ICYNENE LD-C-501 is made on-site from liquid components manufactured by Icynene Inc. ICYNENE LD-C-500 provides more effective STC Sound Transmission Class-37 Installation and on-site manufacturing is supplied performance than the equivalent R-value of air Hz. Freq. 125 250 S00 1000 2000 4000 by independent Icynene Licensed Dealers. permeable insulation materials. ICYNENE LD-C- ASTM E90 19 30 31 42 38 46 SO"is not subject to loss of R-value due to 3. PRODUCT DESCRIPTION aging,windy conditions,settling,convection or NRC Noise Reduction Coefficient-70 air infiltration;nor will it be prone to traditional Hz. Freq. 125 250 500 1000 2000 4000 ICYNENE LD-C-500,the"classic light density moisture intrusion via air leakage. ASTM C423 .11 .43 .89 .72 .71 .67 formulation of Icynene has been installed in buildings since 1986. Icynene is the pioneer of A FACT SHEET with R-value data is available Burn Characteristics high yield, 100%water-blown polyurethane upon request. foam technology for air-sealing and insulating ICYNENE LD-C-500 is a combustible product buildings. Air Permeance/Air Barrier/Air-Seal and is therefore,consumed by flame,but will not sustain Flame upon removal of the Flame source. ICYNENE LD-C-500 insulates and air-seals in one ICYNENE LD-C-50a fills any shaped cavity, It leaves a charred foam residue. It will not melt step for maximutfi energy conservation while and adheres most construction materials, or drip.ICYNENE LD-C-5000 is subject to all minimizing the environmental impact during creating assemblies with very low air permeance. applicable National/State and County building manufacturing and construction.Significantly Additional interior or exterior air infiltration codes regarding fire prevention. Requirements reducing air leakage means ICYNENE LD-C-500 protection is subject to applicable codes. for Thermal Barrier and Ignition Barrier contributes to a healthier,quieter and more coverings must be met as per the applicable comfortable indoor environment,while reducing Air permeability of core foam: building code having jurisdiction. energy consumption and related greenhouse gas emissions by as much as SO%. ASTM E283 data U.S. Fire Testing ICYNENE LD-C-500 is an effective vapor - 0.009 L/s•ml @ 75 Pa for 3.5" permeable air barrier material that can move Surface Burning Characteristics of with the building to maintain the air barrier Air permeability of a 2"x 6"wood framed wall (ASTM E84) @ 5"Thickness characteristic against energy-robbing air assembly: leakage for the life of the building.Convective Flame Spread <25 air movement inside wall cavities is virtually ASTM E 2178 data eliminated,providing more uniform temperatures Smoke Development <450 throughout the building. - 0.01 L/s•m2 @ 75 Pa for 5.5" *Flame spread rating not intended to reflect The result is superior quality construction,with All buildings insulated and air-sealed with hazards under actual fire conditions. higher comfort levels and lower heating and/or ICYNENE LD{-500 must be designed to include cooling costs. Energy savings will vary depending adequate mechanical ventilation/ outdoor air on building design,location,etc. supply.See ASHRAE Standard 62—Ventilation Electrical wiring for Acceptable Indoor Air Quality. ICYNENE LD-C-500 is applied by spraying liquid ICYNENE LD-C-500 has been evaluated with components onto an open wall,crawlspace, Water Vapor Permeance energized 14/3 and 12/2 residential wiring(max. ceiling surface or cathedral ceiling.There it 1221). It is chemically compatible with typical expands approximately 100:1 in seconds to ICYNENE LD-C-50"is water vapor permeable electrical wiring coverings. prqvide a Flexible foam blanket of millions of and allows moisture to diffuse through the tiny air cells, filling building cavities,cracks insulation and dissipate from the building Note: For any insulation of knob and tube and crevices in the process. It adheres to most envelope. wiring,please reference local electrical construction materials,sealing out air infiltration. code. Water vapor transmission properties Excess material is easily trimmed off, leaving Corrosion a surface ready for drywall or other code- (ASTM E96 Desiccant Method) compliant finish. ICYNENE LD-C-500 did not cause corrosion II perms n 5.5" when evaluated in contact with steel at 1207 and 85% relative humidity conditions. In those situations that warrant a vapor rcrarder, a supplemental layer of polyethylene may be u,ed ICYNENE LD-C-50® - USA Plastic Piping 5. INSTALLATION Based on the 3rd party test evidence submitted, this product was found to comply with: ICYNENE LD-C-504' is compatible in direct ICYNENE LD-C-SO" is installed by a network IRC—2006—2009 contact with CPUC piping systems,as per Paschal of Licensed Dealers, trained in the installation of IBC— 2006 —2009 Engineering Study for the Spray Polyurethane ICYNENE LD-C-50". IECC—2006—2009 Foam Alliance ISPFA) Installation is generally independent of 10. RELATED REFERENCES Bacterial or Fungal Growth and Food Value environmental conditions. It can be installed in hot, humid or freezing conditions Surface All physical properties were determined Independent testing conducted by Texas Tech preparation is generally not necessary. Within through testing by accredited third-party University has confirmed that ICYNENE LD-C- seconds,the foaming process is complete. agencies. Icynene Inc. reserves the right to 50"' is not a source of food for mold;and as change specifications in its effort of continuous an air barrier material, it resists the airborne For information on Health and Safety, refer to improvement. Please confirm that technical data introduction of moisture,nutrients,and mold the Spray Polyurethane Foam Alliance Health literature is current. spores into the building envelope. and Safety guidance documents at www.spraypOlyurethane.com 11. PACKAGING AND STORAGE Environmental/Health/Safety ICYNENE LD-C-SOS"'is 100%water-blown 6. AVAILABILITY Packaging 55 U.S.gallon steel drums and therefore contains no ozone-depleting Check regional Yellow Pages'"' or contact Component 'A' 550 Ib.per drum blowing agents. It is also PBDE-free. It has been Icynene Inc.at 800-758-7325 or our website at thoroughly evaluated for in-situ emissions www.icynene.com for a local Icynene Licensed Base Sear MDI by industry and government experts.VOC Dealer. emissions are below 1/100th of the safe Component'B' 500 Ib.per drum concentration level(TLV)within hours following 7_ WARRANTY the application of ICYNENE LD-C-5041. ICYNENE,LD-C-5000 WHEN INSTALLED PROPERLY IN (Gold Sear)Resin Proper handling and use is required to avoid ACCORDANCE WITH INSTRUCTIONS, exposure to reactive chemicals in their unreacted THE COMPANY WARRANTS THAT THE Storage state. For more information,contact the Spray PROPERTIES OF THE PRODUCT MEET Polyurethane Foam Alliance or the American PRODUCT SPECIFICATIONS AS OUTLINED Component A,Base SealO MDI and Component Chemistry Council. Newly insulated areas have IN THIS PRODUCT SPECIFICATION SHEET. B,ICYNENE LD-C-500 Resin ideally should be been shown to be safe for occupancy 24 hours SAVE AND EXCEPT ANY EXCLUSIONS stored between 60°F and 90°F. after installation is complete. REFERENCED IN THE WARRANTY. ICYNENE LDS-50'1 is CHPS E.Q.2.2/Section Component A,Base Seal",should be protected 01350 Compliant and listed as such in the g. TECHNICAL from freezing. Collaborative for High Performance Schools Icynene Licensed Dealers and Icynene Inc.provide Component B,ICYNENE LD{-500(Gold Sear) (CHPS)Low Emitting Materials(LEM)Table. Resin,can be frozen but must be rot support on both technical and regulatory issues. protected from Under LEED guidelines,products that are CHPS Architectural specifications in CSI 3-Part format overheating 120°F and prolonged storage above E.Q.22/Section 01350 Compliant are considered and design details are available upon request. 100°F. Environmentally Preferable Products. 9, REGULATORY Component B,ICYNENE LD-C-500(Gold Seal") Resin,may separate during storage and should be The reaction used to create ICYNENE LD-C-50" generates Carbon Dioxide to expand the foam. ICYNENE LD-C-SC,has been tested as per the mixed thoroughly prior to use. Carbon Dioxide has a very low Global Warming requirements of the International Code Council Potential(GWP of 1). —Evaluation Service's AC377 Acceptance Criteria 12• INSTALLATION SPECIFICATIONS Qune 2009). Must be installed by Icynene Licensed Dealers. Not intended for exterior use.Not to The following evaluation reports apply to this Refer to the Icynene Installer's Manual for installed within 3"of heat emitting deviceor product: expanded information. where the temperature is in excess of 200"F,as per ASTM C411 or in accordance with applicable codes. ICC ESR-1826 KYNENE 01 Telephone: 905.363.4040 Toll Free: 800.758.7325 Facsimile: 905.363.0102 Website: www.Icynene.com E-mail: inquiry@lcynene.com St-20CI-05- -c!oher 2010 e�eY a nab . COMPLIANCE TESTED by berkeley analytical - VOC Emission Test Certificate Product Name: LD-C-50 Product Sample Information Certificate Information Manufacturer: Icynene Inc Certificate No: 120111-02 Manf.Website: www.icynene.com Certified By: CSI Category&No.: Foamed-In-Place Insulation (07 21 19) Raja S.Tannous,Laboratory Director Date Produced: 12/9/2011 Date: January 11,2012 Reference Standard:California Department of Public Health CDPH/EHLB/Standard Method Version 1.1,2010 (Emission testing method for CA Specification 01350) Acceptance Criteria and Results Demonstrating Compliance of Product Sample to Referenced Standard- Exposure Scet)ariot Individual VOCs of Concernz Formaldehyde Criterion Compliant? Criterion Compliant? School Classroom 5%Chronic REL YES 59.0µg/m3 YES Private Office 534 Chronic REL YES 59.0 Vg/m3 YES 1. Exposure scenarios&product quantities for classroom&office are defined in Tables 4-2—4-5 ICDPH Std.Mtd.V1.1-2010) 2. Maximum allowable concentrations of individual target VOCs are specified in Table 4-1(ibid.) 3. Maximum allowable formaldehyde concentration is 16.5 pg/m3 before Dec.31,20119 9 pg/m3 on Jan 1,2012(ibid.) Potential Applications • CALGreen,CA Code of Regulations Title 24,Part 11,2010,Sections A4.504.3/A5.504.4.8:Thermal Insulation • ANSI/ASHRAE/USGBC/IES Standard 189.1-2009,Section 8.4.1.6:Ceiling&Wall Systems • USGBC LEED for Schools,2009,IEQ Credit 4.6:LEM-Ceiling&Wall Systems • Collaborative for High Performance Schools(CHPS)rating system,2009,Criteria EQ2.2.6:Ceiling&Wall Systems • ANSI/GBI 01-2010 Green Building Assessment Protocol,2010,Table 12.2.1-C:Floors&Other Interior Products i Narrative: Icynene Inc selected a sample representative of its LD-C-50 product and submitted it for testing commencing on 12/14/2011.Berkeley Analytical measured and evaluated the emissions of VOCs from this sample following CDPH/EHLB/Standard Method V1.1-2010.The results of the test are presented in Berkeley Analytical report, 354-009-02A-Janl112. Berkeley Analytical is an independent,third-party laboratory specializing in the analysis of organic chemicals emitted by and contained in building products,finishes,furniture,and consumer products.We are an ISO/IEC 17025 accredited laboratory(IAS,TL-383;all standards used in performing this test are in Berkeley Analytical's scope of accreditation. Disclaimer:This Certificate of Compliance affirms that:1)the product sample was tested according to the referenced standard;2)the measured VOC emissions were evaluated for the defined exposure scenario(s);and 3)the results meet the acceptance criteria of the referenced standard(s) Potential applications of the test and this certificate are suggested.Berkeley Analytical provides this Certificate of Comliliance"as is"without warranty of any kind,either expressed or implied.including but not limited to.the implied war r ant ies of merchantability or fitness for any purpose ©2012 Berkeley Analytical,815 Harbour Way South,Slice 6,McUnond,CA W041 510-236-23251 vdww.berkeleyanalytical corn FC17 I Technical Data Sheet i- F1, ° Plus XD No-Burn i 1392 High Street Suite 211 Product Description: No-Burn Plus XD, developed specifically for spray polyurethane foam (SPF) Wadsworth,nhic 44281 barrier requirements, is an intumescent, latex based coating that acts as a shield protecting the sub- strate from the exposure or propagation of flame by surrounding the treated material with a protective 800-989-B577 char-barrier. No-Burn Plus XD is supplied in 5-gallon(19 L) pails and 55-gallon(208 L)drums ax: 1 Surface Preparation: Prior to the application of No- No-Burn" Plus XD should be mixed with a T oa noburncom Burn' Plus XD, the surface must be free from all depos- SquirrelT" 5 gallon power mixing wand or , wwwn,, , its, including dust, dirt, oil, paint flakes scales, wax. etc equivalent at or between 500-1500 RPM for a for the product to adhere properly to the substrate No- mixing time of 5 minutes per pail Burn Plus XD should be at or above 40°F, prior to and r3, during application The substrate to be treated should 'Shaking No-Burne Plus XD with a paint ^f ' be at or above 40° F, prior to and during application shaker,is NOT sufficient. Moisture content of the substrate must not exceed 19 percent during the application of No-Burn°'Plus XD If No-Burn" Plus XD is mixed more than 24 hours prior to use, mix it again according to Product Preparation: No-Burn Plus XD should never the manufacturer's instructions. No-Burn' be allowed to freeze (32° F), should be stored between Plus XD may be tinted at a maximum rate of 2 40° F and 90° F, and should be kept out of direct oz of tint per gallon. sunlight. If you cannot verify that these conditions have Application: When using an airless sprayer, it is com- been maintained, the product may need to be disposed monly recommended that the spray equipment be capa- of in accordance with the manufacturer's MSDS Use ble of producing a minimum of 3,300 p.s.i. of pressure the product as is; DO NOT DILUTE. Acquire recom- mended mixing and application equipment per the and that it can accommodate the recommended tip orifice sizes of .025 - .031 Removal of filter is recom- manufacturer's Tecbnical Data Sheet and/or product mended from both the spray gun and the pump to allow label Call No-Burn,Inc for more information. for the passage of solid content The most common tip EquipmenUSpraying: Primary method of application is for applying No-Burn Plus XD over spray foam or an airless electronic sprayer Other methods of applica- similar applications is 527,but variations in spray pat- tion include roller or brush. Manufacturers and models tern width and tip size may be required depending on the of airless spray equipment vary. Examples of applicable surface area and the substrate to which the product is equipment follow: being applied G.•co U.PSI u,n_outwt -Mn,'t-V __ Wear a certified respirator and protective eyewear when uv.wax Ins 3300 94- ,?T-43111 tp applying Plus XD. Refer to the MSDS for more uh.4u I1D99 3300_ 1.1wn +pun--.033 n_1p information. Urn Y.x 1 159; 3300 125FM 1 pun•.037 in.tip ICC-ES Report Tilvn Max PSI ... M..Output Ilex Tip Slue #1526 _ 6.0 Yigcr 3300 ,ppm ,pM1-.o3Z h.uP • ICC-ES Report For more information,please contact: 11401+1 3300 ,2up+n 1.9+�-_03.11._p #I172 " : Corporate Office 1W V,"A 3300 1.3%— ;1 pun-030 h • ICC-ES Report 800-989-8577a ' Remor.l of iia s rrcor+e+rv0ed 60.v herr the yry pun and iht Dw1D to Now M Mt #2600 p«.,pe.1.wD lwMenl--------------- • ICC-ES Report 'U—ti-t—recomm.nea e•x hove•.0 of So h #2940 Ax,.,.w.y<1 nove..,r, 6" K.,�ae4e,of 32'o,1.,", . ICC ES Report #3034 • Coverage rate Mixing; No-Burn" Plus XD has a high solids content that 90-300 square feet per must be suspended evenly throughout the mixing roc- gallon (reference an equal a 1s„ ess, and it must be thoroughly mixed before use in relevant third party test performed by tha'n- n laborites g y reports) Has when proparty applied by a certified accordance with the manufacturer's recommendations No-Bum*applicator.Warranty coverage Is limited solely to the cost of product purchased hereunder and specifically excludes incidental expenses and conse- quential damages.All implied warranties from No-Bum Incorporated are ex- cluded. There may be situations and materials for which No-Burn` products will not prevent a fire from igniting or retard the progress of a fire. No-Burne is a registered trademark of No-Burn,Incorporated Technical Data Sheet No-Burn° Plus XD 1392 High Suite 211 Ohio }' No-Burne Plus XD should be at or above 40° F, prior to and during application. The substrate to be treatedPhone:800-989-8577 should be at or above 40° F, prior to and during applica- 330-336-5890 tion Moisture content of the substrate must not exceed Email:info_anoburncam 19 percent during the application of No-Burn" Plus XD The surface must be free from all deposits,including dust. www.noburn.com dirt, oil, paint flakes scales, wax, etc for the product to adhere properly to the substrate Refer to appropriate mixing instructions utilizing the recommended application equipment. Overcoats need to be water-based with a pH of 7-8 Prior to the use of any overcoat, it is recom- mended that an inconspicuous area be tested for com- patibility before widespread application Compatibility may be noted as the overall satisfactory condition of the substrate once No-Burno'Plus XD and an overcoat have been applied Dry Time: Typically between 60 to 90 minutes, depend- ing on the ambient temperature and relative humidity conditions. Allow No-Burn Plus XD to dry completely between coats, if more than one coat is required, or be- fore the addition of a water-based top coat. Clean-up & Storage. Soap and water. Store at or be- tween 40° F and 90° F, and keep out of direct sunlight. Do NOT allow product to freeze Dispose of remaining product per manufacturer's MSDS To recycle pails visit, htty://www.wbdg.org/tools/cwm.php Far r No-Burn,Inc.'s Corporate Office Typical Physical Properties 800-989-8577* ob Plus XD: Calor. Opaque/White or as specified VK 18 g/E EPA Method 24 Specific Gravity 115 No-Bum'lncorporatsd. Boiling point 212f No-Bum`� formula will to the Sarno speclflca freezing Point 321' and will perforin equa %Volatile by Volume 45% performed by the Indepen rtes when properly applied flash Point: N/Av No-Bum*applicator.Warranttycoverage Glean up Soap and water Is limited solely to the cost of product purchased hereunder and specifically Cure time: 24 hours excludes incidental expenses and conse- quential damages.All implied warranties from No-Bum* Incorporated are ex- Drums 55 gallons.GD51bs cluded. There may be situations and Pails 5 gallons 55 lbs materials for which No-Burn products g will not prevent a fire from igniting or retard the progress of a fire. No-Burn is a registered trademark of No-Burn,Incorporated Insulation and Specialties 1150 Turnbull Bay Road New Smyrna Beach, FL 32168 386-253-3455 386-423-0422 Fax 386-423-1231 1r ICYNENE The Icynene Insulation System Healthier, Quieter, More Energy Efficient. ENVIRODESIC- - -- Icynene is proud to be certified by Envirodesic TM and to be a member of the US.Green Building Council. BUILDER: BOSCO JOB ADDRESS: 1739 LIVE OAK ICYNENE-C-50 NOBURN IB PAINT INSULATION INSTALLED "R" VALUE INSTALLED INCHES ROOF AREA 20 5.5 UNCONDITIONED FLOOR EXT. FRAME WALLS/GABLES EXT BLOCK WALLS CRAWL SPACE INSULATED BY VERN'S INSULATION AND SPECIALTIES INSTALLED BY ERNESTO FABIO SALESMAN AARON SOHL BUILDER SIGNATURE