Loading...
2247 Beach comber Trl 2014 HVAC r CITY OF ATLANTIC BEACH SJ 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number - 14-00000639 Date 4/23/14 Property Address . . . . . . 2247 BEACHCOMBER TR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . 0 -------------------------- Application desc 1 cu 1 ahu - ------- -------------------------- Contractor Owner DONOVAN HEATING & AIR BURGIN, CHRISTOPHER & LAURA 315 SIXTH AVENUE SOUTH 2247 BEACHCOMBER TRAIL JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-3785 __ ---- -----Permit---- _ MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee . . . . 99 . 00 0 Valuation Issue Date • • • . 10/20/14 Expiration Date ------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES. NO EXCEPTIONS . ------------ --- ---------------- STATE MECH DCA SURCHARGE 2 . 00 Other Fees _ 2 . 00 STATE MECH DBPR SURCHARGE ------------------------ --------------- ------------------ Credited Due Fee summary Charged Paid ---------- - ---------- . 00 ---------- ----------------- 99 . 00 99 . 00 . 00 Permit Fee Total 00 00 . 00 Plan Check Total 00 4 . 00 00 . 00 4 . 00 Other Fee Total . 00 . 00 Grand Total 103 . 00 103 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: U �� J � d C©m BCP-- _PERMIT# PROJECT VALUE $ 40602— ARI# 39 aS -7,S-7 REQUIRED Air Handling Equipment Only , Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 3 Heat: Unit Quantity_�_ BTU's Per Unit 3byca0 Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Re uires 3 sets of plans) ( Fire Sprinkler System Quantity ( q (Requires 3 sets of plans) Fire Standpipe Quantity quires 3 sets of plans) Underground Fire Main Value (Requires Fire Hose Cabinets Quantity (Requires 3 sets of plans) (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Boilers BTU's Gas Piping Outlets Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not te true and corrtect All provisions hin a six th ofdlaws and ordinances or work is egovernd or ng this donedwork wilor six l betcomplied with whetherfy t pec feed o� its application and know the same to ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. �Q�S ���.i r Phone Number a 46 'C7�b Property Owners Name e ^,� Office Ph yl 37 J Fax a y�37 If Mechanical Company D 0'10;1 ur �eAr �`'� State Et Zip 3225 6 Co. Address: 3�� Ayt s City A'Z x �� Holder(Print): i ! �ON UJ��l� State Certification/Registration# .2 License ( ) Notarized Signature of License Holder / 20 �� Before me this day of .s comH mis sARD on#FF 04 399 TOMPKINS :a x. ,zi Expires July 29,2017 Signature of Notary Public �, SwWW Tlw Troy Fan Incur nm 899385.7019 Project Summa Job: + Wrightsoft � � Date: April 23,2014 Enure House By: Aaron Thacker Donovan Heat&Air 315 6th Are S,Jacksornille Beach,FL 32250 Phone:904241-3785 Fax:904-241-3745 Email:aaron@donovanac.corn Web:www.DonovanAC.corn Project • • For: Chris Burgin 2247 Beachcomber Trail, Atlantic Beach, FL 32233 Notes: D' sn_Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 20836 Btuh Ducts 4738 Btuh Ducts 4620 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh piping 0 Btuh Equipment load 31442 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25456 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1154 Btuh Ducts 1970 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft2) 1040 1040 Equipment latent load 3124 Btuh Volume (W) 8320 8320 Air changes/hour 0.45 0.23 Equipment total load 28580 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 13 PURON HP Trade COMFORT 13 PURON HP Model 25HCB336A30 Cond 25HC6336A30 AHRI ref no3405757 Coil FV4CN(B,F)003 AH R I ref no 340575 Efficiency 8.1 HSPF Efficiency 11.7 EER, 14.5 SEER Heating input Sensible cooling 23940 Btuh Heating output 34400 Btuh @ 47°F Latent cooling 10260 Btuh Temperature rise 27 OF Total cooling 34200 Btuh Actual air flow 1140 cfm Actual air flow 1140 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsofi 2014-Apr-23 09:15:22 Right-Suite®Universal 8.0.24 RSU05995 Pagel C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton,rup Calc=MJ8 Front Door faces: S