317 Seminole Rd 2014 HVAC �s kk CITY OF ATLANTIC BEACH
sj 800 SEMINOLE ROAD
r} ATLANTIC BEACH,FL 32233
J < INSPECTION PHONE LINE 247-5814
14-00000656 Date 4/28/14
Application Number � � 317 SEMINOLE RD
Property Address . .
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . 0
----------------------------
Application desc
1 cu 1 ahu
---------------------------
Contractor
Owner
---------------
KAEUPER, KEVIN C DONOVAN HEATING & AIR
317 SEMINOLE ROAD 315 SIXTH AVENUE SOUTH
JACKSONVILLE BEACH FL 32250
ATLANTIC BEACH FL 32233 (904) 241-3785
_ ---
-----Permit
• MECHANICAL HVAC PERMIT
Additional desc • Plan Check Fee . 00
Permit Fee . . . . 95 . 00 0
Valuation
Issue Date • • • ' 10/25/14
Expiration Date .
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS . -----------------------------
_ -----
----- 2 . 00
Other Fees
, . . STATE MECH DCA SURCHARGE 2 , 00
STATE MECH DBPR SURCHARGE
---------------------------------------Paid------Credited
Due
Fee summary Charged
--------- ---------- . 00
. 00
Permit Fee Total 95 . 00 95 . 00 - 00. 00 . 00 . 00
Plan Check Total 4 . 00 . 00 . 00
Other Fee Total 4 . 00 00 . 00
Grand Total 99 . 00 99 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
S00 Seminole Rd ,Atlantic Beach, FL 32233
Ph (1-'104) 247-5826 Fax (904) 247-5845
fOB ADIDUSS: ?j�1 J2- m r PERMIT#
PROJECT VALUE $— 4039 ARI# 710 11.06REQUIRED
Air Handling Equipment Only -Aiar Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit Seer Rating Heat: Unit Quantity BTU's Per Unit gREQUIRE,D
Duct Systems: Total CFM �-
REPLACEMENT AIR CONDITIONING & HEATING �STENT INSTALLATION
Air Conditioning: Unit Quantity 1 Tons Per Unit I �—I-
Heat: Unit Quantity J BTU's Per Unit 10009> Seer Ratizlg
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION Re wires 3 sets of plans)
Fire Sprinkler System. Quantity (Requires 3 sets of plans)
Fixe Standpipe Quantity ( q p )
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity - (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
4 Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solas Collection Systems
Tanks (gallons) .-
Wells
OTHER:
Permit becomes void if work does not commence within a six montli period or work is suspended or abandoned for six months, t hereby certify that 1 have read
,is Application and icnow the same to he true and correct. All provisions or laws and ordinances governing this work will be complied with whether specified or
ot. The permit docs not give authority to violate the provisions of Any other state or local law regulation construction or the performance of construction.
Phone Number �57 -4097-
--
Property Owners Name �L1r�--:_..C1.1�-�� _ - .-�
Mechanical Company nnloyAlJ i-_��' A>! Office Phone 2 t a,�Fax 1
20�-
Co. Address: '6i �� S City �,t�x � State YJ—,Zip .3
License Holder(Print): t jl0�'�'� .D/dN�'' State Certification/Registration
,Notarized Signature of License Holder1 . rJij
1
2r�?P%y�� RICHARDTOMPKIN; Before nye this l.� day o'f rt t 20__x?
Commission#FF 040399
. t expires duly 28,2017 Signature of Notary Public
l9oM+fl thhi Troy F�In lnwnnon 11g4.9R�70fD
- wrightsoft- (Project Summary Date: ars$wa
,Entire House By: Brandon Zaharie
Donovan Heat& Air
315 6th Avo south,Jack9onvllle 9ench,FL 32250 Phony 241-3705 EMAW brandanadonovanac.com
Project • r •
For: Kaeuper
317 Seminole Rd,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 68 OF Inside db 75 OF
Design TD 29 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14414 Btuh Structure 14371 Btuh
Ducts 3195 Btuh Ducts 4674 Btuh
Central vent (13 cfm) 409 Btuh Central vent (13 cfm) 282 Stuh
Humidification 0 Btuh Blower 0 Btuh
piping 0 Btuh
Equipment load 18019 Stuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19327 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1921 Btuh
Ducts 1006 Stuh
Heating Cooling Central vent (13 cfm) 465 Btuh
Area (ft2 1218 1218 Equipment latent load 3392 Btuh
Volume(fts) 10962 10962
Air changes/hour 0.56 0.23 Equipment total load 22718 Btuh
Equiv.AVF (cfm) 102 42 Req. total capacity at 0.70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade Trade
Model NXH530 Cond NXH530
A R I ref no. 7031106 Coil FXMX30
ARI ref no. 7031106
Efficiency8.5 HSPF Efficiency 15.2 EER
Heating iput Sensible cooling 20906 Btuh
Heating output 29717 Stuh @ 47°F Latent cooling 8960 Btuh
Temperature rise 34 OF Total cooling 29866 Btuh
Actual air flow 801 cfm Actual air flow 801 cfm
Air flow factor 0.045 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H2O Lid sensssuble heat ratio 0$5 in H2O
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
A:. -+- vwritght:%%,c !- Rfght-SUKCA Universal 7,1.01 RSU05996 2014-Apr-25 10:58:59
C:tusema SaloslDoouments\Wrlghtsoft HVAC12.5 TON Caic=MJ8 odentstlon-N page 1