Loading...
555 Aquatic 2014 HVAC i CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD !) :5 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �'OR Application Number . . . . . 14-00000747 Date 5/12/14 Property Address . . . . . 555 AQUATIC DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- IBARRECHE, GERARD DONOVAN HEATING & AIR 555 AQUATIC DRIVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/08/14 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECH./f'LAICAL PERMIT APPLICATION C 1,TV OF ATLANTIC BEACH 800 `."�.-minole Rd Atlantic Beach, FL 32233 Pl 1,904) 247-5826 Fax (904) 247-5845 los ADDRESS: 5S5 AL U A n c- )), k>az Mrr# PROJECT VALUE S X500 60 AN# 3M 342 REQUIRED Air Handling Equipment Only XAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING &- HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDI J1ONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity f Tons Per Unit Pea : Unit Quantity �� BTU's Per Unit Z40(JD Seer Rating 14 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (.Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity _. (Requires 3 sets of plans) Commercial Hoods Quantity _ (Requires 3 sets of plans) Fire Suppression Systems Quantity — (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/1lscra,l ators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters _ Solar Collection. Systems Tanks (gallons) Wells OTHER: Pcrmit becomes void if work docs not commence within a six month period or work is suspended or abandoned for six months.T hereby certify t A I 11aVC read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will tic complied with whether specified or ot, The pormit does not give authority to violate the provisions of Any otiicr state or local law regulation construction or the performnnee of construction, Property Owners Name reU ¢ Phone Number Mechanical Company v �ea}" i Offiice Phone 2.41 nr( Fax _y� ! 37t/S' Co. Address: _ '))I � A>re City �, bx rl State zip 322,54 License Holder (Print): JL"' I jn.,.. State Certification/Registration #—L40j Notarized Signature of License Il'older I RICHARD TOMP 1 Before w this __ day f 20 _ .i % Commission#FF 040389 ' Expires duly 29,2017 �/� -Rt RA010dThniTmy;ah tmwao000306.1010 Signatl :Ca. o:CNotary Public ✓t + 9 Project Summa Job: wri htsoft � � Date: May 6,2014 ' Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax:904241-3745 Email:aaron@donovanac.com Web:wrow.DonovanAC.com Project • • For: Gerard Ibarreche 555 Aquatic Dr,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 24 °F Daily range L Relative humidity 50 % Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10754 Btuh Structure 9911 Btuh Ducts 1856 Btuh Ducts 3243 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12610 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13680 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2241 Btuh Ducts 917 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1140 1140 Equipment latent load 3158 Btuh Volume (ft') 9120 9120 Air changes/hour 0.45 0.23 Equipment total load 16838 Btuh Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R41 OA HP Trade 13 SEER N SERIES R41 OA HP Model N4H324A(G)KA* Cond N4H324A(G)KA* AHRI ref no3464342 Coil FEA4X24**A* AHRI ref no3464342 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 15820 Btuh Heating output 23600 Btuh @ 47°F Latent cooling 6780 Btuh Temperature rise 28 °F Total cooling 22600 Btuh Actual air flow 753 cfm Actual air flow 753 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ + wrightsoft 2014-May-06 14 33:38 Right-Suite®Universal 8.0.24 RSU05995 Page 1 ACh`' C\Users\Owner\Documents\Wrightsoft MVAC\Bogus 2 ton.rup Calc=MJ8 Front Door faces W