Loading...
1232 Main St 2014 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000921 Date 6/10/14 Property Address . . . . . . 1232 MAIN ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SMITH, KEVIN P DONOVAN HEATING & AIR 1232 MAIN ST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Plan Check Fee . 00 Permit Fee . . . . 91 . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/07/14 --------------------------------------------------------------------- ------ Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 1013 ADDRESS: PERMIT# PROJECTVALUE $ 3300'C.) ARI# �3&5300 _REQUIRED Air Handling Equipment Only _XAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 1z Heat: Unit Quantity I BTU's Per Unit !q DVO Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority 0 violate theSrovisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 12V)Y- M Phone Number 6 SS 76 '.5 9 — Office PhonedkVtf Fax c9YI 3-70 Mechanical Company �boklvbjj Haa Co. Address: /�Is �4� '1� City ,,'-FgX &4, State f I Zip'3220 A-Ir- > License Holder(Print):- �Alj// State Certification/Registration# A no3 9 7-� Notarized:20ature of License Holder "�Di rL—,42�� av of 20 RICHARD TOMPKINS Before me this d JV "-`A**�.- Commission#FF 040399 Expires July 29,2017 r,A oy-` Boded Thm Vey Fam Ineumtee BOG-W7019 Signature of Notary Public Job: + wrightsoft Project Summary Date: June 6,2014 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S, Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAG.com Project Information For'. Kevin Smith 1232 Main St,Atlantic Beach, FIL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 99 'F Inside db 70 'F Inside db 75 'F Design TD 31 'F Design TD 24 oF Daily range L Relative humidity 50 % Moisture difference 69 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10754 Btuh Structure 9911 Btuh Ducts 1856 Btuh Ducts 3243 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh p1pigg 0 Btuh er's data n Equipment load 12610 Btuh Use manufactur Rate/swin multiplier 1.04 Infiltration Equipmen?sensible load 13680 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2241 Btuh Ducts 917 Btuh Heati n Coolin Central vent (0 cfm) 0 Btuh Area (ft2) 1149 1149 Equipment latent load 3158 Btuh Volume (ft') 9120 9120 16838 Btuh Air changesi 0.45 0.23 Equipment total load Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R41 OA H P Model N4H324A(G)KA- Cond N4H324A(G)KA- AHRI ref no3853298 Coil FEM4P24**A* AHRI ref no3853298 11.0 EER, 13 SEER Efficiency 8 HSPF Efficiency Heating input Sensible cooling 15820 Btuh Heating output 23000 Btuh @ 47'F Latent cooling 6780 Btuh Temperature rise 28 'F Total cooling 22600 Btuh Actual air flow 753 cfm Actual air flow 753 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.057 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jun-09 W55 44 wrightsoft Right-Suite@ Universal 8.0.24 RSU05995 Page 1 c\users\Ovner\Documents\Wrightsoft WAC\Bogus 2 ton.rup Calc=MJ8 Front Door faces W