1600 Selva Marina Drive 14-00000421 (Fire sprinkler) CITY OF ATLANTIC BEACH s1 s J 800 SEMINOLE ROAD J77 r� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Appl on Number 14-00000421 Date 4/07/14 RE number 169399-0000 NCR OLD ACCOUNT NUMBERS . . . AB04050 Application type description MECHANICAL FIRE PERMIT Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 Owner Contractor _ ------------------------ ------------------ SELVA MARINA COUNTRY CLUB LIFE SAFETY DESIGNS INC 1600 SELVA MARINA DR 3038 LENOX AVE ATLANTIC BEACH FL 322335616 JACKSONVILLE FL 32254 (904) 388-1700 ----------------------------------------- Permit . . . . . . MECHANICAL FIRE SPRINKLER Additional desc . . . 00 Permit Fee . . . . 359 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 19000 Expiration Date . . 4/07/14 Qty Unit Charge Per Extension BASE FEE 55 . 00 19 . 00 8 . 0000 THOU M FIRE ALARM 152 . 00 19 . 00 8 . 0000 THOU M MECH FEE BY VALUATION 152 . 00 --------------------- ----------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 5 . 39 STATE MECH DBPR SURCHARGE 5 . 39 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- --- Permit Fee Total 359 . 00 359 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 10 . 78 10 . 78 . 00 . 00 Grand Total 369 . 78 369 . 78 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATF CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL _3 133 Ph(904) 247-5826 Fax (904) 247-`-' -;_) JOB ADDRESS: 1600 SELVA MARINA DR. JACKSONVILLE,FLORIDr> PERMIT#_13-00003848_ JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS PHASE VAL UE OF WORK$ NEW SERVICE ❑ Overhead ❑ Underground ❑1 Underground up Pole -]Residential(Main) Service JO-100 amps J 101-150amps J 151-200amps amps # of Meters J Commercial(Main) Service JO-100 amps J 101-150amps J 151-200amps J amps JCT Service amps Conductor Type Size J Multi-Family(Main) Service J0-100 amps J 101-150amps _1151-200amps -i _amps # of Unit Meters _]Temporary Pole '_l amps SERVICE UPGRADE J amps J CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) J 100 amps J 150amps J200amps -1—amps JCT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kms' Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS • 4STEM �*- JTransformers KVA JMotors hp RE ALA (Requires is of plans' VALUE OF WORK S19,000.00 Qty ps F� ._---- J Replace Burnt/Damaged Meter Can -]Safety Inspection J Panel Change ---I OH to UG -]Other:—Install Low Voltage Fire Alarm System Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of Phone Number 1 construction. �y X I' 4 14d Property Owners Name Cali Office Phone (904) 388-1700_Fax(904) 388-1718_ Electrical Company Life Safety Designs Co. Address: 3038 Lenox Ave. City Jacksonville State Florida Zip 32254_ License Holder (Print): Darryl A. Elksnis_� to Certificatio�.'Registration# EF-0000878 �' lder STEPNANI GILLESPIE 20 F Notary Public-Stat^01 Florida Sworn and s scribed before `�t'dayMy Comm.Expires Ue ?1.2016Commission#f EE 63Z347 sondearnrou�nNatio�a ,�yAssn. Signature of Notary Publ _ w W f/f W Q d z V r� w o � Z N z Z N 1 O 0 (D C� m Q cr "I W 5G C) Plan rev--nv and issuing of per.mit docs m am relieve contractor of complying with all °D m a m m State Fire Codes z o LL ui a Of ¢ Q a 0 U-) Q C V REVIEWED Jacks©nyWe Fire PravantiOn Ir; Z 2, 614 Q NO EXCEPTIONS Q EXCEPTIONS AS NOTED Z SHEET# 0 U ttt Z WIRING LEGEND 010 0 � SHIELDED, JACKETID W KETED FPLP CABLE - ADDRESSABLE LOOP W W - DED, JACFPLP CABLE - ANNUNCIATOR DATA & 24VDC POWER a 7 DED, JACKETED FPLP CABLE - REMOTE MIC DATALn REMOTE MIC 24VDC POWER 0 W m HORN/STROBE CIRCUIT #1 (SO 6 FACP U. -- THORN/STROBE CIRCUIT #2 (S2) Q FACE `� City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned b the Build'ng Department.) 800 Seminole Road r O Z r) Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904) 247-5845 �} ��p j•1 E-mail: building-dept@coab.us Date routed: / zd City web-site: http://www.coab.us APPLICATION REVIEW AND TRACK"ING FORM Property Address: o� ���1/Q.,��J'►'�/1 Department review required Yes No z uilding _ Applicant: / �j,s Planning &Zoning /� tt /J14-i Tree Administrator Project: �/� G J7l!� rj�� Public Works Public Utilities Public Satety ire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denier. (Circle one.) Comments: BUILDING PLANNING &ZONING il / Reviewed by. A Date: TREE ADMIN. Second Review: []Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIR lSERVIC Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 Vii+ 1, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned b the Build' g Department.) 800 Seminole Road O Z Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 Q / E-mail: building-dept@coab.us Date routed: 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �l o �G! I�Q.,� Department review required Yes No / uildin Applicant: z 1 / �js Planning 8,Zoning Tree Administrator E Project: /e /J m .� 6 Public Works Public Utilities Public Safety ire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: TrApproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNIN ONING Reviewed by: OE 4 Date: t� TREE ADMIN. Second Review: ❑Approved as revised. ❑Deni PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 N ; ti ELECTRICAL PERMIT APPLICATION FILE COPY CITY OF ATLANTIC BEACH a 800 Seminole Rd, Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 1600 SELVA MARINA DR. JACKSONVILLE,FLORIDA PERMIT#_13-00003848_ JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS PHASE VALUE OF WORK$ NEW SERVICE ❑ Overhead ❑ Underground ❑J Underground up Pole -]Residential(Main) Service -]0-100 amps J 101-150amps -]151-200amps -] amps # of Meters -]Commercial(Main) Service 10-100 amps J 101-150amps -]151-200amps amps -]CT Service amps Conductor Type Size Multi-Family(Main) Service 10-100 amps J 101-150amps 151-200amps amps #of Unit Meters —]Temporary Pole J amps SERVICE UPGRADE amps -] CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) -]100 amps J 150amps J200amps -] amps -]CT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS _� o,,t 4mnkP no*�^*^�� n*., -]Transformers KVA -]Motors hp 1 I ALA STEM (Requires is of plans' Qty volts/amps VALUE OF WORKS 19,000.00 R.... -]Replace Burnt/Damaged Meter Can _]Safety Inspection -]Panel Change OH to UG -]Other:—Install Low Voltage Fire Alarm System Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. l hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. X 114 ' 4 Kd Property Owners Name Phone Number 7 Electrical Company Life Safety Designs Office Phone (904) 388-1700_Fax(904) 388-1718_ Co. Address: 3038 Lenox Ave. City Jacksonville State Florida Zip 32254_ License Holder (Print): Darryl A. Elksnis to Certification/Registration# EF-0000878 ono At is wo J [der STEPHAWIrGILLESPIE t Stall,!of Florida K1 day 20 Notary Public-Stall,! Sworn and scribed before •;My Comm.Expires Dec 2 t.2016 Commission At EE 02347 Signature of Notary Publ �'••,,,,,,•`` Bonded Through Nation, ,,y Assn. k� LIFESSAFET!J D E S 1 G N S W W W . L I FES A FETYO ES I G N S - 0 O M SUBMITTAL DATA FOR ATLANTIC BEACH COUNTRY CLUB 1600 SELVA MARINA DR. FILE C JACKSONVILLE, FLORIDA JOB No. 2140500 FEBRUARY 26,2014 ELECTRICAL CONTRACTOR:AMERICAN ELECTRIC fILE COPY TABLE OF CONTENTS: I FIRE ALARM MANUFACTURERS CATALOG DATA DESCRIPTION MANUFACTURER PART# PAGE# a)FIRE ALARM CONTROL PANEL NOTIFIER NFW2-100 1-6 b)VOICE EVACUATION PANEL NOTIFIER NFC-50/100 7-14 c)VOICE EVACUATION REMOTE MIC NOTIFIER NFC-RM 15-18 d)REMOTE AUXILIARY POWER SUPPLY NOTIFIER FCPS-2458 19-20 e)REMOTE ANNUNCIATOR PANEL NOTIFIER N-ANN-80-W 21-22 I)MANUAL PULL STATION NOTIFIER NOT-BG12LX 23-24 g)PHOTOELECTRIC SMOKE DETECTOR NOTIFIER NP-100 25-26 h)DUCT SMOKE DETECTOR NOTIFIER DNR 27-28 j)ADDRESSABLE CONTROL MODULE NOTIFIER NC-100 29-30 k)ADDRESSABLE RELAY MODULE NOTIFIER NC-100R 31-32 m)ADDRESSABLE MONITOR MODULE NOTIFIER NMM-100 33-36 n)SPEAKER STROBE SYSTEM SENSOR SPSW 37-40 p)STROBE SYSTEM SENSOR SW 41-44 q)LOW VOLTAGE SURGE SUPPRESSOR DITEK DTK-2MHLP 45 r)120VAC SURGE SUPPRESSOR DITEK DTK-120 SR 46 II BATTERY & SIGNAL CIRCUIT CALCULATION R C ♦ E a)BATTERY CALCULATION(NFW2-100)M' Fire Praventi�Div So E D 47-49 vil:z: b)SIGNAL CIRCUCALCULATION(NFW2-100) Jackson c)BATTERY CALCULATION of permit docs MA 2 .5 2014 51 plan rRdw'wior of OMP1Yiug WithaU 52-54 d)BATTERY CAj.�{J� 11TT `� e)SIGNAL CIRCuuur CALcutL rfi&R �P 94 Codes 13 NO EXCEPTIONS 55 E3 EXCEPTIONS AS NOTED SHEET# 3038 LENOX AVE. • Jacksonville • Florida 32254 • 904-388-1700 • Fax 904-388-17 9 FL — EF000878 FL CONTRACTOR I — 13235500011993 DN-60602:A1 FireWarden-100-2(E) Rev 3 (1� NOTIFIER ® Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3 (NFW2-100)with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT(Digital Alarm Communicator/Transmitter)all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. --- The's quick-remove chassis protects the electronics during con- struction. on struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS,and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso Remote site or local USB port upload/download, using PS- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with WindowsO XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software . Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, . Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80,N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged . ANN-BUS for connection to following optional modules(cannot directly into the printed circuit board.This permits easy typing of be used if ACS annunciators are used): address labels and other programming information. –N-ANN-80(-W)Remote LCD Annunciator Version 5.0 firmware supports the following: Primary and Sec- _N-ANN-1/0 LED Driver ondary ANN-bus devices,NP-A100,USB port,NAC circuit diag nostics,a new report has been added to the walk-test that lists –N ANN S/PG Printer Module untested devices, new device types added: audio telephone –N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- –N-ANN-LED Annunciator Module table Drill(non-latching). –N-ANN-BLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 –ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the ACS&Terminal-mode Annunciators: Internet saving the monthly cost of two dedicated business tele phone lines. Although not required, the secondary telephone –ACS Annunciators:Up to 32 Legacy ACM Series annuif line may be retained providing backup communication over the tors (ACM 16AT or ACM 32 series). Cannot be useedd if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term ',Fire Warden-100-2" –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the Fire Warden-100-2 and annunciators. the Fire Warden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-1OOE as well. cuit board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 2140500 Page 1 of 55 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point . Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: ��� NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 it.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E: Same as NFW2-100,except with 240 VAC opera- tion. NOTIFICATION APPLIANCE CIRCUITS(NAGS): 4XTM Reverse Polarity Transmitter Module: Provides super- • Four onboard NACs with additional NAC capability using out- vised output for local energy municipal box transmitter, alarm, put control modules (NC-100). The four Class B NACs can and trouble. be converted to four Class A NACs with optional ZNAC-92 ZNAC-92: Optional converter module which converts four (4) converter module. Style Y (Class B) NAC circuits to four(4) Style Z(Class A)cir- • Silence Inhibit and Auto Silence timer options. cuits. • Continuous, March Time, Temporal or California code for PS Tools: Programming software for WindowsO-based PC main circuit board NACs with two-stage capability. computer(cable not included),available on www.firelite.com. • Selectable strobe synchronization per NAC. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. • 2.5 amps maximum per each NAC circuit. TR-CE-B:Optional trim Ring for semi-flush mounting. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram(learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120:Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than • 99 software zones. 18AH. • Continuous fire protection during online programming at the BAT Series:Batteries,see data sheet DN-6933. front panel. • Program Check automatically catches common errors no XRM-246(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows&based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable; required for printer or for local upload/download program- able on www.magni-fire.com).Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT 2/2UD, IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- net internet connection. Requires compatible Teldat LED INDICATORS VisorALARM Central Station Receiver. Can use DHCP or static • AC Power(green) IP.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 2140500 Page 2 of 55 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-10OR: Addressable relay module containing two isolated N-ANN-RLED: Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SM8500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT-BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-13 for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SM8500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connection for a serial or parallel printer. (See DN-7103.) on a CHS-6 chassis in a B13-25. N-ANN-1/0: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R:Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional).Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a 1313-25. of providing up to 99 software zones of annunciation.Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-ISO(DN-6994),NP-100 series annunciators. (DN-6995), NI-100(DN-6996), NH-100 series(DN-6997), ND-100 custom graphic series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator: 80-char- NDM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- While shielded wire is not required, it is recommended that all 0524),LDM Series(DN-0551),FDU-80(DN-6820). SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-10OT:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-10OR: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100: Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-10OH: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-10OR separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-10OP: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 2140500 Page 3 of 55 FireWarden-100-2 Rev 3 ♦------- ------------------------ Fire Alarm Control/ i ANN-BUS Communicator ' or � t. ANN-BUS DEVICES EIA-485 10 N-ANN-80,N-ANN-LED, ? in ACS mode N-ANN-S/PG,N-ANN-1/0 (two wires) SMOKE DETECTORS NP-100,NP-100T, 24 VDC } ` NI-100,NP-A100 Optional � REVERSE f...__..' HEAT DETECTORS POLARITY/ NH-100,NH-100R,NH-100H ■ ■ CITY BOX ■ ■ OUTPUT ■ 1111111 � (4XTM) ■ �D O ANNUNCIATORS ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS (optional,order ACM-8R) ND-100,ND-100R,DNR NOTE:System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used ° simultaneously. NACs(Notification Appliance Circuits) BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-10OR INTERFACE (PIM-24)built into the motherboard ADDRESSABLE MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the ®� printer OR the FDU-80. They cannot be used simultaneously. EIA-485 24 VDC INTERFACE (four wires) MINI-MONITOR NMM-100P Q0OC10 FDU-80 3 Up to 6,000 ft.(1825.8 m) 8 between each FDU-80 in the EIA-485 loop,and between PULL STATION each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 2140500 Page 4 of 55 DN-60602:A1•12/07/2010—Page 5 of 6 2140500 Page 5 of 55 SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring(TR-CE- • Intelligent Signalling Line Circuits.........................................1 B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Addressable device capacity............................................198 Shipping Specifications • Programmable software zones...........................................99 • ACS Annunciators..............................................................32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices................................................................16 Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32—120°F and at a relative humidity 93%t 2%RH(non- amps.FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C t 2°C (90°F t 3°F). However,the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y (Class B) for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B)or with an optional ZNAC-92 module converts to four —LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z(Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 —AUXILIARY (Automatic, Manual and Waterflow) (requires UL listed)for Style Y(Class B) NAC.Refer to panel documenta- tion and Notifier Device Compatibility Document for listed com patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 alarm,trouble and supervisory relays may be connected to VAC(resistive).Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettable Power (24 VDC Nomi- —PROPRIETARY(Automatic, Manual, Waterflow and Sprin- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- —CENTRAL STATION (Automatic, Manual, Waterflow and put.Power-limited. Sprinkler Supervisory). Special Application Resettable Power (24 VDC nominal). —OT, PSDN(Other Technologies,Packet-switched Data Net- Jumper selectable(JP6)for conversion to non-resettable power. work) Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. s Remote Sync Output: Remote power supply synchronization Agency Listin g and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel.In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed: S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared . CSFM:7165-0028:0235 phone lines or PBX(digital)type phone line extensions. • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and ExcederTA° is a trademark of Cooper Notification. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MgMBlpe` � All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 2140500 Page 6 of 55 DN-60772:A1 First Command NOTIFIER NFC-50/100(E) 0 by Honeywell Voice Evacuation & Emergency Communications System 'i General Notifier's First Command NFC-50/100 and NFC-50/100E are multipurpose emergency voice evacuation panels for fire appli- cations,mass notification applications,or both.The First Com- mand delivers 50 or 100 watts of audio power for distribution to - o up to eight speaker circuits (i.e. zones). The NFC-50/100(E) ; comes standard with a single speaker circuit and a built-in 50 ; watt,25V amplifier.A secondary 50 watt amplifier(NFC-BDA- 25/70V) can be added for single speaker circuit backup or to o increase system capacity to two speaker circuits and an addi- tional 50 watts of audio power. An optional NFC-CE6 module added to the NFC-50/100(E)will upgrade the system to a max- imum of eight speaker circuit outputs. All speaker output cir- cuits can be wired in either Style Y(Class B)or Style Z(Class - A) configuration. The NFC-50/100(E) has fourteen field pro- grammable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully supervised Notification Appliance Circuit (NAC) with 2.0 amps of synchronized NAC power. The NFC-50/100(E) includes three built-in Form-C relay contacts, (AC power,trou- ble and MNS active)a NAC follower and 500mA special appli cation power. A built-in power supply delivers operational power and on board battery charger supports charging up to 26AH batteries(NFC cabinet holds up to 18AH batteries). For fire protection applications, the NFC-50/100(E) is an adjunct (slave) to most UL listed FACPs or as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification,the NFC-50/100(E)can be Nptcm.APPLICATIONS activated by the NFW2-100(Rev 3) and NFW-50 when con- nected to the ACS/ANN serial communication bus. Activation of the NFC-50/100(E) via other FACP's uses the eight on • Schools • Nursing Homes • Factories board Command Input Circuits(CMD's).Two of the eight CMD . Theaters • Military facilities • Restaurants circuits (CMD 1 & CMD 2) can be individually field pro grammed for activation by an FACP Notification Appliance Auditoriums Places of Worship Office Buildings Cir- cuit reverse polarity and all eight can be activated by a contact closure. In addition,the NFC-50/100(E)can be activated from Features a building's Private Branch Exchange (PBX) with the integral night ring feature. • UL Listed to UL 2572 Communication (Control Units Mass All NFC-50/100(E) programming is done by using a simple, Notification Systems)and UL 864(emergency voice evacu- built-in programming utility accessed from any laptop. For ation for fire). added flexibility, the NFC-50/100(E) supports both 25V and • Modular design for system flexibility and easy expansion. 70V speaker output operation. By adding a 70V transformer • Removable terminal blocks. conversion module (NFC-XRM-70V) or an additional 70 volt . 50 watts of 25V audio power (expandable to 100 watts) secondary amplifier (NFC-BDA-25/70V) the system supports RMS. 70 volt speaker devices. • 2 amp Notification Appliance Circuit (NAC) output, sync The NFC-50/100(E) can expand in order to accommodate generator,or follower for System Sensor,Wheelock or Gen- larger or more complex installations.To add more control and tex protocols. increase system capacity,any combination of up to eight exter- . Optional 70V transformer available for the primary amplifier. nal remote consoles(including the NFC-LOC, NFC-RPU, and (Note that speaker wiring continues to be supervised in NFC-RM) and up to eight distributed audio amplifiers (includ- standby, alarm and when background music is playing with ing the NFC-50DA(E) and NFC-125-DA(E) can be connected this optional transformer installed). on the external data bus and audio riser data bus to create a fully integrated command center. A fully loaded system sup— ports up to 1100 watts of total audio power and up to 24 —CMD1 and CMD2 are field selectable to be activated from speaker circuit outputs. 12 or 24 VDC Notification Appliance Circuits (reverse polarity)or contact closures. —CMD3-CMD8 are activated by contact closures. • Speaker Circuits. —Single Style Y(Class B)or Style Z(Class A)speaker Cir- cu it. DN-60772:A1•7/15/13—Page 1 of 6 2140500 Page 7 of 55 —Two Style Y (Class B) or Style Z (Class A) speaker cir- Optional Internal Expansion Modules cuits (with optional NFC-BDA-25l7OV Audio Amplifier installed). NFC-CE6: Circuit Expander Module provides connections for up to six Style Z (Class A) or Style Y (Class B) speaker cir- , —Eight Style Y (Class B) or Style Z(Class A) speaker cir- cuits.Circuits are configured through the web-based program- cuits (with optional NFC-BDA-25170V and NFC-CE6 ming utility. installed). • NFC-5lled). E)can be controlled by an FACP via the ANN/ NFC-BDA-25V:25V,50 watt audio amplifier module.Adding a ACS(EIA0/1-485)link b the NFWed by (Rev 3). second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. • Integral supervised microphone. Microphone time-out feature which reverts back to pre- NFC-BDA-70V:speaker 70V,circuit 50 watt audio amplifier module.Adding a • recorded message if emergency page exceeds the pro- second speaker circuit increases the total NFC-50/100 a0 power output to 100 watts or can also be used as a backup amplifier. grammed time. • 14 recorded messages. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-50/100(E) primary amplifier to a 70V output. • Field-selectable message and custom message recording This transformer mounts directly to the NFC-50/100(E) main capability using the local microphone, a USB port, or an control board by two metal brackets. external audio input. • External Audio Input can be used for background music. • Up to 60 second message duration for all messages. • Integral tone generators field selectable for multiple tone types. • Powered by integral AC power supply or batteries during AC fail. • Programmable delay of immediate, 2 hours or 6 hours reporting of AC Loss. • Piezo sounder for local trouble. • 100 event history log. • Three Form-C relays: —AC Power Loss Relay-TB1. —System Trouble Relay-TB2. —MNS Active-TB3. • 500mA (0.5A) Special Application (auxiliary power) output for addressable modules when interfaced with compatible addressable FACPs and End-of-Line power supervision relays. • System Status LEDs (refer to "Controls and Indicators" on product manual LS1 0001-OOONF-E). • Integral Dress Panel. • Optional TR-CE-B semi-flush trim ring. • Any combination of up to eight (8) external remote con- soles: —Optional NFC-RM Remote Microphone (includes cabi- net).See DN-60778. —Optional NFC-RPU Remote Page Unit(includes cabinet). See DN-60775. —Optional NFC-LOC Local operator console(includes cab- inet).See DN-60777. • Any combination of up to eight(8)distributed audio amplifi- ers: —Optional NFC-50DA(E) distributed amplifier, 50 watts. See DN-60776. —Optional NFC-125DA(E) distributed amplifier, 125 watts. See DN-60776. Page 2 of 8—DN-60772:A1•7/15/13 2140500 Page 8 of 55 horns/strobes a � o __ 0 Internal options NFC-BDA-25/70V optional amplifier NAC Circuit Speaker Circuits 90" NFC CE6 circuit expander T619 TB20&T621 0 0 0 0 0 p O O I Co. al) _ C19: U � NFC FFT firefighter telephone ED. ©i CIO ! ®i Oi J • 0 0 o O remote NFC-LOC NFC-RPU NFC-RM consoles local operator console remote paging unit remote microphone --- 0 0 TB4 • o TB12 i eA& al*'UTfery- TB22 charger-J7 distributed audio NFC-50DA 50W NFC-125DA 125W remote amplifier remote amplifier r a CHG-120 charger CHG-75 charger NFC-50/100(E) FirstCommand (Possible Configurations) DN-60772 Al•7/15/13—Page 3 of 8 2140500 Page 9 of 55 LED Status Indicators (visible with door closed) FIRE SY6TEM ALL ACMEe� IRESYSTE • u« �I OVERRIDE COMTR« LOC/RPU/RM 1-8 Active Fire System Active(green) (green) SPEAKER 1 o I SPEAKER 13o I ZONE 13 IM MNS Control(green) Main Console Fault(yellow) ZONE 1 SPEAKER M I SPEAKER 14o I ZONE 14 System Control(green) AC Power(green) ZONE 2 SPEAKER ONp ZONE 15 NIS OK TO PAGE g o I SPEAKER 15o I System in Use(green) Ground Fault(yellow) ZONE 3 SPEAKER MICROPHONE 4 o I® SEE 16 I ZONE t8 TROUBLE Speaker Zone 1-24 Active 10 EER ° SPEAKER (green) Charger Fault(yellow) SPEAKER ZONE 17 5 O I 170 I O I MF S6AGE 1 ® ZONES SPEAKER Speaker Zone 1-24 Fault Battery Fault(yellow) 6 o I AZO E 6R 18° I ZONE t8 ®° I MESSAGE (yellow) SPEAKER SPEAKER T° I I ZONE,9 ®° I MESSAGE ZONE 7 19° OK to Page(green) Data Bus Fault(yellow) SPEAKER SPEAKER 8 c I ZONE 6 20o I ZONE 20 I MESSAGE4 Microphone Trouble(yellow) NAC Fault(yellow) SPEAKER SPEAKER 9 o I ZONE 9 21° I ZONE21 I MCSSAGE6 Message 1-8 Active(red) NAC Active(green) 10o I ZONE io 22° I ZONE 2 I MESSAGES Message 1-8 Fault(yellow) System Trouble(yellow) SPEAKER 110 I ZONE I 23° I ZONNE23 o I MESSAGE? Remote Amplifier 1-8 Fault Audio Riser Fault(yellow) SPEAKER 12o I ZO E 12 24° I zoNSPEAKER I MESSAGEe (Yellow) LOC/RPU/RM 1-8 Fault _�— (yellow) �DIAOEIOSTIC ® TROUBLE SILENCE co.xolE K•r*Es+ REMOTE AMPS AC POM R MAN CONSOLE LED Indicators (visible with door and D DIST AMP L-Ta GROENDIwII LOCI dress panel open) > DIST ANIP2 >^•D CHARGER EAUL I ° LOC2 D DIST AMP] BA FIERY EAULI ° 1 RPU 1 • Speaker Volume Control Fault(yellow). > DIST AIAP4 1a> DA IA BUS D > RPU2 • Option Card Fault(yellow). }> DIST AMPS A NACfAull D> RPU3 . Amplifier Over Current Fault(yellow). > DIST AMP 6 ' WIC AC INE D } RM 1 n DIST AMP 7 D sYsTEM IRDUBLE D )0' RM 2 AuoaaaEarAuu p)♦ Product Line Information > D15T AMP D RM3 NFC-50/100:(Primary Operating Console)50 Watt,25V single speaker zone emergency voice evacuation system, integral Control and Indicators microphone, built in tone generator and 14 recordable mes- sages. PUSH BUTTON CONTROLS NFC-50/100E: Export version (Primary Operating Console)50 Watt, 25V single speaker zone emergency voice evacuation system, integral microphone, built in tone generator and 14 • All Call • Message Select 1-14 recordable messages. (240 VAC, 50Hz). • MNS Control • Diagnostic Select NFC-CE6: Speaker Circuit/Zone Expander Module. • System Control • Trouble Silence NFC-BDA-25V: 25V, 50 watt audio amplifier module. Adding a • Speaker Select 1-24 • Console Lamp Test second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. J NFC-BDA-70V:70V, 50 watt audio amplifier module. Adding a second speaker circuit increases the total NFC-50/100 power output to 100 watts or can also be used as a backup amplifier. NFC-XRM-70V: 70V Transformer Conversion Module. Con- verts the NFC-50/100(E) primary amplifier to a 70V output. This transformer mounts directly to the NFC-50/100(E) main control board by two metal brackets. NFC-LOC: Local Operator Console(Complete user interface), Please refer to the data sheet DN-60777 for more information. NFC-RPU: Remote Page Unit Hand held microphone, 14 mes- sage buttons. Please refer to the data sheet DN-60775 for more information. NFC-RM: Remote Microphone only. Please refer to the data sheet DN-60778 for more information. NFC-50DA: Distributed (Remote) Audio Amplifier, 50 watts. Please refer to the data sheet DN-60776 for more information. NFC-50DAE: Export version. Distributed (Remote) Audio Amplifier, 50 watts. (240 VAC, 50Hz). Please refer to the data sheet DN-60776 for more information. Page 4 of 8—DN-60772 Al•7/15/13 2140500 Page 10 of 55 NFC-125DA: Distributed (Remote)Audio Amplifier, 125 watts. • Minimum Battery size:12 Amp Hour. Please refer to the data sheet DN-60776 for more information. AC LOSS RELAY CONTACT RATING(TB3) NFC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts.(240 VAC,50Hz).Please refer to the data 2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 VAC(resistive). sheet DN-60776 for more information. FORM C-TROUBLE RELAY CONTACT RATING(TB2) NFC-CE4: Distributed Audio Speaker Circuit/Zone expander . 2,0 amps @ 30 VDC(resistive),0.5 amp @ 30 VAC(resistive). module. NFC-FFT: Fire Fighter Telephone System. Please refer to the MNS ACTIVE RELAY CONTACT RATING(TB1) data sheet DN-60779 for more information. • 2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 VAC(resistive). N-FPJ:Remote Phone Jack. NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING FHS-F: Fire Fighters Remote Handset. (TB 19) FHSC-R:Fire Fighters Handset Cabinet Recessed. • One(1)Style Y(Class B)or Style Z(Class A)circuit. FHSC-S: Fire Fighters Handset Cabinet Surface Mount • Power-limited circuitry,(Class 2)supervised. TR-CE-B:Optional Trim Ring. • Nominal operating voltage:24 VDC. THUMBLTCH:Optional Thumb Latch.(Non UL-Listed). . Maximum signaling current for special application power: 2.OA. CHG-75:25 to 75 ampere-hours(AH)External Battery Charger. . Maximum signaling current for regulated power:200mA. CHG-120:25-120 ampere-hours(AH)External Battery Charger. • Maximum wiring impedance: 192 ECC-MICROPHONE: Replacement Microphone only. • Current limit:fuse-less,electronic,power-limited. BAT-1270: Battery,l2 volt,7.0 AH(Two required). • End-Of-Line Resistor:4.7 K92,1/2 watt,(P/N 71252)required BAT 12120:Battery,l2 volt,12.0 AH(Two required). for Style Y(Class B)operation. Refer to the Device Compatibility Document 15378 for listed BAT-12180: Battery,12 volt, 18.0 AH(Two required). compatible devices. BAT-12260:Battery, 12 volt,26.0 AH(Two required). NAC FOLLOWER OUTPUT REMOTE SYNC(TB18) BB-26: Battery cabinet mounts up to two 26 AH batteries. . Connections for FACP NAC synchronization trigger signal. compo- Wiring Requirements . Output terminals: pass-through to other system compo- 9 4 nents. See product manual, part number LS10001-001NF-E for . Trigger input voltage:9 to 32 VDC,24 VDC rated. detailed wiring requirements. • Input current draw in Alarm condition: 10 mA at rated volt- Total System Capacity: (NFC-50/100(E) age. Only) SPECIAL APPLICATION POWER(AUX. POWER)(TB17) • Total Built-in Audio Power:50 Watts. • 500 mA @ 24 VDC. • Total Expandable Audio Power: 100 Watts. . Used for powering addressable modules and associated End-of-Line power supervision relays. • Total Built-in Speaker Circuits:2. Power-limited circuitry. Refer to the Device Compatibility Docu- • Total Expandable Speaker Circuits:8. ment 15378 for a list of compatible devices. • Audio Message Max Time Duration:60 seconds. External Audio Input: 1. SPEAKER VOLUME CONTROL OVERRIDE(T623) • • Style Y(Class B)or Style Z(Class A)circuit. Total System Capacity: (Fully Loaded . Special application power. System) • Power-limited circuitry,supervised. • Total Distributed Audio Power: 1100 Watts. • Nominal operating voltage:24 VDC.• Total Speaker Circuits Per System:24. • Maximum signaling current:0.25 amps.• Total Remote Consoles Supported:8. . Current limit:fuse-less,electronic,power-limited. • Total Distributed Audio Amplifiers Supported:8. • End-Of-Line Resistor: 4.7 K92, 1/ watt, (P/N 71252) required for Style Y(Class B)operation. Electrical Specifications Speaker Circuits PRIMARY(AC)POWER(TB15) • Primary Speaker Circuit(TB20) NFC-501100: 120 VAC,60 Hz,3.5 amps. • Secondary Speaker Circuit (TB21) (with optional amplifier NFC-501100E:240 VAC,50 Hz,2.0 amps. only). Wire size:minimum#14 AWG(2.00mm2)with 600 V insulation. —Circuit can be wired Style Y(Class B)or Style Z(Class A). —Power-limited circuitry. SECONDARY POWER(BATTERY)CHARGING CIRCUIT(J7) —Normal Operating Voltage:25 VRMS @ 2 amps max and • Supports lead-acid batteries only. maximum Load Impedance of 12.552 (70V @ 700 mA • Float charge voltage at 27.3V max. with maximum load Impedance of 10092 operation • Maximum charge current: 1.0 Amp possible by plugging optional NFC-XRM-70V conversion transformer into J12 of the main control board). • Maximum battery charge capability: 2.8 Amps, 26AH (NFC cabinet holds max. 18AH battery). DN-60772:A1•7/15/13—Page 5 of 8 2140500 Page 11 of 55 —Output Power: 50 watts (10 watts when background • Redundant transceiver circuitry for Class A operability music is employed). • Power-limited circuitry,supervised. —Frequency Range:400Hz-4,000Hz. • Maximum wiring impedance: 13.252. —Maximum total capacitance for each speaker circuit: 250 u F. FACP DA TA Bus(EIA-485)(TB 13) —End-of-Line Resistor required for Style Y circuit: 15 K52, 1 • Dedicated connection to FACP serial bus. watt(P/N: ELR-15K). • Output terminals:pass-through to other system components. • Isolated,supervised. Command Input Circuits (alarm polari- . Minimum isolation withstand voltage: 1500 VRMS. ties shown) • Maximum wiring impedance:4052(ANN-BUS),2652 (ACS-BUS). CMD1 -TB4 Terminals 3(+)&4(-)are input terminals and Ter- • External Audio Riser(TB22). minals 1(-) and 2(+) are output terminals which provide feed . Style Y(Class B)or Style Z(Class A)audio connections to through of the NAC circuits to NAC devices down stream. external operator interface components. CMD2-TB5 Terminals 3(+)&4(-)are input terminals and Ter- . Power-limited circuitry,supervised. minals 1(-) and 2(+) are output terminals which provide feed . Audio signal level:3.85 V, maximum. through of the NAC circuits to NAC devices downstream. • Frequency range:400 Hz-4 KHz RMS. CMD3-TB6 Terminals 1(+)&2(-)are input terminals for con Frequency range(NFC-50/125DA):800Hz-2KHz RMS. tact closure only. CMD4-TB6 Terminals 3(+)&4(-)are input terminals for con- EXTERNAL AUDIO INPUT(TB5) tact closure only. • Input Impedance:8.5K52 nominal @ 1 KHz. CMD5-TB7 Terminals 1(+)&2(-)are input terminals for con- • Input Voltage:700 mV rms maximum. tact closure only. • Input Current:0.1 mA maximum @ 700 mV. CMD6-TB7 Terminals 3(+)&4(-)are input terminals for con- NOTE: Some laptops/personal computers only provide an audio tact closure only. output for headphones. It may be necessary to adjust the head- CMD7-TBS Terminals 1(+)&2(-)are input terminals for con- Phone output level for proper recording of voice messages. tact closure only. NFC-CE6 Circuit Expander Module CMD8-TB8 Terminals 3(+)&4(-)are input terminals for con- Specifications tact closure only. • Power-limited and supervised circuitry. • Power-limited circuitry. • Normal Operating Voltage Range: 10.5 VDC - 29 VDC; • Up to six(6)circuits on the NFC-CE6 can be wired as Style (Maximum Voltage:29 VDC). Y(Class B)or Style Z(Class A). • NAC Reverse Polarity Current(requires End-of-Line Resis- • Normal Operating Voltage for Speaker Circuits: 25 VC 2.0 for from NAC): 1.6 mA maximum. amps max.(Maximum Load Impedance of 12.552). • Contact Closure Operation Current(requires 4.7K(4 1/watt • 70.0 V @ 700 mA max.with maximum Load Impedance of End-of-Line Resistor P/N 27072):6.6 mA maximum. 10052 operation possible for the primary circuit by plugging • Maximum Wiring Impedance CMD1 - CMD8 (Contact Clo- in an optional NFC-XRM-70V conversion transformer into sure Operation):20052. J12 of the main control board.The same operation is possi- ble for the optional 50W amplifier by selecting the NFC- NOTE: When the system is programmed for Mass Notification, BDA-70V model. CMDland CMD2 will be programmed for Reverse Polarity only. . Speaker circuit wiring is supervised during standby, back- See manual P/N LS10001-001 NF-E for more details. ground music,and alarm. MAXIMUM INPUT IMPEDANCE: • Output Power: 50 watts total; Frequency Range: 400Hz - • CMD1 &CMD2(Reverse Polarity Operation):20KU 4,000Hz. • CMD1 -CMD8(Contact Closure Operation):4.75K52. • Maximum total capacitance: 250 NF. (Note that the total capacitance for the speaker outputs must not exceed the NIGHT RING INPUT-TB16, TERMINALS 1(+)&2(-) maximum of 250 NF). • Contact closure input. . End-of-Line Resistor required for Style Y(Class B)speaker • Isolated,non-supervised. circuit: 15 K52, 1 waft (P/N: ELR-15K)TB13 on the main • Operation current:3.8 mA,maximum. control board: ACS/ANN (EIA-485) electrically isolated link • Maximum wiring impedance:30KU to FACP provides programmed speaker control. • Minimum isolation withstand voltage: 1500 VRMS. Cabinet Specifications EXTERNAL OPERATOR INTERFACE POWER OUTPUT(TB24) Backbox: 19.0"(48.26 cm) high x 16.65"(42.29 cm) wide x • Non-resettable power for external operator interface com- 5.20"(13.23 cm)deep. ponents. Door: 19.26" (48.92 cm) high x 16.82"(42.73 cm) wide x • Power-limited circuitry,non-supervised. 0.12"(0.30 cm)deep. • Nominal operating voltage:24 VDC. Trim Ring JR-CE-B): 22.00" (55.88 cm) high x 19.65" (49.91 • Maximum output current:0.80 amps. cm)wide. • Current limit:fuse-less,electronic,power-limited circuit. Shipping Specifications EXTERNAL DATA Bus(EIA-485)(TB12) Base Unit Weight:27.85 lbs(12.63 kg). • Data connections for external operator interface components. Page 6 of 8—DN-60772:A1•7/15/13 2140500 Page 12 of 55 Temperature and Humidity ranges This system meets NFPA requirements for operation at 0-494 C/32-1204 F and at a relative humidity 93% t 2% RH (non- condensing) at 32°C t 2°C (90°F t 3°F). However,the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-274 C/60-804 F. Agency Listings and Approvals The listings and approvals below apply to the basic NFC-50/ 100(E)control panel. In some cases,certain modules may not be listed by certain approval agencies or listing may be in pro- cess.Consult factory for latest listing status. • UL Listed S635. • Compliant with UFC 4-021-01. Standards and Codes The NFC-50/100(E) complies with the following UL Standards and with NFPA 72 Fire Alarm system requirements. • UL 864. • UL 2572. DN-60772:A1•7/15/13—Page 7 of 8 2140500 Page 13 of 55 Notifier®is a registered trademark of Honeywell International Inc. 02013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I O 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING B MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 8 of 8—DN-60772:A1•7/15/13 2140500 Page 14 of 55 DN-60778:A1 First Command �J NOTIFIER 3 NFC-RM Remote Microphone by Honeywell External Remote Console General Notifier's First Command NFC-RM is an optional Remote Microphone that is compatible with the NFC-50/100(E) Emer- gency Voice Evacuation for fire protection applications. It is part of a family of external remote consoles that allows for extending the operator interface to remote locations within a building. It is housed in a cabinet with a keyed lock to limit access to qualified personnel. The NFC-RM remote microphone allows for ALL CALL paging to be broadcast over the speaker circuits when depressing the microphone's push-to talk switch.The RM requires an external data bus connection, an external audio riser connection, and an external operator interface power connection (24 Volts DC) from the NFC-50/100 main console. TYPICAL APPLICATIONS • • Schools • Nursing Homes • Factories • Theaters • Military facilities • Restaurantsby H—f-41 �J • Auditoriums • Places of Worship • Office Buildings Features • External remote console that provides ALL CALL paging broadcasts over the speaker zones of the NFC-50/100(E) primary operating console. agencies or listing may be in process.Consult factory for latest • Modular design for maximum system flexibility and easy listing status. expansion. UL Listed S635. • Supports both Class A(Style 2) and Class B (Style Y)wir- ing. Standards and Codes • A maximum of eight NFC-RM's can be connected to an NFC-50/100(E)primary operating console. The NFC-RM complies with NFPA 101 Life Safety Code and • Built-in microphone with push-to-talk feature that can be with the following UL Standards and with NFPA 72 Fire Alarm used for ALL CALL paging. system requirements. • Sturdy cabinet design with a keyed lock to prevent unautho- UL 864. rized access.Optional thumb lock is available. • Simple and straightforward user interface. Temperature and Humidity ranges This system meets NFPA requirements for operation at 0-4911 Electrical Specifications C/32-120° F and at a relative humidity 93% t 2% RH (non- condensing) at 32°C t 2°C (90°F t 3°F). However, the useful PRIMARY POWER REOUIREMENTS: life of the system's standby batteries and the electronic com- Voltage 24VDC non-resettable power from the NFC-50/ ponents may be adversely affected by extreme temperature 100(E). External Operator Interface Power(Non-supervised). ranges and humidity. Therefore, it is recommended that this See NFC-50/100(E) Product Manual P/N LS10001-001NF-E system and its peripherals be installed in an environment with for standby and alarm current requirements as well as battery a normal room temperature of 15-2711 C/60-8011 F. calculations. Cabinet Specifications Wiring Requirements 8.3"(21.082 cm)high x 6.080"(15.44 cm)wide x 4.337"(11.02 See Product Installation Document PN:LS10029-OOOFL-E cm)deep(Door attached and closed). for detailed wiring requirements. Shipping Specifications Agency Listings and Approvals Weight:4 lbs(1.81 kg). The listings and approvals below apply to the basic NFC-50/ 100(E) Fire emergency voice evacuation system. In some cases, certain modules may not be listed by certain approval DN-60778:A1•7/15/13—Page 1 of 4 2140500 Page 15 of 55 horns/strobes ® e J J NFC-BDA-25/70V optional Internal options amplifier NFC-CE6 circuit expander _ NAC Circuit Speaker Circuits T619 T620&TB21 O O O O WO 0 0 o. o. T C (a" o, � NFC-FFT firefighter telephone Co. ® v. aa. ®; o; • CO © : ®� o ®. o. __0 0 tremote NFC-LOC NFC RPU NFC RM is EMEFOENCY consoles local operator console remote paging unit remote microphone i COMMAND CEA"EN --- FIT:177 I� TB4 •. T612 external battery charger-J7 distributed audio Tg22 14 > o� NFC-50DA 50W NFC-125DA 125W remote amplifier remote amplifier 0. � ®` m:y:: ©©B _-------- -1 a ri Li CHG-120 charger CHG-75 charger NFC-50/100(E) FirstCommand (Possible Configurations) Page 2 of 4—DN-60778:A1•7/15/13 2140500 Page 16 of 55 Control and Indicators PUSH BUTTON CONTROLS • Microphone • Push to talk switch LED STATUS INDICATORS(VISIBLE WITH DOOR CLOSED) • System in Use(green) • OK to Page(green) • AC Power(green) • Data Trouble(yellow) • Audio Trouble(Yellow) • Microphone Trouble(yellow) Product Line Information (Ordering Information) NFC-RM: Remote Microphone only. NFC-50/100: (Primary operating Console) 50 Watt, 25VRMS single speaker zone emergency voice evacuation system, Integral microphone, built in tone generator and 14 recordable messages. Please refer to the data sheet DN-60772 for more information. NFC-50/100E: Export version (Primary operating Console) 50 Watt,25VRMS single speaker zone emergency voice evacua- tion system, Integral microphone, built in tone generator and 14 recordable messages, 240 VAC, 50Hz. Please refer to the data sheet DN-60772 for more information. N-FPJ: Remote Phone Jack. ECC-MICROPHONE: Replacement Microphone Only. CHG-75:25 to 75 ampere-hours(AH)external battery charger. THUMBLTCH:Optional Thumb Latch.(Non UL Listed). SYSTEM IN USE C ON TO GAGE C-) GOWER CD DATA TROMI-E CD AUDIO TROUBLE (-D (� MIC TROUBLE CD �l r DN-60778:A1•7/15/13—Page 3 of 4 2140500 Page 17 of 55 Notifier®is a registered trademark of Honeywell International Inc. 02013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING B MANUFACTURING Made specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60778:A1•7/15/13 2140500 Page 18 of 55 dn-6927:a FCPS-24S6(C/E) & FCPS. 24S8(C/E) �J NOTIFIER° ---7 6- A 8-Amp 24-volt by Honeywell Remote Power Su lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- 2458 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit '. (NAC)expansion(to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system ? • accessories. The FCPS-24S6/-24S8 provides regulated and '' . filtered 24 VDC power to four notification appliance circuits configured as either four Class B(Style Y)or Class A(Style Z, k with ZNAC-4 option module). Alternately,the four outputs may ,r . . . be configured as all non-resettable, all resettable or two non resettable and two resettable. The FCPS-2456/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-2458 used in this document refers to the standard FCPS- 24S6 and FCPS-2458, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E 6)27P �JPB Features Includes integral battery charger capable of charging up to • UL-Listed NAC synchronization using System Sensor, 18 AH batteries. Cabinet capable of housing 7.0 AH batter- Wheelock,or Gentex"Commander2"appliances. ies. • Operates as a "sync-follower' or as a "sync-generator" • Battery charger may be disabled via DIP switch for applica- (default). See note on page 2. tions requiring larger batteries. • Contains two fully-isolated input/control circuits - triggered • Fixed, clamp-type terminal blocks accommodate up to 12 from FACP NAC (NAC expander mode) or jumped perma- AWG(3.1 mm2)wire. nently"ON"(stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with Specifications ZNAC-4 module)NACs. Primary(AC)Power: • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out put, with 3 amps maximum/circuit, in NAC expander mode FCPS 24S6C/24S8C: 120 VAC,60 Hz,3.2A maximum. (UL 864). • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • Wire Size: minimum#14 AWG(2.Omm2)with 600 V insula- output in stand-alone mode(UL 1481). tion. • Compatible with coded inputs;signals passed through. Control Input Circuit: • Optional power-supervision relay(EOLR-1). • Trigger Input Voltage: 9 to 32 VDC. • In stand-alone mode, output power circuits may be config- • Trigger Current: 2.0 mA(16-32 V);Per Input: 1.0 mA(9 ured as: resettable, (reset line from FACP required), - 16 V). non-resettable,or a mix of two and two. Trouble Contact Rating: 5 A at 24 VDC. • Fully regulated and filtered power output-optimal for pow- Auxiliary Power Output: Specific application power 500 mA ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. maximum. • Power-limiting technology meets UL power-limiting require- Output Circuits: ments. • +24 VDC filtered,regulated. • Form-C normally-closed trouble relay. • 3.0 A maximum for any one circuit. • Fully supervised power supply,battery,and NACs. • Total continuous current for all outputs(stand-alone mode): • Selectable earth fault detection. —FCPS-24S6: 4.0 A maximum. • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S8: 6.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- , Total short-term current for all outputs(NAC expander mode): lizes an industry-standard reverse-polarity notification cir- —FCPS-24S6: 6.0 A maximum. cuit(including unfiltered and unregulated bell power). —FCPS-24S8: 8.0 A maximum. • Requires input trigger voltage of 9-32 VDC. Secondary Power(Battery)Charging Circuit: • Self-contained in compact, locking cabinet- 15"H x 14.5"W x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Supports lead-acid batteries only. • Float-charge voltage: 27.6 VDC. dn-6927:a•04/30/09—Page 1 of 2 2140500 Page 19 of 55 • Maximum current charge: 1.5 A. Standards and Codes • Maximum battery capacity: 18 AH. The FCPS-24S6 and FCPS-24S8 comply with the following standards: Applications NFPA 72 National Fire Alarm Code. Example 1: Expand notification appliance power an additional . UL 864 Standard for Control Units for Fire Alarm Systems 6.0 A (FCPS-2456) or 8.0 A (FCPS-24S8). Use up to four (NAC expander mode). Class B (Style Y) outputs or four Class A (Style Z) outputs . UL 1481 Power Supplies for Fire Alarm Systems. (using ZNAC-4). For example,the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the Agency Listings and Approvals FACP through the notification appliance circuit. These listings and approvals apply to the modules specified in Example 2: Use the FCPS to expand auxiliary regulated 24- this document. In some cases,certain modules or applications volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A may not be listed by certain approval agencies, or listing may (FCPS-24S8). Both resettable and non-resettable power be in process.Consult factory for latest listing status. options are available. Resettable outputs are created by con- . UL Listed: S635,S674 necting the resettable output from the FACP to one or both of ULC Listed:S635(FCPS-24S6C&FCPS-24S8C) the FCPS inputs. Example 3: Use addressable control modules to activate the ' CSFM Approved: 7315 0028:225 FCPS instead of activating it through the FACP notification MEA: 299-02-E appliance circuits.This typically allows for mounting the FCPS • FM Approved at greater distances' away from the FACP while expanding system architecture in various applications. Ordering Information For example, an addressable control module is used to acti- FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. vate the FCPS,and an addressable monitor module is used to Includes main printed circuit board, transformers, enclosure sense FCPS trouble conditions. Local auxiliary power output (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and from the FCPS provides power to the addressable control installation instructions. module. FCPS-24S6C: Same as above,ULC-listed. 'NOTE:Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Sync Follower/Generator Note Includes main printed circuit board, transformers, enclosure In some installations, it is necessary to synchronize the flash (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and timing of all strobes in the system for ADA compliance. installation instructions. Strobes accomplish this by monitoring very short timing pulses FCPS-2458: 8.0 A, 120 VAC remote charger power supply on the NAC power which are created by the FACP When Includes main printed circuit board, transformers, enclosure installed at the end of a NAC wire run, the FCPS-2456/-2458 (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and can track (i.e. "follow") the strobe synchronization timing installation instructions. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8C Same as above,ULC-listed. system flash timing of the additional strobes attaches to the FCPS. FCPS 24S8R: Same as FCPS 24S8 with red enclosure. When the FCPS-2456/-2458 is configured(via DIP switch set- FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. tings) as a"sync follower;'the FCPS's NAC outputs track the Includes main printed circuit board, transformers, enclosure strobe synchronization pulses present at the FCPS's sync (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and input terminal.The pulses originate from an upstream FACP or installation instructions. other power supply. ZNAC-4: Class A(Style Y)NAC option module. When the FCPS-24S6/-24S8 are configured (via DIP switch EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire settings) as a"sync generator;'the FCPS's sync input termi- smoke detector power. nals are not used. Rather, the FCPS is the originator of the BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT strobe synchronization pulses on the FCPS's NAC outputs. In Series data sheet DN-6933). "sync generator"mode,the sync type(System Sensor,Whee- lock,or Gentex)is selectable via DIP switch settings. PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. [1iI1E811i 8 MAIMM Mi All specifications are subject to change without notice. QUALITY SYSTEMS Made in theU-S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—do-6927 a•04/30/09 2140500 Page 20 of 55 dn-7114:c•Ai-65 N-ANN-80 �J NOTIFIER SO-Character LCD Serial Annunciator by Honeywell Annunciators General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm,Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- a wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black;for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point S- A (�NOTI FIER information including device type, zone, independent point byHmey.e„ a,,,,: alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- kC✓ EN �•i trol switches for remote control of critical system functions. (A _. keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-BUS of each FACP. Minimal programming is required,which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS,such as the NFW-50. • Trouble Features e Supervisory • Listed to UL Standard 864,9th Edition. • Alarm Silenced • Backlit 80-character LCD display(20 characters x 4 lines). • Mimics all display information from the host panel. Specifications • Control switches for System Acknowledge, Signal Silence, . Operating voltage range: 18 VDC to 28 VDC. Drill,and Reset. Control switches can be independently enabled or disabled Current consumption @ 24 VDC nominal(filtered and non - • resettable):40 mA maximum. at the FACP. Ambient temperature:32°F to 120°F(0°C to 49°C). • Keyswitch enables/disables control switches and mechani- Relative humidity: 93%t 2%RH (noncondensing)at 32°C cally locks annunciator enclosure 13 t 2°C(90'F 3°F). • Keyswitch can be enabled or disabled at the FACP.Enclosure supervised for tamper. 5.375" ((13.655 cm.) high x 6.875" (17.46 cm.) wide x 1.375" • (3.49 cm.)deep. • System status LEDs for AC Power, Alarm, Trouble, Supervi- . For use indoors in a dry location. sory,and Alarm Silence. All connections are power limited and supervised. • Local sounder can be enabled or disabled at the FACP. • N-ANN-80 connects to the ANN-BUS terminal on the FACP Agency Listings and Approvals and requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- The listings and approvals below apply to the N-ANN-80. In ble,supervisory,zone,and custom alpha labels. some cases, certain modules may not be listed by certain • Time-and date display field. approval agencies, or listing may be in process. Consult factory • Surface mount directly to wall or to single, double, or 4" for latest listing status. square electrical box. • UL:S635 • Semi-flush mount to single, double, or 4" square electrical • FM approved box.Use ANN-SB80KIT for angled view mounting. • CSFM:7120-0028:240 • Can be remotely located up to 6,000 feet(1,800 m)from the • MEA:442-06-E Vol.2 panel. • Backlight turns off during AC loss to conserve battery power The ANN-BUS but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote POWERING THE DEVICES ON THE ANN-BUS FROM power supply(requires 24 VDC). AUXILIARY POWER SUPPLY • Up to eight N-ANN-80s can be connected on the ANN-BUS. The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the Controls and Indicators ANN-BUS power requirements. See the FACP manual for more information. • AC Power • Alarm dn-7114:c•5/22/09—Page 1 of 2 2140500 Page 21 of 55 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw, the following Each ANN-BUS device requires a unique address (ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP.A maximum of 8 devices located from the FACP on a single wire run. The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum. In general,the wire length is lim- See the FACP manual for more information ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk('). Maxi- The N-ANN-80 connects to the FACP ANN-BUS communica- mum length can never be more than 6,000 feet (1,800 m), tions circuit.To determine the type of wire and the maximum wir- regardless of gauge used. See table below. ing distance that can be used with FACP ANN-BUS accessory WIRE REQUIREMENTS:POWER CIRCUIT modules,it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75-2.08 mm2) wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. case currents for each module. • All connections are power-limited and supervised. NOTE: For total worst case current draw on a single ANN-BUS • A maximum of eight N-ANN-80 modules may be connected refer to appropriate FACP manual. to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. 6,000 ft. '6.000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 17172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and N-ANN-80:Black 80 character LCD Annunciator. ANN-BUS devices. _ N-ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SBBOKIT-B: Black surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB80KIT W: White surface mount backbox with angled ® B A . - wedge. TBI 4 3 2 1 ANN-BUS Device + A B 0 NFW-50 TB3 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device 02009 by Honeywell International Inc All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IIIIIIEENTT71117 8 M1173 tI" All specifications are subject to change without notice. UMNS QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-7114:c•5/22/09 2140500 Page 22 of 55 DN-7001:D•Ai-380 NOT-BG 12LX �J NOTIFIER Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action . (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG 12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • _ • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm=wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX Addressable Manual Pull Station• Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 Ib. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm)or double-gang boxes(not with single-gang boxes). • Attractive shape and textured finish. • Key reset. Operation • Includes Braille text on station handle. Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • in the down/activated position. Once latched, the word"ACTT- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface box, or will surface mount to the model s 10 or SB-1/0 semi- sur- mounting on matching backbox SB-10 or SB-1/0;or semi-flush face ed,then If the NOT-BG12LX i1 being semi-flush mounting on a standard single-gang, double-gang, or mounted,then the optional trim ring (BG12TR) may be used. 4"(10.16 cm) square electrical box, and shall be installed DN-7001:1).4/13/2012—Page 1 of 2 2140500 Page 23 of 55 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information �i NOTBG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-110:Surface backbox;plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited 'SO 9oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. CTTMT61pNF81Ni 6 NWIIFACTMIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DISI-7001,13•4/13/2012 2140500 Page 24 of 55 DN-6995:C•Ai-320 NP-100(A) Series (�J NOT 1 F 1 E R® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A)adds thermal sen- sors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local,visible sensor indication.Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A) in B210LP(A) Base m DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability, especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming Addressing fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP-25,and 01 –50 with FireWarden-50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple base to simplify installation,service and maintenance. field cleaning. Mount base (all base types) on an electrical backbox which is Operation at least 1.5"(3.81 cm)deep. For a chart of compatible junction • Withstands air velocities up to 4,000 feet-per-minute(20 m/ boxes,see DN-60054. sec.)without triggering a false alarm. NOTE.Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or • Factory preset at 1.5% nominal sensitivity for panel alarm branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed (communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cuit (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0" (10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient pro- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar Cham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a more stable detector. Options • Remote LED output connection, PN RAIOOZ(A). DN-6995:C•12/07/2011—Page 1 of 2 2140500 Page 25 of 55 Detector Sensitivity Test NP-100RA:Same as NP-10OR with ULC Listing for use with a DN RA duct detector housing;B210LPA base included. Each detector can have its sensitivity tested (required per NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE:'A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the NOTE:For details about intelligent bases and their mounting,see sensitivity test can be printed off the FireWarden-100-2 or Fire- DN-60054. Warden-50 for record keeping. 6210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15—32 VDC(peak). B21 OLPBP:Bulk pack of B210LP;package contains 10. Standby current:300 pA @ 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA @ 24 VDC(latched"ON"). B501 BP: Bulk pack of 8501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1"(5.33 cm)high;base determines diameter. Replaces B501 BH series bases in retrofit applications. —B210LP(A):6.1"(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base.Screw termi- -B501(A):4.1"(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm=). Relay type: Form-C.Rating:2.0 —B200SR(A):6.875" (17.46 cm)diameter. A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A 0 30 VDC inductive. —B224RB(A):6.2"(15.748 cm)diameter. Weight:3.6 oz.(102 g). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F); for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C—49°C(32°F—120°F). low-profile. Relative humidity: 10%—93%,non-condensing. F110BP:Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings RAI OOZ(A): Remote LED annunciator.3—32 VDC.Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit listing may be in process. Consult factory for latest listing sta- M02-04-00:Test magnet. tus. M02-09-00:Test magnet with telescoping handle. • UL Listed:S1115. Listed:S911. XR2B: Detector removal tool. Allows installation and/or ULC Li • removal of detector heads from bases in high ceiling applica- • CSFM:7272-0028:0231. tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010: Detector removal tool without pole. Product Line Information BCK-20OB:Black detector covers for use with NP-100(A)only; box of 10. NOTE:"A"suffix indicates ULC Listed model. WCK-20OB: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B21 OLP base only;box of 10. -� included. NP-100A:Sames as NP-100 with ULC Listing; B21OLPA base included. NP-10OT: Same as NP-100 but with thermal element; B21 OLP base included. NP-100TA: Same as NP-100T with ULC Listing; B21OLPA base included. NP-10OR: Remote test capable addressable photoelectric NOTIFIER® and FireWarden@) are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International Inc. 02011. All rights reserved. Unauthorized use of this document is strictly B21OLP base included. prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. (ilpNE01NC B NIAl11NICINIIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6995:C•12/07/2011 2140500 Page 26 of 55 dn-60429:b1 DNR-InnovairFlex �J N OTI F 1 E R° Intelligent Non-Relay Photoelectric Duct Smoke Detector by Honeywell Intelligent Devices General The Notifier InnovairFlex DNR intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelec- tric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector,with its NEMA-4 rating, is listed as a watertight,LIV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute,tem- peratures of -4 degrees F to 158 degrees F, and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) sor cover.The Notifier InnovairFlex housing provides a 3/4-inch Width,2.5 in(6.6 cm)Depth conduit knockout and ample space to facilitate easy wiring and Size: (Square)7.75 in (19.7 cm) Length;9 in (22.9 cm)Width; mounting of a relay module. 2.5 in(6.35 cm)Depth The Notifier InnovairFlex duct smoke detector can be custom- Weight: 1.6 Ib(0.73 kg) ized to meet local codes and specifications without additional Operating Temperature Range:-4 degrees F to 158 degrees F wiring.The new InnovairFlex product line is compatible with all (-20 degrees C to 70 degrees C) previous Innovair models,including remote test accessories. Storage Temperature Range:-22 degrees F to 158 degrees F Features (-30 degrees C to 70 degrees C) Operating Humidity Range:0%to 95%relative humidity(non- • Photoelectric, integrated low-flow technology condensing) • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s) 20.32 m/s) • Versatile mounting options: square or rectangular configura- Accessories tion • Broad ranges for operating temperature (-4F to 158F) and Notifier provides system flexibility with a variety of accessories, humidity(0%to 95%non-condensing) including two remote test stations and different means of visible • Patented sampling tube installs from front or back of the and audible system annunciation.As with our duct smoke detec- detector with no tools required tors,all duct smoke detectors accessories are LIL listed. • Cover tamper signal DNR(W)s with a date code of 0013 or higher do not require • Increased wiring space with a newly added 3/4" conduit external 24VDC for remote test applications when used with a knockout remote-test-capable detector. • Available space within housing to accommodate mounting of ACCESSORY CURRENT LOADS AT 24 VDC a relay module • Easily accessible code wheels on sensor head (sold sepa Device Standby Alarm rately) • Clear cover for convenient visual inspection RA100Z OmA 12 mA Max • Remote testing capability • Requires com line power only RTS151/ OmA 12mA Max • Accommodates the installation of an addressable relay mod- RTS151KEY ule, sold separately, (FIRM-1 or NC-100R) for applications requiring a Form-C relay. dn-60429:b1•07/13/11—Page 1 of 2 2140500 Page 27 of 55 • Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases,certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL:S911,S635 • ULC:S911,S635 • CFSM: 3242-0075:0221 Product Line Information NOTE:A or"CDN"suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately).NEMA-4. FSP-851R: Remote test capable addressable low-profile photo- electric smoke detector. FSP-851:Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. a NP-10OR: Remote test capable addressable low-profile photo- /' electric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A):Metal sampling tube duct width up to 1 ft(0.3m) DST1.5(A):Metal sampling tube duct widths up to 1 ft to 2 ft(0.3 to 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m) DSTS(A): Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m) DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4to3.7m) DH4000E-1:Weatherproof enclosure ETX:Metal exhaust tube duct,width 1 ft(0.3 m) M02-04-00:Test magnet P48-21-00:End cap for metal sampling tubes RA100Z(A):Remote annunciator alarm LED RTS151(A): Remote test station RTS151 KEY(A): Remote test station with key lock Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. ONYX® and NOTIFIER® are registered trademarks and NOTI•FIRE•NETTI is a trademark of Honeywell International Inc. 02011 by Honeywell International Inc-All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ` All specifications are subject to change without notice. �VAllTY SYSTEMS Made in theU.S.A For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60429:b1•07/13/11 2140500 Page 28 of 55 dn-7000:a2•Al-360 NC4 00(A) 0NOTIFIER° Control Module for FireWarden Series Panels by Honeywell Addressable General The NC-100(A) Addressable Control Module provides NOTI- FIER's FireWarden Series intelligent control panels a super- vised Class B (Style Y) of Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability .. allows the NC-100(A) to be activated, either manually or �• through panel programming, on a select(zone or area of cov- erage)basis. TIC 94 WM Features • Built-in type identification automatically identifies these devices to the control panel. " • Internal circuitry powered directly by two-wire SLC loop. The NC-100(A) module requires power(for horns, strobes, etc.). • Integral LED "blinks" when communicating, and turns on x steady when activated. s • High noise immunity(EMF/RFI). • The NC-100(A) may be used to switch 24-volt NAC power. NC-100(A) • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 —99 with FireWarden- 100-2(C),or 01-50 with the FireWarden-50(C). Specifications Applications Normal operating voltage: 15 to 32 VDC. The NC-100(A)is used to switch 24 VDC audible/visual power. Maximum SLC current draw:6.5 mA(LED on). Average operating current:350 pA(LED flashing). Construction External supply voltage:maximum 80 volts(RMS or DC). • The face plate is made of off-white heat-resistant plastic. Drain on external supply: 2 mA maximum (using internal • Controls include two rotary switches for direct-dial entry of EOL relay). address setting. EOL resistance:47K ohms. • The NC-100(A) is configured for a single Class B(Style Y) Temperature range:32°F to 120°F(0°C to 490C). or Class A(Style Z)Notification Appliance Circuit. Humidity range: 10%to 93%non-condensing. Operation Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Each NC-100(A) uses one of the module addresses on a SLC 2 125"(5.398 cm)deep box. loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short Listings and Approvals status of its Notification Appliance Circuit (NAC). The LED Agency 9 PP blinks with each poll received. On command, it activates its In some cases, certain modules may not be listed by certain internal relay.The NC-100(A) supervises Class B(Style Y)or approval agencies, or listing may be in process. Consult fac- Class A(Style Z)notification or control circuits. tory for latest listing status. Upon code command from the panel,the NC-100(A) will dis- • FM approved connect the supervision and connect the external power sup- . UL/ULC Listed:file S635. ply in the proper polarity across the load device. The . CSFM approved:file 7300-0028:230. disconnection of the supervision provides a positive indication pp to the panel that the control relay actually turned ON. The • MEA approved:file 72-01-E Vol.2. external power supply is always relay-isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable)will identify the module to the con- trol panel. dn-7000:a2•06/17/10—Page 1 of 2 2140500 Page 29 of 55 Contact Ratings Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded 5 A 30 VDC Inductive Coded (L/R=5ms) 1 A 30 VDC Inductive Coded (L/R=2ms) .3 A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded Product Line Information NC-100: Intelligent addressable control module. NC-100(A): Intelligent addressable control module,ULC listed version. SMB500:Optional surface-mount backbox. CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as NC-100(A). NOTE: For installation instructions, see document 156-2592-001 and refer to the SLC Wiring Manual, document 52304. The NC- 100R(A) relay module, previously on this data sheet, is now on DN-60383. NOTIFIERO is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I Mli-gicTo-R All specifications are subject to change without notice. INALIT1 SYSTEMS MadeintheU.S.A - For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-7000:a2.06/17/10 2140500 Page 30 of 55 dn-60383:A2 NC-100R(A) �J NOTIFIER` Relay Module for FireWarden Series Panels by Honeywell General The NC-100R(A) Addressable Relay Module provides NOTI- FIER'- FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers,door hold- ers,control equipment, etc. Addressability allows the dry con- "' tact to be activated, either manually or through panel programming,on a select basis. `••`.. �X:. Features • Built-in type identification automatically identifies these n•• _'"" devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 NA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Operation 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Voltage Rating Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE (not settable)will identify the module to the con- Resistive Coded 30 VDC 2.0 A trol panel. Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(L/R=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 2140500 Page 31 of 55 • Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL/ULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module,ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EtRlllENll I i 111101=11111 All specifications are subject to change without notice. lNALITT SYSTEMS Made inthe US.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifieccom Page 2 of 2—dn-60383:A2•06/17/10 2140500 Page 32 of 55 DN-6999:C Monitor Modules NMM-100(A), NMM-100P(A), 0NOT 1 F 1 E W NZM-100(A), and NDM-100(A) by Honeywell for FireWarden Series Panels Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull O stations, or monitor and power a circuit of two-wire smoke - Q detectors(NZM-100(A)). «-•- NMM-100(A)is a standard-sized module(typically mounts to a �'"a • "' i 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. a.,.. .u,. .a,....E• NMM-100P(A) is a miniature monitor module a mere 1.3" zrw (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that �•+ ��� supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be $ mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NMM-100(A)(Type H) NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module f NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- • Built-in type identification automatically identifies this device mal/short) of its Initiating Device Circuit(IDC). A flashing LED as a monitor module to the control panel. indicates that the module is in communication with the control • Powered directly by two-wire SLC loop. No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. N114114-1000) SPECIFICATIONS • SEMS screws with clamping plates for ease of wiring. Nominal operating voltage: 15 to 32 VDC. • Direct Decade entry of address: 01 - 99 on FireWarden Maximum current draw: 5.0 mA(LED on). 100-2,01 -50 on FireWarden-50. • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 com- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each EOL resistance: 47K ohms. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32"F to 120"F(0"C to 49"C). Device Circuit (IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999.0•10/06/2010—Page 1 of 4 2140500 Page 33 of 55 NMM-100P(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x 0.65"(1.651 cm)deep. • Built-in type identification automatically identifies this device Wire length: m(15.24 cm)minimum. as a monitor module to the panel. • • Powered directly by two-wire SLC loop.No additional power NZM.100(A) Interface Module required. • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 1415 0 1 ADDRESS 0 1 a • Direct Decade entry of address:, 01 —99 on FireWarden- s 13 2 1100-2,01 —50 on FireWarden 50. 12 3 • LED flashes during normal operation. 1 O 4 LOOP 0'3 4 . LED latches steady to indicate alarm on command from 10 5 5 control panel. 9 68 9 8 The NZM-100(A)Interface Module is intended for use in intelli- TENS ONES gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors.It transmits the status(nor- OW U mal, open,or alarm)of one full zone of conventional detectors W _O L m back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module OPERATION is selected using rotary switches. It provides a two-wire initiat NZM-100(A) ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- NMM-100P(A)APPLICATIONS mal/short)of its Initiating Device Circuit(IDC). A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device ( ) is wired as an NFPA Style B(Class B) Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- Maximum current draw:5.1 mA(LED on). cuit. Maximum IDC wiring resistance:25 ohms. NMM-100P(A)OPERATION Average operating current: 300 NA, 1 communication and 1 Each NMM-100P(A) uses one of the available module LED flash every 5 seconds,3.9k eol. addresses on an SLC loop. It responds to regular polls from EOL resistance:3.9K ohms. the control panel and reports its type and the status(open/nor mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P A SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms ( ) maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 NA, 1 communication every Humidity range:10%to 93%noncondensing. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC wiring resistance:40 ohms. 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 NA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 Page 34 of 55 2140500 NDM-100(A) Dual Monitor Module MEA: 72-01-E Vol. 2 (NMM-100. NMM-100P, NZM-100), 227-03-E Vol. 3(NDM-100) The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- Product Line Information wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire NOTE:'A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel-a NMM-100(A): Monitor module. controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B) IDC cir- cuits ONLY Style D(Class A)IDC circuits are NOT supported in NZM-100(A):Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual, two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 NA(LED flashing). Manual, PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance:47K ohms Maximum SLC Wiring resistance: 40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses°26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100),7300-0028:0237 (NDM-100) DN-6999.0•10/06/2010—Page 3 of 4 2140500 Page 35 of 55 Notifier®and FireWardens are registered trademarks and FireWatchT"is a trademark of Honeywell International Inc. 022010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MGM9iB0 i NMEFACf�ll6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 2140500 Page 36 of 55 SYSTEM _ SENSOR` - Indoor Selectable- " - F !p A +n""► Output Speaker Strobes and Dual Voltage liet Evacuation Speakers for t Wall Applications M :� The new SpectrAlert'Advance selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster SPECTFNert a � _ installation. Features The SpectrAlert Advance Series of speakers and speaker strobes Plug-in design and protective cover reduce ground faults reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, •Universal mounting plate with an onboard shorting spring tests dress the wires,and confirm wiring continuity before plugging in wiring continuity before installation the speakers.In addition,a protective plastic cover prevents nicked No extension ring required wires by covering exposed speaker components. Field selectable candela settings: Standard:15,15/75,30,75,95,110,1 15 These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected,rotary switches High:135,150,177,185 to select voltage and power settings,and 11 field-selectable candela Automatic selection of 12-or 24-volt operation at 15 and 15/75 settings for both wall and ceiling speaker strobes. candela Rotary switch simplifies field selection of speaker voltage(25 and The low total harmonic distortion of the SP speaker offers high 70.7 Vrms)and power settings(1/4,1/2,1 and 2 watts) fidelity sound output while the SPV speaker offers high volume SP speakers offer high fidelity sound output sound output for use in high ambient noise applications. •SPV speakers offer high volume sound output SpectrAlert Advance makes installation easy •Compatible with System Sensor synchronization protocol Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. Electrical compatibility with existing SpectrAlert products Flush-mount applications do not require an extension ring. •Connect the notification appliance circuit or speaker wiring to the •Optional tamper resistant Torx head screw included terminals on the mounting plate. Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves.Rotate the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Agency Listings SIGNALING NM FM LISTED ,",,® approved ... 7320-1653:201 10-08-E Page 37 of 55 2140500 • SpectrAlert Advance Speaker and Speaker Strobe Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 2'/a-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance speaker strobes, when used with the Sync-Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15,15!75,30,75,95, 110,115,135,150,177,185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°FThe speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon Flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 4"/w x 4"/16 x 2'/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93°x6 non-condensing Dimensions,Wall-Mount SPS Speaker Strobe 6.0 in L x 5.0 in W x 4.7 in D(including lens and speaker) SPSV Speaker Strobe 6.0 in L x 5.0 in W x 4.9 in D(including lens and speaker) SP Speaker 6.0 in L x 5.0 in W x 2.8 in D SPSV Speaker 6.0 in L x 5.0 in W x 2.9 in D Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50VDC Strobe Flash Rate 1 Flash per second Nominal Voltage(strobes) Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire alarm 8 to 175 V(12 V nominal)or 16 to 33V(24V nominal) panels with built in sync) Operating Voltage with MDL Sync Module 9 to 175 V(12 V nominal)or 17 to 33V(24V norninal) Frequency Range 400 to 4000 Hz Power /4,'/2,1,2 watts AVDSCr7800 2140500 Page 38 of 55 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant(dBA @ 10 ft.) 2W 1 W 1/2 W 1A W Wall-Mount SP Series 86 83 80 77 Wall-Mount SPV Series 90 87 84 81 Wall-Mount SPS Series 85 82 79 76 Wall-Mount SPSV Series 89 86 83 80 Dimensions .97- --1.84 5.00„ 2.83.. 1.84„ 5.98 5.9 I 0 0 0 0 0 Wall-Mount SP Speaker Wall-Mount SPS Speaker Strobe �VDS"W Page 39 of 55 2140500 Surface Mounting 0 0 0 0 ° 0 (D of c� Wall-Mount Speaker Strobe with SPBBS Back Box Skirt Ordering Information for SpectrAlerf Advance Speakers and Speaker Strobes _Wall iunt White Red Description SPW SPR Speaker only SPWV SPRV Speaker only,High dB SPSW* SPSR* Speaker Strobe,Selectable Candela(15,15/75,30,75,95,110,115) SPSWH* SPSRH* Speaker Strobe,Selectable Candela,High cd(135,150,177,185) SPSWV* SPSRV* Speaker Strobe,Selectable Candela(15,15/75,30,75,95,110,115),High dB Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SPBBSW SPBBS Wall Mount Back Box Skirt TRW TR Wall Mount Trim Ring •Add-P to model number for plain housing(no'FIRE'marking on the cover)e.g.SPSW-P SYSTEM 02011 System w no for 3825 Ohio Avenue•St.Charles,IL 60174 r�acu sotpmdtcn�w�Dn`rvdLdange the l""""``""`�`Psdats5"nm SENSOR urrentpOduQidartAVDSOO".6/11-12tvoswndNsdansheec Phone:800-SENSOR2•Fax:630-377-6495 nvosoosoo•�ti•rzeo9 Page 40 of 55 2140500 SYSTEM SENSOR Indoor Selectable- E Indo Selectable- output Horns, - Strobes, and y ' Horn Strobes for Wall Applications - SpectrAlertO Advance audible visible notification products SPECTf�lert are rich with features guaranteed to cut installation times A o v A N 11171 BE and maximize profits. i I Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela Like the entire SpectrAlert Advance product line,wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75,30,75, strobes,and horn strobes include a variety of features that increase 95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring continuity before the device is installed. • Compatible with MDL sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING & F M MEA roved 7,25.1653:186(indoor strobes) LISTED APPROVED approved 7125-1653:188(horn strobes. S41-111(chimes,horn strobes,horns) 3023572 MEA452-i chime strobes) 55512(strobes) 7135-1653.189(horns,chimes) Page 41 of 55 2140500 SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1'/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync-Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. 32°F to 120°F(0°C to 49°C) Standard Operating Temperature Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7""W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0-W x 2.2-D(151 mm L x 128 mm W x 56 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW- 5.7"L x 4.8-W x 0.35"D(145 mm L x 122 mm W x 9 mm D) HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15175 cd. AVDSW601 Page 42 of 55 2140500 UL Current Draw Data UL Max.Horn Current Draw(mA RMS) UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 1673 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 llllpll�lplllll llll� ill 11Uluffifflor 8-17.5 Volts 16-33 Volts DC Input 15 15!75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. wosooeoi Page 43 of 55 2140500 SpectrAlert Advance Dimensions 4.7" 2.5 5.05"---►{ 2.23" I II o 5.6" 5.98" 0 0 CD 00 Wall-mount hom strobes Wall back box skirt SpectrAlert Advance Ordering Information DescriptionModel Wall Horn Strobes Horns P2R*t 2-Wire Horn Strobe,Standard cd$,Red HR Horn,Red P2RH* 2-Wire Horn Strobe,High cd,Red HW Horn,White P2W* 2-Wire Horn Strobe,Standard cd,White Accessories P2WH* 2-Wire Horn Strobe,High cd,White BBS-2 Back Box Skirt,Wall,Red P4R* 4-Wire Horn Strobe,Standard cd,Red BBSW-2 Back Box Skirt,Wall,White P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White TRW HS Trim Ring,Wall White Wall Strobes SR*1 Strobe,Standard cd,Red SRH*t Strobe,High cd,Red SW* Strobe,Standard cd,White SWH* Strobe,High cd,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add'-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. t"Standard cd"refers to strobes that include 15,15/75,30,75,95, 110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTEM ®2to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 PodCtsPpndso�s�;ataroirlr ngth�'es°­ ofth sheer SENSOR wm c�eM P oduct infom at on.DS00601 he latest ve s a of h s data sheer Phone:800-SENSOR2•Fax:630-377-6495 nvosoorol•3n2 2140500 Page 44 of 55 DTK-2MHLP Voice, Data and signaling Circuit Modular Surge Protection ii; General Product Specifications DITEK's 2MHLP series of signal, data and loop circuit surge protectors provide robust protection in a compact package. Designed for ease of installation, with convenient field-replaceable modules, the 2MHLP protects two circuit pairs per module. Applications include protection of 4-20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. The DTK-2MHLP is suitable for use on AC and DC circuits. DTK-2MHLP Product Features • Multi-stage, SAD technology, hybrid design provides the best possible protection • Hard-wire mounting base Selection Guide • Field replaceable, hot swappable, modular edge Example: DTK-2MHLP24BWB card connection design DTK-2MHLP B • Six voltage levels available to protect all types of voice/data applications Select Voltage: 5, 12, 24, 36, 48, 75 • Two pairs protected per module; when used with WB: 2MHLP with Single Mounting Base mounting base (DTK-MB) modules can be DTK-MB10: Hardwire mounting base ganged to protect up to ten pairs with a common DTK-MBV: Horizontal wiring across base ground Multiple module mounting bases available separately (DTK-MB, DTK-2MB, DTK-3MB, DTK-4MB, DTK-5MB) • Ten Year Limited Warranty Example: (3) DTK-2MHLP36B + (1) DTK-3MB Specifications Performance Data Agency Approvals: UL497B Model Service MCOV Typical Let Connection Method — Module. Edge card into DTK- DTK- Voltage Through MB mounting base 2MHLP Voltage Base: 10AWG max screw terminals Max Continuous Current: 5 Amps 5B o-5 Volts 5 Volts 6.8 V Max Surge Current: 20kA 12B 12 Volts 18 Volts 21.6 V Data Rate: 200kbps (5v) to 2Mbps (130V) 24B 24 Volts 33 Volts 39V Protection Modes: Line-Ground (All) s 36B 36 Volts 48 Volts 57 V Operating Temperature: -40°F - 158°F (-40°C - 70°C) Maximum Humidity: 95% non-condensing 486 48 Volts 64 Volts 76 v Dimensions 75B 75 Volts 90 Volts 108 V — Module: 1.9"H x 2.1"W x 1.4"D (48mm x 53mm x 36mm) — Module with Base: 2.6"H x 3.25"W x 1.5"D (66mm x 83mm x 38mm) Weight: 1.2 oz (34g) without base; (�L 2.8 oz(79g) with base 11 LISTED Housing: ABS One DITEK Center 1-800-753-2345 Direct: 727-812-5000 Doc. Number: SPS-100010-001©201 Rev 01//14 � � {key Road Technical Support: rp.co472 6100 P gmW {a. n e ''¢¢fit''33771 www.ditekcorp.com S ecificati 9 DTK-120SR 54" Series connected Surge Protector TTEK Genera/Product Specifications ji7 s +t U Mus �TE K' ONE L T P T AS P jZAU110N�114#- MADE IN USA DITEK's DTK-120SR protects 120V power on electrical circuits and control panels. The hybrid series design provides maximum critical load protection, with EMI/RFI filtering. The 120SR is ideal for use in UL Listed control panels where a UL Recognized Component is required for control panel certification. Use DITEK's DTK-TSS4 when a UL Listed series surge protector is required. �. DTK-120SR Specifications Product Features Agency Approvals: UL1449 3rd Edition, cUL, UL1283 Protector Type: Type 4 SPD,for Type 2 Application • Series design for fast response and Nominal Discharge Current Rating (In): 3kA best protection SCCR: 10kA • Compact design fits in a variety of Operating Voltage: 120VAC control panels MCOV: 150VAC • Suitable for use on circuit breakers Peak Surge Current: 54,000 Amps rated at 10kA AIC Maximum Continuous Current: 20A • Multi-stage hybrid circuit design EMI/RFI Attenuation: Up to 35dB, 100kHz-100MHz Protection Modes:All modes(L-N, L-G, N-G) • EMI/RFI filtering Voltage Protection Rating: 600V • LED indicates protection status Temperature Range: 32°F—104°F (0°C-40°C) • UL1449 3rd Edition Recognized Dimensions: 6.87"x 3.50" x 2.50" Component (174.50 mm x 88.90 mm x 63.50 mm) • Ten Year Limited Warranty Weight: 12.16 oz. Housing: ABS tf C us One DITEK Center 1-800-753-2345 Direct 1-727-812-5000 Document:SPS-100007-002 Rev 4 ©2011 DITEK Corp. 1720 Starkey Road Technical Support: 1-888-472-6100 Specification Subject to Change Largo,FL 33771 www.ditekcorp.com Page 46 of 55 2140500 N OT I F I E R Power by Honeywell NFW2-100 Fire Alarm Control Panel Protected Premises: ATLANTIC BEACH COUNTRY CLUB Date: 3/3/2014 Address: 1600 SELVA MARINA DR. City: JACKSONVILLE State: FLORIDA Zip: Prepared By: LIFE SAFETY DESIGNS, INC. Phone: Address: 3038 LENOX AVE. Email: City: JACKSONVILLE State: FLORIDA Zip: 32254 AC Branch Current Requirements 3.00 AMPS @ 120 VAC Current required by source to power the fire alarm system. Primary Standby Load 0.05 Amps Current load on the primary power supply during non-alarm conditions. Primary Alarm Load 3.98 Amps Current load on the primary power supply during alarm conditions. Secondary Load Requirements 5.35 Amp Hours Total Secondary Load from the calculation table below. Secondary Standby Load x Required Standby Time 0.171 A 24 hours 1 4.10 Secondary Alarm Load x Required Alarm Time (hours) 4.259 A 0.084 hours 0.36 Total Secondary Load 4.46 Derating factor x 1.2 Secondary Load Requirements 5.35 AH Battery Selection CJ Amp Hours Select batteries from the list below. 7 AH BAT-1270 Battery 12 volt) E Two Ll Four(two 12VDC sets in parallel) Page 1 of 3 Page 47 of 55 2140500 Battery Distribution Chart Shows amp-hour distribution of your selections. Secondary Alarm Load i Spare Battery Capacity 6% ■Secondary Standby Load Spare Battery Secondary Alarm Load Capacity 24 II ' Secondary Standby Load 70 Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-18AH). Spare Battery Capacity (AH)-Secondary Load Requirements(AH) Secondary Standby Load ����Selection Load coed Derating Factor Secondary Alarm Load Load(AH)"Derating Factor Page 2 of 3 Page 48 of 55 2140500 NOTIFIER' by Honeywell Mi NFW2-100 Fire Alarm Control Panel Quantity x[device current draw]=total current draw per device(in amps) ,. FMI . Main Circuit Board 1 x.0.00000 =0.0000 x 0.00000 =0.0000 x 0.14500 =0.1450 XRM-24B 1 x 0.00000 =0.0000 x 0.00000 =0.0000 x 0.00000 =0.0000 SPSR110 4 x[0.00000 =0.0000 x[0.20200]=0.8080 x 0.00000 =0.0000 SPSR75 2 x 0.00000 =0.0000 x 0.15800 =0.3160 x 0.00000 =0.0000 SPSR30 2 x 0.00000 =0.0000 x 0.09400 =0.1880 x 0.00000 =0.0000 SPSR15 11 x 0.00000 =0.0000 x 0.06600 =0.7260 x 0.00000 =0.0000 SR75 1 x 0.000001=0.0000 x[0.15800 =0.1580 x 0.00000]=0.0000 SR30 1 x 0.00000 =0.0000 x[0.094001 0.0940 x 0.00000 =0.0000 SR15 19 x fo.onnnol=0.0000 x[0.066001 1.2540 x 0.00000 =0.0000 N-ANN-80 1 x[0.037001=0.0370 x 0.04000 =0.0400 x 0.01500 =0.0150 NP-100 1 x 0.00030]=0.0003 x[0.00000]=0.0000 x[0.00030 =0.0003 NP-10OR 18 x 0.00030 =0.0054 x 11= x fO.000301=0.0054 NMM-100 5 x 10.000401=0.0020 x 10.000001=0.0000 x 0.00040 =0.0020 NOT-BG12LX 1 x[0.00023]=0.0002 x 0.000001=0.0000 x[0.00023]=0.0002 NC-100 1 x 0.00039 =0.0003 x 0.00000 =0.00000 x 0.000 91=0.0003 NC 100R 10 x 0.00027 =0.0027 x jU.UuUUUJ=0.0000 x 0.00027 =0.0027 Max Alarm Draw-All Addressable t(Amperes):Devi 1 x 0.00000 =0.0000 x 0.40000 0.4000 x 0.00000 0.0000 Total : 0.0480 A 3.9840 A 0.1710 A T-UNINIFIF Flu w Total Primary Alarm Load-C21 x 3.98400 =3.9840 Main Circuit Board 1 x 0.27500 =0.2750 Total(Amperes):1 4.2590 A Page 49 of 55 2140500 i LIFEIDSAFET9 D E S I G N S SIGNAL POWER CALCULATION NOTIFIER (NFW2-100) FIRE ALARM CONTROL PANEL ATLANTIC BEACH COUNTRY CLUB 1600 SELVA MARINA DR. JACKSONVILLE,FLORIDA JOB No.2140500 DATE:MARCH 3,2014 ALL SIGNAL CIRCUITS HAVE A 2.5 AMP RATING PART No. No. NON-ALARM ALARM TOTAL AMPS SIGNAL CIRCUIT No. 1 SPSR-110cd 3 0 0.202 0.606 SPSR-75cd 2 0 0.158 0.316 SPSR-30cd 1 0 0.094 0.094 SPSR-15cd 2 0 0.066 0.132 SR-75cd 1 0 0.158 0.158 SR-15cd 2 0 0.066 0.132 SIGNAL CIRCUIT TOTAL AMPS= 1.438 SIGNAL CIRCUIT No. 2 SPSR-15cd 2 0 0.066 0.132 SR-15cd 2 0 0.066 0.132 SIGNAL CIRCUIT TOTAL AMPS= 0.264 SIGNAL CIRCUIT No.3 SPSR-15cd 6 0 0.066 0.396 SR-30cd 1 0 0.094 0.094 SR-15cd 6 0 0.066 0.396 SIGNAL CIRCUIT TOTAL AMPS= 0.886 SIGNAL CIRCUIT No. 4 SPSR-110cd 1 0 0.202 0.202 SPSR-30cd 1 0 0.094 0.094 SPSR-15cd 1 0 0.066 0.066 SR-15cd 3 0 0.066 0.198 SIGNAL CIRCUIT TOTAL AMPS= 0.560 Page 50 of 55 2140500 • Calculation Column 1 Calculation Column 1 Calculation Column 2 Device Type Secondary(Battery)Power Source Secondary(Battery)Power Source Secondary(Battery)Power Source Standby Current(amps) Standby Current(amps) Alarm Current(amps) Qty Draw Total Qty X [current draw] = total Qty X [current draw] = total NFC-50/100 Primary Console 1 X 0.272 0.272 1 X [0.2721= 0.272 1 X [0.446]= 0.446 (Not including speaker load) NFC-BDA-25/70V 1 X 0.100 0.100 [ 1 ] (1 max.)X[0.1001= 1.100 J [1 1(1 max.)X[0.235]= (.235 1 Optional Audio Amplifier Module t NFC-CE6 Speaker Circuit Expander 0 X 0.020 0 [ ] (i max.) X [0.0201= [ ] [ ] (1 max.) X [0.189]= [ ] NFC-LOC Local Operator Console 2 0 X 0.085 0 [ ] X [0.085]= ( ] [ ] X [0.100]= ( ] NFC-RM Remote Microphone 2 1 X 0.050 0.050 [1] X [0.050]= [.0501 [1] X [00641= [.0641 NFC-RPU Remote Page Unit 2 0 X 0.050 0 [ ] X [0.050]= I ] [ ] X 10.0681= [ ] NFC-50/125DA 3 0 X 0.012 0 [ ] X [0.012]= [ ] [ ] X 10.0121= [ ] NFC-FFT Firefighter Telephone 0 X 0.120 0 [ j X [0.120]= ( ] [ ] X [0.230]= [ ] Speakers(50 watts maximum/amplifier) [ ] x[0.017)= '114 wan [ 1 r- [22] x[p.033]= [7261 t/2 Watt X[0.050]= 314 Watt [ 1 [a) x[0.068]= [2721 1 Watt X[0.132]= [ 1 2 Watts Additional Current Draw from TBt7 Special 0 [ 1 X [ 1= [ J [ ] X Application Auxiliary Power Output (0.5 0 X 0 amp maximum) X NAC Circuit Output(2.0 amps maximum) : [ ] [ 1= [ 1 Power Supervision Relays 4 0 X 0.025 0 [ ] X [0.0251= [ J ( ] X [0.025]= [ ] AIM-1A,RSM-1A Isolators 0 X 0.0145 0 [ ] X [0.01451= [ 1 [ ] X [0.0145]= [ ] SP-SVC Volume Control 0 X 0.010 0 [ ] X [0.0101= I 1 I 1 X [0.010]= [ ] Total Secondary Standby: Secondary Standby: .422 Secondary Alarm: 1.743 equirea Standby time Feconry n y oa [:'(o 4 or 60 hours) 10.128 AH Calculation Column 1) 24] equired Alarm Time ry Alarm Load or 5 min.,enter 0.084, Calculation Column 2 r 10 min.,enter 0.168, 3 ] r 15 min.,enter 0.250) for 30 min.,enter 0.50) 436 AH [ .250 ] 10.564 AH Sum of Standby and Alarm Ampere Hours X 1.2 Multiply by the Derating Factor 12.677 AH Battery Size,Total Ampere Hours Required Page 51 of 55 2140500 NOT IFIER' System Power Requirements by Honeywell FCPS-24s8 Power Supply Protected Premises: ATLANTIC BEACH COUNTRY CLUB Date: 3/3/2014 Address: 1600 SELVA MARINA DR. City: JACKSONVILLE State: FLORIDA Zip: Prepared By: LIFE SAFETY DESIGNS, INC. Phone: Address: 3038 LENOX AVE. Email: City: JACKSONVILLE State: FLORIDA Zip: 32254 AC Branch Current Requirements 3.20 AMPS @ 120 VAC Current required by source to power the fire alarm system. Primary Standby Load 0.09 Amps Current load on the primary power supply during non-alarm conditions. Primary Alarm Load 1.80 Amps Current load on the primary power supply during alarm conditions. Secondary Load Requirements 2.05 Amp Hours Total Secondary Load from the calculation table below. Current Draw Time (hours) Total (AH) Secondary Standby Loadx Required Standby Time 0.065 A 24 hours 1.56 Secondary Alarm Load x Required Alarm Time (hours) 1.801 A 0.084 hours 0.15 Total Secondary Load 1.71 Derating factor x 1.2 Secondary Load Requirements 2.05 AH Battery Selection L—=J Amp Hours Select batteries from the list below. 7 AH BAT-1270 Battery (12 volt) C'Two C;Four(two 12VDC sets in parallel) Page 1 of 3 Page 52 of 55 2140500 Battery Distribution Chart Shows amp-hour distribution of your selections. ■Spare Battery Capacity Secondary Alarm Load 2/ ■Secondary Standby Load Secondary Standby Load Zy% Secondary Alarm Load a i Spare .-,._Battery apacity Comments 1. Batteries will fit in the FACP cabinet. 2. Selected battery size meets secondary load requirements. 3. The selected batteries (7AH) are within the charger range of this power supply (7-18AH). E are�Standby 4.95 Batte Selection(AH)-Secondary Load Requiremeco1.87 Secondary Standby Load(AH)-Derating Factor Seco0.18 Secondary Alarm Load(AH)`Derating Factor Page 2 of 3 Page 53 of 55 2140500 NpTi F1 ER S-24s8 Power SupP�Y per device(In amp' ✓� b Hone ell FCF total current draw p , x 0.06500 =0.0650 Quantity x[device current draw]_ =0.1450 =0.0000 x 0.14500 x p.00000 =0.0910 =p.1580 x[0 00000 =0.0000 1 x 0.09100 0 0000 x 0.15800 0 2820 =0.0000 x 0.00000 x 0.09400]= x p.00000 •FCP,-2458 Main Circuit Board 1 0 0000 =0.1980 x p.00000 =0.0000 3 x[0.00000] _0 0000 x 0.06600 0 p940 =p 0000 SP,R75 x 0.00000 x 0.09400 x 0 00000 SP,R30 3 0.0000 0 9240 1 x 0.00000 = x 0.06600 = SP,R15 0 0000 0.0650 SR30 14 x 0.00000 = 1•g010 A SR15 0.0910 Total(Amperes): ,.jo5nn 'v LIFE SAFET9 10 D E S I G N S SIGNAL POWER CALCULATION NOTIFIER (FCPS-24S8) AUXILIARY POWER SUPPLY ATLANTIC BEACH COUNTRY CLUB 1600 SELVA MARINA DR. JACKSONVILLE,FLORIDA JOB No.2140500 DATE:MARCH 3,2014 ALL SIGNAL CIRCUITS HAVE A 2.5 AMP RATING PART No. No. NON-ALARM ALARM TOTAL AMPS SIGNAL CIRCUIT No.5 SPSR-15cd 2 0 0.066 0.132 SIGNAL CIRCUIT TOTAL AMPS= 0.132 SIGNAL CIRCUIT No.6 SPSR-75cd 1 0 0.158 0.158 SPSR-30cd 3 0 0.094 0.282 SPSR-15cd 1 0 0.066 0.066 SR-30cd 1 0 0.094 0.094 SR-15cd 6 0 0.066 0.396 SIGNAL CIRCUIT TOTAL AMPS= 0.996 SIGNAL CIRCUIT No.7 SIGNAL CIRCUIT TOTAL AMPS= 0.000 SIGNAL CIRCUIT No. 8 SIGNAL CIRCUIT TOTAL AMPS = 0.000 Page 55 of 55 2140500