Loading...
355 Plaza 2014 HVAC .� ► -1 y !1v� CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD J =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 J ILI S) Application Number . . . . . 14-00000709 Date 5/06/14 Property Address . . . . . . 355 PLAZA Tenant nbr, name . . . . . . FRONT UNIT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BLEDSOE JR, JAMES A DONOVAN HEATING & AIR 4653 EMPIRE AVE 315 SIXTH AVENUE SOUTH JACKSONVILLE FL 32207 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/02/14 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: X65 PIg2A S Front „r,l PERMIT# PROJECT VALUE $ 9 M 3 7 ARI# X 70 3 D REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity i Tons Per Unit 2- Heat: Heat: Unit Quantity ! BTU's Per UnitZis� Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 1) 0-49-1 R 6k P-(As-Be- Phone Number 39$"/a/ Mechanical Company 1' )0n oy oy" He o i �' Air Office Phone 9P 3-795 Fax 2#1 3-7V Co. Address: �J fiS Aw— S City �—Ax '9 ci, State Zip 3zzr0 License Holder(Print): , 1io l A State Certification/Registration# Notarized Signature of License Holder Fa-tw RICHARD TOMPKINSBefore me this daCommission#FF 040399 Expires July 29,2017 Signature of Notary PublicBaled Thu Troy Fan h..8003857019 Job: +{+ wrightsoft Project Summary Date: 511/14 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email: brandon@donovanac.com Proiect Information For: Bledeoe 335 Plaza st,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 'F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13919 Btuh Structure 11729 Btuh Ducts 2799 Btuh Ducts 5690 Btuh Central vent (12 cfm) 370 Btuh Central vent (12 cfm) 255 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17088 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1638 Btuh Fireplaces 1 (Average) Structure Ducts 973 Btuh Heating Cooling Central vent (12 cfm) 420 Btuh Area (ft' 1152 1152 Equipment latent load 3031 Btuh Volume �ft3) 10368 10368 Air changes/hour 0.57 0.23 Equipment total load 20706 Btuh Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HCB524 Cond 25HCB524 ARI ref no. 3670830 Coil FV4CNF002 ARI ref no. 3670830 15.5 SEER Efficiency 9 HSPF Efficiency Heating input Sensible cooling 15747 Btuh Heating output 22384 Btuh @ 47'F Latent cooling 6749 Btuh Temperature rise 27 °F Total cooling 22496 Btuh Actual air flow 750 cfm Actual air flow 750 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +++ wrightsoft Right-Suite®Universal 7-1.01 RSUD5996 2014-May-01 15:31 10 ACGl" C:\Users\Sales\Documents\Wrightsoft HVAC\2Ton.rup Calc=MJ8 Orientation=N Page 1