591 Sherry Dr HVAC 2014 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000721 Date 5/07/14 Property Address . . . . . . 591 SHERRY DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CRIMAN, CARL MICHAEL DONOVAN HEATING & AIR 591 SHERRY DRIVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/03/14 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 1013 ADDRESS: '591 Sy)e.Y�2� �� PERMIT# PROJECT VALUE $ 1953 rb ARI# 586360 REQUIRED Air Handling Equipment Only YAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity ( Tons Per Unit P5.5 Heat: Unit Quantity---T— BTU's Per Unit On' Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction./o Property Owners Name ►I�I L CY+r-,"C4y^ Phone Number a1/1 -7019 Mechanical Company 'JONOVp►� iAEx" 'd All/ Office Phone V13-71f Fax dV 3-7y5-" City Co. Address: �J15AVE 5Cit State f—) Zip32ZEip License Holder (Print): Vvdlam State Certification/Registration# CA C4 39 -1 Notarized Signature of License Holder Before me this day of �+ 20 NS CommissionH #FF 0140399 *` Expires July 29,20V Signature of Notary Public ' R♦:' �� Bw4W TWu Twy Fein Inwnnw 800466`701Y Project Summa Job: +i+ wrightsoft 1 Date: 5/1/2014 Entire House By: Brendon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email: brandon@donovanac.com Project • • For: Criman 591 Sherry DR,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21477 Btuh Structure 17679 Btuh Ducts 7576 Btuh Ducts 15456 Btuh Central vent (57 cfm) 1804 Btuh Central vent (57 cfm) 1244 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30857 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 34379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2029 Btuh Ducts 2778 Btuh Heating Cooling Central vent (57 cfm) 2047 Btuh Area (ft' 2336 2336 Equipment latent load 6854 Btuh Volume �ft-) 21024 21024 Air Changes/hour 0.38 0.16 Equipment total load 41233 Btuh Equiv. AVF (cfm) 132 56 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make American Standard Make American Standard Trade Trade Model 4A6H5049 Cond 4A6H5049 ARI ref no. 5863601 Coil GAM5BOC48 ARI ref no. 5863601 Efficiency 8.5 HSPF Efficiency 15.5 SEER Heating input Sensible cooling 32292 Btuh Heating output 45903 Btuh @ 47°F Latent cooling 13840 Btuh Temperature rise 27 °F Total cooling 46132 Btuh Actual air flow 1538 cfm Actual air flow 1538 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +I+ wrightsoTt Right-Suite®Universal 7.1.01 RSU05996 2014-May-01 13:24 58 Page 1 AC-N C:\Users\Sales\Documents\Wrightsoft HVAC\4 TON.rup Calc=MJ8 Orientation=N