141 15th St 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
1 /"jilt
Application Number . . . . . 14-00000662 Date 4/28/14
Property Address . . . . . . 141 15TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 --------------
--------------------------------------------------------------
Application desc
2 cu 2 ahu
---------------------------------------------
Owner Contractor
------------------------
------------------------
AMES, WILLIAM H & REBECCA A DONOVAN HEATING & AIR
141 15TH ST 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
-- -------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc - -
Permit Fee . . . . 131 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/25/14 -----------------------
-------------------------------------------- --------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS . --------------
-------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
---------- -----------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 131 . 00 131 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 135 . 00 135 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BE, ACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
roB AwDRiEss: LS—77'. 5T PERMU #
PROJECT VALUE $ ARI# '99�Z Gq1 ASI601-1 REQUIRED
i
Air Handling Equipment Only K_Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity 7- Tons Per Unit
Heat: Unit Quantity BTUs Per UnitZw& 0 SeerRating 1-5 /IY75�
Duct Systems: Total CFM �Ijxm RE—QVIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quailtity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
4 Vented Wall Furnaces Reftigerator Condenser BTU's
4- Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
hat I have read
Permit becomes void if work does not commence 77iiin a'six month period or work ism7!pcn0=cd or abandon�d for sixm months. I hereby certify t
iis appi ical ion and know the same to be trilc and correct. All provisions of laws and ordinances governing thiq work will be complied with wlictlicr specified or
ot. The petmit does not give author I t to violate the prov --ims of any other state or local law regulation construction or the performanec of construction.
Property OvAiers Name LL.Axae--� Phone Number ;2!K2- 199�,
-1
Mechanical Company 'DmOV&�-JEAI i 11C Office PhoneZV-370 . Fax 2q] 3-7ql-,,..
�&j City�gt Sc4 _Statefl zip322f-0
Co. Address: — I —
State Certification/Registrationi�, co
License Holder(Print): --Vjj1hAZn—,,
Notarized Signature of License 11older tZ=
I 20M
X1"', HARD TOMP Before me this
1$ Ric KIN$ day
IM .4 Commisslon#IFF 040399
Expires July 29,2017
Ronund T%TftrOn Inaumma 200-MG-700 Signature of Notary Public
Job,
Project SuMmary Deft: 4i2WI4
wrightsoft- Entim House By: Brandon Zaharie
Donovan Heat & Air
315 Sth ova soLah,jaCkSonville Beach,FL 32260 PhOMO:241,3795 Email:bMnd0n@donovanac com
Project Information
For: Ames
141 15th st,Atlantic Beach, FL 32233
Notes-.
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions ,
Outside db 39 "F Outside db 96 'IF
Inside db 68 OF Inside db 75 OF
Design TD 29 OF e�in D 20 T
D'911Y r T L
D ange
Relative humidity 50 %
Moisture difference 53 gr1lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14414 Btuh Structure 14371 Btuh
Ducts 3195 Btuh Ducts 4674 Btuh
Central vent (13 cfrn) 409 Btuh Central vent (13 cfm) 282 Btuh
Humidification 0 Btuh Slower 0 Stuh
Piping 0 Stuh
18019 Btuh use manufac4urer's data n
Equipment load Ratelswing multi lier 1.00
Infiltration Equipment sensigle load 19327 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1921 Btuh
Fireplaces 1 (Average) Structure 1006 Btuh
Ducts 465 Stuh
Heatina Cooling Central vent (13 cfm)
Area(ft 2� 1215 121 Equipment latent load 3392 Btuh
Volume ft3) 10962 10962 Equipment total load 22718 Btuh
Air chanqes/hour 0.56 0,23
Equiv.AVF (cfm) 102 42 Req. total capacity at 0.70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make American Standard Make American Standard
Trade Trade 4A6H5030
Model 4A6H5030 Cond
Coil GAM51330
ARI ref no, 5863593 ARI ref no. W3593 15 EER
Efficiency 8.5 HSPF Efficiency
Sensible cooling 20906 Btuh
Heating input 8960 Btuh
Heating output 29717 Btuh @ 47'F Latent Cooling
'U OF Total cooling 29866 Stuh
Temperature rise 801 cfm
Actual air flow 801 ofm Actual air flow 0,042 cfm/Btuh
Air flow factor 0.045 cfm/Btuh Air flow factor 0 in H20
Static pressure 0 in H20 Static pressure
Load sensible heat ratio 0-85
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2014-Apr-26 11:32,06
R lght-$uitet Univemmi 7.1.D1 R SU OS996 page I
c;\use rs\s9iamDccum ent.imrioms oft HVAC\2.5 TON C31C=MJG OflentBflon�-N
Project Summary Job:
wrightsoft- Date: 4M5114
Entire House By; Brandon Zaharie
Donovan Heat & Air
315atMnve:�outh,Jacki3onvilialaench,,FL3225OPhono;241-3785 Email:bmndongdonovanAo.corn
Project Information
For: Ames
141 15th st,Atlantic Beach, FL 32233
Notes,
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 6F Outside db 95 `F
Inside db 68 OF Inside db 75 OF
Design TD 29 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 13919 Btuh Structure 11729 Stuh
Ducts 2799 Stuh Ducts 5690 Btuh
Central vent (12 cfm) 370 Btuh Central vent (12 cfm) 255 Btuh
Humidification 0 Btuh Blower 0 Btuh
plpl�g 0 Btuh
Equipment load 17088 Stuh Use manufacturer's data n
Rate/swin multiplier 1.00
Infiltration Equipmen?sensible load 17674 Stuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1638 Btuh
Ducts 973 Btuh
Heafin Coolln Central vent (12 cfm) 420 Btuh
Area (ft2) 1152 1152 Equipment latent load 3031 Btuh
Volume(ft") 10368 10368
Air changes/hour 0.57 0.23 Equipment total load 20706 Btuh
Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2A ton
Heating Equipment Summary Cooling Equipment Summary
Make American standard Make American standard
Trade Trade
Model 4A6H5024 Cond 4A6H5024
ARI ref no. 5863591 Coil GAM5BOA24
ARI ref no. 5863591
Efficiency 8.5 HSPF Efficiency 14.8 SEER
Heating input Sensible cooling 1574-7 Btuh
Heating output� 22384 Stuh @ 470F Latent cooling 6749 Stuh
Temperature rise 27 OF Total cooling 22496 Btuh
Actual air flow 750 cfm Actual air flow 750 cfm
Air flaw factor 0.045 cfm/Btuh Air flow factor 0,043 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.85
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
& -Of+- Right-Suftet univer4al 7,1.01 RSU0508 2014-Apr-25 11:27:50
c:\usemksAioa\r)ocumL-.nt��WrigMtsofI 1-1VACk2Ton.rup C nh:=RAJ8 Orleninflom Nip I