Loading...
2233 Seminole Rd # 36 HVAC CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 J INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000659 Date 4/28/14 Property Address . . . . . . 2233 SEMINOLE RD UNIT 036 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ------------------------------------ Application desc 1 cu 1 ahu ------------------------------------ Owner Contractor ------------------------ NASRALLAH, KAREN V. SERVICE EXPERTS 2233 SEMINOLE RD #36 8475 WESTERN WAY STE FL 32256 ATLANTIC BEACH FL 32233 (9JACKSONVILLE L 182 ----------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc Plan Check Fee . 00 Permit Fee 95 . 00 . Valuation Issue Date Expiration Date . . 10/25/14 ---------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . -------------------------------------------------- Other -------------------------------- 2 . 00 Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE STATE MECH DBPR SURCHARGE 2 . 00 _ ________ --- Fee summary Charged Paid Credited _ _ ------ -- ----- ---------- ---------- - . 00 Permit Fee Total 95 . 00 95 . 00 00 . 00 Plan Check Total • 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION [ CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: _�;2 33i'>r? !✓C��- /��-44 36o _PERMIT# PROJECT VALUE $ 6 S Q © ARI# S/��SS l REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit J. 'S + v Heat: Unit Quantity BTU's Per Unit C dye Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name �¢n P jt> �—S 1 1 4 1� Phone Number Mechanical Company Service Experts Office Phone 271-2182_Fax Co. Address: 8475 Western Way Suite 100 City Jacksonville State Fl Zip 32256 License Holder(Print): Carey Zarm State Certificat Registration# CAC 1817129 lder •��,µ`i CAflOL A.BRESSLER efore me this day of < 20� Notary Public-State of Florida y� d My Comm. Expires Jul 5,2014 L .•- .����� Commission # EE 36112 gnature of Notary Public Ulm CERTIFIED O www.aliridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5725541 Date: 4/28/2014 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13HPX-030-230-17 Indoor Unit Model Number: CBX25UH-030-230 * Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: 13HPX SERIES Series name: Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI ? cfor nieAir-Source and Heat Pump Equipment and subject to verification Standard rating acuacybyAHRIsponsoed, independent, third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 27000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 17300 "Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility or, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS _ This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and �, confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; �. .■ entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING, personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION y g y we make life better" The information for the model cited on this certificate can be verified at www.ahriate waor or click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, — which is listed above,and the Certificate No.,which is listed at bottom right. 130431558841922941 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: Street Addres'S 2233 Seminole fid � 3 �, Atlantic: Beach, 32233 Latitude, Longitude 30.3375°, -81.76860 House Square 1307 sq. ft. Footage: Auk— Name: Karen Nasrallah ............ ..........- Phone: 904-247-0840 ....._...._ ....................................................... .. .. ....... Email: Wayne.furr@serviceexperts.com �House Information SHR .75 ......................................................_............................................... _.. ........................... Number of residents 4 ..................................................................................................................Ceiling height $ ........................................................................................... Wall U-value R-value 0.09 11 Floor U-value ( R-value 0.2 ( 5 ...._................................_...,....................................__.........................................................._......_..... Ceiling U-value I R-value 0.053 1 19 ..........................._.................................................................................. . .................... Window U-value 0.5 ................ ................................ .........._............. Window SHGF 0.85 ..........._... . ............................................................................_..........._.........._....... Moisture grains 53 ........................................._....................._................................._.........................._............. . Duct loss % 10 ................. .... Duct gain % 10 Cooling infiltraction (ACH) 0.6 .......................-................-................................................................................................... Heating infiltration (ACH) 0.8 ................................................... .. _. Winter ventilation 0 . .. ................. ...... 0 Summer ventilation ..................-................................................................................................................................................ 'Design Conditions outdoorHeating Cooling .............. ............... Dry bulb ('F) 32 95 .............I ..-- I........... ..................................................................................................... ..................................... Daily range M -.-I I.................1.111.11.11...................... ..........I................... .................... ..................... ............11..................... ............................................. ............. Relative humidity50% ....................- I - I -............I................................... ................... ................. ....................................................... Moisture difference 53 ..............I.........................I................................. ..............................I.........................I.................... ...................................-...........................-.1-.1..................I--........................... Indoor Cooling .................... .. ...........-1............. ...................................................... ....................- .................... ............. ..... indoor temperature ('F) 70 75 -................. 1"....,.............. I................--.1................. ............ ...................-............................. ............. ............................... ................... Design temperature difference(OF) 38 20 .................................I................................................................................................................... ................................................................I................................................... ............................................. �Heating Loads ..................... Area Btuh % of load.....v-...........................Wf................ ................ Wall 3498 15.6 -.-.................................................... ................................11-1........................ Floor 6255 27.9 -.................. ................................................................-........................................I........................... Ceiling 2632 11.8 ............. .................. ........................... Windows 2546 11.4 ...........................................................--........... .................... .....................I-.- .-I I............. infiltration 5420 24.2 11,.......... -............................................................. -11.1.1............. System Efficiency Loss 2035 9.1 -...............-.......................................................................................I I I................... ........................... Total: 22386 ........................................... 1111............. ...................... Heating Loads 22,386 BTU/fir System Efficiency Loss Floor Windows i'� it ly Ceiling W Infiltration ,CoolinaLoads Btuh Area % of load .......... Wall 1841 7.4 ..........................._................I . ._.............. _....... Ceiling 3117 12..5 ................ ...... Windows 8127 32.7 4 sensible Infiltration 2139 8.6 Latent Infiltration 3505 1.4.1 Systern Efficiency Gain 1873 7.5 Internal 2400 7 --)ensibie People Load 920 Latent People Load 920 7 Total: 24,8 2 Sensible load 20418 Latent load 4425 .... SHR 0.82 + Capacity at .75 SHR 2.27 Tons ......... ... ...... ..........................._- cooling Loads 24,842 BTU/hr Sensible People Load Latent People Load Wall Windows -1-1 � System Efficiency( Sensible Infiltrati( Internal Latent Infiltration J Ceiling ................. ' "� VV|Dte[ UUuduu/